Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Flexible transparent conducting electrodes unexpectedly influence MAPbI 3 film morphology and perovskite solar cell performance

Fabricating perovskite solar cells (PSCs) on plastic substrates will enable cost-effective manufacturing of lightweight and portable energy systems. Here, we study the influence of flexible transparent conductive electrodes (TCEs) on the methylammonium lead iodide (MAPbI3) film morphology and PSC performance. Three types of TCEs on polyethylene terephthalate (PET) are compared: a custom-made AgNWs/indium zinc oxide hybrid TCE and two commercial substrates with indium tin oxide (ITO) or metal/insulator/metal (MIM) as the TCE. Using the same p-i-n architecture and hole transport layer (HTL), we find that PSCs fabricated on the hybrid TCE show better performance and stability compared to those made on commercial TCEs. The PSC performance enhancement is attributed to the superior structural and optical properties of MAPbI3 film deposited on the hybrid TCE, which is explained by the surface energy difference of the HTL. While it is anticipated that solar cell performance can be affected by TCEs’ transmittance and sheet resistance as they determine light absorption and carrier transport, respectively, our finding of TCE influencing the morphology and crystallinity of MAPbI3 film, and hence PSC performance, is unexpected.

14 SOLAR ENERGY↗

LaRIS: Targeting Portability and Productivity for LAPACK Codes on Extreme Heterogeneous Systems by Using IRIS

In keeping with the trend of heterogeneity in high-performance computing, hardware manufacturers and vendors are developing new architectures and associated software stacks (e.g., libraries) to harness the best possible performance from commonly used kernels (e.g., linear algebra kernels). However, kernels tuned for one architecture are not portable to others. Moreover, the coexistence of different architectures in a single node makes orchestration difficult. To address these challenges, we introduce LaRIS, a portable framework for LAPACK functionalities. LaRIS ensures a separation between linear algebra algorithms and vendor-library kernels by using the IRIS run time and IRIS-BLAS library. Such abstraction at the algorithm level makes the implementation completely agnostic to the vendor library and architecture. LaRIS uses the IRIS run time to dynamically select the vendor-library kernel and suitable processor architecture at run time. Through LU factorization, we demonstrate that LaRIS can fully utilize different heterogeneous systems by launching and orchestrating different vendor-library kernels without any change in the source code.

Monil, M. A. H.↗

Use of a New Portable Instrumented Impactor on the NASA Composite Crew Module Damage Tolerance Program

Damage tolerance performance is critical to composite structures because surface impacts at relatively low energies may result in a significant strength loss. For certification, damage tolerance criteria require aerospace vehicles to meet design loads while containing damage at critical locations. Data from standard small coupon testing are difficult to apply to larger more complex structures. Due to the complexity of predicting both the impact damage and the residual properties, damage tolerance is demonstrated primarily by testing. A portable, spring-propelled, impact device was developed which allows the impact damage response to be investigated on large specimens, full-scale components, or entire vehicles. During impact, both the force history and projectile velocity are captured. The device was successfully used to demonstrate the damage tolerance performance of the NASA Composite Crew Module. The impactor was used to impact 18 different design features at impact energies up to 35 J. Detailed examples of these results are presented, showing impact force histories, damage inspection results, and response to loading.

Jackson, Wade C.↗

3D LiMn 2 O 4 nThin Film Deposited by ALD: A Road toward High-Capacity Electrode for 3D Li-Ion Microbatteries

Miniaturized electronics suffer from a lack of energy autonomy. In that context, the fabrication of lithium-ion solid-state microbatteries with high performance is mandatory for powering the next generation of portable electronic devices. Here, the fabrication of a thin film positive electrode for 3D Li-ion microbatteries made by the atomic layer deposition (ALD) method and in situ lithiation step is demonstrated. The 3D electrodes based on spinel LiMn 2 O 4 films operate at high working potential (4.1 V vs Li/Li + ) and are capable of delivering a remarkable surface capacity (approximate to 180 mu Ah cm -2 ) at low C-rate while maintaining more than 40 mu Ah cm -2 at C/2 (time constant = 2 h). Both the thickness of the electrode material and the 3D gain of the template are carefully tuned to maximize the electrode performance. Further, advanced characterization techniques such as transmission electron and X-ray transmission microscopies are proposed as perfect tools to study the conformality of the deposited films and the interfaces between each layer: no interdiffusion or segregation are observed. This work represents a major issue towards the fabrication of 3D-lithiated electrode by ALD-without any prelithiation step by electrochemical technique-making it an attractive solution for the fabrication of 3D Li-ion solid-state microbatteries with semiconductor processing methods.

3D Li-ion micro-batteries↗

Hybrid Graphene Ribbon/Carbon Electrodes for High‐Performance Energy Storage

Abstract The utility of supercapacitors for both fixed and portable energy storage would be greatly enhanced if their energy density could be increased while maintaining their high power density, fast charging time, and low cost. This study describes a simple, solution‐phase, scalable modification of carbon materials by a covalently bonded “brush” of hydrogen‐terminated graphene ribbons (GRs) with layer thicknesses of 2–20 nm, resulting in a 20–100 times increase in the areal capacitance of the unmodified electrode surface. On a flat sp 2 carbon surface modified by GRs, the capacitance exceeds 1200 µF cm −2 in 0.1 m H 2 SO 4 due to a distinct type of pseudocapacitance during constant current charge/discharge cycling. Modification of high surface area carbon black electrodes with GRs yields capacitances of 950–1890 F g −1 , power densities >40 W g −1 , and minimal change in capacitance during 1500 charge/discharge cycles at 20 A g −1 . A capacitance of 1890 F g −1 affords an energy density of 318 Wh kg −1 operating at 1.1 V and 590 Wh kg −1 at 1.5 V. The projected energy density of a hybrid GR/carbon supercapacitor greatly exceeds the current 10 Wh kg −1 for commercial supercapacitors and approaches that of lithium ion batteries.

Farquhar, Anna K.↗

Portable Tank Storage Pit Technical Documents and Associated Flooring Documents

The work performed under this section includes the surface preparation and application of protective floor coatings; furnishing all labor, materials, and equipment necessary to perform all operations in connection with the application required for satisfactory completion in accordance with the standards and practices set forth herein.

99 GENERAL AND MISCELLANEOUS↗

IMPROVING INTERMEDIATE TEMPERATURE PERFORMANCE OF NI-YSZ CERMET ANODES FOR SOLID OXIDE FUEL CELLS BY INFILTRATION OF NICKEL NANOPARTICLES AND MIXED IONIC ELECTRONIC CONDUCTOR

Solid oxide fuel cells (SOFCs) are one of the most efficient and environment-friendly devices for electricity generation. One critical challenge of SOFC commercialization is high cell operating temperatures (800°C-1000°C), which lead to high material costs, high performance degradation rates, long start-up and shutdown times, and limited portable applications. Intermediate temperature (600°C-800°C) operation of SOFCs is limited by sluggish electrode reaction kinetics. The objective of this research is to improve intermediate temperature performance of commercially available Ni-YSZ cermet anode supported SOFCs by liquid infiltration of the anode. One effective method to improve kinetics of electrochemical reactions at the anode is to increase the density of reaction sites, which are known as the triple phase boundaries (TPBs). The porous Ni-YSZ cermet anodes were liquid infiltrated with Ni nanoparticles, leading to a four-fold increase in TPB density in the anode. The improved electrochemical performance of the infiltrated cells compared to the uninfiltrated cells highlights the effectiveness of anode infiltration in facilitating improved anode electrochemical reaction kinetics. However, the post-electrochemical testing characterization revealed that Ni nanoparticles were not stable due to Ni coarsening and were mostly isolated indicating that not all of the additional TPBs were fully utilized in electrochemical reactions due to the lack of an electronic pathway between the Ni nanoparticles. In order to improve microstructural stability of the infiltrated Ni nanoparticles, and to fully utilize the added TPBs, co-infiltration of Ni with a mixed ionic and electronic conductor (MIEC) was carried out. Two MIEC materials are chosen based on their chemical stability and conductivity in the anode operating environments; Gd 0.1 Ce 0.9 O 2-δ (GDC), a predominantly an ionic conductor, and La 0.6 Sr 0.3 Ni 0.15 Cr 0.85 O 3-δ (LSNC), a predominantly electronic conductor, and cells were successfully co-infiltrated to form Ni-GDC and Ni-LSNC nanostructures with the MIEC phases connecting the Ni nanoparticles. Stability tests demonstrated that both MIECs inhibited Ni nanoparticle coarsening. Electrochemical studies showed that Ni-GDC is the most effective for improved anode kinetics. A long-term (120 hours) electrochemical test indicated that infiltration of Ni-GDC into Ni-YSZ cermet anode effectively improves overall cell performance at intermediate temperatures and maintains the performance gain for a long period of time.

Lu, Yanchen↗

Portable aircraft controller devices and systems

A portable computerized device for an aircraft control system includes an input system for inputting commands, a device display for displaying information on the computerized device, a processor, a wireless communication module, and a non-transitory computer readable medium comprising computer executable instructions, the computer executable instructions configured to cause the processor to perform a method. The method can include detecting whether the portable computerized device is in a cockpit state such that the portable computerized device is in and/or docked to an aircraft cockpit or if the portable computerized device is in a remote state such that the portable computerized device is not in an aircraft cockpit or is not docked to an aircraft cockpit. If the portable computerized device is determined to be in a remote state, the method includes operating the remote device in a remote mode. If the portable computerized device is determined to be in a cockpit state, the method includes operating the device in a local mode.

Sahay, Prateek↗

The Design and Evaluation of "CAPTools"--A Computer Aided Parallelization Toolkit

Writing applications for high performance computers is a challenging task. Although writing code by hand still offers the best performance, it is extremely costly and often not very portable. The Computer Aided Parallelization Tools (CAPTools) are a toolkit designed to help automate the mapping of sequential FORTRAN scientific applications onto multiprocessors. CAPTools consists of the following major components: an inter-procedural dependence analysis module that incorporates user knowledge; a 'self-propagating' data partitioning module driven via user guidance; an execution control mask generation and optimization module for the user to fine tune parallel processing of individual partitions; a program transformation/restructuring facility for source code clean up and optimization; a set of browsers through which the user interacts with CAPTools at each stage of the parallelization process; and a code generator supporting multiple programming paradigms on various multiprocessors. Besides describing the rationale behind the architecture of CAPTools, the parallelization process is illustrated via case studies involving structured and unstructured meshes. The programming process and the performance of the generated parallel programs are compared against other programming alternatives based on the NAS Parallel Benchmarks, ARC3D and other scientific applications. Based on these results, a discussion on the feasibility of constructing architectural independent parallel applications is presented.

Yan, Jerry↗

A Portable High-Density Power Technology for Space, Lunar, and Planetary Applications

A new direct energy conversion concept called Nuclear Thermionic Avalanche Cell (NTAC) combined with a Metallic Junction Thermoelectric (MJ-TE) generator, both invented and patented by NASA, offers high specific power for portable applications. Estimates based on experimental results suggest superior performance compared to radioisotope thermoelectric generators (RTG) by up to two orders of magnitude for the NTAC and three to four times better for the MJ-TE generator for the same mass. The NTAC technology can use a variety of radioisotopes including nuclear waste to liberate a large number of intra-band(IB), inner shell electrons of atoms (105 C/cm3) by gamma-ray photons (100 keV to MeV). In contrast, conventional power generation has poor specific power because they only utilize the valence band electrons (3C/cm3) of the semiconductor or free electrons (8×103 C/cm3) of the conductor.

NTAC↗

Subcritical Copper-Reflected-α-phase Plutonium (SCRαP) Integral Experiment Design

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment is proposed where multiplication will be approximated using correlated neutron data from a detector system consisting of {sup 3}He tubes inside polyethylene. Measurements will be performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations are planned with the plutonium ball nested in various thicknesses of interleaved polyethylene spherical shells mixed in with the Cu shells. The polyethylene is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity. The proposed experiments will performed at the National Criticality Experiments Research Center (NCERC). NCERC is home to a 4.5-kg α-phase stainless steel clad plutonium sphere that is referred to as the BeRP (Beryllium-Reflected Plutonium) ball due to its historical use in a beryllium-reflected critical experiment. In 2014, similar subcritical measurements were performed with the BeRP ball surrounded by nickel and tungsten. The nickel-reflected measurements were documented as a benchmark evaluation which was accepted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Similar to past measurements, the proposed work will help both identify deficiencies and quantify uncertainties in nuclear data and validate computational methods related to neutron multiplication inference for subcritical benchmark evaluations. Monte Carlo simulations were performed for the preliminary design of a subcritical Copper-Reflected - phase Plutonium (SCRP) integral benchmark experiment. Specifically, MCNP{sup R} version 6 was used to determine the k{sub eff} and associated nuclear data sensitivities for different preliminary configurations (reflector thickness, material type). The final experimental design process will include continuous-energy nuclear data sensitivity analysis. This will help assess the potential impact of this integral measurement as it relates to international efforts to continuously improve current libraries (ENDF, JEFF, JENDL etc) that still tend to over/under-estimate the measured results of integral experiments, sometimes significantly. Deficiencies in underlying nuclear data quantities such as Nubar have been shown to have an effect on inferred values from subcritical measurements as well. The proposed experiments and subsequent computational validation will help identify such deficiencies. It will also help validate new nuclear data evaluations, including one for Cu that was recently performed in the resolved region up to 100 MeV for {sup 65}Cu and {sup 63}Cu which is expected to improve Cu-related benchmark simulation performance. The final experimental design phase will also include simulation results that will incorporate the detectors that will be used for the subcritical measurements. For the benchmark portion of the measurements, the main detectors that are being considered are portable neutron multiplicity counters made up of {sup 3}He tubes embedded in polyethylene and lined with cadmium. These detectors employ a data acquisition system that produces list-mode data (correlated information where each event is listed sequentially) that can be analyzed using the Feynman variance-to-mean method. Other detector systems including SNAP (single {sup 3}He tube embedded in polyethylene), and a high-purity germanium (HPGe) detector are being considered for supplementary measurements only and are not intended to be used for the final benchmark measurements. Decoupling the supplementary detectors from the system eliminates any contribution to the total system multiplication, and greatly simplifies the final computational benchmark model. Therefore, an optimization of the portable neutron multiplicity counter placement in the benchmark measurements will be performed to ensure that there is minimal contribution to the total system multiplication. In addition, new temperature measurement techniques and hardware will be explored. (authors)

42 ENGINEERING↗

Development of autonomous magnetometer rotorcraft for wide area assessment

Large areas across the United States are potentially contaminated with UXO, with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with 1) near 100 % coverage and 2) near 100 % detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 – 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys (resulting in costs of approximately $100-$150/acre). In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide high resolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. There is thus a need for other systems which can be used for effective data collection. An UAV (Unmanned Aerial Vehicle) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly characterization (through the use of dynamic acquisition, i.e. survey mission inflight reprioritization). We describe and report on a one year effort with as primary goal to provide a recommendation to SERDP for a path forward in the implementation of one or more autonomous unmanned magnetometer rotorcraft platforms. This recommendation (which is provided in chapter 6) is based on the following three elements a) An assessment on the applicability of autonomous rotorcraft magnetometer systems to the current DoD site inventory, and an initial assessment of which type(s) of autonomous unmanned magnetometer rotorcraft platforms (in terms of performance characteristics such as payload, altitude, obstacle avoidance, production rate and flight time) would be most relevant to this inventory (chapter 3); b) An evaluation of the feasibility of assembling such platforms from commercial components (unmanned rotorcraft, control systems and sensors – both magnetometer sensors and supporting sensors). This evaluation included several highly successful field tests (chapter 4 and 5); c) A recommendation of the path forward, which includes a detailed outline of the efforts required in the design, assembly and testing of different modular platforms (chapter 6)

58 GEOSCIENCES↗

On the Efficacy of Isolating Shoulder and Elbow Movements with a Soft, Portable, and Wearable Robotic Device

Treatment intensity has a profound effect on motor recovery following neurological injury. The use of robotics has potential to automate these labor-intensive therapy procedures that are typically performed by physical therapists. Further, the use of wearable robotics offers an aspect of portability that may allow for rehabilitation outside the clinic. The authors have developed a soft, portable, lightweight upper extremity wearable robotic device to provide motor rehabilitation of patients with affected upper limbs due to traumatic brain injury (TBI). A key feature of the device demonstrated in this paper is the isolation of shoulder and elbow movements necessary for effective rehabilitation interventions. Herein is presented a feasibility study with one subject and demonstration of the device's ability to provide safe, comfortable, and controlled upper extremity movements. Moreover, it is shown that by decoupling shoulder and elbow motions, desired isolated joint actuation can be achieved.

Kadivar, Zahra↗

Portable Neutron Sensors for Emergency Response Operations

This article presents the experimental work performed in the area of neutron detector development at the Remote Sensing Laboratory–Andrews Operations (RSL-AO) sponsored by the U.S. Department of Energy, National Nuclear Security Administration (NNSA) in the last four years. During the 1950s neutron detectors were developed mostly to characterize nuclear reactors where the neutron flux is high. Due to the indirect nature of neutron detection via interaction with other particles, neutron counting and neutron energy measurements have never been as precise as gamma-ray counting measurements and gamma-ray spectroscopy. This indirect nature is intrinsic to all neutron measurement endeavors (except perhaps for neutron spin-related experiments, viz. neutron spin-echo measurements where one obtains μeV energy resolution). In emergency response situations generally the count rates are low, and neutrons may be scattered around in inhomogeneous intervening materials. It is also true that neutron sensors are most efficient for the lowest energy neutrons, so it is not as easy to detect and count energetic neutrons. Most of the emergency response neutron detectors are offshoots of nuclear device diagnostics tools and special nuclear materials characterization equipment, because that is what is available commercially. These instruments mostly are laboratory equipment, and not field-deployable gear suited for mobile teams. Our goal is to design and prototype field-deployable, ruggedized, lightweight, efficient neutron detectors.

61 RADIATION PROTECTION AND DOSIMETRY↗

A bending test protocol for characterizing the mechanical performance of flexible photovoltaics

Flexible photovoltaics (PV) represents a promising research field with great potential for wearable, portable, and indoor applications. Significant progress has been made in recent years, with flexible emerging PV reporting power conversion efficiency (PCE) over 24%. Yet, there is a need for a unifying protocol to assess PV performance, compare research results, and evaluate the state- of-the-art achievements in flexible PV. In this paper, a consensus protocol is presented for measuring PCE over 1,000 bending cycles under 1% strain. Moreover, several good practice guidelines are proposed including bending procedures, flexibility testing with and without encapsulation, and ambient conditions during testing (e.g., temperature, humidity, illumination). Notably, the importance of uniform application of bending radius and the testing of parallel and perpendicular orientations of bending axis with respect to the direction of the electric current are emphasized. These recommendations aim to promote consistency in device comparison and allow for better reproducibility.

Fukuda, Kenjiro↗