Error Modeling of Multibaseline Optical Truss: Part 1: Modeling of System Level Performance

Global astrometry is the measurement of stellar positions and motions. These are typically characterized by five parameters, including two position parameters, two proper motion parameters, and parallax. The Space Interferometry Mission (SIM) will derive these parameters for a grid of approximately 1300 stars covering the celestial sphere to an accuracy of approximately 4uas, representing a two orders of magnitude improvement over the most precise current star catalogues. Narrow angle astrometry will be performed to a 1uas accuracy. A wealth of scientific information will be obtained from these accurate measurements encompassing many aspects of both galactic (and extragalactic science. SIM will be subject to a number of instrument errors that can potentially degrade performance. Many of these errors are systematic in that they are relatively static and repeatable with respect to the time frame and direction of the observation. This paper and its companion define the modeling of the, contributing factors to these errors and the analysis of how they impact SIM's ability to perform astrometric science.

meterology modeling↗

Low-coherence interferometry as a method for assessing the transport parameters in randomly inhomogeneous media

The specific features of using low-coherence interferometric probing of layers in randomly inhomogeneous media for determination of the radiation propagation transport length both in diffuse regime and in the case of optically thin media are discussed. The transport length is determined by the rate of exponential decay of the interference signal with the increase in the path length difference between the light beams in the reference arm of the low-coherence interferometer and in the object arm, containing the probed layer as a diffuse reflector. The results are presented of experimental testing of the discussed approach with the use of layers of densely packed titanium dioxide nanoparticles and polytetrafluoroethylene. (radiation scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High density plasmas and new diagnostics: An overview (invited)

One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined single-pulse holography and time-resolved laser schlieren for flow visualization

A pulsed ruby laser and continuous-wave argon ion laser were used in a combined setup at the Langley Expansion Tube for single pulse holography and time resolved laser schlieren with a common optical axis. The systems can be operated simultaneously for a single run. For a single frame, the pulsed holographic setup offers the options of shadowgraph, Schlieren, and interferometry from the reconstructed hologram as well as the advantage of post-run sensitivity adjustments. For flow establishment studies the time resolved laser Schlieren provides visualization of the flow field every 12.5 microns for up to 80 frames with an exposure time per frame of 5.4 microns.

Burner, A. W.↗

Separation processes during binary monotectic alloy production

Observation of microgravity solidification processes indicates that outside of sedimentation, at least two other important effects can separate the phases: critical-point wetting and spreading; and thermal migration of second-phase droplets due to interfacial tension gradients. It is difficult to study these surface tension effects while in a unit gravity field. In order to investigate the processes occurring over a temperature range, i.e., between a consolute point and the monotectic temperature, it is necessary to use a low-gravity environment. The MSFC drop tube (and tower), the ballistic trajectory KC-135 airplane, and the Space Shuttle are ideal facilities to aid formation and testing of hypotheses. Much of the early work in this area focuses on transparent materials so that process dynamics may be studied by optical techniques such as photography for viewing macro-processes; holography for studying diffusional growth; spinodal decomposition and coalescence; ellipsometry for surface wetting and spreading effects; and interferometry and spectroscopy for small-scale spatial resolution of concentration profiles.

Frazier, D. O.↗

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

In general, the inherent statistical variances in the laser-driven plasma accelerators (LPAs) and self-amplified spontaneous emission (SASE) free electron lasers (FELs) motivate the use of single-shot diagnostics. In addition, the microbunching phenomenon in each is also variable, so coherent optical transition radiation (COTR) techniques also warrant single-shot evaluations. In both cases, the enhancements of the signals enable optical beam splitters to be used to direct light to the different measuring devices for electron beam size, divergence, spectral content, and/or bunch length as appropriate. COTR Interferometry (COTRI) modelling results for the pre-buncher case at 266 nm and for the LPA case at 633 nm are presented. In addition, examples of few-micron beam size and sub-mrad beam divergence measurements from a single shot of an LPA are reported.

43 PARTICLE ACCELERATORS↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

NASA Tech Briefs, November 2008

Topics covered include: Digital Phase Meter for a Laser Heterodyne Interferometer; Vision System Measures Motions of Robot and External Objects; Advanced Precipitation Radar Antenna to Measure Rainfall From Space; Wide-Band Radar for Measuring Thickness of Sea Ice; Vertical Isolation for Photodiodes in CMOS Imagers; Wide-Band Microwave Receivers Using Photonic Processing; L-Band Transmit/Receive Module for Phase-Stable Array Antennas; Microwave Power Combiner/Switch Utilizing a Faraday Rotator; Compact Low-Loss Planar Magic-T; Using Pipelined XNOR Logic to Reduce SEU Risks in State Machines; Quasi-Optical Transmission Line for 94-GHz Radar; Next Generation Flight Controller Trainer System; Converting from DDOR SASF to APF; Converting from CVF to AAF; Documenting AUTOGEN and APGEN Model Files; Sequence History Update Tool; Extraction and Analysis of Display Data; MRO DKF Post-Processing Tool; Rig Diagnostic Tools; MRO Sequence Checking Tool; Science Activity Planner for the MER Mission; UAVSAR Flight-Planning System; Templates for Deposition of Microscopic Pointed Structures; Adjustable Membrane Mirrors Incorporating G-Elastomers; Hall-Effect Thruster Utilizing Bismuth as Propellant; High-Temperature Crystal-Growth Cartridge Tubes Made by VPS; Quench Crucibles Reinforced with Metal; Deep-Sea Hydrothermal-Vent Sampler; Mars Rocket Propulsion System; Two-Stage Passive Vibration Isolator; Improved Thermal Design of a Compression Mold; Enhanced Pseudo-Waypoint Guidance for Spacecraft Maneuvers; Altimetry Using GPS-Reflection/Occultation Interferometry; Thermally Driven Josephson Effect; Perturbation Effects on a Supercritical C7H16/N2 Mixing Layer; Gold Nanoparticle Labels Amplify Ellipsometric Signals; Phase Matching of Diverse Modes in a WGM Resonator; WGM Resonators for Terahertz-to-Optical Frequency Conversion; Determining Concentration of Nanoparticles from Ellipsometry; Microwave-to-Optical Conversion in WGM Resonators; Four-Pass Coupler for Laser-Diode-Pumped Solid-State Laser; Low-Resolution Raman-Spectroscopy Combustion Thermometry; Temperature Sensors Based on WGM Optical Resonators; Varying the Divergence of Multiple Parallel Laser Beams; Efficient Algorithm for Rectangular Spiral Search; Algorithm-Based Fault Tolerance Integrated with Replication; Targeting and Localization for Mars Rover Operations; Terrain-Adaptive Navigation Architecture; Self-Adjusting Hash Tables for Embedded Flight Applications; Schema for Spacecraft-Command Dictionary; Combined GMSK Communications and PN Ranging; System-Level Integration of Mass Memory; Network-Attached Solid-State Recorder Architecture; Method of Cross-Linking Aerogels Using a One-Pot Reaction Scheme; An Efficient Reachability Analysis Algorithm.

Source record↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

A three-layer magnetic shielding for the MAIUS-1 mission on a sounding rocket

Bose-Einstein-Condensates (BECs) can be used as a very sensitive tool for experiments on fundamental questions in physics like testing the equivalence principle using matter wave interferometry. Since the sensitivity of these experiments in ground-based environments is limited by the available free fall time, the QUANTUS project started to perform BEC interferometry experiments in micro-gravity. After successful campaigns in the drop tower, the next step is a space-borne experiment. The MAIUS-mission will be an atom-optical experiment that will show the feasibility of experiments with ultra-cold quantum gases in microgravity in a sounding rocket. The experiment will create a BEC of 10{sup 5} {sup 87}Rb-atoms in less than 5 s and will demonstrate application of basic atom interferometer techniques over a flight time of 6 min. The hardware is specifically designed to match the requirements of a sounding rocket mission. Special attention is thereby spent on the appropriate magnetic shielding from varying magnetic fields during the rocket flight, since the experiment procedures are very sensitive to external magnetic fields. A three-layer magnetic shielding provides a high shielding effectiveness factor of at least 1000 for an undisturbed operation of the experiment. The design of this magnetic shielding, the magnetic properties, simulations, and tests of its suitability for a sounding rocket flight are presented in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microdynamic Behavior of a Joint Dominated Structure On-Orbit

The interferometry program experiments (IPEX) I and II are the first free-flying space experiments specifically designed to characterize the sub-micron microdynamic behavior of large flexible optical structures subjected to on-orbit thermal-mechanical disturbances.

flight↗

On-Orbit Microdynamic Behavior of a Flexible Structure: IPEX II

The Interferometry Program EXperiments (IPEX) I and II are the first free-flying space experiments specifically designed to characterize the sub-micron microdynamic behavior of large flexible optical structures subjected to on-orbit thermal-mechanical disturbances.

Microdynamic↗

High data rate atom interferometric device

A light-pulse atomic interferometry (LPAI) apparatus is provided. The LPAI apparatus comprises a vessel, two sets of magnetic coils configured to magnetically confine an atomic vapor in two respective magneto-optical traps (MOTs) within the vessel when activated, and an optical system configured to irradiate the atomic vapor within the vessel with laser radiation that, when suitably tuned, can launch atoms previously confined in each of the MOTs toward the other MOT. In embodiments, the magnetic coils are configured to produce a magnetic field that is non-zero at the midpoint between the traps. In embodiments, the time-of-flight of the launched atoms from one MOT to the other is 12 ms or less. In embodiments, the MOTs are situated approximately 36 mm apart. In embodiments, the apparatus is configured to activate the magnetic coils according to a particular temporal magnetic field gradient profile.

47 OTHER INSTRUMENTATION↗

Squeezing Noise in Microscopy with Quantum Light

Quantum-enhanced microscopes capable of probing classically inaccessible material properties have drawn increasing interest, but most proof-of-principle quantum microscopes have not surpassed classical limits. Here, we discuss the promise and obstacles associated with the use of quantum light with reduced noise (‘squeezed’ light) for quantum-enhanced atomic force microscopy, bioimaging, magneto-optical measurements, and Raman spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental study on thermal characteristics of positive leader discharges using Mach-Zehnder interferometry

Leader discharge is one of the main phases in long air gap breakdown, which is characterized by high temperature and high conductivity. It is of great importance to determine thermal characteristics of leader discharges. In this paper, a long-optical-path Mach-Zehnder interferometer was set up to measure the thermal parameters (thermal diameter, gas density, and gas temperature) of positive leader discharges in atmospheric air. IEC standard positive switching impulse voltages were applied to a near-one-meter point-plane air gap. Filamentary channels with high gas temperature and low density corresponding to leader discharges were observed as significant distortions in the interference fringe images. Typical diameters of the entire heated channel range from 1.5 mm to 3.5 mm with an average expansion velocity of 6.7 m/s. In contrast, typical diameters of the intensely heated region with a sharp gas density reduction range from 0.4 mm to 1.1 mm, about one third of the entire heated channel. The radial distribution of the gas density is calculated from the fringe displacements by performing an Abel inverse transform. The typical calculated gas density reduction in the center of a propagating leader channel is 80% to 90%, corresponding to a gas temperature of 1500 K to 3000 K based on the ideal gas law. Leaders tend to terminate if the central temperature is below 1500 K.