Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Enhancement of Second-Order Nonlinear-Optical Signals by Optical Stimulation

Second-order nonlinear optical interactions such as sum- and difference-frequency generation are widely used for bioimaging and as selective probes of interfacial environments. However, inefficient nonlinear optical conversion often leads to poor signal-to-noise ratio and long signal acquisition times. We demonstrate the dramatic enhancement of weak second-order nonlinear optical signals via stimulated sum- and difference-frequency generation. We present a conceptual framework to quantitatively describe the interaction and show that the process is highly sensitive to the relative optical phase of the stimulating field. To emphasize the utility of the technique, we demonstrate stimulated enhancement of second harmonic generation (SHG) from bovine collagen-I fibrils. Using a stimulating pulse fluence of only $3\text{ }\text{ }\mathrm{nJ}/{\mathrm{cm}}^{2}$, we obtain an SHG enhancement >${10}^{4}$ relative to the spontaneous signal. The stimulation enhancement is greatest in situations where spontaneous signals are the weakest—such as low laser power, small sample volume, and weak nonlinear susceptibility—emphasizing the potential for this technique to improve signal-to-noise ratios in biological imaging and interfacial spectroscopy.

42 ENGINEERING↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Indirectly Detected DNP-Enhanced 17 O NMR Spectroscopy: Observation of Non-Protonated Near-Surface Oxygen at Naturally Abundant Silica and Silica-Alumina

Recent studies have shown that dynamic nuclear polarization (DNP) can be used to detect 17 O solid-state NMR spectra of naturally abundant samples within a reasonable experimental time. Observations using indirect DNP, which relies on 1 H mediation in transferring electron hyperpolarization to 17 O, are currently limited mostly to hydroxyls. Direct DNP schemes can hyperpolarize non-protonated oxygen near the radicals; however, they generally offer much lower signal enhancements. In this study, we demonstrate the detection of signals from non-protonated 17 O in materials containing silicon. The sensitivity boost that made the experiment possible originates from three sources: indirect DNP excitation of 29 Si via protons, indirect detection of 17 O through 29 Si nuclei using two-dimensional 29 Si{ 17 O} D-HMQC, and Carr-Purcell-Meiboom-Gill refocusing of 29 Si magnetization during acquisition. This 29 Si-detected scheme enabled, for the first time, 2D 17 O– 29 Si heteronuclear correlation spectroscopy in mesoporous silica and silica-alumina surfaces at natural abundance. In contrast to the silanols showing motion-averaged 17 O signals, the framework oxygens exhibit unperturbed powder patterns as unambiguous fingerprints of surface sites. Furthermore, along with hydroxyl oxygens, detection of these moieties will help in gaining more atomistic-scale insights into surface chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Identification of Calcium Aluminate Inclusions in Steels Using Cathodoluminescence Analysis

We propose a method to identify calcium aluminate inclusions in calcium-treated aluminum-killed steels (Ca{sub 12}Al{sub 14}O{sub 33}, CaAl{sub 4}O{sub 7}, CaAl{sub 12}O{sub 19}, and Al{sub 2}O{sub 3}) using cathodoluminescence (CL) analysis. Such inclusions result in nozzle clogging and melting of the stopper rod during continuous casting. We obtain CL images and CL spectra of calcium aluminate inclusions in model samples of calcium-treated aluminum-killed steel. The model samples are prepared by heating mixtures of Fe powder, Al powder, and Ca shot at 1550 °C in an argon atmosphere. On the basis of the CL colors and CL spectra of the calcium aluminate inclusions, we demonstrate that it is possible to distinguish Ca{sub 12}Al{sub 14}O{sub 33}, CaAl{sub 4}O{sub 7}, CaAl{sub 12}O{sub 19}, and Al{sub 2}O{sub 3} inclusions from CaAl{sub 2}O{sub 4} and Ca{sub 3}Al{sub 10}O{sub 18} inclusions, which do not cause nozzle clogging and melting of the stopper rod, by comparing CL images obtained using digital cameras with and without a built-in filter. The acquisition times for the CL images are less than 10 seconds. Thus, the method we present here can be applied for the rapid detection of harmful calcium aluminate inclusions during continuous casting. The CL spectra also provide basic information to specify compositions in agglomerated calcium aluminate inclusions.

36 MATERIALS SCIENCE↗

Fusion of Laboratory and Textual Data for Investigative Bioforensics

Chemical and biological forensic programs focus on the identification of a threat and acquisition of laboratory measurements to determine how a threat agent may have been produced. However, to generate investigative leads, it might also be useful to identify institutions where the same agent has been produced by the same or a very similar process, since the producer of the agent may have learned methods at a university or similar institution. We have developed a Bayesian network framework that fuses hard and soft data sources to assign probability to production practices. It combines the results of laboratory measurements with an automatic text reader to scan scientific literature and rank institutions that had published papers on the agent of interest in order of the probability that the institution has the capability to generate the sample of interest based on laboratory data. We demonstrate the Bayesian network on an example case from microbial forensics, predicting the methods used to produce Bacillus anthracis spores based on mass spectrometric measurements and identifying institutions that have a history of growing Bacillus spores using the same or highly similar methods. We illustrate that the network model can assign a higher posterior probability than expected by random chance to appropriate institutions when trained using only a small set of manually analyzed documents. This is the first example of an automated methodology to integrate experimental and textual data for the purpose of investigative forensics.

Webb-Robertson, Bobbie-Jo M.↗

Geo Thermal Cloud: Cloud Fusion of Big Data and Multi-Physics Models using Machine Learning for Discovery, Exploration, and Development of Hidden Geothermal Resources

The project is motivated by the challenges, risks, and costs associated with geothermal exploration and production. Many processes and parameters impacting geothermal conditions are poorly understood. Diverse datasets are available to help characterize subsurface geothermal conditions (public and proprietary; satellite, airborne surveys, vegetation/water sampling, geological, geophysical, etc.). Yet, it is not clear how to properly leverage these datasets for geothermal exploration due to an incomplete understanding of how physical processes impacting subsurface geothermal conditions are represented in these observations. Recent advancements in machine learning (ML) provide great promise to resolve these issues. The tremendous challenges and risks of geothermal exploration and production bring the demand for novel ML methods and tools that can (1) analyze large field datasets, (2) assimilate model simulations (large inputs and outputs), (3) process sparse datasets, (4) perform transfer learning (between sites with different exploratory levels), (5) extract hidden geothermal signatures in the field and simulation data, (6) label geothermal resources and processes, (7) identify high-value data acquisition targets, and (8) guide geothermal exploration and production by selecting optimal exploration, production, and drilling strategies. Our goals and work under Phases 1 and 2 (as proposed) of this project address all these needs.

15 GEOTHERMAL ENERGY↗

One-minute nano-tomography using hard X-ray full-field transmission microscope

Full field transmission X-ray microscope (TXM) is a powerful technique for non-destructive 3D imaging with nanometer-scale spatial resolution. However, to date, the typical acquisition time with the hard X-ray TXM at a synchrotron facility is > 10 minutes for a 3D nano-tomography data set with sub-50 nm spatial resolution. This is a significant limit on the types of 3D dynamics that can be investigated using this technique. Here, we present a demonstration of one-minute nano-tomography with sub-50 nm spatial resolution. This achievement is made possible with an in-house designed and commissioned TXM instrument at the Full-field X-ray Imaging (FXI) beamline at the National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Laboratory. This capability represents an order of magnitude decrease in the time required for studying sample dynamics with 10s of nm spatial resolution.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low soil phosphorus availability triggers maize growth stage specific rhizosphere processes leading to mineralization of organic P

Phosphorus (P) is one of the essential nutrients for all living organisms. High-quality mineral P fertilizer is a finite resource with only an estimated 80-100 years of reserves remaining globally. Both plants and microbes have developed several mechanisms such as secretion of organic acids, acidification of the rhizosphere, and production of extracellular enzymes to enhance the acquisition of P from soils. Increased activity of phosphatase occurs in response to P deficiency as part of P starvation responses which catalyze the hydrolysis of P o from soil organic matter (SOM) and release inorganic P (P i ). However, the specific interactions between plants and microbial communities in the rhizosphere soil triggered by P deficiency are largely unknown. In a greenhouse study we grew maize plants in low and high P containing soils and examined the role of rhizosphere processes on mineralization of organic P (P o ) in soils with low and high P availability and different P speciation 23 (Po dominated versus P i dominated) and determine its effect on plant growth. Plant biomass was determined and rhizosphere soils, and soil samples from pots with and without plants were collected at key vegetative growth stages (VGS). A variety of biogeochemical parameters (e.g. microbial biomass C and P, potential phosphatase activities, plant biomass P, soil P species etc.) were determined using both conventional (sequential chemical extraction) and advanced (e.g. high resolution mass spectrometry (FTICR-MS) and 3129 P solution NMR) techniques. Here, we used phospholipid fatty acid (PLFA) and DNA based microbial community analysis to track changes in microbial community structure and diversity. Low P availability induced changes in biogeochemical processes and microbial community composition in the rhizosphere soils of plants grown in low P containing soil. At early VGS, the plants in low P soil were visually struggling which correlated with greater rhizosphere potential acid phosphatase activity and a reduction in P o fractions. At late VGS, the plants appeared to recover which correlated with a decrease in Meh (III) extractable P, an increase in microbial biomass C and P and greater total P in the plant biomass (roots, shoots and leaves). In high P containing soil, on the other hand, greater P availability masked these rhizosphere processes. Our results confirmed the degradation of SOM and Po mineralization in rhizosphere soils driven by microbe and plant need for P. P deficiency may have favored the abundance of fungi which utilized easily degradable root exudates for the production of extracellular enzymes responsible for the mineralize of SOM P o . This study highlights the intertwined mechanisms involved, and emphasizes the importance of, P o sources for plant nutrition and survival in marginal soils.

59 BASIC BIOLOGICAL SCIENCES↗

Spectroscopic and computational investigations of organometallic complexation of group 12 transition metals by methanobactins from Methylocystis sp. SB2

Methanotrophic bacteria catalyze the aerobic oxidation of methane to methanol using Cu-containing enzymes, thereby exerting a modulating influence on the global methane cycle. To facilitate the acquisition of Cu ions, some methanotrophic bacteria secrete small modified peptides known as “methanobactins,” which strongly bind Cu and function as an extracellular Cu recruitment relay, analogous to siderophores and Fe. In addition to Cu, methanobactins form complexes with other late transition metals, including the Group 12 transition metals Zn, Cd, and Hg, although the interplay among solution-phase configurations, metal interactions, and the spectroscopic signatures of methanobactin-metal complexes remains ambiguous. In this study, the complexation of Zn, Cd, and Hg by methanobactin from Methylocystis sp. strain SB2 was studied using a combination of absorbance, fluorescence, extended x-ray absorption fine structure (EXAFS) spectroscopy, and time-dependent density functional theory (TD-DFT) calculations. We report changes in sample absorbance and fluorescence spectral dynamics, which occur on a wide range of experimental timescales and characterize a clear stoichiometric complexation dependence. Mercury L3-edge EXAFS and TD-DFT calculations suggest a linear model for Hg--S coordination, and TD-DFT suggests a tetrahedral model for Zn 2+ and Cd 2+ . We observed an enhancement in the fluorescence of methanobactin upon interaction with transition metals and propose a mechanism of complexation-hindered isomerization drawing inspiration from the wild-type Green Fluorescent Protein active site. Collectively, our results represent the first combined computational and experimental spectroscopy study of methanobactins and shed new light on molecular interactions and dynamics that characterize complexes of methanobactins with Group 12 transition metals.

59 BASIC BIOLOGICAL SCIENCES↗

Neurogenesis Deep Learning: Extending deep networks to accommodate new classes

Neural machine learning methods, such as deep neural networks (DNN), have achieved remarkable success in a number of complex data processing tasks. These methods have arguably had their strongest impact on tasks such as image and audio processing – data processing domains in which humans have long held clear advantages over conventional algorithms. In contrast to biological neural systems, which are capable of learning continuously, deep artificial networks have a limited ability for incorporating new information in an already trained network. As a result, methods for continuous learning are potentially highly impactful in enabling the application of deep networks to dynamic data sets. Here, inspired by the process of adult neurogenesis in the hippocampus, we explore the potential for adding new neurons to deep layers of artificial neural networks in order to facilitate their acquisition of novel information while preserving previously trained data representations. Our results on the MNIST handwritten digit dataset and the NIST SD 19 dataset, which includes lower and upper case letters and digits, demonstrate that neurogenesis is well suited for addressing the stability-plasticity dilemma that has long challenged adaptive machine learning algorithms.

59 BASIC BIOLOGICAL SCIENCES↗

The Materials Provenance Store

Abstract We present a database resulting from high throughput experimentation, primarily on metal oxide solid state materials. The central relational database, the Materials Provenance Store (MPS), manages the metadata and experimental provenance from acquisition of raw materials, through synthesis, to a broad range of materials characterization techniques. Given the primary research goal of materials discovery of solar fuels materials, many of the characterization experiments involve electrochemistry, along with optical, structural, and compositional characterizations. The MPS is populated with all information required for executing common data queries, which typically do not involve direct query of raw data. The result is a database file that can be distributed to users so that they can independently execute queries and subsequently download the data of interest. We propose this strategy as an approach to manage the highly heterogeneous and distributed data that arises from materials science experiments, as demonstrated by the management of over 30 million experiments run on over 12 million samples in the present MPS release.

36 MATERIALS SCIENCE↗

Environmental Baseline Survey Report for the Title Transfer of Land Parcel ED-4 at the East Tennessee Technology Park, Oak Ridge, Tennessee

This environmental baseline survey (EBS) report documents the baseline environmental conditions of a land parcel referred to as 'ED-4' (ED-4) at the U. S. Department of Energy's (DOE's) East Tennessee Technology Park (ETTP). DOE is proposing to transfer the title of this land to the Heritage Center, LLC. Parcel ED-4 is a land parcel that consists of two noncontiguous areas comprising a total of approximately 18 acres located east of the ETTP. The western tract of ED-4 encompasses approximately 8.5 acres in the northeastern quadrant of the intersection of Boulevard Road and Highway 58. The eastern tract encompasses an area of approximately 9.5 acres in the northwestern quadrant of the intersection of Blair Road and Highway 58 (the Oak Ridge Turnpike). Aerial photographs and site maps from throughout the history of the ETTP, going back to its initial development in the 1940s as the Oak Ridge Gaseous Diffusion Plant (ORGDP), indicate that this area has been undeveloped woodland with the exception of three support facilities for workers constructing the ORGDP since federal acquisition in 1943. These three support facilities, which were located in the western tract of ED-4, included a recreation hall, the Town Hall Camp Operations Building, and the Property Warehouse. A railroad spur also formerly occupied a portion of Parcel ED-4. These former facilities only occupied approximately 5 percent of the total area of Parcel ED-4. This report provides supporting information for the transfer of this government-owned property at ETTP to a non-federal entity. This EBS is based upon the requirements of Sect. 120(h) of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). In order to support a Clean Parcel Determination (CPD) in accordance with CERCLA Sect. 120(h)(4)(d), groundwater and sediment samples were collected within, and adjacent to, the Parcel ED-4 study area. The potential for DOE to make a CPD for ED-4 is further supported by a No Further Investigation (NFI) determination made on land that adjoins ED-4 to the east (DOE 1997a) and to the south (DOE 1997b).

54 ENVIRONMENTAL SCIENCES↗

Synchronization of high speed framing camera and intense electron-beam accelerator

A new trigger program is proposed to realize the synchronization of high speed framing camera (HSFC) and intense electron-beam accelerator (IEBA). The trigger program which include light signal acquisition radiated from main switch of IEBA and signal processing circuit could provide a trigger signal with rise time of 17 ns and amplitude of about 5 V. First, the light signal was collected by an avalanche photodiode (APD) module, and the delay time between the output voltage of APD and load voltage of IEBA was tested, it was about 35 ns. Subsequently, the output voltage of APD was processed further by the signal processing circuit to obtain the trigger signal. At last, by combining the trigger program with an IEBA, the trigger program operated stably, and a delay time of 30 ns between the trigger signal of HSFC and output voltage of IEBA was obtained. Meanwhile, when surface flashover occurred at the high density polyethylene sample, the delay time between the trigger signal of HSFC and flashover current was up to 150 ns, which satisfied the need of synchronization of HSFC and IEBA. So the experiment results proved that the trigger program could compensate the time (called compensated time) of the trigger signal processing time and the inherent delay time of the HSFC.

43 PARTICLE ACCELERATORS↗

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system]

Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markings that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.

47 OTHER INSTRUMENTATION↗

Upgrades to the Polarized Neutron Reflectometer Asterix at LANSCE

We have upgraded the polarized neutron reflectometer, Asterix, at the Lujan Neutron Scattering Center at Los Alamos for the benefit of the research communities that study magnetic and complex-fluid films, both of which play important roles in support of the DOE’s energy mission. The upgrades to the instrument include: A secondary spectrometer that was integrated with a Huber sample goniometer purchased with other funds just prior to the start of our project. The secondary spectrometer provides a flexible length for the scattered flight path, includes a mechanism to select among 3 alternative polarization analyzers as well as a support for new neutron detectors. Also included is an optic rail for reproducible positioning of components for Spin Echo Scattering Angle Measurement (SESAME). The entire secondary spectrometer is now non-magnetic, as required for neutron Larmor labeling. • A broad-band neutron polarizer for the incident neutron beam based on the V geometry. • A wide-angle neutron polarization analyzer • A 2d position-sensitive neutron detector • Electromagnetic coils (Wollaston prisms) for SESAME plus the associated power supplies, cooling, safety systems and integration into the data acquisition system. The upgrades allowed a nearly effortless transition between configurations required to serve the polarized neutron reflectometry community, users of the 11 T cryomagnet and users of SESAME.

36 MATERIALS SCIENCE↗

Mini Micropulse Lidar measurements in vertical and scanning modes

The Atmospheric Radiation Measurement (ARM) program operates ten Sigma Space (currently Droplet Measurement Technologies/DMT) micropulse lidar systems (MPL-4B-IDS/POL-FS series), which detect the backscattered light in two orthogonal linear polarization channels allowing to distinguish between spherical (e.g. water) and non-spherical (e.g. ice) scattering particles. The ARM MPLs have been providing valuable measurements to the aerosol and cloud research community for well over a decade. DMT’s Mini-Micropulse lidar (MiniMPL) is a compact version of the standard MPL. It reduces the power-aperture product to minimize cost, size, weight, power requirements and has all the electronics integrated with optics in a single box. Although as a result, it has a lower detection range than the MPL, limiting the measurements to the troposphere, its performance is promised to match that of the standard MPL within the troposphere. The MiniMPL weighs 13 kg, and the complete system, consisting of an optical transceiver and a laptop running the data acquisition and post-processing software, fits in a storm case, allowing its transport on domestic or international flights. This can be especially valuable for short field campaigns or Intensive Operational Periods, where time is of the essence when replacing a faulty instrument. In addition, the scanning polarization lidar capability (MiniMPL-SCAN option) could be of great interest for satisfying ARM measurement needs for certain research topics related to clouds and precipitation. To evaluate its full potential in comparison with co-located remote sensing instruments including the ARM MPL-4B-IDS/POL-FS at SGP, a miniMPL was hosted at the ARM Southern Great Plains (SGP) mega-site in 2020 for approximately 3 months. During this time the miniMPL was tested in both vertical sampling and scanning modes.

54 ENVIRONMENTAL SCIENCES↗