Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Focused Electron Beam-Based 3D Nanoprinting for Scanning Probe Microscopy: A Review

Scanning probe microscopy (SPM) has become an essential surface characterization technique in research and development. By concept, SPM performance crucially depends on the quality of the nano-probe element, in particular, the apex radius. Now, with the development of advanced SPM modes beyond morphology mapping, new challenges have emerged regarding the design, morphology, function, and reliability of nano-probes. To tackle these challenges, versatile fabrication methods for precise nano-fabrication are needed. Aside from well-established technologies for SPM nano-probe fabrication, focused electron beam-induced deposition (FEBID) has become increasingly relevant in recent years, with the demonstration of controlled 3D nanoscale deposition and tailored deposit chemistry. Moreover, FEBID is compatible with practically any given surface morphology. In this review article, we introduce the technology, with a focus on the most relevant demands (shapes, feature size, materials and functionalities, substrate demands, and scalability), discuss the opportunities and challenges, and rationalize how those can be useful for advanced SPM applications. As will be shown, FEBID is an ideal tool for fabrication/modification and rapid prototyping of SPM-tipswith the potential to scale up industrially relevant manufacturing.

36 MATERIALS SCIENCE↗

Kelvin Probe Force Microscopy in liquid using Electrochemical Force Microscopy

Conventional closed loop-Kelvin probe force microscopy (KPFM) has emerged as a powerful technique for probing electric and transport phenomena at the solid-gas interface. The extension of KPFM capabilities to probe electrostatic and electrochemical phenomena at the solid–liquid interface is of interest for a broad range of applications from energy storage to biological systems. However, the operation of KPFM implicitly relies on the presence of a linear lossless dielectric in the probe-sample gap, a condition which is violated for ionically-active liquids (e.g., when diffuse charge dynamics are present). Here, electrostatic and electrochemical measurements are demonstrated in ionically-active (polar isopropanol, milli-Q water and aqueous NaCl) and ionically-inactive (non-polar decane) liquids by electrochemical force microscopy (EcFM), a multidimensional (i.e., bias- and time-resolved) spectroscopy method. In the absence of mobile charges (ambient and non-polar liquids), KPFM and EcFM are both feasible, yielding comparable contact potential difference (CPD) values. In ionically-active liquids, KPFM is not possible and EcFM can be used to measure the dynamic CPD and a rich spectrum of information pertaining to charge screening, ion diffusion, and electrochemical processes (e.g., Faradaic reactions). EcFM measurements conducted in isopropanol and milli-Q water over Au and highly ordered pyrolytic graphite electrodes demonstrate both sample- and solvent-dependent features. Finally, the feasibility of using EcFM as a local force-based mapping technique of material-dependent electrostatic and electrochemical response is investigated. The resultant high dimensional dataset is visualized using a purely statistical approach that does not require a priori physical models, allowing for qualitative mapping of electrostatic and electrochemical material properties at the solid–liquid interface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Van Allen Probes observation of plasmaspheric hiss modulated by injected energetic electrons

Plasmaspheric hiss was observed by Van Allen Probe B in association with energetic electron injections in the outer plasmasphere. The energy of injected electrons coincides with the minimum resonant energy calculated for the observed hiss wave frequency. Interestingly, the variations in hiss wave intensity, electron flux and ultra low frequency (ULF) wave intensity exhibit remarkable correlations, while plasma density is not correlated with any of these parameters. Our study provides direct evidence for the first time that the injected anisotropic electron population, which is modulated by ULF waves, modulates the hiss intensity in the outer plasmasphere. This also implies that the plasmaspheric hiss observed by Van Allen Probe B in the outer plasmasphere ( L > ~5.5) is locally amplified. Meanwhile, Van Allen Probe A observed hiss emission at lower L shells ( < 5), which was not associated with electron injections but primarily modulated by the plasma density. The features observed by Van Allen Probe A suggest that the observed hiss deep inside the plasmasphere may have propagated from higher L shells.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrostatic Probe Measurements of Plasma Surrounding Three 25,000 Foot Per Second Reentry Flight Experiments

A high-altitude electrostatic probe experiment is described and data are presented for three RAM C reentries at velocities of approximately 25 OOO feet per second. The electron density profiles inferred from the probe measurements are compared with theoretical calculations, and the probable cause of significant disagreement is briefly discussed. Probe measurements during material-addition sequences for radio-blackout alleviation are presented, and comparisons of probe measurements with other pertinent diagnostic measurements are made.

W Linwood Jones, Jr↗

Transition region response of the symmetric double probe and its application in the lower ionosphere

The technique is discussed of the symmetric double-probe which readily lends itself to the in situ measurement of plasma temperature in the ionospheric D-region because it can lead to meaningful results under relatively high collision frequencies where the Langmuir probe has been observed to fail. It is shown that the modification to the original collision-free double-probe theory of Johnson and Malter for the determination of electron temperature is never greater than + or - 12%, with a value of (8 + or - 2)% nominally applicable in the case of D-region diagnostics. This technique was successfully operated on a Nike-Cajun payload flown at mid-day from White Sands, New Mexico to an apogee of 78.5 km. The associated electronics and deployed double-probe configuration are presented, and a current-voltage characteristic collected in the ascent stage at 73.7 km is briefly discussed. The values of electron temperature indicated by the sampled data are approximately 30% higher than those predicted by theory for the anticipated state of thermal equilibrium with the ambient neutrals.

Szuszczewicz, E. P.↗

Probe and radar electron temperatures in an isotropic nonequilibrium plasma.

Electron temperatures measured by electrostatic probes and radar backscatter are distinct physical quantities, the temperature from each technique determined from a different moment of the electron-distribution function. Numerical inequality of temperatures results from a non-Maxwellian electron-distribution function or, equivalently, from a nonequilibrium electron plasma. Probe and backscatter electron temperatures are studied for low- and high-energy (isotropic) distortions of the distribution function. The nonequilibrium plasma generally produces higher probe than backscatter temperatures; however, the temperature difference is small for distortions due to realistic photoelectron populations. If the ionosphere is in a highly nonequilibrium state, probe and backscatter temperatures would differ from the temperature characterizing the average electron kinetic energy, and a single temperature applicable to a variety of physical processes would no longer exist.

Hoegy, W. R.↗

D-region blunt probe data analysis using hybrid computer techniques

The feasibility of performing data reduction techniques with a hybrid computer was studied. The data was obtained from the flight of a parachute born probe through the D-region of the ionosphere. A presentation of the theory of blunt probe operation is included with emphasis on the equations necessary to perform the analysis. This is followed by a discussion of computer program development. Included in this discussion is a comparison of computer and hand reduction results for the blunt probe launched on 31 January 1972. The comparison showed that it was both feasible and desirable to use the computer for data reduction. The results of computer data reduction performed on flight data acquired from five blunt probes are also presented.

Burkhard, W. J.↗

A buoyant tornado-probe concept incorporating an inverted lifting device

Addition of an inverted lifting device to a simple balloon probe is shown to make possible low-altitude entry to tornado cores with easier launch conditions than for the simple balloon probe. Balloon-lifter combinations are particularly suitable for penetration of tornadoes with average to strong circulation, but tornadoes of less than average circulation which are inaccessible to simple balloon probes become accessible. The increased launch radius which is needed for access to tornadoes over a wide range of circulation results in entry times of about 3 minutes. For a simple balloon probe the uninflated balloon must be first dropped on, or near, the track of the tornado from a safe distance. The increase in typical launch radius from about 0.75 kilometer to slightly over 1.0 kilometer with a balloon-lifter combination suggests that a direct air launch may be feasible.

Grant, F. C.↗

Measuring probe position recorder

A device which enables a person to record the location of measurements made by a hand held nonconducting probe is described. The hand probe is coupled to a linear potentiometer and a sine-cosine potentiometer by means that varies the output of the linear potentiometer proportional to the distance between the hand probe and the linear potentiometer and that varies the output of the sine-cosine potentiometer proportional to the angular movement of the hand probe relative to the sine-cosine potentiometer. The output of the linear potentiometer is applied directly to one input of the sine-cosine potentiometer and is applied through an inverter to the other input or the sine-cosine potentiometer. The cosine and sine outputs of the sine-cosine potentiometer are applied to the X and Y outputs, respectively, of an X-Y recorder.

Flagge, B.↗

A model of the effect of the satellite photosheath on a double floating probe system

Description of a model developed to predict the interactions between multiple electrostatic probes separated by distances that are shorter than or comparable to the characteristic plasma shielding length. The computation involves crude approximations accounting for space charge effects, currents due to the emission and exchange of photoelectrons, and currents from the ambient plasma. Floating potentials are calculated by requiring current balance for each probe and solving by iterating the resulting coupled nonlinear equations. Although only qualitative accuracy is claimed, predictions using the model are found to be in good agreement with observations from the Explorer 45 satellite. The Explorer 45 satellite measures the potential difference between a pair of symmetrical spherical floating probes. The Explorer 45 data show that with increasing altitude, first, the sunward sphere will typically assume a more negative potential than the antisunward sphere; second, the polarities of the probes in the region L = 2 to 4 may switch, sometimes several times; and, finally, near the plasmapause the detector output may saturate, the sunward sphere being more negative.

Cauffman, D. P.↗

Evaluation of a wedge gas-sampling probe

The performances of a wedge-type gas-sampling probe and pitot probes are compared in applications to flowfield profile studies. The flow structure data obtained by these techniques are found to agree well in flow regions with and without significant gradients. The wedge-type probe showed a good service life and allowed a substantial reduction of the sampling time. The wedge probe design is discussed.

Beach, H. L., Jr.↗

Analysis of a Pneumatic Probe for Measuring Exhaust-Gas Temperatures with Some Preliminary Experimental Results

A pneumatic probe based on continuity of mass flow through two restrictions separated by a cooling chamber was constructed to measure gas temperature at and beyond the limit of thermocouples. This probe consisted of a subsonic flat-plate orifice for the first restriction and a sonic-flow converging-diverging nozzle for the second restriction. The effect of variation in gas constants on the calibration is examined for common engine-exhaust gases. A high-temperature wind tunnel that allowed calibration of the probe at temperatures up to 2000 deg R and. Mach numbers up to 0.8 is described. Agreement to better than 30 deg R between pneumatic probe indication and the indication of a rake of radiation shielded thermocouples indicates that extrapolation of the calibration to higher temperatures is possible with fair accuracy

Scadron, Marvin D.↗

Study of the adaptability of existing hardware designs to a Pioneer Saturn/Uranus probe

The basic concept of designing a scientific entry probe for the expected range of environments at Saturn or Uranus and making the probe compatible with the interface constraints of the Pioneer spacecraft was investigated for launches in the early 1980's. It was found that the amount of hardware commonality between that used in the Pioneer Venus program and that for the Saturn/Uranus probe was approximately 85%. It is recommended that additional development studies be conducted to improve the hardware definitions of the probe design for the following: heat shield, battery, nose cap jettisoning, and thermal control insulation.

Source record↗

Impact of science objectives and requirements on probe mission and system design

Problem areas in probe science technology are discussed that require a solution before probe systems can actually be designed. Considered are the effects of the model atmospheres on probe design; secondly, the effects of implementing the requirements to locate and measure the clouds and, trade-offs between descent sampling and measurement criteria as they affect probe system design.

Ledbetter, K. W.↗

The Pioneer spacecraft as a probe carrier

Requirements for Pioneer 10 and 11 designs are provided that are adequate to carry the probes for Jupiter and Saturn explorations. For a Uranus probe mission, additional spacecraft modifications are necessary. Considered are weight availability for carrying the probe, aspects of probe to bus link communications and onboard navigation.

Dixon, W.↗

Outer planet probe cost estimates: First impressions

An examination was made of early estimates of outer planetary atmospheric probe cost by comparing the estimates with past planetary projects. Of particular interest is identification of project elements which are likely cost drivers for future probe missions. Data are divided into two parts: first, the description of a cost model developed by SAI for the Planetary Programs Office of NASA, and second, use of this model and its data base to evaluate estimates of probe costs. Several observations are offered in conclusion regarding the credibility of current estimates and specific areas of the outer planet probe concept most vulnerable to cost escalation.

Niehoff, J.↗

Pioneer probe mission with orbiter option

A spacecraft is described which is based on Pioneer 10 and 11, and existing propulsion technology; it can transport and release a probe for entry into Jupiter's atmosphere, and subsequently maneuver to place the spacecraft in orbit about Jupiter. Orbital operations last 3 years and include maneuvers to provide multiple close satellite encounters which allow the orbit to be significantly changed to explore different parts of the magnetosphere. A mission summary, a guide to related documents, and background information about Jupiter are presented along with mission analysis over the complete mission profile. Other topics discussed include the launch, interplanetary flight, probe release and orbit deflection, probe entry, orbit selection, orbit insertion, periapsis raising, spacecraft description, and the effects of Jupiter's radiation belt on both orbiter and the probe.

Source record↗

Effects of geometric variables on the performance of a probe for direct measurement of free-steam stagnation pressure in supersonic flow

An investigation was conducted at Mach numbers of 1.41, 1.83, and 2.20 to determine the effects of parametric variations in the height of the pitot-tube center line from the probe surface and in the radius of the surface curvature on the pressure recovery of a probe designed to measure the free-stream stagnation pressure. The probe consists of a pitot tube mounted on the surface of a curved cylinder of circular cross section. The pitot tube senses the pressure of the stream tube which has been slowed by isentropic compression along the curved surface. Pressure recovery, greater than or equal to 99.8 percent of the free-stream stagnation pressure, was obtained for a wide range both of angle of attack and of yaw for probes satisfying the predetermined optimum design criteria.

Couch, L. M.↗