Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Correction of Fluorescent Images of Biological Tissues for the Effects of Light Absorption and Scattering

A method for correcting the influence of light attenuation processes in biological tissues on their fluorescent images is proposed. The transfer function that takes into account the radiation losses in the medium at the wavelengths of excitation and emission of fluorescence is calculated analytically, depending on the transport scattering index and the hemoglobin tissue index. The latter is determined on the basis of a color image of the tissue in reflected visible light. Verification of the developed method was carried out on the basis of computer simulation of fluorescent images of biological tissue by the Monte Carlo method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Phase Transitions and Continuous Observation of Spinor Dynamics in an Antiferromagnetic Condensate

Condensates of spin-1 sodium display rich spin dynamics due to the antiferromagnetic nature of the interactions in this system. We use Faraday rotation spectroscopy to make a continuous and minimally destructive measurement of the dynamics over multiple spin oscillations on a single evolving condensate. This method provides a sharp signature to locate a magnetically tuned separatrix in phase space which depends on the net magnetization. We also observe a phase transition from a two- to a three-component condensate at a low but finite temperature using a Stern-Gerlach imaging technique. This transition should be preserved as a zero-temperature quantum phase transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for measuring the nonlinear refractive index from the contrast of an amplitude object image in the optical scheme with phase Zernike filters based on electronic Kerr nonlinearity

We propose a method for determining the nonlinear refractive index from the image contrast of amplitude objects in the phase-contrast scheme with a sample acting as a phase Zernike filter based on the electronic Kerr nonlinearity. This method implies the measurement of the calibration dependence of the contrast of an amplitude object image on the laser pulse energy for a test sample with a known nonlinearity and makes it possible to find the nonlinear refractive index of samples under study using a single laser pulse. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopy of Ba andBa+deposits in solid xenon for barium tagging in nEXO

Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence, and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba + deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of fewer than or equal to 10 4 Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reliability-guided digital image correlation for image deformation measurement

A universally applicable reliability-guided digital image correlation (DIC) method is proposed for reliable image deformation measurement. The zero-mean normalized cross correlation (ZNCC) coefficient is used to identify the reliability of the point computed. The correlation calculation begins with a seed point and is then guided by the ZNCC coefficient. That means the neighbors of the point with the highest ZNCC coefficient in a queue for computed points will be processed first. Thus the calculation path is always along the most reliable direction, and possible error propagation of the conventional DIC method can be avoided. The proposed novel DIC method is universally applicable to the images with shadows, discontinuous areas, and deformation discontinuity. Two image pairs were used to evaluate the performance of the proposed technique, and the successful results clearly demonstrate its robustness and effectiveness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using phase information to enhance speckle noise reduction in the ultrasonic NDE of coarse grain materials

Materials with a coarse grain structure are becoming increasingly prevalent in industry due to their resilience to stress and corrosion. These materials are difficult to inspect with ultrasound because reflections from the grains lead to high noise levels which hinder the echoes of interest. Spatially Averaged Sub-Aperture Correlation Imaging (SASACI) is an advanced array beamforming technique that uses the cross-correlation between images from array sub-apertures to generate an image weighting matrix, in order to reduce noise levels. This paper presents a method inspired by SASACI to further improve imaging using phase information to refine focusing and reduce noise. A-scans from adjacent array elements are cross-correlated using both signal amplitude and phase to refine delay laws and minimize phase aberration. The phase-based and amplitude-based corrected images are used as inputs to a two-dimensional cross-correlation algorithm that will output a weighting matrix that can be applied to any conventional image. This approach was validated experimentally using a 5MHz array a coarse grained Inconel 625 step wedge, and compared to the Total Focusing Method (TFM). Initial results have seen SNR improvements of over 20dB compared to TFM, and a resolution that is much higher.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Color Megapixel QWIP focal plane arrays for remote sensing

In this paper, we will discuss the performance in terms of quantum efficiency, NEAT, uniformity, operability, and modulation transfer functions of the 1024x1024 pixel arrays and the progress of dualband QWIP focal plane array development work.

infixed imaging↗

One-shot omnidirectional pressure integration through matrix inversion

In this work, we present a method to perform 2D and 3D omnidirectional pressure integration from velocity measurements with a single-iteration matrix inversion approach. This work builds upon our previous work, where the rotating parallel ray approach was extended to the limit of infinite rays by taking continuous projection integrals of the ray paths and recasting the problem as an iterative matrix inversion problem. This iterative matrix equation is now 'fast-forwarded' to the 'infinity' iteration, leading to a different matrix equation that can be solved in a single step, thereby presenting the same computational complexity as the Poisson equation. We observe computational speedups of ~10 6 when compared to brute-force omnidirectional integration methods, enabling the treatment of grids of ~10 9 points and potentially even larger in a desktop setup at the time of publication. Further examination of the boundary conditions of our one-shot method shows that omnidirectional pressure integration implements a boundary condition where the boundary points are treated as interior points to the extent that information is available. Finally, we show how the method can be extended from the regular grids typical of particle image velocimetry to the unstructured meshes characteristic of particle tracking velocimetry data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metastable states and macroscopic quantum tunneling in a cold atom josephson ring

We study macroscopic properties of a system of weakly interacting neutral bosons confined in a ring-shaped potential with a Josephson junction. We derive an effective low energy action for this system and evaluate its properties. In particular we find that the system possesses a set of metastable current-carrying states and evaluate the rates of transitions between these states due to macroscopic quantum tunneling. Finally we discuss signatures of different metastable states in the time-of-flight images and argue that the effect is observable within currently available experimental technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noninterferometric phase-contrast images obtained with incoherent x-ray sources

We report on what are believed to be the first full-scale images obtained with the coded aperture concept, which uses conventional x-ray sources without the need to collimate/aperture their output. We discuss the differences in the underpinning physical principles with respect to other methods, and explain why these might lead to a more efficient use of the source. In particular, we discuss how the evaluation of the first imaging system provided promising indications on the method's potential to detect details invisible to conventional absorption methods, use an increased average x-ray energy, and reduce exposure times--all important aspects with regards to real-world implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron image contrast analysis of mosaicity in rutile nanocrystals using direct electron detection

Direct electron detection provides high detective quantum efficiency, significantly improved point spread function and fast read-out which have revolutionized the field of cryogenic electron microscopy. However, these benefits for high-resolution electron microscopy (HREM) are much less exploited, especially for in situ study where major impacts on crystallographic structural studies could be made. By using direct detection in electron counting mode, rutile nanocrystals have been imaged at high temperature inside an environmental transmission electron microscope. The improvements in image contrast are quantified by comparison with a charge-coupled device (CCD) camera and by image matching with simulations using an automated approach based on template matching. Together, these approaches enable a direct measurement of 3D shape and mosaicity (~1°) of a vacuum-reduced TiO 2 nanocrystal about 50 nm in size. Thus, this work demonstrates the possibility of quantitative HREM image analysis based on direct electron detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Noise-Resilient and Reduced Depth Approximate Adders for NISQ Quantum Computing

The "Noisy intermediate-scale quantum" NISQ machine era primarily focuses on mitigating noise, controlling errors, and executing high-fidelity operations, hence requiring shallow circuit depth and noise robustness. Approximate computing is a novel computing paradigm that produces imprecise results by relaxing the need for fully precise output for error-tolerant applications including multimedia, data mining, and image processing. We investigate how approximate computing can improve the noise resilience of quantum adder circuits in NISQ quantum computing. We propose five designs of approximate quantum adders to reduce depth while making them noise-resilient, in which three designs are with carryout, while two are without carryout. We have used novel design approaches that include approximating the Sum only from the inputs (pass-through designs) and having zero depth, as they need no quantum gates. The second design style uses a single CNOT gate to approximate the SUM with a constant depth of O(1). We performed our experimentation on IBM Qiskit on noise models including thermal, depolarizing, amplitude damping, phase damping, and bitflip: (i) Compared to exact quantum ripple carry adder without carryout the proposed approximate adders without carryout have improved fidelity ranging from 8.34% to 219.22%, and (ii) Compared to exact quantum ripple carry adder with carryout the proposed approximate adders with carryout have improved fidelity ranging from 8.23% to 371%. Further, the proposed approximate quantum adders are evaluated in terms of various error metrics.

Gaur, Bhaskar↗

Hot-Carrier-Mediated Photon Upconversion in Metal-Decorated Quantum Wells

Manipulating the frequency of electromagnetic waves forms the core of many modern technologies, ranging from imaging and spectroscopy to radio and optical communication. The process of converting photons from higher to lower energy is easily accomplished and technologically widespread. However, upconversion, which is the process of converting lower-energy photons into higher-energy photons, is still a growing field of study with nascent applications and burgeoning interest. Here, we experimentally demonstrate a new photon upconversion technique mediated by hot carriers in plasmonic nanostructures. Hot holes and hot electrons generated via plasmon decay in illuminated metal nanoparticles are injected into an adjacent semiconductor quantum well where they radiatively recombine to emit higher-energy photons. Using GaN/InGaN quantum wells decorated with gold and silver nanoparticles, we show photon upconversion from 2.4 to 2.8 eV. The process scales linearly with illumination power and enables both geometry- and polarization-based tunability. The conversion of plasmonic losses into upconverted optical emission has the potential to impact bioimaging, on-chip wavelength conversion, and high-efficiency photovoltaics.

14 SOLAR ENERGY↗

On focusing of laser radiation with an axicon

The influence of axially symmetric perturbations of the intensity and phase of the laser beam on its focusing by means of an axicon is considered. It is shown that such perturbations give rise to variations in the radiation energy density on the axicon axis with two periods, {Lambda}/{gamma} and {Lambda}{sup 2}/{lambda}, where {lambda} is the period of perturbation of the laser beam intensity, and {gamma} is the angle of convergence of the focused beam. (imaging)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HIGH-CONTRAST IMAGING VIA MODAL CONVERGENCE OF DEFORMABLE MIRROR

For extremely high contrast imaging, such as direct observation of faint stellar companions, an adaptive optics system is required to produce low-halo and low-speckle regions in the focal plane. A method for deformable mirror control is proposed to achieve this goal. The method relies on a modal convergence of the deformable mirror driven by a focal-plane metric. The modal sets are derived from the Walsh functions. The Walsh-function modes serve two purposes: the expansion of the actuator displacements and the expansion of the phase functions. Taking advantage of the unique properties of the modal functions, a universal control algorithm is devised for the realization of high-contrast focal planes with and without the help of conventional coronagraphy. Numerical modeling is conducted to simulate complete imaging systems under various scenarios. It is shown that the proposed method reliably produces high-contrast focal planes using either a segmented or a membrane mirror. In the presence of random aberration the method is shown to be able to maintain high-contrast focal planes. Requiring neither retrieval of electric fields nor detailed knowledge of the deformable mirrors, this technique may allow high-contrast imaging in real time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Characterization of a High-Energy Neutron Time-of-Flight Imaging System

We present that Los Alamos National Laboratory has developed a prototype of a high-energy neutron time-of-flight imaging system for the non-destructive evaluation of dense, massive, and/or high atomic number objects. High-energy neutrons provide the penetrating power, and thus the high dynamic range necessary to image internal features and defects of such objects. The addition of the time gating capability allows for scatter rejection when paired with a pulsed monoenergetic beam, or neutron energy selection when paired with a pulsed broad-spectrum neutron source. The Time Gating to Reject Scatter and Select Energy (TiGReSSE) system was tested at the Los Alamos Neutron Science Center’s (LANSCE) Weapons Nuclear Research (WNR) facility, a spallation neutron source, to provide proof of concept measurements and to characterize the instrument response. This paper will show results of several objects imaged during this run cycle. In addition, results from system performance metrics such as the Modulation Transfer Function and the Detective Quantum Efficiency measured as a function of neutron energy, characterize the current system performance and inform the next generation of neutron imaging instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Technical Report for "Applied Mathematics Research: Simulation Based Optimization and Application to Electromagnetic Inverse Problems"

The focus of research was: Developing adaptive mesh for the solution of Maxwell's equations; Developing a parallel framework for time dependent inverse Maxwell's equations; Developing multilevel methods for optimization problems with inequality constraints; A new inversion code for inverse Maxwell's equations in the 0th frequency (DC resistivity); A new inversion code for inverse Maxwell's equations in low frequency regime. Although the research concentrated on electromagnetic forward and in- verse problems the results of the research was applied to the problem of image registration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗