Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

Direct CP violation and the ΔI=1/2 rule in K→ππ decay from the standard model

We present a lattice QCD calculation of the Δ I = 1 / 2 , K → π π decay amplitude A 0 and ϵ ' , the measure of direct C P violation in K → π π decay, improving our 2015 calculation [1] of these quantities. Both calculations were performed with physical kinematics on a 32 3 × 64 lattice with an inverse lattice spacing of a - 1 = 1.3784 ( 68 ) GeV . However, the current calculation includes nearly 4 times the statistics and numerous technical improvements allowing us to more reliably isolate the π π ground state and more accurately relate the lattice operators to those defined in the standard model. We find Re ( A 0 ) = 2.99 ( 0.32 ) ( 0.59 ) × 10 - 7 GeV and Im ( A 0 ) = - 6.98 ( 0.62 ) ( 1.44 ) × 10 - 11 GeV , where the errors are statistical and systematic, respectively. The former agrees well with the experimental result Re ( A 0 ) = 3.3201 ( 18 ) × 10 - 7 GeV . These results for A 0 can be combined with our earlier lattice calculation of A 2 [2] to obtain Re ( ϵ ' / ϵ ) = 21.7 ( 2.6 ) ( 6.2 ) ( 5.0 ) × 10 - 4 , where the third error represents omitted isospin breaking effects, and Re ( A 0 ) / Re ( A 2 ) = 19.9 ( 2.3 ) ( 4.4 ) . The first agrees well with the experimental result of Re ( ϵ ' / ϵ ) = 16.6 ( 2.3 ) × 10 - 4 . A comparison of the second with the observed ratio Re ( A 0 ) / Re ( A 2 ) = 22.45 ( 6 ) , demonstrates the standard model origin of this “ Δ I = 1 / 2 rule” enhancement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A minimum information standard for reproducing bench-scale bacterial cell growth and productivity

Reproducing, exchanging, comparing, and building on each other’s work is foundational to technology advances. Advancing biotechnology calls for reliable reuse of engineered organisms. Reliable reuse of engineered organisms requires reproducible growth and productivity. Here, we identify the experimental factors that have the greatest effect on the growth and productivity of our engineered organisms in order to demonstrate reproducibility for biotechnology. Here, we present a draft of a Minimum Information Standard for Engineered Organism Experiments based on this method. We evaluate the effect of 22 factors on Escherichia coli engineered to produce the small molecule lycopene, and 18 factors on E. coli engineered to produce red fluorescent protein. Container geometry and shaking have the greatest effect on product titer and yield. We reproduce our results under two different conditions of reproducibility: conditions of use (different fractional factorial experiments), and time (48 biological replicates performed on 12 different days over four months).

59 BASIC BIOLOGICAL SCIENCES↗

Advanced Packaging Materials and Techniques for High Power TR Module: Standard Flight vs. Advanced Packaging

The higher output power densities required of modern radar architectures, such as the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI) require increasingly dense high power electronics. To enable these higher power densities, while maintaining or even improving hardware reliability, requires advances in integrating advanced thermal packaging technologies into radar transmit/receive (TR) modules. New materials and techniques have been studied and compared to standard technologies.

Deformation, Ecosystem Structure, and Dynamics of ↗

FRACTURE MECHANICAL MEASUREMENTS WITH COMMERCIAL STAINLESS STEELS AT 4 K AND WITH CP-TITANIUM AT 173 K

Using the JETT (J-Evaluation on Tensile Test) technique, measurements have been performed with commercial stainless steels in forged and cast condition for the reason of an assessment for low temperature service down to 4 K. These steels frequently used for industrial applications are designated by German Werkstoff (WNr) 1.4308 and 1.4408 cast stainless steels and a forged material with the number 1.4307. The fracture toughness tests at 4 K with forged material 1.4307 comprised apart from the base metal also the weld zone and additionally the 5% and 8% pre-strained conditions of the base metal. Fracture toughness reduced slightly for cold worked condition gradually as well as for the weld joint. The Reliability of the JETT measurements has been also checked using the ASTM E 1820--99a standard. In addition, to these measurements, commercial pure ASTM grade 2 titanium (WNr 3.7035) has been also examined using the same JETT method for the reason of industrial application and the requirement of minimum fracture toughness of 100 MPasq root(m) was fulfilled at 173 K. Furthermore, test results performed at 7 K of pure titanium plate material (ASTM grade 1) with respect to fracture mechanical JETT method are presented.

36 MATERIALS SCIENCE↗

A high-fidelity Monte Carlo evaluation of CANDU-6 safety parameters

Important safety parameters such as the fuel temperature coefficient (FTC) and the power coefficient of reactivity (PCR) of the CANDU-6 (CANada Deuterium Uranium) reactor have been evaluated by using a modified MCNPX code. For accurate analysis of the parameters, the DBRC (Doppler Broadening Rejection Correction) scheme was implemented in MCNPX in order to account for the thermal motion of the heavy uranium nucleus in the neutron-U scattering reactions. In this work, a standard fuel lattice has been modeled and the fuel is depleted by using the MCNPX and the FTC value is evaluated for several burnup points including the mid-burnup representing a near-equilibrium core. The Doppler effect has been evaluated by using several cross section libraries such as ENDF/B-VI, ENDF/B-VII, JEFF, JENDLE. The PCR value is also evaluated at mid-burnup conditions to characterize safety features of equilibrium CANDU-6 reactor. To improve the reliability of the Monte Carlo calculations, huge number of neutron histories are considered in this work and the standard deviation of the k-inf values is only 0.5{approx}1 pcm. It has been found that the FTC is significantly enhanced by accounting for the Doppler broadening of scattering resonance and the PCR are clearly improved. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development and Use of Engineering Standards for Computational Fluid Dynamics for Complex Aerospace Systems

Computational fluid dynamics (CFD) and other advanced modeling and simulation (M&S) methods are increasingly relied on for predictive performance, reliability and safety of engineering systems. Analysts, designers, decision makers, and project managers, who must depend on simulation, need practical techniques and methods for assessing simulation credibility. The AIAA Guide for Verification and Validation of Computational Fluid Dynamics Simulations (AIAA G-077-1998 (2002)), originally published in 1998, was the first engineering standards document available to the engineering community for verification and validation (V&V) of simulations. Much progress has been made in these areas since 1998. The AIAA Committee on Standards for CFD is currently updating this Guide to incorporate in it the important developments that have taken place in V&V concepts, methods, and practices, particularly with regard to the broader context of predictive capability and uncertainty quantification (UQ) methods and approaches. This paper will provide an overview of the changes and extensions currently underway to update the AIAA Guide. Specifically, a framework for predictive capability will be described for incorporating a wide range of error and uncertainty sources identified during the modeling, verification, and validation processes, with the goal of estimating the total prediction uncertainty of the simulation. The Guide's goal is to provide a foundation for understanding and addressing major issues and concepts in predictive CFD. However, this Guide will not recommend specific approaches in these areas as the field is rapidly evolving. It is hoped that the guidelines provided in this paper, and explained in more detail in the Guide, will aid in the research, development, and use of CFD in engineering decision-making.

Lee, Hyung B.↗

Technology Evaluation of Programmable Communicating Thermostats with Radio Broadcast Data System Communications

Programmable Communicating Thermostats are thermostats that can be programmed by the user to respond to signals indicating a grid-level system emergency or pricing event. The California Energy Commission is considering standards that would include a requirement for Programmable Communicating Thermostats in residential and small commercial applications. The current specification for Programmable Communicating Thermostats requires Radio Data System communications to Programmable Communicating Thermostats. This study tested the signal strength and reliability of Radio Data System signals at 40 customer sites within the Sacramento Municipal Utility District, which is serviced by 17 radio stations that already transmit Radio Data System signals. The study also tested the functionality of a commercially available Programmable Communicating Thermostat for compliance with California Energy Commission design standards. Test results demonstrated that Radio Data System is capable of reliably sending price and emergency signals. This study also provides evidence that existing Programmable Communicating Thermostats, on receiving a Radio Data System pricing or event signal, are capable of automatically increasing set points to a customer-determined or utility-determined level, thus providing air-conditioning demand response within seconds or just a few (less than 5) minutes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reducing Barriers in Space Weather Research and Operations with Next-Generation Simulation Services at the Community Coordinated Modeling Center (CCMC)

Space weather forecasting capabilities are becoming increasingly important to the health of advanced technological infrastructure. The Community Coordinated Modeling Center (CCMC, https://ccmc.gsfc.nasa.gov) serves as a key liaison in the US space weather program between the research and operations communities by providing a wide range of tools and capabilities that help to evaluate, compare, exercise, and archive the results of simulations of a growing list of space weather models. With its unique toolset, CCMC supports space weather research and model development that advances our understanding of space weather phenomena and improves forecasting skill, while also facilitating development of space weather applications and deployment of operational capabilities. Guided by experience from over 20 years of providing simulation services, feedback from its research, operational and educational users world-wide, recommendations from CCMC Advisory Group and Programmatic Review Panel, the CCMC has begun work on the next generation system for its simulation services and model output archives. The new system has been envisioned to employ state-of-the-art technologies and standards to provide a user-oriented experience while improving ease of access, transparency, interoperability with partner systems, and enhancing reliability by incorporating advanced automation for performance monitoring and intelligent failover. In the presentation, we will give an overview of the current CCMC ecosystem and discuss updates to some of the key services of the system, including Runs-on-Request, Instant Runs, and Continuous Runs. We will also describe how a planned expansion and standardization of data archival activities will enhance the role of CCMC as a world-class provider of heliophysics information for the research and analysis of space weather. It is our hope that this evolution of the services can further reduce the barriers and burdens on researchers, forecasters and decision makers who rely on CCMC for their daily research and operations.

Space Weather↗

Designing the Insulation System for Motors in Electrified Aircraft: Optimization, Partial Discharge Issues and Use of Advanced Materials

Designing the insulation system for motors to be used in electrical aircraft requires efforts for maximizing specific power, but, in parallel, particular attention to achieve high reliability. As a major harm for organic insulation systems is partial discharges, design must be able to infer their likelihood during any operation stage and handle their potential inception. This paper proposes a new approach to carry out optimized or conservative insulation system designs which can provide the specified life at the chosen failure probability as well as look at the option of possibly reducing the risk of partial discharges to zero, at any altitude. Examples of designing turn, phase to ground and phase-to-phase insulation systems are reported, with cases where the design can be optimized and other cases where the optimized design does not pass IEC testing standard. Therefore, the limits for design feasibility as a function of the required level of safety and reliability are discussed, showing that the presence of partial discharges cannot be always avoided even through conservative design criteria. Therefore, the use of advanced, corona-resistant materials must be considered, in order to reach a higher, sometimes redundant, level of reliability.

Ramin, Robin (ORCID:0000000211455006)↗

HUMAN FACTORS AND BEHAVIORAL PERFORMANCE EXPLORATION MEASURES: ASSESSING ASTRONAUT RISK

INTRODUCTION: The Human Factors and Behavioral Performance Exploration Measures (HFBP-EM) suite is a set of standardized measures to assess behavioral health and performance risk related to future exploration class missions, and to support reduction of the Human Research Program’s (HRP) Behavioral Medicine (BMed), Team, Sleep, and Human Systems Integration Architecture (HSIA) risks. This presentation will provide an overview of the HFBP-EM program, describe its implementation across spaceflight analogs and the international space station (ISS), and discuss its applicability to audience members. TOPIC: HFBP-EM is a research program designed to develop a standard set of measures that can be used in space and space-analog research to characterize BMed, Team, Sleep, and HSIA risks. It is an ongoing research project that is used examine the validity and reliability of HFBP measures, as well as their shorter forms. It also serves as a test bed for HFBP measures being considered for the spaceflight standard measures. The suite of measures is used to test the efficacy of countermeasures. To date, HFBP-EM has been collected in Human Exploration Research Analogs campaigns 4 and 5, and the SIRIUS 19 mission in the Russian Ground Based Experiment Complex. A subset of the HFBP-EM suite was collected during spaceflight as part of HRP’s Standard Measures in Spaceflight Project. Data was collected from a total of 55 multinational astronaut and astronaut-like crewmembers (mean age: 39.5, SD = 7.6; 31% female; 91% with advanced degrees). Three broad categories of HFBP-EM measures and their relevance to HRP risks will be discussed: 1) surveys that assess team functioning (Teams risk) as well as mood and affect (Bmed risk), 2) performance-based tasks of cognitive functioning and operationally relevant performance (Bmed risk), and 3) physiological biomarkers of sleep (sleep risk) and heart rate (Bmed risk). We will provide an overview of the background of the HFBP-EM program, what the suite currently includes, and next steps in its future development. We will also discuss the application to aerospace practitioners and researchers. APPLICATION: Astronaut teams selected for future space exploration missions will face several challenges that pose significant yet still unknown risks to the behavioral health and performance of astronauts. The HFBP-EM suite provides a comprehensive assessment of behavioral health and performance in space analog and spaceflight settings. This suite can be applied to both operational and research settings to advance risk reduction research for long duration space exploration missions.

S T Bell↗

The Principle of Maximum Conformality Correctly Resolves the Renormalization-Scheme-Dependence Problem

In this paper, we clarify a serious misinterpretation and consequent misuse of the Principle of Maximum Conformality (PMC), which also can serve as a mini-review of PMC. In a recently published article, P. M. Stevenson has claimed that “the PMC is ineffective and does nothing to resolve the renormalization-scheme-dependence problem”, concluding incorrectly that the success of PMC predictions is due to the PMC being a “laborious, ad hoc, and back-door” version of the Principle of Minimal Sensitivity (PMS). We show that such conclusions are incorrect, deriving from a misinterpretation of the PMC and an overestimation of the applicability of the PMS. The purpose of the PMC is to achieve precise fixed-order pQCD predictions, free from conventional renormalization schemes and scale ambiguities. We demonstrate that the PMC predictions satisfy all the self-consistency conditions of the renormalization group and standard renormalization-group invariance; the PMC predictions are thus independent of any initial choice of renormalization scheme and scale. The scheme independence of the PMC is also ensured by commensurate scale relations, which relate different observables to each other. Moreover, in the Abelian limit, the PMC dovetails into the well-known Gell-Mann–Low framework, a method universally revered for its precision in QED calculations. Due to the elimination of factorially divergent renormalon terms, the PMC series not only attains a convergence behavior far superior to that of its conventional counterparts but also deftly curtails any residual scale dependence caused by the unknown higher-order terms. This refined convergence, coupled with its robust suppression of residual uncertainties, furnishes a sound and reliable foundation for estimating the contributions from unknown higher-order terms. Anchored in the bedrock of standard renormalization-group invariance, the PMC simultaneously eradicates the factorial divergences and eliminates superfluous systematic errors, which inversely provides a good foundation for achieving high-precision pQCD predictions. Consequently, owing to its rigorous theoretical underpinnings, the PMC is eminently applicable to virtually all high-energy hadronic processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Challenges and opportunities for alternative fuels in the maritime sector

Amidst a period of historic transformation, the marine shipping sector faces uncertainty regarding its ability to reliably fuel while remaining compliant with new international environmental regulations and targets. Increasingly stringent environmental standards, and heightened regulatory focus on maritime decarbonization are driving infrastructural and technical development for alternative fuels and mixtures, engine concepts, and operating practices. However, the transition to alternative fueling is highly complex and requires both a global outlook that spans diverse stakeholder demographics and coordination with multiple actors across the value chain. To aid stakeholders involved in decision making and research related to the transition, a scoping study was conducted with the goal of outlining the barriers, uncertainties, and possibilities in the short and long term for the transition. Synthesis of these results provides strategic decision support, technical direction, and a set of R&D priorities for maritime stakeholders and the scientific community.

09 BIOMASS FUELS↗

Routine {sup 18}F{sup -} production with 180 {mu}A to 200 {mu}A target beam current on a GE PETtrace 800 cyclotron

Through upgrades and enhancements, which are now standard on current PETtrace 800 cyclotrons, a GE PETtrace cyclotron installed in 2002 has demonstrated reliable routine [{sup 18}F]FDG production at total target beam currents of 180 {mu}A without detriment to saturation and [{sup 18}F]FDG yields. Routine production at 200 {mu}A has been achieved and its evaluation is continuing. Self-shielded target using W/Cu alloy for the target body afforded a reduction in dose rate from the Havar foils by a factor of {approx} 8-10, reducing dose from the targets and need for removing targets during maintenance. The main activation product in the shield is {sup 187}W (T1/2 24 h). The {sup 60}Co ((T1/2 5.3 y) activation is about 250 times less at 24 h post EOB and is not considered a major issue despite its long half-life.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Modelling and experimental study of temperature profiles in cw laser diode bars

Three-dimensional simulation is used to theoretically assess temperature profiles in proposed 10-mm-wide cw laser diode bars packaged in a standard heat spreader of the C – S mount type with the aim of raising their reliable cw output power. We obtain calculated temperature differences across the emitting aperture and along the cavity. Using experimental laser bar samples with up to 60 W of cw output power, the emission spectra of individual clusters are measured at different pump currents. We compare and discuss the simulation results and experimental data. The bibliography includes 9 references. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generalized Kramers-Kronig transform for Casimir effect computations

Recent advances in experimental techniques now permit measurement of the Casimir force with unprecedented precision. To achieve a comparable precision in the theoretical prediction of the force, it is necessary to accurately determine the electric permittivity of the materials constituting the plates along the imaginary frequency axis. The latter quantity is not directly accessible to experiments, but it can be determined via dispersion relations from experimental optical data. In the experimentally important case of conductors, however, a serious drawback of the standard dispersion relations commonly used for this purpose is their strong dependence on the chosen low-frequency extrapolation of the experimental optical data, which introduces a significant and not easily controllable uncertainty in the result. In this paper we show that a simple modification of the standard dispersion relations, involving suitable analytic window functions, resolves this difficulty, making it possible to reliably determine the electric permittivity at imaginary frequencies using solely experimental optical data in the frequency interval where they are available, without any need for uncontrolled data extrapolations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during a NG shortage offer one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73- bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dis- patch is proposed to allow representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

duel-fuel generator performance↗

A review of lunar chronology revealing a preponderance of 4.34-4.37 Ga ages

In this study, data obtained from Sm-Nd and Rb-Sr isotopic measurements of lunar highlands’ samples are renormalized to common standard values and then used to define ages with a common isochron regression algorithm. The reliability of these ages is evaluated using five criteria that include whether: (1) the ages are defined by multiple isotopic systems, (2) the data demonstrate limited scatter outside uncertainty, (3) initial isotopic compositions are consistent with the petrogenesis of the samples, (4) the ages are defined by an isotopic system that is resistant to disturbance by impact metamorphism, and (5) the rare-earth element abundances determined by isotope dilution of bulk of mineral fractions match those measured by in situ analyses. From this analysis, it is apparent that the oldest highlands’ rock ages are some of the least reliable, and that there is little support for crustal ages older than ~4.40 Ga. A model age for ur-KREEP formation calculated using the most reliable Mg-suite Sm-Nd isotopic systematics, in conjunction with Sm-Nd analyses of KREEP basalts, is 4389 ± 45 Ma. This age is a good match to the Lu-Hf model age of 4353 ± 37 Ma determined using a subset of this sample suite, the average model age of 4353 ± 25 Ma determined on mare basalts with the 146 Sm- 142 Nd isotopic system, with a peak in Pb-Pb ages observed in lunar zircons of ~4340 ± 20 Ma, and the oldest terrestrial zircon age of 4374 ± 6 Ma. The preponderance of ages between 4.34 and 4.37 Ga reflect either primordial solidification of a lunar magma ocean or a widespread secondary magmatic event on the lunar nearside. The first scenario is not consistent with the oldest ages reported for lunar zircons, whereas the second scenario does not account for concordance between ages of crustal rocks and mantle reservoirs.

79 ASTRONOMY AND ASTROPHYSICS↗