Overview of Laser Damage Performance of the Third-Harmonic Frequency Conversion Crystals on the National Ignition Facility
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Fiber-based Raman spectroscopy enhances the Raman signal by maximizing the overlap of the optical field and the gas species. However, filling the hollow-core fiber (HCF) with gas requires time that is dependent on the fiber core diameter, fiber length, and pressure of the gas. At ambient pressure, the fiber gas uptake is driven by diffusion into the fiber ends, severely limiting the response time of the system. By laser drilling access holes to the core along the length of the fiber, the uptake time of the gas is reduced, improving the system response time. In this work, we study the carbon dioxide (CO 2 ) sensor dynamics based on Raman signal intensity generated in HCFs. The signal intensity versus gas concentration is characterized by controlling the CO 2 concentration in the surrounding environment of the fiber. Next, we characterize the gas uptake time in HCFs as a function of fiber length. Finally, we optimize the access hole configuration along the fiber, demonstrating reduced sensor uptake time by a factor of three.
Recently, an interferometric profilometer based on the heterodyning of three Gaussian beams has been reported. This microscope interferometer, called a three Gaussian beam interferometer, has been used to profile high quality optical surfaces that exhibit constant reflectivity with high vertical resolution and lateral resolution near {lambda}. We report the use of this interferometer to measure the profiles of two commercially available optical surfaces for data storage, namely, the compact disk (CD-R) and the digital versatile disk (DVD-R). We include experimental results from a one-dimensional radial scan of these devices without data marks. The measurements are taken by placing the devices with the polycarbonate surface facing the probe beam of the interferometer. This microscope interferometer is unique when compared with other optical measuring instruments because it uses narrowband detection, filters out undesirable noisy signals, and because the amplitude of the output voltage signal is basically proportional to the local vertical height of the surface under test, thus detecting with high sensitivity. We show that the resulting profiles, measured with this interferometer across the polycarbonate layer, provide valuable information about the track profiles, making this interferometer a suitable tool for quality control of surface storage devices.
The subsurface mechanical damage (SSD) depth after grinding fused silica glass with a comprehensive set of sub-aperture fixed abrasive grinding tools [cup, wheel, belt, pad, and rotary face mill (with and without ultrasonics)] and process parameters has been statistically measured using the taper wedge technique and evaluated. Consistent with a previously reported grinding model [J. Non-Cryst. Solids 352, 5601–5617 (2006) Crossref , Materials Science and Technology of Optical Fabrication (Wiley & Sons, 2018)], based on the sliding indentation fracture by sliding particles or asperities where the normal load per particle determines the depth of the fracture (and ultimately the overall SSD depth), the dominant factor controlling SSD depth was found to be the abrasive size regardless of the tool type and process conditions. Compared to full aperture grinding methods, the overall SSD depth was higher using the sub-aperture tools, likely due to the higher effective pressure and higher load per particle distribution. Here, in addition to abrasive size, a significant reduction in SSD depth was achieved by: (1) reducing the load distribution on the abrasive particles via increase in contact area and/or decrease in mechanical loading; (2) using a more compliant host tool medium; and (3) in what we believe is a more novel way, using ultrasonics. Combining low abrasive size, larger contact area, and a compliant host, the 6 µm diamond in a resin matrix (Trizact) on a foam pad led to very low SSD depth (~ 4.6 µm), relatively fast grinding rate (186 mm 3 /h), and little or no figure degradation. This grinding tool/process is an attractive choice for final grind, resulting in significantly reduced polish out (i.e., “grey out”) times. With the rotary face mill tool, the use of ultrasonics consistently led to a SSD depth reduction (ranging from 17%–34%). A new fracture mechanics-based model, to the best of our knowledge, where the relevant normal load is parallel to the feed direction, has been developed to explain how ultrasonics leads to lower SSD depth. The key factors, supported by finite element stress analysis and load measurements, are (1) the initiation of fractures at higher z heights during the tool’s ultrasonic vertical oscillations, thus propagating less deep into workpiece; (2) reduction in load (and therefore reduction in fracture propagation distance) due to smaller tool-workpiece feed direction contact area (again caused by higher heights relative to depth of cut); (3) upward movement of the tool during oscillation leads to fracturing toward the surface instead into the depth; and finally (4) at tool’s lowest point of oscillation cycle, there may not be enough time for the fracture to propagate to its full length.
Nanosecond dual-wavelength laser-induced damage was investigated at 1064 nm (1ω) and 355 nm (3ω) on ion-beam-sputtered hafnia single-layer coatings. Single-wavelength 1-on-1 tests were first conducted to establish reference onset fluences. Dual-wavelength tests combined a primary beam with variable fluence at one wavelength and a background, secondary wavelength beam with fixed fluences set to several percentages of the corresponding onset fluence. When 1ω was used as the background irradiation, the perceived damage resistance at 3ω decreased gradually. Here, in contrast, 3ω background irradiation at as little as 10% of the onset fluence led to an ≈ 50% abrupt reduction in the perceived 1ω damage resistance, followed by modest changes upon further increases in 3ω background fluences. Scanning electron microscopy and conversion ratios indicate that 3ω light is the primary driver of damage onset in the case of dual wavelength irradiation. A two-step precursor generation and activation model reproduces the 3ω behavior (1ω as background), but not the strong initial 1ω reduction (3ω as background), suggesting additional 3ω-induced precursors that saturate at low fluence.
We have utilized entangled photon pair coincidences to measure the fluorescence lifetime of the organic dye Rhodamine 6G, allowing lifetime measurements to be conducted at low intensities with a CW laser and without ultrafast pulsed lasers.
Reflective metal-lined capillary waveguides are useful for laser-power delivery or for collecting scattered light in sensing applications. We theoretically examine the multimode propagation of polarized light in large-diameter, metallized, capillary waveguides using a new perturbation technique valid for all waveguide modes. This modeling permits prediction of the collection efficiency of Raman or fluorescent light produced in the waveguide at all angles. These theoretical results are supported by measuring the intensity and angular distribution of collected scattered gas–Raman Stokes power.