Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. V. LiNi 0.4 Co 0.3 0.3 O 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiNi 0.4 Co 0.3 Mn 0.3 O 2 powder obtained from TODA America. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiN i0.4 Co 0.2 Mn 0.3 O 1.6 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VI. LiNi 0.4 Co 0.2 Mn 0.4 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.4 Co 0.2 Mn 0.4 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.5 Co 0.2 Mn 0.5 O 1.9 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VII. LiNi 0.33 Co 0.33 Mn 0.33 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.33 Co 0.33 Mn 0.33 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.4 Co 0.1 Mn 0.7 O 2.0 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VIII. Li 1.2 Ni 0.15 Co 0.1 Mn 0.55 O 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated Li 1.2 Ni 0.15 Co 0.1 Mn 0.55 O 2 powder obtained from TODA America. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.83 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of Li 1.2 Ni 0.4 Co 0.2 Mn 0.9 O 2.8 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. IX. LiCoO 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiCoO 2 powder obtained from BTR New Energy Materials, Inc. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Co 2p, O 1s, C 1s, Co 3s, Co 3p, and Li 1s are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor tin contamination. Making use of the O 1s, Co 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiCo 0.9 O 1.7 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. X. Li 4 Ti 5 O 12

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated Li 4 Ti 5 O 12 powders obtained from Ishihara Sangyo Kaisha, Ltd. and Samsung Fine Chemicals Company, Ltd. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with O 1s, Ti 2p, C 1s, Ti 3s, Li 1s, and Ti 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor potassium signal. Making use of the O 1s, Li 1s, and Ti 3p lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surfaces from Ishihara Sangyo Kaisha, Ltd. and Samsung Fine Chemicals Company, Ltd. of Li 4 Ti 4.7 O 14.1 and Li 4 Ti 4.3 O 13.2 , respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray photoelectron spectroscopy data from lightly Pd doped TiO 2 anatase nanoparticles

Here, two sets of XPS spectra from ≈13 nm slightly Pd-doped anatase TiO 2 particles are reported. Anatase is the most stable form of TiO 2 for small particles, and these spectra are the first spectra from nano-sized anatase to appear in Surface Science Spectra. The high resolution Ti 2p spectrum has an extended range showing important loss features not appearing in most of the earlier data records. The O 1s spectrum also has loss features often ignored, and in this case, the loss features are overlapped by some of the Ti 2s peak features that complicate quantitative analysis. The spectra reported here were used as example spectra in a guide to backgrounds in XPS, and the availability of these spectra in digital form allows LRH-analysts to compare their background selections and analysis approach to those discussed in the guide.

36 MATERIALS SCIENCE↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data

Purpose: Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Methods: Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Results: Distributions of the parameter data were shown to be robust and derive from a student’s t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. Conclusions: IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist’s acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.

60 APPLIED LIFE SCIENCES↗

SU-D-206-04: Iterative CBCT Scatter Shading Correction Without Prior Information

Purpose: To estimate and remove the scatter contamination in the acquired projection of cone-beam CT (CBCT), to suppress the shading artifacts and improve the image quality without prior information. Methods: The uncorrected CBCT images containing shading artifacts are reconstructed by applying the standard FDK algorithm on CBCT raw projections. The uncorrected image is then segmented to generate an initial template image. To estimate scatter signal, the differences are calculated by subtracting the simulated projections of the template image from the raw projections. Since scatter signals are dominantly continuous and low-frequency in the projection domain, they are estimated by low-pass filtering the difference signals and subtracted from the raw CBCT projections to achieve the scatter correction. Finally, the corrected CBCT image is reconstructed from the corrected projection data. Since an accurate template image is not readily segmented from the uncorrected CBCT image, the proposed scheme is iterated until the produced template is not altered. Results: The proposed scheme is evaluated on the Catphan©600 phantom data and CBCT images acquired from a pelvis patient. The result shows that shading artifacts have been effectively suppressed by the proposed method. Using multi-detector CT (MDCT) images as reference, quantitative analysis is operated to measure the quality of corrected images. Compared to images without correction, the method proposed reduces the overall CT number error from over 200 HU to be less than 50 HU and can increase the spatial uniformity. Conclusion: An iterative strategy without relying on the prior information is proposed in this work to remove the shading artifacts due to scatter contamination in the projection domain. The method is evaluated in phantom and patient studies and the result shows that the image quality is remarkably improved. The proposed method is efficient and practical to address the poor image quality issue of CBCT images. This work is supported by the Zhejiang Provincial Natural Science Foundation of China (Grant No. LR16F010001), National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917).

60 APPLIED LIFE SCIENCES↗

SU-F-T-355: Evaluation of Knowledge-Based Planning Model for the Cervical Cancer Radiotherapy

Purpose: The Varian RapidPlan™ is a commercial knowledge-based optimization process which uses a set of clinically used treatment plans to train a model that can predict individualized dose-volume objectives. The purpose of this study is to evaluate the performance of RapidPlan to generate intensity modulated radiation therapy (IMRT) plans for cervical cancer. Methods: Totally 70 IMRT plans for cervical cancer with varying clinical and physiological indications were enrolled in this study. These patients were all previously treated in our institution. There were two prescription levels usually used in our institution: 45Gy/25 fractions and 50.4Gy/28 fractions. 50 of these plans were selected to train the RapidPlan model for predicting dose-volume constraints. After model training, this model was validated with 10 plans from training pool(internal validation) and additional other 20 new plans(external validation). All plans used for the validation were re-optimized with the original beam configuration and the generated priorities from RapidPlan were manually adjusted to ensure that re-optimized DVH located in the range of the model prediction. DVH quantitative analysis was performed to compare the RapidPlan generated and the original manual optimized plans. Results: For all the validation cases, RapidPlan based plans (RapidPlan) showed similar or superior results compared to the manual optimized ones. RapidPlan increased the result of D98% and homogeneity in both two validations. For organs at risk, the RapidPlan decreased mean doses of bladder by 1.25Gy/1.13Gy (internal/external validation) on average, with p=0.12/p<0.01. The mean dose of rectum and bowel were also decreased by an average of 2.64Gy/0.83Gy and 0.66Gy/1.05Gy,with p<0.01/ p<0.01and p=0.04/<0.01 for the internal/external validation, respectively. Conclusion: The RapidPlan model based cervical cancer plans shows ability to systematically improve the IMRT plan quality. It suggests that RapidPlan has great potential to make the treatment planning process more efficient.

60 APPLIED LIFE SCIENCES↗

SU-F-T-395: Evaluation of Best Dosimetry Achievable with VMAT and IMRT Treatment Techniques Targeting Borderline Resectable Pancreatic Cancer

Purpose: To determine from retrospective study the most appropriate technique for targeting small borderline operable pancreatic cancer surrounding blood vessels by evaluating the dosimetry and normal tissue sparing achievable using Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT). Methods: Treatment plans from ten patients who have undergone treatment with a prescribed dose of 4950 cGy, at 275 cGy per fraction, were analyzed. All plans were replanned using Eclipse TPS (Varian Medical Systems, Palo Alto, CA) with complementary VMAT or IMRT techniques to obtain paired data sets for comparison. The coverage to at least 95% of the planned target volume (PTV) was normalized to receive 100% of the prescription dose. The normal tissue constraints followed the quantitative analysis of normal tissue effects in the clinic (QUANTEC) guidelines and the organs at risks (OARs) were liver, kidneys, spinal cord and bowel. The plan evaluation was based on conformity index (CI), homogeneity index (HI), uniformity index (UI), DVH parameters, and student’s-t statistics (2 tails). Results: The VMAT technique delivered less maximum dose to the right kidney, left kidney, total kidney, liver, spinal cord, and bowel by 9.3%, 5.9%, 6.7%, 3.9%, 15.1%, 3.9%, and 4.3%, respectively. The averaged V15 for the total kidney was 10.21% for IMRT and 7.29% for VMAT. The averaged V20 for the bowel was 19.89% for IMRT and 14.06% for VMAT. On average, the CI for IMRT was 1.20 and 1.16 for VMAT (p = 0.20). The HI was 0.08 for both techniques (p = 0.91) and UI was 1.05 and 1.06 for IMRT and VMAT respectively (p = 0.59). Conclusion: Both techniques achieve adequate PTV coverage. Although VMAT techniques show better normal tissue sparing from excessive dose, no significant differences were observed. Slight discrepancies may rise from different versions of calculation algorithms.

60 APPLIED LIFE SCIENCES↗

SU-F-T-521: Flattening-Filter-Free Beam Parameters Comparison From Different Linac Machine Types

Purpose: Novel linac machines, TrueBeam (TB) and Elekta Versa have updated head designing and software control system, include flattening-filter-free (FFF) photon and electron beams. Later on FFF beams were also introduced on C-Series machines. In this work FFF beams for same energy 6MV but from different machine versions were studied with reference to beam data parameters. Methods: The 6MV-FFF percent depth doses, profile symmetry and flatness, dose rate tables, and multi-leaf collimator (MLC) transmission factors were measured during commissioning process of both C-series and Truebeam machines. The scanning and dosimetric data for 6MV-FFF beam from Truebeam and C-Series linacs was compared. A correlation of 6MV-FFF beam from Elekta Versa with that of Varian linacs was also found. Results: The scanning files were plotted for both qualitative and quantitative analysis. The dosimetric leaf gap (DLG) for C-Series 6MV-FFF beam is 1.1 mm. Published values for Truebeam dosimetric leaf gap is 1.16 mm. 6MV MLC transmission factor varies between 1.3 % and 1.4 % in two separate measurements and measured DLG values vary between 1.32 mm and 1.33 mm on C-Series machine. MLC transmission factor from C-Series machine varies between 1.5 % and 1.6 %. Some of the measured data values from C-Series FFF beam are compared with Truebeam representative data. 6MV-FFF beam parameter values like dmax, OP factors, beam symmetry and flatness and additional parameters for C-Series and Truebeam liancs will be presented and compared in graphical form and tabular data form if selected. Conclusion: The 6MV flattening filter (FF) beam data from C-Series & Truebeam and 6MV-FFF beam data from Truebeam has already presented. This particular analysis to compare 6MV-FFF beam from C-Series and Truebeam provides opportunity to better elaborate FFF mode on novel machines. It was found that C-Series and Truebeam 6MV-FFF dosimetric and beam data was quite similar.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-01: An Efficient Method of 3D Patient Dose Reconstruction Based On EPID Measurements for Pre-Treatment Patient Specific QA

Purpose: To demonstrate an efficient and clinically relevant patient specific QA method by reconstructing 3D patient dose from 2D EPID images for IMRT plans. Also to determine the usefulness of 2D QA metrics when assessing 3D patient dose deviations. Methods: Using the method developed by King et al (Med Phys 39(5),2839–2847), EPID images of IMRT fields were acquired in air and converted to dose at 10 cm depth (SAD setup) in a flat virtual water phantom. Each EPID measured dose map was then divided by the corresponding treatment planning system (TPS) dose map calculated with an identical setup, to derive a 2D “error matrix”. For each field, the error matrix was used to adjust the doses along the respective ray lines in the original patient 3D dose. All field doses were combined to derive a reconstructed 3D patient dose for quantitative analysis. A software tool was developed to efficiently implement the entire process and was tested with a variety of IMRT plans for 2D (virtual flat phantom) and 3D (in-patient) QA analysis. Results: The method was tested on 60 IMRT plans. The mean (± standard deviation) 2D gamma (2%,2mm) pass rate (2D-GPR) was 97.4±3.0% and the mean 2D gamma index (2D-GI) was 0.35±0.06. The 3D PTV mean dose deviation was 1.8±0.8%. The analysis showed very weak correlations between both the 2D-GPR and 2D-GI when compared with PTV mean dose deviations (R2=0.3561 and 0.3632 respectively). Conclusion: Our method efficiently calculates 3D patient dose from 2D EPID images, utilising all of the advantages of an EPID-based dosimetry system. In this study, the 2D QA metrics did not predict the 3D patient dose deviation. This tool allows reporting of the 3D volumetric dose parameters thus providing more clinically relevant patient specific QA.

60 APPLIED LIFE SCIENCES↗

Nonequilibrium electron and lattice dynamics of strongly correlated Bi 2 Sr 2 CaCu 2 O 8+δ single crystals

Here, the interplay between the electronic and lattice degrees of freedom in nonequilibrium states of strongly correlated systems has been debated for decades. Although progress has been made in establishing a hierarchy of electronic interactions with the use of time-resolved techniques, the role of the phonons often remains in dispute, a situation highlighting the need for tools that directly probe the lattice. We present the first combined megaelectron volt ultrafast electron diffraction and time- and angle-resolved photoemission spectroscopy study of optimally doped Bi 2 Sr 2 CaCu 2 O 8+δ . Quantitative analysis of the lattice and electron subsystems’ dynamics provides a unified picture of nonequilibrium electron-phonon interactions in the cuprates beyond the N-temperature model. The work provides new insights on the specific phonon branches involved in the nonequilibrium heat dissipation from the high-energy Cu–O bond stretching “hot” phonons to the lowest-energy acoustic phonons with correlated atomic motion along the <110> crystal directions and their characteristic time scales. It reveals a highly nonthermal phonon population during the first several picoseconds after the photoexcitation. The approach, taking advantage of the distinct nature of electrons and photons as probes, is applicable for studying energy relaxation in other strongly correlated electron systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying the topology of magnetic skyrmions in three dimensions

Magnetic skyrmions have so far been treated as two-dimensional spin structures characterized by a topological winding number. However, in real systems with the finite thickness of the device material being larger than the magnetic exchange length, the skyrmion spin texture extends into the third dimension and cannot be assumed as homogeneous. Using soft x-ray laminography, we reconstruct with about 20-nanometer spatial (voxel) size the full three-dimensional spin texture of a skyrmion in an 800-nanometer-diameter and 95-nanometer-thin disk patterned into a 30× [iridium/cobalt/platinum] multilayered film. A quantitative analysis finds that the evolution of the radial profile of the topological skyrmion number is nonuniform across the thickness of the disk. Estimates of the micromagnetic energy densities suggest that the changes in topological profile are related to nonuniform competing energetic interactions. Our results provide a foundation for nanoscale metrology for spintronics devices using topology as a design parameter.

36 MATERIALS SCIENCE↗

Next-generation wargames

Over the past century, and particularly since the outset of the Cold War, wargames (interactive simulations used to evaluate aspects of tactics, operations, and strategy) have become an integral means for militaries and policy-makers to evaluate how strategic decisions are made related to nuclear weapons strategy and international security. Furthermore, these methods have also been applied beyond the military realm, to examine phenomena as varied as elections, government policy, international trade, and supply-chain mechanics. Today, a renewed focus on wargaming combined with access to sophisticated and inexpensive drag-and-drop digital game development frameworks and new cloud computing architectures have democratized the ability to enable massive multiplayer gaming experiences. With the integration of simulation tools and experimental methods from a variety of social science disciplines, a science-based experimental gaming approach has the potential to transform the insights generated from gaming by creating human-derived, large-n datasets for replicable, quantitative analysis. In the following, we outline challenges associated with contemporary simulation and wargaming tools, investigate where scholars have searched for game data, and explore the utility of new experimental gaming and data analysis methods in both policy-making and academic settings.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Calculation of Transfer Functions of Multilayer Biotissues in the Problems of Correction of Their Fluorescence Spectra

A method for rapid calculation of a flux of stimulated fluorescence of a multilayer optically dense medium with inhomogeneous distribution of the fluorophore has been developed. The light field in the medium at the excitation wavelength of fluorescence is represented by a superposition of incident collimated, incident diffuse, and reflected diffuse fluxes. A two-stream approximation is used to describe the light field in the medium at the wavelength of emission of the fluorescence. Fluxes in adjacent elementary layers of the medium and on its surface are connected by simple matrix operators that are obtained using a combination of engineering approaches of radiation-transfer theory and single-scattering approximation. The calculations of fluorescence fluxes of a four-layer biotissue that are excited and recorded at 400–800 nm are compared with their Monte Carlo simulation with a discrepancy of 1%. The effect of the propagation medium on the fluorescence spectra of 5-ALA-induced protoporphyrin IX that are recorded from human skin was studied, and a technique for their correction that is based on measurements and quantitative analysis of the diffuse reflectance spectrum of skin was proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗