Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear science & technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Fission TPC cross section ratio results [Abstract]

The fission TPC was designed for precision fission cross section ratio measurements. The high-fidelity 3D particle tracking data is used to conduct a detailed analysis of the uncertainty contributions. In this contribution a brief overview of the instrument was presented. The results of the 238 U(n,f)/ 235 U(n,f) cross section ratio measurement published in [Phys. Rev C 97, 034618 (2018)] were reviewed and the preliminary status of the 239 Pu(n,f)/ 235 U(n,f) cross section ratio measurement was shown.

238U(n,f)/235U(n,f) cross section ratio↗

IER 498: Godiva-IV CAAS benchmark [Slides]

This presentation discusses the benchmark of the IER 498: Godiva-IV criticality accident alarm system (CAAS). It details the goal of the project which is to create a CAAS benchmark capability for Godiva-IV in order to create a shielding benchmark for NCSP software and data, to add geometrically diverse benchmark/benchmarks to the ICSBEP Handbook, to enable more precise measurements at NCERC, and to help assure CAAS performance is as-stated. It also states that work was completed on CED-1 in 2019 and that future work includes the completion of CED-2 in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volume 4: Detection Systems and Ultra-Cold Neutrons

As part of the Sustaining and Enhancing Nuclear Science (SENSe) initiative at Oak Ridge National Laboratory (ORNL), the prospect of adding new detection systems to support High Flux Isotope Reactor (HFIR) operations and to advance scientific research has prompted many ideas and discussions regarding potential features, configurations, locations, and applications. A working group of ORNL staff members was organized to further develop the concepts and recommending one or more configurations to best support future HFIR operations and scientific capacities and to provide order-of-magnitude cost estimates and timing. The areas of investigation included fast access detection systems, non-scattering beamline instruments, shielded detection instruments, and an ultracold neutron source. In each case, the focus was to develop world leading capabilities that would be unmatched by any other facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Intensity Gamma Ray Source Scintillation Attenuation Spectrometer and Filter Stack Monoenergetic Calibration

The Laser-Based X-ray Radiographic Imaging team at Los Alamos National Lab is looking for a monoenergetic MeV X-ray source to both verify our Monte Carlo N-particle simulations of detector performance and calibrate the instruments for future measurements. Funded by the Laboratory Directed Research and Development (LDRD) program, our overall goal is to improve the radiographic quality and reliability of laser-based X-ray sources for deployment at both dynamic and static radiography facilities. Laser-based X-ray sources have demonstrated smaller spot sizes to current electron accelerator based sources. The smaller laser spot size leads to significantly improved resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of 149 Sm Capture and Total Cross Sections for Burnup Credit Applications [Slides]

This presentation highlights how capture and transmission measurements were performed with the DANCE (Detector for Advanced Neutron Capture Experiments) instrument with capture data from 8 eV – 1 keV, and DICER (Device for Indirect Capture Experiments on Radionuclides) instruments with transmission data from 1meV – 1 keV. There were additional measurements of 147 Sm which had contaminant in the samples, 3.4 eV strong resonance, interesting abnormalities. The data analysis is complete and the R-Matrix analysis almost (90%) complete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R-Matrix Analysis of the Neutron-Induced Cross Sections on 143 Nd and 147,149 Sm Measured at LANSCE [Slides]

This presentation covers how an established used of R-Matrix codes is being implemented at LANSCE. This presentation displays how there are unique features accessible with detectors at LANSCE that can be used to perform more complete R-Matrix analysis. Additionally discussed is how spin separation is a powerful technique that can be applied in DANCE measurements. Unique method to measure transmission with DICER are discussed. Finally, transmission and capture data are being analyzed in this work. The study can be extended to other channels. The ongoing analysis of the 143 Nd data is presented in this work. The same method is being applied to analyze the 147,149 Sm data. The 143 Nd and 147,149 Sm work started in FY-23 funded by NCSP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Mobility – Mass Spectrometry Rapid Imaging of Special Nuclear Materials

Robot Nose will use new fast data throughput methods and experience with laser microfocus to dramatically improve the speed and spatial resolution of an established instrument, making it a useful tool for imaging special nuclear materials (SNM). Mass spectrometry imaging instruments have traditionally been too slow and mass alone is generally an insufficient measurement for organic analyses. This situation was markedly improved by Ionwerks Inc., who pioneered the combination of ion mobility with mass spectrometry imaging. In 2D mobility-mass plots, clearly identifiable trend lines can be selected and reduced to 1D mass spectra without isobaric interferences. This is a major advantage over other imaging mass spectrometers that generally cannot distinguish isobars without custom-built lasers or high voltage accelerators. Special nuclear material (SNM) contains substantial fissile isotopes, particularly 233U, 235U, and 239Pu. A complete forensic analysis of SNM therefore requires quantitative isotopic measurement – often through some form of mass spectrometry. SNM contaminated with inclusions such as pollen grains can help identify its prior locations. The project team is presently working on an approach to allow rapid screening of 1-3 cm diameter thin samples of such material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating and Expanding DRiFT’s Helium-3 Detector Response Capabilities [Slides]

Helium-3 tubes are an efficient way to detect neutrons after they have thermalized by polyethylene. They are often arranged in rings to perform coincidence counting. Applications include nuclear safeguards, treaty verification, and emergency response. DRiFT has the ability to simulate pile-up, room return, and end effects. A new feature determines real and accidental correlated counts. The next steps include DRiFT 2.0 released as executable, continued demonstration of gas module capabilities, and semiconductor module under a development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Vela Hotel Program: The AEC's Space-Based Nuclear Detection and Treaty Verification Program [Slides]

Early Interest in "Detection": "I would suggest that the best way to get reliable information in a short time would be to send from the States a man qualified to do the testing of the samples on the spot. This man should be officially a representative of the State Department, and his detecting devices, such as small portable Geiger Counters, could then go into Switzerland in the diplomatic pouch via air from Southern Italy. This man could then contact, through the Embassy, suitable people who could collect the water samples without arousing too much curiosity. A fishing trip in a boat would probably give the best disguise, as the fisherman could carry a water bottle in his lunch basket, and fill it after drinking the original contents. The water should be collected from the center of the river, to get the swiftest flowing water, so that the holdup could be minimized. In the lake, the water should be collected as near to the suspected site as possible, or as near to each of the inlet rivers as can be done. Speed in getting from the collection point to the counting room is of great importance, as you are, no doubt, aware." - Luis Alvarez to Major Furman, May 1944.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detectors and diagnostics for multiprobe radiography using high-energy short-pulse lasers

Multiprobe radiography requires the following diagnostic capabilities at minimum: radiographic source diagnostics, spectroscopy, imaging, and tomography diagnostics. Depending on the repetition rate of the radiation sources, the diagnostics may be a single-shot diagnostic, such as photographic (radiochromic and X-ray films for high energy photons) films, or a multiple-shot diagnostic for repetitive source operations, such as a high-speed framing camera. Due to the drastically different detector physics of electrons, photons at different energies (keV to 10s of MeV in the radiography context), heavy ions such as protons, alphas, and neutrons, see, for example, Ref. [1, 2] for an overview, different types or configurations of detectors and constructions may be required for multiprobe radiography applications. Some of the common detector metricsinclude, independent of the particle/photon species, sensitivities or efficiency, energy resolution, spatial or temporal resolutions and others. Some unique detection scenarios arise in a multiprobe radiography setting, for example, crosstalk mitigation and particle identification (ID) when X-ray and higher energy photons, relativistic electrons, neutrons, other hadrons, and heavy particles coexist at the detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Transmission Measurements Capability at VISION Spectrometer [Slides]

This presentation covers the development of transmission measurements capability at VISION Spectrometer. Main takeaways include that INS and transmission measurements are and should be the most significant part of TSL validation, as they are the fundamental quantities used by Monte Carlo neutronics codes. Additionally, the development of transmission capability at VISION instrument has commenced. Promising first results have been obtained with a big impact by the use of the collimators. Finally, Areas of improvement have been identified and new measurements are planned for June.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗