Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Absorption Mode FT-ICR Mass Spectrometry Imaging

Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here we present the first use of absorption mode for Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image and then these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode ?Datacubes? for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.

Environmental Molecular Sciences Laboratory↗

Monte Carlo simulations of photoneutron activation in a medical LINAC

The first step of the present study was to simulate the γ-radioactivity produced by photoneutrons in the treatment head of a decommissioned medical LINAC. These results, obtained with MCNPX and CINDER'90, are then compared with γ-ray spectrometric measurements of parts of the treatment head. Our ultimate objective is to simulate the associated production by photonuclear reactions of pure β-emitters, which are more difficult to access experimentally than the γ-ray emitters. (authors)

43 PARTICLE ACCELERATORS↗

Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complex Method of Non-Destructive Measurements of Plutonium Composition and Mass

A complex method of performing non-destructive measurements of the isotopic composition and mass of plutonium that does not require external data on {sup 242}Pu content is described. The method includes a set of measurements performed by means of γ-spectrometry, calorimetry, and neutron multiplicity. Determinations of the metrological characteristics showed that in terms of accuracy it greatly surpasses the existing analogues, approaching the coulometric and isotopic dilution methods. The method is recommended for use in the industrial production of mixed uranium-plutonium fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The METLIN small molecule dataset for machine learning-based retention time prediction

Machine learning has been extensively applied in small molecule analysis to predict a wide range of molecular properties and processes including mass spectrometry fragmentation or chromatographic retention time. However, current approaches for retention time prediction lack sufficient accuracy due to limited available experimental data. Here we introduce the METLIN small molecule retention time (SMRT) dataset, an experimentally acquired reverse-phase chromatography retention time dataset covering up to 80,038 small molecules. To demonstrate the utility of this dataset, we deployed a deep learning model for retention time prediction applied to small molecule annotation. Results showed that in 70% of the cases, the correct molecular identity was ranked among the top 3 candidates based on their predicted retention time. We anticipate that this dataset will enable the community to apply machine learning or first principles strategies to generate better models for retention time prediction.

59 BASIC BIOLOGICAL SCIENCES↗

Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors

Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of the detection of trace elements in particulate matter using online High-Resolution Aerosol Mass Spectrometry

The feasibility of using an online thermal-desorption electron-ionization high-resolution aerosol mass spectrometer (AMS) for the detection of particulate trace elements was investigated analyzing data from Mexico City obtained during the MILAGRO 2006 field campaign, where relatively high concentrations of trace elements have been reported. This potential application is of interest due to the real-time data provided by the AMS, its high sensitivity and time resolution, and the widespread availability and use of this instrument. High resolution mass spectral analysis, isotopic ratios, and ratios of different ions containing the same elements are used to constrain the chemical identity of the measured ions. The detection of Cu, Zn, As, Se, Sn, and Sb is reported. There was no convincing evidence for the detection of other trace elements commonly reported in PM. The elements detected tend to be those with lower melting and boiling points, as expected given the use of a vaporizer at 600oC in this instrument. Operation of the AMS vaporizer at higher temperatures is likely to improve trace element detection. The detection limit is estimated at approximately 0.3 ng m-3 for 5-min of data averaging. Concentration time series obtained from the AMS data were compared to concentration records determined from offline analysis of particle samples from the same times and locations by ICP (PM2.5) and PIXE (PM1.1 and PM0.3). The degree of correlation and agreement between the three instruments (AMS, ICP, and PIXE) varied depending on the element. The AMS shows promise for real-time detection of some trace elements, although additional work including laboratory calibrations with different chemical forms of these elements are needed to further develop this technique and to understand the differences with the ambient data from the other techniques. The trace elements peaked in the morning as expected for primary sources, and the many detected plumes suggest the presence of multiple point sources, probably industrial, in Mexico City which are variable in time and space, in agreement with previous studies.

99 GENERAL AND MISCELLANEOUS↗

Structural differences between single crystal and polycrystalline UBe 13

Here, we report on observations of structural and chemical differences between samples of UBe 13 that were synthesised using two different methods. Unexplained discrepancies in properties between samples with differing synthesis had previously been found in this heavy fermion superconductor. A polycrystalline UBe 13 sample was made by arc-melting the constituents. Single crystals were grown using an aluminium flux and had a consistently slightly larger lattice parameter than the polycrystals, which merited further study. Neutron diffraction data were collected at the Lujan Center at LANSCE on the HIPPO diffractometer. Aluminium was detected by inductively coupled plasma mass spectrometry (ICP-MS) in the flux-grown single crystal (0.803 wt%), and small amounts (~0.2 wt%) of thorium were detected in the UBe 13 polycrystalline sample. In order to probe the implications of the presence of Al, calculations by spin-polarised DFT-GGA+U show that the incorporation of Al onto the 96i site (the lowest symmetry site in the structure) is energetically more favourable than on other sites. In general, the trends calculated by DFT for bond lengths and lattice parameter increases are consistent with bond lengths experimentally observed by neutron diffraction, but specific percentage changes with aluminium incorporation may be obscured by the unexpected thorium in the polycrystalline sample. The aggregate of our initial observations suggests that incorporation of aluminium from the flux into single crystal UBe 13 is significant.

36 MATERIALS SCIENCE↗

Air Monitoring of Emissions from the Fukushima Daiichi Reactor

In response to the disasters in Japan on March 11, 2011, and the subsequent emissions from Fukushima-Daiichi, we monitored the air near Los Alamos using four air-monitoring systems: the standard AIRNET samplers, the standard rad-NESHAP samplers, the NEWNET system, and high-volume air samplers. Each of these systems has advantages and disadvantages. In combination, they provide a comprehensive set of measurements of airborne radionuclides near Los Alamos during the weeks following March 11. We report air-monitoring measurements of the fission products released from the Fukushima-Daiichi nuclear-power-plant accident in 2011. Clear gamma-spectrometry peaks were observed from Cs-134, Cs-136, Cs-137, I-131, I132, Te-132, and Te-129m. These data, together with measurements of other radionuclides, are adequate for an assessment and assure us that radionuclides from Fukushima Daiichi did not present a threat to human health at or near Los Alamos. The data demonstrate the capabilities of the Los Alamos air-monitoring systems.

54 ENVIRONMENTAL SCIENCES↗

The Mars reference atmosphere

A nominal atmospheric model of Mars is presented, with detailed consideration being given to the various sources of variability in the Martian atmosphere. A basic model for the midlatitude summer is outlined for the northern and southern hemispheres. Attention is given to meteorological variability due to winds, diurnal and seasonal pressure variations, temperature changes, and the effects of dust opacity, particularly on temperature stratification. Viking lander IR thermal mapper data are examined in terms of diurnal and latitudinal temperature variations, and cloud and haze formation and locations are discussed. Mass spectrometry of the atmosphere is used to describe the molecular abundances, and water vapor measurements are reviewed. Finally, radio occultation, UV airglow, and mass spectrometry of the Martian upper atmosphere are investigated, along with the temperature structure of the upper atmosphere.

Kliore, A.↗

Processing of extraterrestrial materials by high temperature vacuum vaporization

It is noted that problems associated with the extraction and concentration of elements and commpounds important for the construction and operation of space habitats have received little attention. High temperature vacuum vaporization is considered a promising approach; this is a technique for which the space environment offers advantages in the form of low ambient pressures and temperatures and the possibility of sustained high temperatures via solar thermal energy. To establish and refine this new technology, experimental determinations must be made of the material release profiles as a function of temperature, of the release kinetics and chemical forms of material being transported, and of the various means of altering release kinetics. Trace element data determined by neutron activation analysis of meteorites heated to 1400 C in vacuum is summarized. The principal tool, high temperature spectrometry, is used to examine the vaporization thermodynamics and kinetics of major and minor elements from complex multicomponent extraterrestrial materials.

Grimley, R. T.↗

Solar cosmic ray produced neon in lunar soils and their implication for gas-rich meteorite studies

Characteristic neon isotopic ratios, produced due to solar cosmic ray spallation (SCR) in lunar soils, are useful in deciphering and estimating the relative contributions of SCR and GCR spallation. To delineate these features, etched mineral grains from mature and immature lunar soils (14148 and 61221 respectively) were analyzed using mass spectrometry. The SF-Ne composition deduced in this work agrees with that obtained from earlier etched lunar pyroxene studies. The data points for mature soil 14148 define a line which significantly deviates from the 61221 tie line. This deviation is attributed to the presence of SCR spallation component. In this context, neon isotopic compositions (step-wise heating) in Pantar and Leighton dark portions were studied and compared with that of Fayetteville. The meteorite data points deviate significantly from the tie line joining SF-Ne and GCR (pyroxene) end points. This deviation is attributed to SCR-spallation in gas-rich chondrites.

Nautiyal, C. M.↗

Volatiles in interplanetary dust particles

Interplanetary dust particles (IDP's) collected by specially equipped aircraft flying in the stratosphere have generated a lot of interest during the last decade. These particles, consisting of primitive materials originating in small solar system bodies such as comets and asteroids, are complex heterogeneous species with a variety of components. In order to understand the past histories of IDP's, it is particularly important to know the nature of the volatiles present. Volatiles released from a number of IDP's have been studied; however, a large number of particles must be studied in order to establish trends, to classify types of IDP's, and to have comparison data for determining the origins of IDP's. This study involves the analysis of six IDP's using laser microprobe mass spectrometry.

Bustin, Roberta↗

Volcanic Gas Emissions Mapping Using a Mass Spectrometer System

The visualization of hazardous gaseous emissions at volcanoes using in-situ mass spectrometry (MS) is a key step towards a better comprehension of the geophysical phenomena surrounding eruptive activity. In-Situ gas data consisting of helium, carbon dioxide, sulfur dioxide, and other gas species, were acquired with an MS system. MS and global position system (GPS) data were plotted on ground imagery, topography, and remote sensing data collected by a host of instruments during the second Costa Rica Airborne Research and Technology Applications (CARTA) mission This combination of gas and imaging data allowed 3-dimensional (3-D) visualization of the volcanic plume end the mapping of gas concentration at several volcanic structures and urban areas This combined set of data has demonstrated a better tool to assess hazardous conditions by visualizing and modeling of possible scenarios of volcanic activity. The MS system is used for in-situ measurement of three-dimensional gas concentrations at different volcanic locations with three different transportation platforms, aircraft, auto, and hand carried. The demonstration for urban contamination mapping is also presented as another possible use for the MS system.

Griffin, Timothy P.↗

Comparing Analysis of Hydrogen Concentration in Astromaterials Nominally Anhydrous Minerals by Multiple SIMS

Secondary Ion Mass Spectrometry (SIMS) is utilized to determine hydrogen (H) concentration in astromaterials nominally anhydrous minerals (NAMs) and their inclusions [e.g., 1]. This data is interpreted to refine the volatile history of planetary bodies. Four instruments are being used to compare H concentration analysis: a large geometry SIMS (The University of Hawaiʻi Cameca IMS 1280), a compact SIMS (Arizona State University (ASU) Cameca IMS 6f), and two Cameca NanoSIMS 50L at ASU and NASA-Johnson Space Center (JSC). Results on the first three instruments are available. Although fundamentally similar, SIMS instruments and their modifications [2] may produce different values or pose advantages for H analysis, especially for shocked samples that are susceptible to contamination filling their fractures. New data from the IMS 1280 is reported, using its microchannel plate (MCP) to image high H signals in grain fractures during pre-sputtering to avoid them as much as possible. Between fractures, 16 OH/ 30 Si was measured with a Cs + 4 nA primary beam, 30 micron spot size, and central ~5x5 micron collection area. First order comparison of H concentration (reported in ppm H 2 O) is achieved on a terrestrial gem quality clinopyroxene (SLP114, 162±12 ppm H 2 O [3]), with 157±7 and 215±40 ppm H 2 O by the IMS 1280 and 6f respectively. SIMS comparison is then extended to analysis of two Martian shergottites: RBT 04262 and NWA 5789. Due to a dense fracture network (< 20 micron) in RBT 04262, only one clinopyroxene hosted glassy inclusion was analyzed (n=6, ≤1 ppm H 2 O), while six olivine grains in NWA 5789 (n=12, ≤ 2 ppm H 2 O) (1s ±0.21) were analyzed. Higher concentrations were obtained for RBT 04262 olivine by the ASU NanoSIMS 50L (up to 350 ppm H 2 O [4]), and IMS 6f (300+ ppm H 2 O, [5]), for which contamination in fractures could not be avoided. Work on the JSC NanoSIMS 50L will further develop the SIMS comparison.

J.-M. Dudley↗

Study of the Melting Latent Heat of Semicrystalline PVDF applied to High Gamma Dose Dosimetry

Poly(vinylidene fluoride) homopolymers [PVDF] homopolymers were irradiated with gamma doses ranging from 0.5 to 2.75 MGy. Differential scanning calorimetry (DSC) and FTIR spectrometry were used in order to study the effects of gamma radiation in the amorphous and crystalline polymer structures. The FTIR data revealed absorption bands at 1730 and 1853 cm{sup -1} which were attributed to the stretch of C=O bonds, at 1715 and 1754 cm{sup -1} which were attributed to the C=C stretching and at 3518, 3585 and 3673 cm{sup -1} which were associated with NH stretch of NH{sub 2} and OH. The melting latent heat (LM) measured by DSC was used to construct an unambiguous relationship with the delivered dose. Regression analyses revealed that the best mathematical function that fits the experimental calibration curve is a 4-degree polynomial function, with an adjusted Rsquare of 0.99817. (authors)

36 MATERIALS SCIENCE↗

A Statistical Framework for Protein Quantitation in Bottom-Up MS-Based Proteomics

Motivation: Quantitative mass spectrometry-based proteomics requires protein-level estimates and associated confidence measures. Challenges include the presence of low quality or incorrectly identified peptides and informative missingness. Furthermore, models are required for rolling peptide-level information up to the protein level. Results: We present a statistical model that carefully accounts for informative missingness in peak intensities and allows unbiased, model-based, protein-level estimation and inference. The model is applicable to both label-based and label-free quantitation experiments. We also provide automated, model-based, algorithms for filtering of proteins and peptides as well as imputation of missing values. Two LC/MS datasets are used to illustrate the methods. In simulation studies, our methods are shown to achieve substantially more discoveries than standard alternatives. Availability: The software has been made available in the opensource proteomics platform DAnTE (http://omics.pnl.gov/software/). Contact: adabney@stat.tamu.edu Supplementary information: Supplementary data are available at Bioinformatics online.

59 BASIC BIOLOGICAL SCIENCES↗