At least 901 records · Page 50

Modeling Framework for Evaluating Grid Disturbances

Recent research in the literature proposed parameter-based functional forms to quantify the impact of disturbances on electric power grids. This modeling was based on a concept of generalized grid disturbances that harmonized reliability and resilience. Three main stages—avoid, react, and recover—were identified, and to support practicality, were intended to be independently planned. An objective of the grid disturbance model was to fairly analyze the potential impacts of novel mitigations like transactive energy systems (TES) on grid reliability and resilience. Quantitative evaluation of a common performance metric (e.g., area under the curve of percentage customers online before, during, and after an event) over time was shown as an effective tool for such analysis. Such quantification may also enable system planners to assess the impact of appropriate mitigative actions for improving grid performance against potential disturbances. This is the focus of this report, i.e., presenting an evaluation modeling framework that can be utilized to evaluate grid performance against disturbances, under a variety of existing and possible new mitigative actions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault tree analysis: NiH2 aerospace cells for LEO mission

The Fault Tree Analysis (FTA) is one of several reliability analyses or assessments applied to battery cells to be utilized in typical Electric Power Subsystems for spacecraft in low Earth orbit missions. FTA is generally the process of reviewing and analytically examining a system or equipment in such a way as to emphasize the lower level fault occurrences which directly or indirectly contribute to the major fault or top level event. This qualitative FTA addresses the potential of occurrence for five specific top level events: hydrogen leakage through either discrete leakage paths or through pressure vessel rupture; and four distinct modes of performance degradation - high charge voltage, suppressed discharge voltage, loss of capacity, and high pressure.

Klein, Glenn C.↗

Hypervelocity Impact Test Facility: A gun for hire

An affordable technique has been developed to duplicate the types of impacts observed on spacecraft, including the Shuttle, by use of a certified Hypervelocity Impact Facility (HIF) which propels particulates using capacitor driven electric gun techniques. The fully operational facility provides a flux of particles in the 10-100 micron diameter range with a velocity distribution covering the space debris and interplanetary dust particle environment. HIF measurements of particle size, composition, impact angle and velocity distribution indicate that such parameters can be controlled in a specified, tailored test designed for or by the user. Unique diagnostics enable researchers to fully describe the impact for evaluating the 'targets' under full power or load. Users regularly evaluate space hardware, including solar cells, coatings, and materials, exposing selected portions of space-qualified items to a wide range of impact events and environmental conditions. Benefits include corroboration of data obtained from impact events, flight simulation of designs, accelerated aging of systems, and development of manufacturing techniques.

Johnson, Calvin R.↗

Real-Time Payload Control and Monitoring on the World Wide Web

World Wide Web (W3) technologies such as the Hypertext Transfer Protocol (HTTP) and the Java object-oriented programming environment offer a powerful, yet relatively inexpensive, framework for distributed application software development. This paper describes the design of a real-time payload control and monitoring system that was developed with W3 technologies at NASA Ames Research Center. Based on Java Development Toolkit (JDK) 1.1, the system uses an event-driven "publish and subscribe" approach to inter-process communication and graphical user-interface construction. A C Language Integrated Production System (CLIPS) compatible inference engine provides the back-end intelligent data processing capability, while Oracle Relational Database Management System (RDBMS) provides the data management function. Preliminary evaluation shows acceptable performance for some classes of payloads, with Java's portability and multimedia support identified as the most significant benefit.

Sun, Charles↗

Power Management and Distribution Trades Studies for a Deep-Space Mission Scientific Spacecraft

As part of NASA's Project Prometheus, the Nuclear Systems Program, NASA GRC performed trade studies on the various Power Management and Distribution (PMAD) options for a deep-space scientific spacecraft which would have a nominal electrical power requirement of 100 kWe. These options included AC (1000Hz and 1500Hz and DC primary distribution at various voltages. The distribution system efficiency, reliability, mass, thermal, corona, space radiation levels and technology readiness of devices and components were considered. The final proposed system consisted of two independent power distribution channels, sourced by two 3-phase, 110 kVA alternators nominally operating at half-rated power. Each alternator nominally supplies 50kWe to one half of the ion thrusters and science modules but is capable of supplying the total power re3quirements in the event of loss of one alternator. This paper is an introduction to the methodology for the trades done to arrive at the proposed PMAD architecture. Any opinions expressed are those of the author(s) and do not necessarily reflect the views of Project Prometheus.

Kimnach, Greg L.↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Valve Health Monitoring System Utilizing Smart Instrumentation

The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

Jensen, Scott L.↗

Protecting and Defending against Autonomous Control Systems and Digital Twin Cyber Attacks: Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Models in Nuclear Power Plants (Final)

Navigating through the complex tapestry of technological advancements, "Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Model in Nuclear Power Plants" stands at the intersection of cybersecurity and nuclear power plant operations, embarking on a journey through the intricacies of securing digital twins against malicious cyber activities. As nuclear power plants progressively integrate digital twin technology and machine learning models to optimize operations and ensure system reliability, they inadvertently expose themselves to a new spectrum of vulnerabilities, notably in the realm of hyperparameter attacks. Hyperparameters, integral in machine learning model tuning and optimal performance of digital twins, have emerged as a target for adversaries aiming to destabilize the predictive capabilities and therefore, the operational accuracy of these digital entities within critical infrastructures like nuclear plants. This paper, therefore, meticulously threads the needle through the development of a robust response strategy, poised to shield these digital reflections against calculated hyperparameter manipulations, ensuring that the digital twin can effectively and securely function as a reliable proxy for its physical counterpart. The ensuing sections delve into the orchestrated maelstrom of multi-rate time-changing intelligent coordinated hyperparameter attacks and the implementation of event-triggered predictive control, laying down a structured, predictive, and responsive framework that safeguards the nexus where the digital and physical realms of nuclear power plants coalesce. The operational integrity of digital twins in nuclear power plants depends critically on the security of machine learning hyperparameters. This study makes two different contributions. First, a decision-based idea known as a multi-rate time changing intelligent coordinated hyperparameter attack is put forth. In this attack, many hyperparameters are repeatedly changed using both random and intelligent optimal techniques by the attacker. These assaults introduce varied rates at different attack steps, compromise various amounts of hyperparameters, and improve stealth and flexibility. Second, a technique is developed for event triggered predictive control to rapidly respond to potential hyperparameter attacks. This control integrates a sliding window framework, retaining a history of previous data points and employing linear regression to predict the next data point from the current dataset. The control gain K is determined using the Lyapunov-Krasovskii method, and subsequently, an action is developed. Finally, the outcome of the simulation demonstrates the viability of the proposed method for defending nuclear power plant digital twins from hyperparameter attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine Learning Guided Operational Intelligence from Synchrophasors (Final Report)

Schweitzer Engineering Laboratories (SEL) and Oregon State University (OSU) received over 27 terabytes of electrical power system phasor measurement unit (PMU) data for the Eastern, Western, and ERCOT interconnections. The dataset includes measurements spread across 446 PMUs from early 2016 to mid 2018 depending on the interconnect. The full dataset was split into a training and test (holdout) dataset by PNNL. All data was received in the Apache Parquet format. The overarching goal of this project is to develop and execute a strategy to mitigate data anomalies, perform analysis on the dataset, and detect anomalous events in the data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Analysis of Inter-Area Oscillations in the US Eastern and Western Interconnections

This paper presents a comparative analysis of interarea oscillations in the US Eastern and Western Interconnections using frequency disturbance data collected from the advanced wide-area Frequency Monitoring Network (FNET/GridEye), enabling us to investigate and compare the oscillation characteristics of both regions. The study analyzes the statistical data from the two interconnections, including total oscillation events, average dominant frequencies, damping ratios, and maximum amplitudes. We also explore the impact of seasonal and daily variations on oscillation occurrences and the influence of different grid topologies and operational practices. The results provide insights into both interconnections' stability and control characteristics, offering valuable information for power system operators to enhance grid stability and oscillation suppression measures.

Fu, Hao [University of Tennessee, Knoxville (UTK)]↗

Special Issue: Thermal Energy Storage for Buildings

This special issue (SI) of the ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC) features peer-reviewed papers specific to technologies and applications of thermal energy storage (TES) for buildings. TES systems store energy in materials as a heat source or a cold sink and then discharge the stored energy hours or weeks later to enhance thermal comfort or reduce utility bills [1]. As buildings and cities are facing increasing energy consumption and extreme weather events, TES offers a powerful solution to balance supply and demand, reduce operational energy costs, and strengthen energy resilience during power outages.

25 ENERGY STORAGE↗

High-Efficiency, Medium-Voltage-Input, Solid-State-Transformer-Based 400-kW/1000V/400A Extreme Fast Charger for Electric Vehicles

Range anxiety and long battery charging time continue to be critical challenges to mass adaptation of EVs. A major identified gap to wider adoption of BEVs is the ability and availability to refuel quickly or to fast charge. Studies have shown that in areas where drivers have access to 50-kW or 120-kW fast charge stations, annual electric vehicle (EV) miles traveled (i.e., eVMT) increased by over 25%, even in cases where fast charging was used for 1% to 5% of total charging events. Charge stations of higher power not only alleviate the “range anxiety” and reduce the driver’s waiting time, but also requires less investment. Michigan Energy Office completed a study in early 2019 titled “Electric Vehicle Charger Placement Optimization in Michigan: Phase I – Highways”. This study finds a system with 150kW chargers, though more expensive individually, actually has lower total system cost when compared to a 50kW charging system when serving the same battery size EV. To be truly competitive to the ICEV refueling experience, even higher power stations are necessary. However, high power charge stations would create large power draws from the grid. If this occurs during peak demand periods, grid capacity could be overloaded. This problem needs to be addressed to reduce the impact on the electric utility infrastructure. The main goal of this project is to develop a 400-kW/400-A XFC system targeting total efficiency of 96.5 percent from the MVAC grid to a vehicle. The novel SST power cell topology, combined with a new silicon carbide (SiC) MOSFET device, enables a 3.5 percent improvement in system efficiency, a 50-percent smaller equipment footprint, and four times less weight than today’s DCFC systems. The SST technology would directly utilize MVAC at 4.8-kV or 13.2-kV. This would eliminate the line frequency transformer (LFT), which steps down medium-voltage AC to 3-Phase 480-V line-to-line voltage in current DCFC systems.

42 ENGINEERING↗

Typical Use Cases for Energy Storage in Rural Areas

Public power utilities and cooperatives play a crucial role in delivering reliable and affordable electricity to remote and sparsely populated regions. Unlike their urban counterparts, these utilities often face a unique set of challenges that can complicate their operations and service delivery. One of the primary challenges is the vast geographical area they must cover, which often results in higher transmission and distribution costs per customer. Additionally, public power utilities in rural areas often cannot afford the investments required to maintain and upgrade aging grid infrastructure to provide reliable and resilient power or withstand the impacts of recurring, severe weather events, which can cause extended outages and disrupt service delivery. Energy storage has emerged as a promising tool to help public power utilities meet these challenges. By enabling the storage of excess energy during low demand periods and providing a source of backup electricity during outages, energy storage systems can help utilities balance supply and demand more effectively. Additionally, they can help integrate a portfolio of various energy sources, reduce the need for expensive peak power purchases and provide ancillary services that stabilize the grid. This white paper describes potential use cases for energy storage in rural areas as well as documents a set of relevant example projects by project types.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary design of a flight control system for a V/STOL airplane with geared variable pitch fans

A flight control system designed for an aircraft powered by three variable pitch fans, interconnected by shafts to provide lifting system redundancy is considered for application to a Navy Type A V/STOL aircraft with similar configurational features. The differences and similarities in the applications are discussed with emphasis on a design approach for safety in the event of failures in the propulsion and flight control systems. Differences in flying qualities and system design criteria are considered.

Gotleib, P.↗

Should Astronauts throw out their Trash? And if so, How?

We don’t think much about taking out the trash on Earth, but in space, it requires some thought. Should it even be thrown overboard? Besides the implications of littering in space, there are also practical considerations of whether waste materials can be reused for other purposes onboard or do they reduce mission efficiency. In a previous study, gasifying and venting trash along the way to Mars was found to noticeably reduce propellant needs and launch mass of the spacecraft, whereas keeping processed trash on board in the form of radiation shielding tiles would significantly lower the crew’s radiation dose during a solar particle event. The latest human exploration mission proposals will be considered with an eye toward answering the questions, “Should Astronauts throw out their Trash?” and “If so, what is the best way?” Besides reviewing the propulsion and radiation shielding aspects of the question, equivalent system mass factors of mass, power, volume, and crew time, as well as human factors, like smell, will be studied. Disposal options include jettison of an entire module containing waste, regular disposal of trash via an airlock, or gasifying waste products for easier disposal or reuse. Jettison via an airlock could take many forms, from “taking out the trash” on a spacewalk to launching trash tiles or pods with different mechanisms. Likewise, the “trash-to-gas” concept, which would allow for overboard venting via a pipe, has many thermochemical processes to choose from, each with their own pros and cons. Unraveling these various tradeoff studies is the goal of this paper.

trash↗

The resilience value of residential solar + storage systems in the continental U.S.

Abstract Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.

Baik, Sunhee↗

Characterization of Precipitation-Induced Radon Progeny Deposition Events Using a City-Scale Sensor Network

Networks of radiation detectors provide a platform for real-time radioactive source detection and identification in urban environments. Detection algorithms in these systems must adapt to naturally-occurring changes in background, which requires well-characterized relationships between precipitation events and their corresponding radiological signature. Here, we present a quantitative and qualitative description of rain-induced radon progeny deposition events occurring in Chicago from September 2023 to February 2024. We measure ambient gamma radiation levels, precipitation rate, temperature, pressure, and relative humidity in a network of sensor nodes. For each identified precipitation period, we decompose spectra into static- and radon-associated components as defined by a non-negative matrix factorization (NMF) algorithm. We find a consistent power-law relationship between a precipitation-dependent peak of the radon progeny proxy (RPP) and the peak strength of the radon-associated NMF component for most precipitation events. We conduct a case study of a rainfall period with abnormally high levels of implied radon progeny concentration and describe its temporal and spatial evolution. We hypothesize that this phenomenon is due to the air mass path that intersects a uranium-rich region of Wyoming. Finally, we cluster precipitation events into three distinct categories. One category roughly corresponds to events with deep low-pressure systems and high relative radon concentration, while another is characteristic of light stratiform rain with slightly higher temperatures and intermediate relative radon concentration. The third category appears to contain weak-gradient or lake breeze convection showers with intermittent precipitation and low relative radon concentration. These findings suggest that radiological anomaly detection could be improved by training unique background models corresponding to each category of meteorological event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FORTE Measurements of Global Optical Lightning Waveforms and Implications for Optical Lightning Detection

Lightning processes generate a diverse collection of optical pulses from current traversing the lightning channels. These signals are then broadened spatially and temporally via scattering in the clouds. The resulting waveforms measured from space with instruments like the photodiode detector (PDD) on the Fast On-orbit Recording of Transient Events (FORTE) satellite have a variety of shapes. In this study, we use coincident optical and Radio-Frequency measurements to document the properties of optical PDD waveforms associated with different types of lightning, estimate delays from scattering in the clouds, and comment on how pulse shape impacts optical lightning detection. We find that the attributes of optical pulses recorded by the PDD are consistent with prior studies, but vary globally and with event amplitude. The most powerful lightning tends to be single-peaked with faster rise times (median: ~100 µs) and shorter effective widths (median: ~400 µs) than normal lightning. Particularly dim events, meanwhile, include cases of broad optical waveforms with sustained optical emission throughout the PDD record, which the pixelated FORTE Lightning Location System (LLS) instrument has difficulty detecting. We propose that this is due to the optical signal being divided between individual LLS pixels that are each, individually, not bright enough to trigger. We use PDD waveforms and Monte Carlo radiative transfer modeling to demonstrate that increasing the temporal and spatial resolution of a pixelated lightning imager will make it more difficult to detect these broad/dim pulses as their energy becomes divided between additional pixels/integration frames.

54 ENVIRONMENTAL SCIENCES↗