Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

SU-E-T-87: Comparison Study of Dose Reconstruction From Cylindrical Diode Array Measurements, with TLD Measurements and Treatment Planning System Calculations in Anthropomorphic Head and Neck and Lung Phantoms

Purpose: To assess dose calculated by the 3DVH software (Sun Nuclear Systems, Melbourne, FL) against TLD measurements and treatment planning system calculations in anthropomorphic phantoms. Methods: The IROC Houston (RPC) head and neck (HN) and lung phantoms were scanned and plans were generated using Eclipse (Varian Medical Systems, Milpitas, CA) following IROC Houston procedures. For the H and N phantom, 6 MV VMAT and 9-field dynamic MLC (DMLC) plans were created. For the lung phantom 6 MV VMAT and 15 MV 9-field dynamic MLC (DMLC) plans were created. The plans were delivered to the phantoms and to an ArcCHECK (Sun Nuclear Systems, Melbourne, FL). The head and neck phantom contained 8 TLDs located at PTV1 (4), PTV2 (2), and OAR Cord (2). The lung phantom contained 4 TLDs, 2 in the PTV, 1 in the cord, and 1 in the heart. Daily outputs were recorded before each measurement for correction. 3DVH dose reconstruction software was used to project the calculated dose to patient anatomy. Results: For the HN phantom, the maximum difference between 3DVH and TLDs was -3.4% and between 3DVH and Eclipse was 1.2%. For the lung plan the maximum difference between 3DVH and TLDs was 4.3%, except for the spinal cord for which 3DVH overestimated the TLD dose by 12%. The maximum difference between 3DVH and Eclipse was 0.3%. 3DVH agreed well with Eclipse because the dose reconstruction algorithm uses the diode measurements to perturb the dose calculated by the treatment planning system; therefore, if there is a problem in the modeling or heterogeneity correction, it will be carried through to 3DVH. Conclusion: 3DVH agreed well with Eclipse and TLD measurements. Comparison of 3DVH with film measurements is ongoing. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

Importance Ranking of Software Dependability Attributes in the Nuclear Industry

With the current transition from analog to digital instrumentation and control systems in nuclear power plants, the number and variety of software-based systems has significantly increased. Due to the sophisticated nature and the increasing complexity of software, a significant challenge faced by the nuclear industry is the trust one can place in software-based systems once they have been developed. The trust placed in software is typically termed software dependability, a qualifier which encompasses different attributes such as software reliability, safety, security, availability and maintainability. It is recognized that these attributes relate to each other in different ways under various scenarios. The detailed dependencies between software dependability attributes can be found in a previous study. With limited time and budget resources, which dependability attribute should be given the highest priority when certifying software-based systems in the nuclear industry is a fundamental question that needs to be answered. This paper addresses this problem using stakeholders' opinion elicitation. A comprehensive questionnaire was designed to elicit the goals that should be fulfilled by the nuclear industry and to collect the relative importance of the various dependability attributes for each goal. We then used the Analytical Hierarchy Process (AHP) to analyze the data and obtained the relative importance ranking of software dependability attributes in the context of a reactor protection system. The results will provide guidance to resource allocation for the certification of software dependability in the nuclear industry. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linac-based on-board imaging feasibility and the dosimetric consequences of head roll in head-and-neck IMRT plans

Kilovoltage imaging systems on linear accelerators are used for patient localization in many clinics. The purpose of this work is to assess on-board imaging (OBI) detection of systematic setup errors and in particular, the dosimetric consequences of undetected head roll in head-and-neck intensity modulated radiation therapy (IMRT) plans when using these systems. The system used in this study was the Trilogy linear accelerator and associated software (Varian Medical Systems, Palo Alto, CA). Accuracy of OBI localization was evaluated using an anthropomorphic head phantom. The head phantom is rigidly attached to a specially designed positioning device with 5 deg. of freedom, 3 translational and 2 rotational in the axial and coronal planes. Simulated setup errors were 3 deg. and 5 deg. rotations in the axial plane and displacements of 5 mm in the left-right, anterior-posterior, and superior-inferior directions. The coordinates set by the positioning device were compared with the coordinates obtained as measured by using the image matching tools of paired 2-dimensional (2D) orthogonal image matching, and 3D cone-beam computed tomography (CT) volume matching. In addition, 6 physician-approved IMRT plans of nasopharynx and tonsil carcinoma were recalculated to evaluate the impact of undetected 3 deg. and 5 deg. head roll. Application of cone-beam CT (CBCT) for patient localization was superior to 2D matching techniques for detecting rotational setup errors. The use of CBCT allowed the determination of translational errors to within 0.5 mm, whereas kV planar was within 1 to 2 mm. Head roll in the axial plane was not easily detected with orthogonal image sets. Compared to the IMRT plans with no head roll, dose-volume histogram analysis demonstrated an average increase in the maximal spinal cord dose of 3.1% and 6.4% for 3 deg. and 5 deg. angles of rotation, respectively. Dose to the contralateral parotid was unchanged with 3 deg. roll and increased by 2.7% with 5 deg. roll. The results of this study show that volumetric setup verification using CBCT can improve bony anatomy setup detection to millimeter accuracy, and is a reliable method to detect head roll. However, the magnitude of possible dose errors due to undetected head roll suggests that CBCT does not need to be performed on a daily basis but rather weekly or bi-weekly to ensure fidelity of the head position with the immobilization system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-PIS-Exhibit Hall-5: Use of the Enterprise-wide Dose Tracking Software Radimetrics In an Academic Medical System

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

Cyber State Awareness For Resilience

Characterization of cyber-physical attacks requires a holistic understanding of cyber and physical behavior in a system. Machine Learning Anomaly Detection provides a compelling solution for continuously identifying suspicious behavior within these complex systems. In our software, we present an approach for holistic characterization of cyber-physical systems based on cyber and physical anomaly correlation. The approach consists of three main components: 1) an architecture for real-time data acquisition, management, and analysis of both cyber and physical data; 2) cyber and physical data driven anomaly detection systems (ADSs), 3) a metric that combines cyber and physical ADSs to provide a holistic characterization of the system..

Rieger, CraigG.↗

Plug and Play PV Systems for American Homes

The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work during this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.

14 SOLAR ENERGY↗

Secure Software Defined Radio Project: Secure Wireless Systems for the Energy Sector (Briefing 6)

Strong industry interest in the SEL-FLT/FLR products has led to a large number of customers conducting various lab and field trial evaluations of the system. These trials are on-going but have allowed SEL to collect enough information about operation and deployment and security capabilities of the system to conclude the field demo phase of the project. The field-testing topical report has been completed and submitted. SEL has also prepared a SEL-FLT/FLR best practices guide based on learnings from the field demo phase of the project. This best practice guide has also been submitted. The final deliverable from this phase of the project is an economic and operational benefits white paper, which has also been written and submitted. The overall objective of the project, extending the cyber security capabilities of utility wired networks into last mile wireless networks has been successfully achieved. SEL chose to target a sensor network for implementation of this capability because it was one area of last mile networking where there was substantial need and opportunity. Based on customer interest in the product these efforts have been a success. Interest in, and support for many of the security features of the product has been expressed by customers trialing the product system. Key security features customers value are strong data encryption, sensor white listing, and use of secure account based log on for access to the system. These and other features of the product have gained strong acceptance from customers interested in purchasing these products. All project deliverables and tasks are now complete, and the project can be closed out.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Management and Storage of Scientific Data

Scientific discoveries rely heavily on efficient access, search, and management of massive data sets. Data management technologies have, for decades, provided foundational capabilities for scientific computing. Just as storage, input/output (I/O), and data management have been fundamental to simulation-based science for many years, so too are capable data-management technologies key to the success of today’s scientific workflows utilizing data intensive and machine learning (ML) techniques. The Department of Energy, Office of Science, Advanced Scientific Computing Research (ASCR) program has invested broadly in data-management research focused on high-performance computing (HPC) systems, from parallel file systems that store data to application software that makes these systems more productive. Still, advances in technology combined with growing diversity of supported science strongly motivate continued investment in this area. In January 2022, ASCR convened a workshop to identify priority research directions in the area of data management for high-performance and scientific computing. Attendees were challenged to identify promising approaches that would support the breadth of the DOE mission, including the explosion of artificial intelligence (AI) uses and the growing needs of experimental and observational science. Technological and science drivers were identified and considered as they relate to key aspects of data management such as interfaces, architectural design, and FAIR principles (Findable, Accessible, Interoperable, and Reusable). The thoughts of the workshop participants were distilled into a set of four priority research directions with the potential for high impact on DOE science. These research directions are summarized in the following pages.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

FY 2018 ARM Radar Plan

The fundamental objective of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility radar facility is to provide high-quality radar observations to the scientific user community with an overarching goal of improving the treatment of clouds and precipitation in climate models. Historically, ARM has operated zenith-profiling cloud radars at millimeter wavelengths at five of its facilities. Since 2010, 16 scanning systems have been added to the radar facility. The ARM radar facility has 33 radars in its possession at three fixed sites and three mobile facilities. A breakdown of the ARM radar assets is given below: 8 Scanning ARM Clouds Radar Systems (SACR: two radars on single pedestal; six 1st- and two 2nd- generation) 7 Ka-band ARM Zenith profiling Radar (KAZR: five 1st- and two 2nd-generation) 5 X-band Scanning ARM precipitation Radar (XSAPR: four 1st- and one 2nd-generation) 3 C-band Scanning ARM precipitation Radar (CSAPR: two 1st- and one 2nd-generation) 1 W-band ARM Cloud Radar (WACR) 1 Marine W-band ARM Cloud Radar (MWACR: configured to be deployed on a stable table or scanning pedestal). Of these radars, all but six (two SACRs [accounting for four radars], one KAZR, and one 1st-generation CSAPR) have operational assignments. Therefore, the current measurement strategy involves operating 27 radars, not including radar wind profilers (RWPs). This array of instruments represents a combination of scanning and profiling radars at ARM’s sites. In addition to the scanning capabilities, the radars at each site differ in operating frequency, technology, and complexity, but all are complex systems. Some of them were custom designed and built specifically for ARM. Typically, newer systems take a few years to reach operational maturity with adequate characterization, calibration, testing, and quality control. Due to various factors, not all of the radars have achieved an operationally mature status sufficient to provide high-quality data in a research environment. In addition, these radars are often deployed in remote locations and harsh environments to meet science needs. The remoteness of such complex systems is a considerable challenge for continuous operations. Tools needed for a research-level operational radar are not readily available from vendors, and many of the necessary system management tools, both hardware and software, to manage these systems must be developed in-house for such deployments. Based on experience over the past seven years, including conclusions from the first phase of the radar plan, implemented in mid-2016, it is clear that ARM cannot support the operation of all 27 currently deployed radars and expect to provide research-quality data (including higher-order products) with the current resources. Experience from the first phase of the radar plan has provided a better indication than has been available previously of what size radar network is reasonable. A preliminary proposal for what that radar network could look like is provided here. The plan presented here uses the available resources to best support this proposed network.

ARM Mobile Facility↗

Integrated Building Energy Systems Design Considering Storage Technologies

The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic, as well as environmental attraction of micro-generation systems (e.g., PV or fuel cells with or without CHP) and contribute to enhanced demand response. The interactions among PV, solar thermal, and storage systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of storage technologies on demand response and CO2 emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that can pursue two strategies as its objective function. These two strategies are minimization of its annual energy costs or of its CO2 emissions. The problem is solved for a given test year at representative customer sites, e.g., nursing homes, to obtain not only the optimal investment portfolio, but also the optimal hourly operating schedules for the selected technologies. This paper focuses on analysis of storage technologies in micro-generation optimization on a building level, with example applications in New York State and California. It shows results from a two-year research projectperformed for the U.S. Department of Energy and ongoing work. Contrary to established expectations, our results indicate that PV and electric storage adoption compete rather than supplement each other considering the tariff structure and costs of electricity supply. The work shows that high electricity tariffs during on-peak hours are a significant driver for the adoption of electric storage technologies. To satisfy the site's objective of minimizing energy costs, the batteries have to be charged by grid power during off-peak hours instead of PV during on-peak hours. In contrast, we also show a CO2 minimization strategy where the common assumption that batteries can be charged by PV can be fulfilled at extraordinarily high energy costs for the site.

25 ENERGY STORAGE↗

Summer 2024 INL Intern Poster Session Submission - Brian Schumitz

This LRS submission is my poster for the INL Intern Poster Session, Summer 2024. Abstract: The Software Engineering and Cybersecurity Lab (SECL) at Montana State University has developed PIQUE, a system for evaluating software quality. PIQUE's adaptability allows for language-specific static-analysis operations, including a model for assessing cloud microservice ecosystems. These ecosystems often rely on Docker for efficient deployment and management of containerized services. Our research focuses on evaluating the network quality within these microservice ecosystems. To automate this process, we're utilizing Snort, an open-source intrusion detection system renowned for its ability to detect and log network traffic. By leveraging Snort's customizable rules, we aim to construct comprehensive testing methods for measuring and quantifying the network quality based on traffic between Docker containers. This research aims to enhance the overall security and reliability of cloud microservice ecosystems by providing automated and robust quality evaluation mechanisms, ultimately contributing to the advancement of software engineering practices in these environments

97 MATHEMATICS AND COMPUTING↗

Algorithm and Software for Calculating Optimal Regimes of the Process Water Supply System at the Kalininskaya NPP{sup 1}

An algorithm and software for calculating the optimal operating regimes of the process water supply system at the Kalininskaya NPP are described. The parameters of the optimal regimes are determined for time varying meteorological conditions and condensation loads of the NPP. The optimal flow of the cooling water in the turbines is determined computationally; a regime map with the data on the optimal water consumption distribution between the coolers and displaying the regimes with an admissible heat load on the natural cooling lakes is composed. Optimizing the cooling system for a 4000-MW NPP will make it possible to conserve at least 155,000 MW · h of electricity per year. The procedure developed can be used to optimize the process water supply systems of nuclear and thermal power plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗