Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Active Optical Sounding of Ozone and Minor Constituents in the Middle Atmosphere: a Review of Ground-based Lidar Measurements

Due to the rapid development of powerful laser sources in the UV wavelength range which includes nd:yag pumped dye lasers and excimer lasers, ground-based lidar systems are now operational for ozone monitoring in the troposphere and the stratosphere. Such systems will play an important role in the determination of long term ozone trends in the photochemical region. The capacities of active lidar systems in terms of high temporal and spatial resolution and measurements continuity, allow the observation of the ozone variations at various time and space scales which are important in present day areas of interest. The already operational character of the lidar systems will constitute the basis for development of a ground-base network for middle atmospheric observations of ozone and other race gases.

Megie, G.↗

Capacity-cycle life behavior in secondary lithium cells

The practical utilization of high energy density rechargeable lithium cells is dependent upon maintaining high capacity for the duration of the required cycle life. However, a critical, yet generic problem with room temperature lithium systems is that the capacity often declines considerably during the early stages of cycling. The results of our studies are reported on electrolyte degradation which is observed after cells have undergone 300 and 700 deep cycles with 3-methylsulfolane- and 2-methyltetrahydrofuran-LiAsF6 electrolytes, respectively.

Somoano, R. B.↗

Building and managing high performance, scalable, commodity mass storage systems

The NAS Systems Division has recently embarked on a significant new way of handling the mass storage problem. One of the basic goals of this new development are to build systems at very large capacity and high performance, yet have the advantages of commodity products. The central design philosophy is to build storage systems the way the Internet was built. Competitive, survivable, expandable, and wide open. The thrust of this paper is to describe the motivation for this effort, what we mean by commodity mass storage, what the implications are for a facility that performs such an action, and where we think it will lead.

Lekashman, John↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (MEME-CCS)

This effort employs and adapts an existing, rigorous multiscale electricity modeling platform at the National Renewable Energy Laboratory (NREL) to evaluate carbon capture and sequestration (CCS) and negative emissions technologies (NET) from the ARPA-E FLECCS program. NREL's modeling platform includes the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model, which projects future electricity generation mixes at sub-state-level resolution that are downscaled to the unit-level to enable hourly, zonal or nodal electricity production cost modeling in the PLEXOS model. The resulting hourly price data from PLEXOS is provided to technology developers under the ARPA-E FLECCS program to enable technology-specific economic analysis. The ReEDS-PLEXOS modeling suite is well-established for examining electric sector futures with high renewable energy penetrations, energy storage, electrification, and distributed generation. The key advancement proposed herein utilizes collaboration with CCS experts at the University of Wyoming and the FLECCS teams to create innovative methods for representing CCS and NET in the ReEDS and PLEXOS models. Expanded technology options, new operational parameterizations, and detailed data defining CO2 capture, transportation, and storage systems are being integrated into these models to allow an unprecedented combination of scope and resolution for exploring the future of CCS and NET. The resulting capabilities will take advantage of high-performance computing resources to permit wide-ranging scenario analysis to assess CCS and NET deployment under alternative CO2 prices, fossil fuel prices, electricity demand growth, and other electric sector characteristics. Final outcomes will include publicly available hourly grid operation and price data for any U.S. region of interest along with open-access capacity expansion tools for evaluating CCS/NET systems. These products will help an emerging CCS/NET industry in the United States by providing economics-driven guidance to technology developers while informing policy and investment decisions in the public and private sectors.

air capture↗

Commissioning and operational results of helium refrigeration system at JLab for the 12GeV upgrade

The new 4.5 K refrigerator system at the Jefferson Lab (JLab) Central Helium Liquefier (CHL-2) for the 12 GeV upgrade was commissioned in late spring of 2013, following the commissioning of the new compressor system, and has been supporting 12 GeV LINAC commissioning since that time. Six design modes were tested during commissioning, consisting of a maximum capacity, nominal capacity, maximum liquefaction, maximum refrigeration, maximum fill and a stand-by/reduced load condition. The maximum capacity was designed to support a 238 g/s, 30 K and 1.16 bar cold compressor return flow, a 15 g/s, 4.5 K liquefaction load and a 12.6 kW, 35-55 K shield load. The other modes were selected to ensure proper component sizing and selection to allow the cold box to operate over a wide range of conditions and capacities. The cold box system is comprised of two physically independent cold boxes with interconnecting transfer-lines. The outside (upper) 300-60 K vertical cold box has no turbines and incorporates a liquid nitrogen pre-cooler and 80-K beds. The inside (lower) 60-4.5 K horizontal cold box houses seven turbines that are configured in four expansion stages including one Joule-Thompson expander and a 20-K bed. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will summarize the analysis of the test data obtained over the wide range of operating conditions and capacities which were tested.

Knudsen, Peter N.↗

Building waste management core indicators through Spatial Material Flow Analysis: Net recovery and transport intensity indexes

Highlights: Black-Right-Pointing-Pointer Sustainability and proximity principles have a key role in waste management. Black-Right-Pointing-Pointer Core indicators are needed in order to quantify and evaluate them. Black-Right-Pointing-Pointer A systematic, step-by-step approach is developed in this study for their development. Black-Right-Pointing-Pointer Transport may play a significant role in terms of environmental and economic costs. Black-Right-Pointing-Pointer Policy action is required in order to advance in the consecution of these principles. - Abstract: In this paper, the material and spatial characterization of the flows within a municipal solid waste (MSW) management system are combined through a Network-Based Spatial Material Flow Analysis. Using this information, two core indicators are developed for the bio-waste fraction, the Net Recovery Index (NRI) and the Transport Intensity Index (TII), which are aimed at assessing progress towards policy-related sustainable MSW management strategies and objectives. The NRI approaches the capacity of a MSW management system for converting waste into resources through a systematic metabolic approach, whereas the TII addresses efficiency in terms of the transport requirements to manage a specific waste flow throughout the entire MSW management life cycle. Therefore, both indicators could be useful in assessing key MSW management policy strategies, such as the consecution of higher recycling levels (sustainability principle) or the minimization of transport by locating treatment facilities closer to generation sources (proximity principle). To apply this methodological approach, the bio-waste management system of the region of Catalonia (Spain) has been chosen as a case study. Results show the adequacy of both indicators for identifying those points within the system with higher capacity to compromise its environmental, economic and social performance and therefore establishing clear targets for policy prioritization. Moreover, this methodological approach permits scenario building, which could be useful in assessing the outcomes of hypothetical scenarios, thus proving its adequacy for strategic planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation↗

Commissioning of helium refrigeration system at JLab for 12 GeV upgrade

The new 4.5 K refrigerator system added to the Jefferson Lab (JLab) Central Helium Liquefier (CHL) for the 12 GeV upgrade will double its previous capacity. It includes a 4.5 K cold box system and compressor system with associated oil removal and gas management systems. At its maximum capacity condition, this new system supports an additional 238 g/s 30 K 1.16 bar cold compressor return flow, a 15 g/s 4.5 K liquefaction load and a 12.6 kW 35–55 K shield load. Five more design conditions, ranging from liquefaction to refrigeration and a stand-by/reduced load state, were specified for the sizing and selection of its components. The cold box system is comprised of a 300–60 K vertical cold box that incorporates a liquid nitrogen pre-cooler and a 60–4.5 K horizontal cold box housing seven turbines that are configured in four expansion stages including one Joule-Thompson expander. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will briefly review the salient 4.5 K system design features and discuss the recent commissioning results.

42 ENGINEERING↗

Providing Global Change Information for Decision-Making: Capturing and Presenting Provenance

Global change information demands access to data sources and well-documented provenance to provide evidence needed to build confidence in scientific conclusions and, in specific applications, to ensure the information's suitability for use in decision-making. A new generation of Web technology, the Semantic Web, provides tools for that purpose. The topic of global change covers changes in the global environment (including alterations in climate, land productivity, oceans or other water resources, atmospheric composition and or chemistry, and ecological systems) that may alter the capacity of the Earth to sustain life and support human systems. Data and findings associated with global change research are of great public, government, and academic concern and are used in policy and decision-making, which makes the provenance of global change information especially important. In addition, since different types of decisions benefit from different types of information, understanding how to capture and present the provenance of global change information is becoming more of an imperative in adaptive planning.

provenance tracking↗

A Technology Architecture for Accessing the Oceans of Icy Worlds

The icy moon oceans beckon with ingredients that potentially may harbour extant life. Beginning with the Galileo and Cassini missions, measurements have revealed the presence of global oceans under the icy crust of several moons of Jupiter and Saturn. Among those moons, Europa and Enceladus have their ocean in contact with the rocky core, providing an environment similar to the conditions existing on the terrestrial sea-floor where life has developed at hydrothermal vents Accessing these oceans presents considerable difficulty due to a number of issues including the depth and composition of the icy crust, the time needed to travel through the crust, the power needed to propel a probe, communication of scientific and engineering data though the ice and back to Earth, entry and mobility in the ocean and autonomous operations for the life of the mission. A detailed trade space study was conducted to develop a technology architecture defining a system that would access an icy moon’s ocean. To specifically bound the architecture, Jupiter’s moon Europa was chosen as the target body though the work can apply to other bodies. The current understanding of the scientific properties of the ice crust and ocean was used to guide the development. A strawman scientific payload was devised to further develop a baseline set of requirements. Beginning with a launch and trajectory that can bring a system to Europa’s orbit, a complete trade space was developed outlining the engineering systems needed to access the ocean. The architecture was divided into specific phases for i) deorbit, descent and landing, ii) surface operations, iii) ice descent and iv) ocean access. The technical maturity of each of sub-system for the phases was assessed for systems that could be developed to a maturity ready for a preliminary design in less than ten years. Integrated system parameters on power, communication capacity, and mass were developed to further define the overall system. To constrain the design, a total time in the ice, from the ice crust surface to accessing the ocean was limited to three years, and 15Km of ice was baselined with a temperature profile through the ice estimated from the scientific literature.

Sengupta, Anita↗

Favorable Structural–Tectonic Settings and Characteristics of Globally Productive Arcs

There are currently 74 productive geothermal systems associated with volcanic centers (VCs) in arcs globally, including actively producing systems, past producing systems, and systems with successful flow tests. The total installed or tested capacity of these 74 geothermal systems is 7,605 MWe, ranging from 0.7 MWe each at Copahue, Chile and Barkhatnaya Sopka, Kamchatka to 795 MWe, Larderello, Italy, and averaging 90.5 MWe per system. These 74 productive VCs constitute 10% of 732 VCs distributed across more than a dozen major arcs around the world. The intra-arc (within-arc) tectonic setting is highly variable globally, ranging from extension to transtension, transpression, or compression. Furthermore, the shear strain associated with oblique plate convergence can be accommodated by either intra-arc or arc-marginal deformation. The structural-tectonic settings of these 74 productive VCs were characterized to add to a global catalog of parameters to help guide future exploration, development, and regional resource potential.

15 GEOTHERMAL ENERGY↗

Numerical and experimental analysis of a thin liquid film on a rotating disk related to development of a spacecraft absorption cooling system

The numerical and experimental analysis of a thin liquid film on a rotating and a stationary disk related to the development of an absorber unit for a high capacity spacecraft absorption cooling system, is described. The creation of artificial gravity by the use of a centrifugal field was focused upon in this report. Areas covered include: (1) One-dimensional computation of thin liquid film flows; (2) Experimental measurement of film height and visualization of flow; (3) Two-dimensional computation of the free surface flow of a thin liquid film using a pressure optimization method; (4) Computation of heat transfer in two-dimensional thin film flow; (5) Development of a new computational methodology for the free surface flows using a permeable wall; (6) Analysis of fluid flow and heat transfer in a thin film in the presence and absence of gravity; and (7) Comparison of theoretical prediction and experimental data. The basic phenomena related to fluid flow and heat transfer on rotating systems reported here can also be applied to other areas of space systems.

Faghri, Amir↗

Predictions of particle size and lattice diffusion pathway requirements for sodium-ion anodes using eta-Cu6Sn5 thin films as a model system

Geometrically well-defined Cu6Sn5 thin films were used as model systems to estimate the diffusion depth and diffusion pathway requirements of Li and Na ions in alloy anodes. eta-Cu6Sn5 anodes have an initial reversible capacity towards Li of 545 mAh g-1 (Li3.96Sn or 19.8 Li/Cu6Sn5) and a very low initial irreversible capacity of 1.6 Li/Cu6Sn5. In contrast, the reaction with Na is limited with a reversible capacity of 160 mAh g-1 compared to the expected 516 mAh g-1. The potential profile is analogous to that of pure Sn with an average potential of 0.3 V. X-ray diffraction and 119Sn-M ssbauer measurements show that this limited capacity is likely resulting from the limited diffusion of Na into the anode particles not the formation of a low Na-content phase. This is substantiated by the analysis of the structure of eta-Cu6Sn5 which revealed zig-zag and tunnel diffusion pathways with spherical voids with a diameter very close to that of Na+. Moreover, our results also indicate that an alloy of eta-Cu6Sn5 should have optimized particle sizes of about 10 nm in diameter to increase the Na-capacity significantly. An alternative system consisting of a mixture of Cu6Sn5 and Sn of nominal composition Cu6Sn10 has been studied as possible Na-ion anode material possessing higher storage capacity than pure Cu6Sn5. Indeed this mixture of phase delivers a larger initial reversible storage capacity up to 400 mAh g-1. Finally, we have evidenced that the presence of Cu in Cu6Sn5 and in Cu6Sn10 suppresses the anomalous electrolyte decomposition normally measured for pure Sn at 1.2 V during discharge.

119Sn M ssbauer spectroscopy↗

Hosting Capacity Improvement Method Using MV–MV Solid-State-Transformer

As a large number of distributed generations are connected to the distribution system, research on the hosting capacity is actively being conducted. In particular, various methods, such as smart inverter functionality, co-located energy storage systems (ESS), and the use of on-load tap changers (OLTC), have been proposed to improve the hosting capacity. In this paper, a method to improve the hosting capacity by utilizing a solid-state transformer (SST) and its unique control capability is proposed. Lastly, the proposed method is verified in the distribution system of the Republic of Korea using the OpenDSS program.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Inverter Functions and Their Impact on Hosting Capacity

This presentation gives a high-level overview of past and current results related to advanced PV inverter functions, such as volt/var control, and how such functions enable higher PV hosting capacity levels in distribution systems.

advanced inverter functions↗

Hydrogen Adsorbents with High Volumetric Density: New Materials and System Projections

A high-capacity, low-cost method for storing hydrogen remains one of the primary barriers to the widespread commercialization of fuel cell vehicles. Storage via adsorption is a promising approach due to its fast kinetics, reversibility, and high gravimetric densities. An unfortunate characteristic of adsorptive storage is that high gravimetric densities typically come at the expense of volumetric density (total basis). The goal of this project is to demonstrate best-in-class adsorbents based on metal-organic frameworks (MOFs) that achieve high volumetric and gravimetric H 2 densities simultaneously, while maintaining reversibility and fast kinetics. This is accomplished using a combination ion of high-throughput computational screening and experimental synthesis and characterization. The performance of the most promising materials are projected to the system level by parameterizing system models developed by the Hydrogen Storage Engineering Center of Excellence (HSECoE).

08 HYDROGEN↗

Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗