Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temporal learning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Medium-Range River Flood Forecasts Using a Long Short-Term Memory Network

River flooding and the impacts are a concern for decision makers throughout the United States. Accurate medium-range forecasts (~3-7 days) are critical for providing advanced outlooks to emergency management officials. Unfortunately, accurately forecasting rainfall-runoff and the subsequent rise and fall within rivers remain a challenge in hydrological modeling. While complex physical modeling systems are the standard for representing the hydrological processes, they are computationally demanding and can require extensive calibration. Further, uncertainties remain in the model parameters and input data. The use of machine learning can reduce some of the computational demand while maintaining high accuracy. Therefore, this project makes use of a Long Short-Term Memory (LSTM) network which explicitly accounts for the time-dependent nature of rainfall-runoff modeling. The developed LSTM was trained to predict river gauge height, or stage height, based on time-lagged input features which include: gauge height to initialize the model, the NASA Short-term Prediction Research and Transition Center’s instance of the Land Information System (SPoRT-LIS) relative soil moisture to describe the rainfall infiltration rate, and 6-hr Multi-Radar Multi-Sensor quantitative precipitation estimate (MRMS QPE). The developed LSTM based system is then used to produce 7-day forecasts with a 6-hr temporal resolution using three different quantitative precipitation forecasts (QPF) from the NWS’s Weather Prediction Center (WPC), the NCEP Global Forecast System (GFS) model and the National Blend of Models (NBM). This trained modeling system has been implemented as an experimental product at over 100 different rivers in collaboration with at multiple National Weather Service (NWS) Forecast Offices and River Forecast Centers (RFC) across the eastern half of the United States. The developed LSTM model achieved average Nash-Sutcliffe efficiency (NSE) 0.89 higher than the equivalent medium-range National Water Model ensemble member forecast over a 7-day forecast. In addition to the initial development and evaluation, this project has continued to expand. While the initial model was developed for precipitation dominated basins, expansion of the project has taken it to basins effected by snow melt. This presentation will provide an overview of the project with focus on recent developments on incorporating snow melt processes into the model.

Andrew T. White↗

Atmospheric Structure Prediction for Infrasound Propagation Modeling Using Deep Learning

Abstract Infrasound is generated by a variety of natural and anthropogenic sources. Infrasonic waves travel through the dynamic atmosphere, which can change on the order of minutes to hours. Infrasound propagation largely depends on the wind and temperature structure of the atmosphere. Numerical weather prediction models are available to provide atmospheric specifications, but uncertainties in these models exist and they are computationally expensive to run. Machine learning has proven useful in predicting tropospheric weather using Long Short‐Term Memory (LSTM) networks. An LSTM network is utilized to make atmospheric specification predictions up to ∼30 km for three different training and testing scenarios: (a) the model is trained and tested using only radiosonde data from the Albuquerque, NM, USA station, (b) the model is trained on radiosonde stations across the contiguous US, excluding the Albuquerque, NM, USA station, which was reserved for testing, and (c) the model is trained and tested on radiosonde stations across the contiguous US. Long Short‐Term Memory predictions are compared to a state‐of‐the‐art reanalysis model and show cases where the LSTM outperforms, performs equally as well, or underperforms in comparison to the state‐of‐the‐art. Regional and temporal trends in model performance across the US are also discussed. Results suggest that the LSTM model is a viable tool for predicting atmospheric specifications for infrasound propagation modeling.

54 ENVIRONMENTAL SCIENCES↗

Retrospective Search for Strongly Lensed Supernovae in the DESI Legacy Imaging Surveys

The introduction of deep wide-field surveys in recent years and the adoption of machine-learning techniques have led to the discoveries of $\mathcal{O}$(10 4 ) strong gravitational lensing systems and candidates. However, the discovery of multiply-lensed transients remains a rarity. Lensed transients and especially lensed supernovae are invaluable tools to cosmology because they allow us to constrain cosmological parameters via lens modeling and the measurements of their time delays. In this paper, we develop a pipeline to perform a targeted lensed transient search. We apply this pipeline to 5807 strong lenses and candidates, which were identified in the literature, in the DESI Legacy Imaging Surveys Data Release 9 (DR9) footprint. For each system, we analyze every exposure in all of the observed bands (DECam g, r, and z). Our pipeline finds, groups, and ranks detections that are in sufficient proximity temporally and spatially. After the first round of inspection, for promising candidate systems, we further examine the newly available DR10 data (with additional i and Y bands). Here we present our targeted lensed supernova search pipeline and seven new lensed supernova candidates, including a very likely lensed supernova—probably a Type Ia—in a system with an Einstein radius of ~1$^{"}_{.}$5.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast and accurate learned multiresolution dynamical downscaling for precipitation

Abstract. This study develops a neural-network-based approach for emulating high-resolution modeled precipitation data with comparable statistical properties but at greatly reduced computational cost. The key idea is to use combination of low- and high-resolution simulations (that differ not only in spatial resolution but also in geospatial patterns) to train a neural network to map from the former to the latter. Specifically, we define two types of CNNs, one that stacks variables directly and one that encodes each variable before stacking, and we train each CNN type both with a conventional loss function, such as mean square error (MSE), and with a conditional generative adversarial network (CGAN), for a total of four CNN variants. We compare the four new CNN-derived high-resolution precipitation results with precipitation generated from original high-resolution simulations, a bilinear interpolater and the state-of-the-art CNN-based super-resolution (SR) technique. Results show that the SR technique produces results similar to those of the bilinear interpolator with smoother spatial and temporal distributions and smaller data variabilities and extremes than the original high-resolution simulations. While the new CNNs trained by MSE generate better results over some regions than the interpolator and SR technique do, their predictions are still biased from the original high-resolution simulations. The CNNs trained by CGAN generate more realistic and physically reasonable results, better capturing not only data variability in time and space but also extremes such as intense and long-lasting storms. The new proposed CNN-based downscaling approach can downscale precipitation from 50 to 12 km in 14 min for 30 years once the network is trained (training takes 4 h using 1 GPU), while the conventional dynamical downscaling would take 1 month using 600 CPU cores to generate simulations at the resolution of 12 km over the contiguous United States.

54 ENVIRONMENTAL SCIENCES↗

Monitor and Evaluate the Genetic Characteristics of Supplemented Salmon and Steelhead, 2006-2007 Progress Report.

This progress report offers a summary of genetic monitoring and evaluation research related to artificial propagation of Chinook salmon and steelhead in the Snake River basin. Our principal goal has been to characterize the relative (and net) reproductive success of hatchery fish spawning in the wild in multiple sub-basins. We address a critical uncertainty identified in essentially all tribal, state, and federal recovery planning efforts. Beyond simple description of those patterns of differential reproductive success, we seek to understand the biotic and abiotic factors that contribute to our observations, including genetic and environmental elements, and the real time effects of hatchery reform. We adopt two fundamentally different approaches that capture processes operating at different geographic scales. Our tier 2 design monitors changes in gene frequency through time in hatchery and wild populations. These studies monitor spatial and temporal genetic change over broad river basins and sub-basins. Tier 3 studies, by contrast, are able to construct pedigrees in naturally spawning populations that include hatchery and wild fish. We can then use actual matings to infer the fitness of hatchery versus wild individuals, based on the numbers of offspring we observe in our progeny samples. We get extraordinary detail from the tier 3 studies but only for a single river system. Thus, tier 2 studies provide breadth of information, whereas tier 3 studies offer unparalleled depth of insight for single discrete systems. We exceeded our goals in almost all areas for both tier 2 and tier 3 studies, and, where we did not, we offer an explanation of why, and what future action will be taken (Lessons Learned). All subcontracts were let as expected, providing smolt trapping, tissue sampling, genotyping, and analysis. Our inter-laboratory standardization efforts with tribal, state, and federal agencies were highly successful in this period. These standardization activities have been an on-going element of this study, beginning with WDFW's forays into DNA markers in the late 1990s and continuing and becoming more formalized with the initiation of the newer genetics laboratories (CRITFC, USFWS, and IDFG). This report is intended to document success in achieving collection and genotyping goals. Data analyses, presentation, and publication are keeping pace with data collection; however, detailed results are not presented at this time. A complete and comprehensive analysis and description of results will be provided in published manuscripts and in the 2009 annual report (the culmination of the current 3-year rolling review cycle). In the first section of this report, we present accomplishments related to individual projects within this genetic monitoring program. Subsequent to the standard reporting categories, we provide a Specific Obligations section that lists accomplishments exactly as the deliverables are presented in the Pisces Statement of Work. This approach results in a small amount of redundancy, but we try to minimize obvious cases. The goal is to provide our accomplishments in a format that is easily compared to the Work-Element-driven format of Pisces, yet also provide a narrative that shows continuity with the individual studies that make up this research program.

13 HYDRO ENERGY↗

The ecosystem approach in ecological impact assessment: Lessons learned from windfarm developments on peatlands in Scotland

Highlights: • Recent wind energy projects in Scotland mostly fail to consider ecosystem-level impacts on peatland. • Projects on peatland illustrate the usefulness of an ecosystem approach to Environmental Impact Assessment. • Defining more meaningful functional management units can improve Environmental Impact Assessment outcomes. • VAn ecosystem approach could also improve ecosystem services assessments. - Abstract: The Ecosystem Approach introduced in 1994 through the Convention on Biological Diversity, together with related Ecosystem-based Management and Landscape Approaches, are frequently called upon to improve ecological impact assessment. Current practice typically does not have such a systems focus and we explore the potential for explicitly adopting an Ecosystem Approach in the Environmental Impact Assessment process using wind energy development on peatland, in Scotland, as a case study. Based on a review of 21 windfarm projects (>50 MW) approved by the Scottish Government we provide an overview of current practice and identify and discuss how the 12 principles of the Ecosystem Approach can help identify options for more appropriate impact assessment. These include defining functional units of analysis that reflect the spatial and temporal linkages of peatland elements through hydrological connections, rather than a focus on individual vegetation types and simple distance buffers. Our conclusions are not limited to peatland and are relevant wherever meaningful functional management units can be defined, including in marine environments. Our results also show that environmental statements for wind energy development in Scotland largely ignore ecosystem services and the people that benefit from them. As for threatened species and other biodiversity features, an Ecosystem Approach is a prerequisite to the meaningful inclusion of ecosystem services in impact assessment.

54 ENVIRONMENTAL SCIENCES↗

From disorganized data to emergent dynamic models: Questionnaires to partial differential equations

Starting with sets of disorganized observations of spatially varying and temporally evolving systems, obtained at different (also disorganized) sets of parameters, we demonstrate the data-driven derivation of parameter dependent, evolutionary partial differential equation (PDE) models capable of generating the data. This tensor type of data is reminiscent of shuffled (multidimensional) puzzle tiles. The independent variables for the evolution equations (their “space” and “time”) as well as their effective parameters are all emergent , i.e. determined in a data-driven way from our disorganized observations of behavior in them. We use a diffusion map based questionnaire approach to build a smooth parametrization of our emergent space/time/parameter space for the data. This approach iteratively processes the data by successively observing them on the “space,” the “time” and the “parameter” axes of a tensor. Once the data become organized, we use machine learning (here, neural networks) to approximate the operators governing the evolution equations in this emergent space. Our illustrative examples are based (i) on a simple advection–diffusion model; (ii) on a previously developed vertex-plus-signaling model of Drosophila embryonic development; and (iii) on two complex dynamic network models (one neuronal and one coupled oscillator model) for which no obvious smooth embedding geometry is known a priori. This allows us to discuss features of the process like symmetry breaking, translational invariance, and autonomousness of the emergent PDE model, as well as its interpretability.

generative models↗

Development and validation of a supervised machine learning radar Doppler spectra peak-finding algorithm

In many types of clouds, multiple hydrometeor populations can be present at the same time and height. Studying the evolution of these different hydrometeors in a time–height perspective can give valuable information on cloud particle composition and microphysical growth processes. However, as a prerequisite, the number of different hydrometeor types in a certain cloud volume needs to be quantified. This can be accomplished using cloud radar Doppler velocity spectra from profiling cloud radars if the different hydrometeor types have sufficiently different terminal fall velocities to produce individual Doppler spectrum peaks. Here we present a newly developed supervised machine learning radar Doppler spectra peak-finding algorithm (named PEAKO). In this approach, three adjustable parameters (spectrum smoothing span, prominence threshold, and minimum peak width at half-height) are varied to obtain the set of parameters which yields the best agreement of user-classified and machine-marked peaks. The algorithm was developed for Ka-band ARM zenith-pointing radar (KAZR) observations obtained in thick snowfall systems during the Atmospheric Radiation Measurement Program (ARM) mobile facility AMF2 deployment at Hyytiälä, Finland, during the Biogenic Aerosols – Effects on Clouds and Climate (BAECC) field campaign. The performance of PEAKO is evaluated by comparing its results to existing Doppler peak-finding algorithms. The new algorithm consistently identifies Doppler spectra peaks and outperforms other algorithms by reducing noise and increasing temporal and height consistency in detected features. In the future, the PEAKO algorithm will be adapted to other cloud radars and other types of clouds consisting of multiple hydrometeors in the same cloud volume.

54 ENVIRONMENTAL SCIENCES↗

Adaptive control with an expert system based supervisory level

Adaptive control is presently one of the methods available which may be used to control plants with poorly modelled dynamics or time varying dynamics. Although many variations of adaptive controllers exist, a common characteristic of all adaptive control schemes, is that input/output measurements from the plant are used to adjust a control law in an on-line fashion. Ideally the adjustment mechanism of the adaptive controller is able to learn enough about the dynamics of the plant from input/output measurements to effectively control the plant. In practice, problems such as measurement noise, controller saturation, and incorrect model order, to name a few, may prevent proper adjustment of the controller and poor performance or instability result. In this work we set out to avoid the inadequacies of procedurally implemented safety nets, by introducing a two level control scheme in which an expert system based 'supervisor' at the upper level provides all the safety net functions for an adaptive controller at the lower level. The expert system is based on a shell called IPEX, (Interactive Process EXpert), that we developed specifically for the diagnosis and treatment of dynamic systems. Some of the more important functions that the IPEX system provides are: (1) temporal reasoning; (2) planning of diagnostic activities; and (3) interactive diagnosis. Also, because knowledge and control logic are separate, the incorporation of new diagnostic and treatment knowledge is relatively simple. We note that the flexibility available in the system to express diagnostic and treatment knowledge, allows much greater functionality than could ever be reasonably expected from procedural implementations of safety nets. The remainder of this chapter is divided into three sections. In section 1.1 we give a detailed review of the literature in the area of supervisory systems for adaptive controllers. In particular, we describe the evolution of safety nets from simple ad hoc techniques, up to the use of expert systems for more advanced supervision capabilities.

Sullivan, Gerald A.↗

Smart sensors using artificial intelligence for on-detector electronics and ASICs

Cutting edge detectors push sensing technology by further improving spatial and temporal resolution, increasing detector area and volume, and generally reducing backgrounds and noise. This has led to a explosion of more and more data being generated in next-generation experiments. Therefore, the need for near-sensor, at the data source, processing with more powerful algorithms is becoming increasingly important to more efficiently capture the right experimental data, reduce downstream system complexity, and enable faster and lower-power feedback loops. In this paper, we discuss the motivations and potential applications for on-detector AI. Furthermore, the unique requirements of particle physics can uniquely drive the development of novel AI hardware and design tools. We describe existing modern work for particle physics in this area. Finally, we outline a number of areas of opportunity where we can advance machine learning techniques, codesign workflows, and future microelectronics technologies which will accelerate design, performance, and implementations for next generation experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-BRB-03: Clinical Implementation of MR-Based Motion Management

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-1: Tools for Collecting and Analyzing Patient Dose Index Information from Imaging Equipment

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-2: How to Move Beyond Dose Monitoring to Imaging Performance Utilization

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-3: Simultaneous tracking of patient and real time staff dose to optimize interventional workflow

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-4: How to implement a dose monitoring solution in the real world: a technical perspective

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-5: Use of the Enterprise-wide Dose Tracking Software Radimetrics In an Academic Medical System

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-F-BRB-00: MRI-Based Motion Management for RT

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

TU-F-BRB-01: Resolving and Characterizing Breathing Motion for Radiotherapy with MRI

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗