Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Evaluation of Howard A. Hanson Dam Juvenile Fish Passage and Survival Study Live Fish Injury Assessment, Sensor Fish, and BioPA Modeling Tasks

The live fish injury assessment, Sensor Fish, and BioPA modeling study tasks were conducted by researchers from Pacific Northwest National Laboratory (PNNL). The four tasks were part of the larger Evaluation of Howard A. Hanson Dam (HAHD) Juvenile Fish Passage and Survival study, which had six total tasks. To achieve study objectives for each of the four tasks, field work occurred at Green Peter Dam (GPR) to evaluate the highest elevation steep slope bypass pipe, at HAHD to evaluate baseline conditions of the horseshoe tunnel, and at PNNL’s Aquatic Research Laboratory (ARL) to evaluate simulated dam passage conditions (i.e., shear forces and collision). Each of these evaluations utilized live fish injury assessment, Sensor Fish, and BioPA modeling. Live fish injury assessment and survival (tagged with and without balloon or passive integrated transponder [PIT] tags) was correlated with Sensor Fish to determine thresholds. The CFD analyses were then performed, and the computed values were compared to the corresponding measured values of Sensor Fish data. The results of the overall injury and survival of fish was also used in the validation of the CFD modeling method. Collectively, the results will aid in future modeling of fish passage at HAHD. Results from these tasks can be used by biologists, engineers, resource managers, and regional decision-makers to inform baseline conditions under current operations and the engineering design of the new FPF at HAHD. This draft report contains initial data and results from the four tasks. Table 8 1, Table 8 2, and Table 8 3, and Figure 8 1, Figure 8 2, and Figure 8 3 depict the CFD modeling findings for the GPR steep slope bypass, HAHD horseshoe tunnel, and laboratory testing. Table 8 4, Table 8 5, and Table 8 6 depict the Sensor Fish findings for the GPR steep slope bypass and HAHD horseshoe tunnel testing. The Mv values observed in the HAHD were significantly lower compared to the laboratory experiments conducted at PNNL. Currently, investigations are underway to understand the reasons for this disparity and to establish an appropriate threshold value for Mv. Survival predictions presented in the tables below should be considered preliminary and should not be used until further analyses and adjustments are completed. The next steps for modeling will include the flow regime, (i.e., density of flow regimes due to water and air mixing ) to continue to improve on the threshold value for Mv.

13 HYDRO ENERGY↗

Quality Control of Silicon Sensor Modules for Particle Detectors

The High-Luminosity Large Hadron Collider (HL-LHC) will produce a higher rate of particle collisions than the current Large Hadron Collider (LHC), requiring important upgrades to the Compact Muon Solenoid (CMS) to handle an increased amount of data. An important upgrade is the Phase-2 Outer Tracker Upgrade, which consists of 13,000 silicon sensor modules made of two parallel silicon sensors and readout electronics. These modules undergo careful quality control checks both during and after module assembly to ensure precise and reliable detector performance. This project focuses on precision testing for quality control of silicon sensor modules at Fermilab. Hands-on work includes visual inspection, current-voltage testing, module testing, and ultraviolet (UV) light exposure of modules showing abnormal current-voltage behavior. The ultraviolet exposure process improves the abnormal sensor readout data by placing the selected sensor side of the module directly under the UV light inside a controlled box. In addition to laboratory testing and ultraviolet experiments, I developed a Python-based data tool that connects to a module database and allows selected testing conditions and module information to be retrieved and displayed efficiently. These different testing procedures, experimental processes, and computational tools support the broader goal of identifying module issues and improving modules that will be used in the CMS Outer Tracker Phase-2 Upgrade.

Siddiqui, Hooriya [DuPage Coll.] (ORCID:0009000151↗

Direct Mercury Detection in Landfill Leachate Using a Novel AuNP-Biopolymer Carbon Screen-Printed Electrode Sensor

A novel Au nanoparticle (AuNP)-biopolymer coated carbon screen-printed electrode (SPE) sensor was developed through the co-electrodeposition of Au and chitosan for mercury (Hg) ion detection. This new sensor showed successful Hg2+ detection in landfill leachate using square wave anodic stripping voltammetry (SWASV) with an optimized condition: a deposition potential of −0.6 V, deposition time of 200 s, amplitude of 25 mV, frequency of 60 Hz, and square wave step voltage of 4 mV. A noticeable peak was observed at +0.58 V associated with the stripping current of the Hg ion. The sensor exhibited a good sensitivity of ~0.09 μA/μg (~0.02 μA/nM) and a linear response over the concentration range of 10 to 100 ppb (50–500 nM). The limit of detection (LOD) was 1.69 ppb, which is significantly lower than the safety limit defined by the United States Environmental Protection Agency (USEPA). The sensor had an excellent selective response to Hg2+ in landfill leachate against other interfering cations (e.g., Zn2+, Pb2+, Cd2+, and Cu2+). Fifteen successive measurements with a stable peak current and a lower relative standard deviation (RSD = 5.1%) were recorded continuously using the AuNP-biopolymer-coated carbon SPE sensor, which showed excellent stability, sensitivity and reproducibility and consistent performance in detecting the Hg2+ ion. It also exhibited a good reliability and performance in measuring heavy metals in landfill leachate.

Hwang, Jae-Hoon (ORCID:0000000220100864)↗

A Hermetic Package Technique for Multi-Functional Fiber Sensors through Pressure Boundary of Energy Systems Based on Glass Sealants

This paper presents a hermitic fiber sensor packaging technique that enables fiber sensors to be embedded in energy systems for performing multi-parameter measurements in high-temperature and strong radiation environments. A high-temperature stable Intrinsic Fabry–Perot interferometer (IFPI) array, inscribed by a femtosecond laser direct writing scheme, is used to measure both temperature and pressure induced strain changes. To address the large disparity in thermo-expansion coefficients (TECs) between silica fibers and metal parts, glass sealants with TEC between silica optical fibers and metals were used to hermetically seal optical fiber sensors inside stainless steel metal tubes. The hermetically sealed package is validated for helium leakages between 1 MPa and 10 MPa using a helium leak detector. An IFPI sensor embedded in glass sealant was used to measure pressure. The paper demonstrates an effective technique to deploy fiber sensors to perform multi-parameter measurements in a wide range of energy systems that utilize high temperatures and strong radiation environments to achieve efficient energy production.

Optics↗

Design and Evaluation of Sensor Housing for Boundary Layer Profiling Using Multirotors

Traditional configurations for mounting Temperature–Humidity (TH) sensors on multirotor Unmanned Aerial Systems (UASs) often suffer from insufficient radiation shielding, exposure to mixed and turbulent air from propellers, and inconsistent aspiration while situated in the wake of the UAS. Descent profiles using traditional methods are unreliable (when compared to an ascent profile) due to the turbulent mixing of air by the UAS while descending into that flow field. Consequently, atmospheric boundary layer profiles that rely on such configurations are bias-prone and unreliable in certain flight patterns (such as descent). This article describes and evaluates a novel sensor housing designed to shield airborne sensors from artificial heat sources and artificial wet-bulbing while pulling air from outside the rotor wash influence. The housing is mounted above the propellers to exploit the rotor-induced pressure deficits that passively induce a high-speed laminar airflow to aspirate the sensor consistently. Our design is modular, accommodates a variety of other sensors, and would be compatible with a wide range of commercially available multirotors. Extensive flight tests conducted at altitudes up to 500 m Above Ground Level (AGL) show that the housing facilitates reliable measurements of the boundary layer phenomena and is invariant in orientation to the ambient wind, even at high vertical/horizontal speeds (up to 5 m/s) for the UAS. A low standard deviation of errors shows a good agreement between the ascent and descent profiles and proves our unique design is reliable for various UAS missions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Printed Potentiometric Nitrate Sensors for Use in Soil

Plant-available nitrogen, often in the form of nitrate, is an essential nutrient for plant growth. However, excessive nitrate in the environment and watershed has harmful impacts on natural ecosystems and consequently human health. A distributed network of nitrate sensors could help to quantify and monitor nitrogen in agriculture and the environment. Here, we have developed fully printed potentiometric nitrate sensors and characterized their sensitivity and selectivity to nitrate. Each sensor comprises an ion-selective electrode and a reference electrode that are functionalized with polymeric membranes. The sensitivity of the printed ion-selective electrodes was characterized by measuring their potential with respect to a commercial silver/silver chloride reference electrode in varying concentrations of nitrate solutions. The sensitivity of the printed reference electrodes to nitrate was minimized with a membrane containing polyvinyl butyral (PVB), sodium chloride, and sodium nitrate. Selectivity studies with sulphate, chloride, phosphate, nitrite, ammonium, calcium, potassium, and magnesium showed that high concentrations of calcium can influence sensor behavior. The printed ion-selective and reference electrodes were combined to form a fully printed sensor with sensitivity of −48.0 ± 3.3 mV/dec between 0.62 and 6200 ppm nitrate in solution and −47 ± 4.1 mV/dec in peat soil.

Baumbauer, Carol L. (ORCID:0000000246747551)↗

Experimental Investigation of Low-Frequency Distributed Acoustic Sensor Responses to Two Parallel Propagating Fractures

Low-frequency distributed acoustic sensing (LF-DAS) is a diagnostic tool for hydraulic fracture propagation with far-field monitoring using fiber optic sensors. LF-DAS senses strain rate variation caused by stress field change due to fracture propagation. Fiber optic sensors are installed in the monitoring wells in the vicinity of a fractured well. From the strain responses, fracture propagation can be evaluated. To understand subsurface conditions with multiple propagating fractures, a laboratory-scale hydraulic fracture experiment was performed simulating the LF-DAS response to fracture propagation with embedded distributed optical fiber strain sensors under these conditions. The experiment was performed using a transparent cube of epoxy with two parallel radial initial flaws centered in the cube. Fluid was injected into the sample to generate fractures along the initial flaws. The experiment used distributed high-definition fiber optic strain sensors with tight spatial resolutions. The sensors were embedded at two different locations on opposite sides of the initial flaws, serving as observation/monitoring locations. We also employed finite element modeling to numerically solve the linear elastic equations of equilibrium continuity and stress–strain relationships. The measured strains from the experiment were compared to simulation results from the finite element model. The experimentally derived strain and strain-rate waterfall plots from this study show the responses to both fractures propagating, while the fracture at the lower position took most of the fluid during the experiment. Interestingly, a fracture first began propagating from the upper flaw of the two flaws, but once the lower fracture was initiated, it grew much faster than the upper fracture. Both fibers were intercepted by the lower fracture, further verifying the strain signature as a fracture is approaching and intersecting an offset fiber.

Chemistry↗

Wide Area and Distributed Hydrogen Sensors

Recent advances in optical sensors show promise for the development of new wide area monitoring and distributed optical network hydrogen detection systems. Optical hydrogen sensing technologies reviewed here are: 1) open path Raman scattering systems, 2) back scattering from chemically treated solid polymer matrix optical fiber sensor cladding; and 3) shlieren and shearing interferometry imaging. Ultrasonic sensors for hydrogen release detection are also reviewed. The development status of these technologies and their demonstrated results in sensor path length, low hydrogen concentration detection ability, and response times are described and compared to the corresponding status of hydrogen spot sensor network technologies.

08 HYDROGEN↗

MELT WIRE SENSORS AVAILABLE TO DETERMINE PEAK TEMPERATURES IN ATR IRRADIATION TESTING

In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, the ATR will support basic and applied nuclear research and development and help address the nation's energy security needs. In support of this new program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance sensors provided in irradiation locations where instrumentation leads cannot be included, such as drop-in capsule and Hydraulic Shuttle Irradiation System (HSIS) or 'rabbit' locations. To meet the need for these locations, the INL has developed melt wire temperature sensors for use in ATR irradiation testing. Differential scanning calorimetry and environmental testing of prototypical sensors was used to develop a library of 28 melt wire materials, capable of detecting peak irradiation temperatures ranging from 85 to 1500°C. This paper will discuss the development work and present test results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vibration welding system with thin film sensor

A vibration welding system includes an anvil, a welding horn, a thin film sensor, and a process controller. The anvil and horn include working surfaces that contact a work piece during the welding process. The sensor measures a control value at the working surface. The measured control value is transmitted to the controller, which controls the system in part using the measured control value. The thin film sensor may include a plurality of thermopiles and thermocouples which collectively measure temperature and heat flux at the working surface. A method includes providing a welder device with a slot adjacent to a working surface of the welder device, inserting the thin film sensor into the slot, and using the sensor to measure a control value at the working surface. A process controller then controls the vibration welding system in part using the measured control value.

42 ENGINEERING↗

Microscale autonomous sensor and communications module

Various technologies pertaining to a microscale autonomous sensor and communications module are described herein. Such a module includes a sensor that generates a sensor signal that is indicative of an environmental parameter. An integrated circuit receives the sensor signal and generates an output signal based at least in part upon the sensor signal. An optical emitter receives the output signal and generates an optical signal as a function of the output signal. An energy storage device is configured to provide power to at least the integrated circuit and the optical emitter, and wherein the module has a relatively small diameter and thickness.

97 MATHEMATICS AND COMPUTING↗

Sensor system for fuel transport vehicle

An exemplary sensor system for a fuel transport vehicle can comprise a fuel marker sensor positioned between a fuel storage chamber of the vehicle and an access valve for the fuel storage chamber of the vehicle. The fuel marker sensor can be configured to measure one or more characteristics of one or more fuel markers present in the fuel adjacent the sensor, such as when the marked fuel is unloaded at a retail station. The one or more characteristics can comprise concentration and/or identity of the one or more fuel markers in the fuel. Based on the measured characteristics of the one or more fuel markers, the sensor system can identify the fuel and/or can determine whether the fuel has been adulterated after the marked fuel was last measured, such as when the marked fuel was loaded into the vehicle.

02 PETROLEUM↗

Non-contact current and voltage sensor having detachable housing incorporating multiple ferrite cylinder portions

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing formed from two portions that mechanically close around the wire and that contain the current and voltage sensors. The current sensor is a ferrite cylinder formed from at least three portions that form the cylinder when the sensor is closed around the wire with a hall effect sensor disposed in a gap between two of the ferrite portions along the circumference to measure current. A capacitive plate or wire is disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensor sentinel computing device

Technologies pertaining to authenticating data output by sensors in an industrial environment are described herein. A sensor sentinel computing device receives time-series data from a sensor by way of a wireline connection. The sensor sentinel computing device generates a validation signal that is a function of the time-series signal. The sensor sentinel computing device then transmits the validation signal to a programmable logic controller in the industrial environment.

97 MATHEMATICS AND COMPUTING↗

Beam imaging sensor and method for using same

The present invention relates generally to the field of sensors for beam imaging and, in particular, to a new and useful beam imaging sensor for use in determining, for example, the power density distribution of a beam including, but not limited to, an electron beam or an ion beam. In one embodiment, the beam imaging sensor of the present invention comprises, among other items, a circumferential slit that is either circular, elliptical or polygonal in nature. In another embodiment, the beam imaging sensor of the present invention comprises, among other things, a discontinuous partially circumferential slit. Also disclosed is a method for using the various beams sensor embodiments of the present invention.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation and 3D-tracking of objects by pointing sensors

A method and system for tracking at least one object using a plurality of pointing sensors and a tracking system are disclosed herein. In a general embodiment, the tracking system is configured to receive a series of observation data relative to the at least one object over a time base for each of the plurality of pointing sensors. The observation data may include sensor position data, pointing vector data and observation error data. The tracking system may further determine a triangulation point using a magnitude of a shortest line connecting a line of sight value from each of the series of observation data from each of the plurality of sensors to the at least one object, and perform correlation processing on the observation data and triangulation point to determine if at least two of the plurality of sensors are tracking the same object. Observation data may also be branched, associated and pruned using new incoming observation data.

47 OTHER INSTRUMENTATION↗

DIRECT SIMULTANEOUS MEASUREMENT OF PARTICULATE MATTER AND AMMONIA STORAGE ON COMBINED SELECTIVE CATALYTIC REDUCTION FILTER SYSTEMS USING RADIO FREQUENCY SENSORS

Tightening global emissions regulations are motivating interest in the development and implementation of Selective Catalytic Reduction + Filtration (SCRF) systems, which are designed to reduce the concentration of tailpipe particulate matter (PM) and NO x emissions. These systems allow designers to combine the NO x reduction capability of an SCR with the filtration capability of a particulate filter on a single unit. Practical implementation of these systems requires reliable measurement and diagnosis of their state – both with respect to trapped particulate matter as well as adsorbed ammonia. Currently, these systems rely on a variety of gas sensors, mounted upstream or downstream of the system, that only provide an indirect inference of the operation state. In this study, a single radio frequency (RF) sensor was used to perform simultaneous measurements of soot loading and ammonia inventory on an SCRF. Several SCRF core samples were tested at varying soot and ash loads in a catalyst reactor bench. Soot levels were measured by monitoring changes in the bulk dielectric properties within the catalyst using the sensor, while ammonia levels were determined by feeding selected regions of the RF spectrum into a pretrained generalized regression neural network model. Results show the RF sensor is able to directly measure the instantaneous ammonia inventory, while simultaneously providing soot loading measurements within 0.5 g/L. These results confirm that simultaneous measurements of both the PM and ammonia loading state of an SCRF are possible using a single RF sensor via analysis of specific features in the full RF spectrum. The results indicate significant potential to remove the control barriers typically associated with the implementation of advanced SCRF systems.

Ragaller, Paul↗

Application of a Triple Bubbler Sensor for Determining the Density, Surface Tension, and Depth in Molten Salts

Electrochemical (i.e. pyroprocessing) technology is being widely studied throughout the world as a potential alternative to aqueous reprocessing of spent nuclear fuel (SNF). Central to this process is the electrorefiner (ER), in which the useful uranium in the SNF is electrochemically transported through a molten salt electrolyte to a cathode for later recovery. As part of this process, uranium, plutonium, and other actinides accumulate in the ER salt over time. Material accountancy and safeguards of these special nuclear material buildups in near real-time is a significant challenge due to the elevated processing temperatures, remote operation within a hotcell, and high radiation fields. Analytical techniques outside of the hotcell can be used to provide the SNM concentrations of salt samples from the ER. However, determining the actual mass of these materials in the ER presents a significant challenge because the density and volume within the vessel is largely unknown. The Idaho National Laboratory (INL) has developed a triple bubbler sensor capable of determining the density, surface tension, and depth of a fluid in near real-time. Previous experiments in aqueous media has shown that the sensor is capable of determining the density, surface tension and depth with accuracies on the order of 0.2%. The goal of this current work is to test the sensor in several molten salt media to calibrate and validate the triple bubbler. Experiments have been performed in LiCl-KCl eutectic salt. Calibration factors were 1.0015 and 1.26 for density and surface tension, respectively. With the above calibration factors applied, the depth of the salt in the test vessel was determined to within 0.4%. These results indicate that the triple bubbler sensor has the potential to accurately (less than 1% uncertainty) determine the density, surface, tension, and depth of the ER salt in near real-time. The triple bubbler sensor designed at INL can significantly enhance the material accountancy, safeguards, and process monitoring of the electrochemical processing of SNF.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗