Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “surface breakdown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

F-18 high alpha research vehicle surface pressures - Initial in-flight results and correlation with flow visualization and wind-tunnel data

Flight tests with the NASA F-18 high-alpha research vehicle (HARV) have yielded pressure distributions at angles of attack from 10 to 50 deg, at Mach 0.23 to 0.6, at five fuselage forebody stations and three on the leading-edge extensions (LEXs). Correlations are made between these data and both previously obtained HARV flow visualizations and wind tunnel model test results. The general trend is one in which the forebody's maximum suction pressure peaks increase in magnitude, after their first appearance at alpha of about 19 deg, with increasing alpha. LEX pressure-distribution trends involve the inward progression of the maximum suction peaks, an increase in the magnitude of the maximum pressure peaks up to pressure core breakdown, and the decrease and general flattening of the pressure distribution beyond the LEX primary vortex breakdown.

Fisher, David F.↗

Cu penetration into low-k dielectric during deposition and bias-temperature stress

Cu penetration into low-k dielectrics can cause serious reliability issues in on-chip interconnect systems. Using secondary ion mass spectrometry with both front-side and back-side depth profiling strategies, Cu was found to diffuse into SiCOH low-k dielectric in a Cu/SiCOH/Si capacitor during Cu deposition. After bias-temperature stressing the capacitor at 270 deg. C and 2.5 MV/cm, Cu penetrates further into SiCOH, but its distribution profile is the same as that after the same temperature annealing without electrical bias, suggesting no Cu ion drift. The implication of these findings on the Cu/low-k dielectric time-dependent dielectric breakdown modeling is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of artificial aging on corrosion of abraded Al-Zn-Mg-Cu alloys

Surface abrasion has been shown to create altered surface layers (ASLs) that are hundreds of nm thick on all types of Al alloys. Such ASLs have lower corrosion resistance than the underlying substrate of Al-Zn-Mg-Cu alloys. Here, we demonstrate how heat treatments affect the ASL microstructure on abraded Al-Zn-Mg-Cu alloys using transmission electron microscopy and atom probe tomography, and also how the corrosion properties change using electrochemical polarization. Additionally, high temperature treatments on the abraded bulk samples enhance η phase precipitation in the ASL, leading to a decreased Zn content in the ASL solid solution, which ennobles the ASL breakdown potential.

36 MATERIALS SCIENCE↗

Improvement of adhesion and barrier properties of biomedical stainless steel by deposition of YSZ coatings using RF magnetron sputtering

The AISI 316L stainless steel (SS) has been widely used in both artificial knee and hip joints in biomedical applications. In the present study, yttria stabilized zirconia (YSZ, ZrO{sub 2} + 8% Y{sub 2}O{sub 3}) films were deposited on AISI 316L SS by radio-frequency magnetron sputtering using different power densities (50–250 W) and deposition times (30–120 min) from a YSZ target. The crystallographic orientation and surface morphology were studied using X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The effects of the surface modification on the corrosion performance of AISI 316L SS were evaluated in phosphate buffered saline (PBS) solution using an electrochemical test on both the virgin and coated samples. The YSZ coatings have a (111) preferred orientation during crystal growth along the c-axis for short deposition times (30–60 min), whereas a polycrystalline structure forms during deposition times from 90 to 120 min. The corrosion protective character of the YSZ coatings depends on the crystal size and film thickness. A significant increase in adhesion and corrosion resistance by at least a factor of 46 and a higher breakdown potential were obtained for the deposited coatings at 200 W (120 min). - Highlights: • Well-formed and protective YSZ coatings were achieved on AISI 316L SS substrates. • Films grown at high power and long deposition time have polycrystalline structures. • The crystal size varies from ∼ 5 to 30 nm as both power and deposition time increased. • The differences of corrosion resistance are attributed to internal film structure.

36 MATERIALS SCIENCE↗

Proof-of-concept experiment for on-line laser induced breakdown spectroscopy analysis of impurity layer deposited on optical window and other plasma facing components of Aditya tokamak

In the present manuscript, we demonstrate the design of an experimental setup for on-line laser induced breakdown spectroscopy (LIBS) analysis of impurity layers deposited on specimens of interest for fusion technology, namely, plasma-facing components (PFCs) of a tokamak. For investigation of impurities deposited on PFCs, LIBS spectra of a tokamak wall material like a stainless steel sample (SS304) have been recorded through contaminated and cleaned optical windows. To address the problem of identification of dust and gases present inside the tokamak, we have shown the capability of the apparatus to record LIBS spectra of gases. A new approach known as “back collection method” to record LIBS spectra of impurities deposited on the inner surface of optical window is presented.

42 ENGINEERING↗

Magnetoresistance Scaling Reveals Symmetries of the Strongly Correlated Dynamics in BaFe 2 ( As 1 - x P x ) 2

The phenomenon of T-linear resistivity commonly observed in a number of strange metals has been widely seen as evidence for the breakdown of the quasiparticle picture of metals. This study shows that a recently discovered H/T scaling relationship in the magnetoresistance of the strange metal BaFe 2 (As 1- x P x ) 2 is independent of the relative orientations of current and magnetic field. Rather, its magnitude and form depend only on the orientation of the magnetic field with respect to a single crystallographic axis: the direction perpendicular to the magnetic iron layers. In this work, this finding suggests that the magnetotransport scaling does not originate from the conventional averaging or orbital velocity of quasiparticles as they traverse a Fermi surface, but rather from dissipation arising from two-dimensional correlations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydrogen isotope analysis in W-tiles using fs-LIBS

Abstract Laser-Induced Breakdown Spectroscopy (LIBS) is a promising technology for in-situ analysis of Plasma-Facing Components in magnetic confinement fusion facilities. It is of major interest to monitor the hydrogen isotope retention i.e. tritium and deuterium over many operation hours to guarantee safety and availability of the future reactor. In our studies we use ultraviolet femtosecond laser pulses to analyze tungsten (W) tiles that were exposed to a deuterium plasma in the linear plasma device PSI-2, which mimics conditions at the first wall. A high-resolution spectrometer is used to detect the Balmer- $$\alpha$$ α transition of the surface from implanted hydrogen isotopes (H and D). We use Calibration Free CF-LIBS to quantify the amount of deuterium stored in W. This proof-of-principle study shows the applicability of femtosecond lasers for the detection of low deuterium concentration as present in first wall material of prevailing fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Life sciences research using a lunar laboratory

The necessity for life sciences research on the lunar surface in order to determine the consequences of returning from extended missions in various low gravity environments and of transiting through high multiple gravity forces during decelerations is discussed. The functions of a lunar gravitational biology laboratory are outlined. Lunar science objectives include investigations in developmental biology including the evaluation of the capacity of diverse organisms to undergo normal development and the evaluation of the use of the lunar environment to study specific developmental phenomena in ways that cannot be accomplished by earth-based research. The need for musculoskeletal studies to examine the dynamics of osteoclast and osteoblast formation and breakdown and to address bone and demineralization problems is discussed. Biological adaptation to hypogravic environments and the effects of radiation and electromagnetic environmental factors are also considered.

Cipriano, Leonard F.↗

Using ISCCP Weather States to Decompose Cloud Radiative Effects

The presentation will examine the shortwave (SW) and longwave (LW) cloud radiative effect CRE (aka "cloud radiative forcing") at the top-of-the-atmosphere and surface of ISCCP weather states (aka "cloud regimes") in three distinct geographical zones, one tropical and two mid-latitude. Our goal is to understand and quantify the contribution of the different cloud regimes to the planetary radiation budget. In the tropics we find that the three most convectively active states are the ones with largest SW, LW and net TOA CRE contributions to the overall daytime tropical CRE budget. They account for 59%, 71% and 55% of the total CRE, respectively. The boundary layer-dominated weather states account for only 34% of the total SW CRE and 41% of the total net CRE, so to focus only on them in cloud feedback studies may be imprudent. We also find that in both the northern and southern midlatitude zones only two weather states, the first and third most convectively active with large amounts of nimbostratus-type clouds, contribute ",40% to both the SW and net TOA CRE budgets, highlighting the fact that cloud regimes associated with frontal systems are not only important for weather (precipitation) but also for climate (radiation budget). While all cloud regimes in all geographical zones have a slightly larger SFC than TOA SW CRE, implying cooling of the surface and slight warming of the atmosphere, their LW radiative effects are more subtle: in the tropics the weather states with plentiful high clouds warm the atmosphere while those with copious amounts of low clouds cool the atmosphere. In both midlatitude zones only the weather states with peak cloud fractions at levels above 440 mbar warm the atmosphere while all the rest cool it. These results make the connection of the contrasting CRE effects to the atmospheric dynamics more explicit - "storms" tend to warm the atmosphere whereas fair weather clouds cool it, suggesting a positive feedback of clouds on weather systems. The breakdown of CRE by cloud regime are however not entirely similar between the two midlatitude zones. Despite the existence of an additional state in the nort!lern midlatitudes, only four weather states have net daytime CREs with absolute values above 100 Watts per square meter compared to six in the south. This reminds us that the environment where clouds occur also has a crucial role in determining their radiative effects. All the above make evident that reproducing grand averages of current CRE by climate models in only part of the challenge. If existing cloud regimes and shifts in their distributions and frequency of occurrence in a changed climate are not properly simulated, the radiative role of clouds will not be adequately predicted.

Oreopoulos, L.↗

Reference Model 4 Cost Breakdown (RM4: Ocean Current Turbine)

Contains the Reference Model 4 (RM4) spreadsheets with the cost breakdown structure (CBS) for the levelized cost of energy (LCOE) calculations for a single RM4 device and multiple unit arrays. These spreadsheets are contained within an XLSX file and a spreadsheet editor such as Microsoft Excel is needed to open the file. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 4 (RM4) is a flying-wing ocean current turbine concept intended for deployment in the Gulf Stream off the southeast coast of Florida. The RM4 device has four rotors, with a rotorless center nacelle housing the power electronics, attached on a straight wing 120 m long. The device is designed to be submerged ~50 m below the surface and is moored to the seabed. The RM4 uses buoyancy within the wing and the five nacelles to maintain its position in the water column. Each rotor has a diameter of 33 m and has a 1-MW power rating, yielding a total device rated power of 4 MW. The rotors on the left and right side of the wing rotate in opposite directions in order to balance the torque applied to the device. The rotorless center nacelle housing the power electronics serves to condition the power generated by the rotors before it is delivered to the grid.

16 TIDAL AND WAVE POWER↗

Surface pressure distributions on a delta wing undergoing large amplitude pitching oscillations

Wind tunnel experiments were performed on a 70 deg sweep delta wing to determine the effect of a sinusoidal pitching motion on the pressure field on the suction side of the wing. Twelve pressure taps were placed from 35 to 90 percent of the chord, at 60 percent of the local semi-span. Pressure coefficients were measured as a function of Reynolds number and pitch rate. The pressure coefficient was seen to vary at approximately the same frequency as the pitching frequency. The relative pressure variation at each chord location was comparable for each case. The average pressure distribution through each periodic motion was near the static distribution for the average angle of attack. Upon comparing the upstroke and downstroke pressures for a specific angle of attack, the downstroke pressures were slightly larger. Vortex breakdown was seen to have the most significant effect at the 40 to 45 percent chord location, where a decrease in pressure was apparent.

Thompson, Scott A.↗

Pronounced reduction in the regeneration energy of potassium sarcosinate CO 2 capture solvent using TiO 2

Absorption-based CO 2 capture technologies face economic feasibility concerns due to the exceedingly high energy requirements of solvent regeneration. Among various proposed solutions, solid acid-aided solvent regeneration stands out as a promising approach. Studies have shown that solid materials containing Lewis and Brønsted acid sites can facilitate deprotonation of protonated amine and breakdown of carbamate molecules, which significantly increases CO 2 desorption rate and decreases regeneration energy of common solvents such as MEA and DEA. However, the influence of solid acids on alternate solvents such as amino acids is not well known. Here, we report the performance of TiO 2 for the regeneration of CO 2 -loaded aqueous potassium sarcosinate (K-Sar) solvent. K-Sar is an environmentally friendly amino-acid salt that provides high CO 2 absorption rates, making it a good candidate for both point-source and direct-air capture. TiO 2 is hydrothermally stable and contains high surface acid site concentration. Desorption of CO 2 from K-Sar starts at room temperature in the presence of TiO 2 , while such onset temperature is greater than 70°C for regeneration without TiO 2 . Further, at a temperature of 95°C, the maximum CO 2 desorption rate and cumulative CO 2 removal increase by 128% and 91%, respectively, in the presence of TiO 2 compared to the no TiO 2 case. The total regeneration energy could be reduced by ~ 50% with TiO 2 , showcasing the significant role this process can take in improving the commercial competitiveness of absorption-based CO 2 capture. Further characterization with XRD, SEM, and NMR concluded that neither the TiO 2 powder nor the solvent undergoes any physical or chemical degradation in the regeneration process, suggesting the potential of their long-term usability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Walker Breakdown with a Twist: Dynamics of Multilayer Domain Walls and Skyrmions Driven by Spin-Orbit Torque

Current-induced dynamics of twisted domain walls and skyrmions in ferromagnetic perpendicularly magnetized multilayers is studied through three-dimensional micromagnetic simulations and analytical modeling. In this work, it is shown that such systems generally exhibit a Walker-breakdown-like phenomenon in the presence of a current-induced dampinglike spin-orbit torque. Above a critical current threshold, corresponding to typical velocities of the order of tens of m/s, domain walls in some layers start to precess with frequencies in the gigahertz regime, which leads to oscillatory motion and a significant drop in mobility. This phenomenon originates from complex stray field interactions and occurs for a wide range of multilayer materials and structures that include at least three ferromagnetic layers and finite Dzyaloshinskii-Moriya interaction. An analytical model is developed to describe the precessional dynamics in multilayers with surface-volume stray field interactions, yielding qualitative agreement with micromagnetic simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic probe measurements of the current sheath on the PF-3 facility

Results are presented from experimental studies of the dynamics of the current sheath (CS) on the PF-3 plasma focus facility. The parameters of the sheath, including the current distribution in it, were measured using absolutely calibrated magnetic probes installed at different positions with respect to the facility axis and the anode surface. The CS dynamics in discharges operating in argon and neon was investigated, and the skin depth in different stages of the discharge was determined. One of the probes was installed at a distance of {approx}2 cm from the facility axis, which made it possible to estimate the efficiency of current transfer to the region of pinch formation. Operating modes were obtained in which the current dynamics detected by magnetic probes at different distances from the axis agreed well with the dynamics of the total discharge current until the instant of singularity in the current time derivative. It is shown that shunting breakdowns can lead to the formation of closed current loops. The shunting of the discharge current by the residual plasma is directly related to the efficiency of snowplowing of the working gas by the CS as it propagates from the insulator toward the facility axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

General Services Administration Reclamation Yard (SWMU 010) 2020-2021 Groundwater Monitoring Report

This report presents a summary of the groundwater monitoring activities that occurred from October 2020 through June 2021 at General Services Administration Reclamation Yard, Solid Waste Management Unit 010, located at the John F. Kennedy Space Center (KSC), Florida. For the purposes of this report, two separate plumes, known as the Polychlorinated Biphenyl (PCB)/Volatile Organic Aromatic (VOA) Plume and the Chlorinated Volatile Organic Compound (VOC) Plume were identified for this site. The contaminants of concern (COCs) for the PCB/VOA Plume consists of PCBs, 1,2,4-trichlorobenzene, and breakdown products of 1,2,4-trichlorobenzene. The COCs for the Chlorinated VOC Plume are tetrachloroethene, trichloroethene, cis-1,2-dichloroethene, and vinyl chloride. The activities presented in this report include four field events: (1) October 2020 – Chlorinated VOC Plume groundwater sampling via Direct Push Technology (DPT) – 68 groundwater samples were collected from 14 locations at varying intervals; (2) December 2020 – Site-wide semi-annual water level measurements of 52 monitoring wells and sampling of 39 monitoring wells; (3) May 2021 – Chlorinated VOC Plume monitoring well installation – two monitoring wells were installed and screened from 10 to 20 feet below land surface (bls); and (4) May/June 2021 – Site-wide semi-annual water level measurements of 53 monitoring wells and sampling of 40 monitoring wells. Results showed substantial reduction of both plumes. Conclusions and recommendations are presented.

VOC↗

Defect-mediated diffusion of implanted Mg in GaN: Suppressing dopant redistribution by sequential thermal and microwave annealing

The diffusion behavior of Mg in Mg/N co-implanted GaN is investigated in response to a set of annealing conditions and methodologies, namely, 1000 °C/30 min thermal anneal, by high-temperature pulsed gyrotron microwave annealing at 1420 or 1500 °C, or by thermal and microwave annealing, sequentially. After 1000 °C annealing, the diffusion of Mg in GaN is found to be negligible, as measured by secondary ion mass spectrometry. Annealing by gyrotron microwave annealing alone induces the diffusion of Mg at a rate on the order of 10 −12 cm 2 /s. However, the use of a thermal anneal before microwave gyrotron annealing reduces this rate by an order of magnitude to 10 −13 cm 2 /s. We find that a model that considers Mg diffusion from an inhomogeneous medium that contains a defect-rich implanted region near-surface to a relatively pristine region below the implant range better explains the observed diffusion behavior than a conventional model that assumes a homogeneous medium. By analyzing the diffusion behavior using the Boltzmann–Matano method, we present a discussion of reduction in [V Ga ] by thermal annealing at 1000 °C, leading to a suppressed diffusion coefficient during subsequent high-temperature annealing relative to diffusion after 1420/1500 °C annealing alone. This effect holds potential for improvement in the precision of selectively doped regions for future applications based on the (Al)GaN material system. An improved field profile control in real devices can increase the breakdown and current-handling capabilities in power electronic applications.

Meyers, V.↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

In-situ SiN{sub x}/InN structures for InN field-effect transistors

Critical aspects of InN channel field-effect transistors (FETs) have been investigated. SiN{sub x} dielectric layers were deposited in-situ, in the molecular beam epitaxy system, on the surface of 2 nm InN layers grown on GaN (0001) buffer layers. Metal-insulator-semiconductor Ni/SiN{sub x}/InN capacitors were analyzed by capacitance-voltage (C-V) and current-voltage measurements and were used as gates in InN FET transistors (MISFETs). Comparison of the experimental C-V results with self-consistent Schrödinger-Poisson calculations indicates the presence of a positive charge at the SiN{sub x}/InN interface of Q{sub if} ≈ 4.4 – 4.8 × 10{sup 13 }cm{sup −2}, assuming complete InN strain relaxation. Operation of InN MISFETs was demonstrated, but their performance was limited by a catastrophic breakdown at drain-source voltages above 2.5–3.0 V, the low electron mobility, and high series resistances of the structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗