Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

QCD equation of state at finite chemical potentials for relativistic nuclear collisions

In this work, we review the equation of state of QCD matter at finite densities. We discuss the construction of the equation of state with net baryon number, electric charge, and strangeness using the results of lattice QCD simulations and hadron resonance gas models. Its application to the hydrodynamic analyses of relativistic nuclear collisions suggests that the interplay of multiple conserved charges is important in the quantitative understanding of the dense nuclear matter created at lower beam energies. Several different models of the QCD equation of state are discussed for comparison.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Record of Decision: H - LEBT Design Modifications

The LAMP Conceptual Design (LCD) is described in the LAMP Conceptual Design Report. The proposed new configuration of the LAMP H - LEBT encompasses multiple changes to the LCD. The new configuration makes use of a single H - source to supply beam to all LANSCE user stations except IPF; this eliminates one of the H - sources in the LCD, and the associated pulsed merger magnet the use of two such sources required. The source current from the sole H - source is gated on a macropulse-by-macropulse basis using techniques demonstrated at SNS (Spallation Neutron Source), specifically, changes to the RF plasma drive power. A pulsed electrode system is used to match the beam into the LEBT transport line, variable on a macropulse-by-macropulse basis to match the source beam current.

43 PARTICLE ACCELERATORS↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Propeller modulation effects on a scanning-beam microwave landing system

The results of a systems study and ground test of the effects of propeller modulation on a time-multiplexed, scanning-beam microwave landing system (MLS) are presented. Propeller modulation effects are analyzed in terms of spacing between receiving antenna and propeller, propeller blade width, and propeller speed. Principal study conclusions: (1) scanning beam MLS is susceptible to errors due to synchronous propeller modulation; (2) the number of synchronous interference multiples increases as the number of propeller blades increases and as the data rate decreases; (3) the probability of synchronous interference decreases at higher data rates; and (4) MLS receiver susceptibility to propeller modulation depends upon the dynamic response of the receiver automatic gain control and the respective tracking loops.

Pope, J. M.↗

Achromatical Optical Correlator

Signal-to-noise ratio exceeds that of monochromatic correlator. Achromatical optical correlator uses multiple-pinhole diffraction of dispersed white light to form superposed multiple correlations of input and reference images in output plane. Set of matched spatial filters made by multiple-exposure holographic process, each exposure using suitably-scaled input image and suitable angle of reference beam. Recording-aperture mask translated to appropriate horizontal position for each exposure. Noncoherent illumination suitable for applications involving recognition of color and determination of scale. When fully developed achromatical correlators will be useful for recognition of patterns; for example, in industrial inspection and search for selected features in aerial photographs.

Chao, Tien-Hsin↗

Theory and simulation of cometary shocks

In this paper, recent kinetic simulation studies of cometary bow shocks are reviewed. Cometary shocks are formed due to solar wind mass loading by water group cometary ions. This process is kinetic in nature and varies as a function of the angle between the solar wind flow velocity and the interplanetary magnetic field, as do the properties of cometary shocks. For perpendicular and parallel orientations, quasi-steady shocks with dissipation scales on the order of proton inertial length form. At oblique orientations, no steady shocks are formed; instead, the transition from supersonic to subsonic flow takes place through multiple shocklets (steepened magnetosonic waves) which are generated by the pickup ions via the resonant electromagnetic ion beam instability. This new, time dependent model of cometary bow shocks is further investigated using a large scale kinetic simulation and is compared to the observations at Comet Giacobini-Zinner.

Omidi, N.↗

A personal communications network using a Ka-band satellite

The feasibility of a personal communications network using portable terminals that can provide 4.8-kb/s voice communications to a hub station via a Ka-band geosynchronous satellite has been investigated. Tradeoffs are examined so that the combined system of hub and gateway earth stations, the satellite, and the personal terminals can provide a competitive service in terms of cost, availability, and quality. A baseline system that uses a spacecraft with approximately 140 spot beams to cover the contiguous US (CONUS) and 5-W power amplifiers in each beam is described. Satellite access in both the forward and return directions uses frequency-division multiple-access/code-division multiple-access (FDMA/CDMA) with a chip rate of 2.5 Mchip/s.

Palmer, Larry C.↗

Solar Pumped Solid State Lasers for Space Solar Power: Experimental Path

We outline an experimentally based strategy designed to lead to solar pumped solid state laser oscillators useful for space solar power. Our method involves solar pumping a novel solid state gain element specifically designed to provide efficient conversion of sunlight in space to coherent laser light. Kilowatt and higher average power is sought from each gain element. Multiple such modular gain elements can be used to accumulate total average power of interest for power beaming in space, e.g., 100 kilowatts and more. Where desirable the high average power can also be produced as a train of pulses having high peak power (e.g., greater than 10(exp 10 watts). The modular nature of the basic gain element supports an experimental strategy in which the core technology can be validated by experiments on a single gain element. We propose to do this experimental validation both in terrestrial locations and also on a smaller scale in space. We describe a terrestrial experiment that includes diagnostics and the option of locating the laser beam path in vacuum environment. We describe a space based experiment designed to be compatible with the Japanese Experimental Module (JEM) on the International Space Station (ISS). We anticipate the gain elements will be based on low temperature (approx. 100 degrees Kelvin) operation of high thermal conductivity (k approx. 100 W/cm-K) diamond and sapphire (k approx. 4 W/cm-K). The basic gain element will be formed by sequences of thin alternating layers of diamond and Ti:sapphire with special attention given to the material interfaces. We anticipate this strategy will lead to a particularly simple, robust, and easily maintained low mass modelocked multi-element laser oscillator useful for space solar power.

Fork, Richard L.↗

A Comparison of Model Calculation and Measurement of Absorbed Dose for Proton Irradiation

With the increase in the amount of time spent EVA that is necessary to complete the construction and subsequent maintenance of ISS, it will become increasingly important for ground support personnel to accurately characterize the radiation exposures incurred by EVA crewmembers. Since exposure measurements cannot be taken within the organs of interest, it is necessary to estimate these exposures by calculation. To validate the methods and tools used to develop these estimates, it is necessary to model experiments performed in a controlled environment. This work is such an effort. A human phantom was outfitted with detector equipment and then placed in American EMU and Orlan-M EVA space suits. The suited phantom was irradiated at the LLUPTF with proton beams of known energies. Absorbed dose measurements were made by the spaceflight operational dosimetrist from JSC at multiple sites in the skin, eye, brain, stomach, and small intestine locations in the phantom. These exposures are then modeled using the BRYNTRN radiation transport code developed at the NASA Langley Research Center, and the CAM (computerized anatomical male) human geometry model of Billings and Yucker. Comparisons of absorbed dose calculations with measurements show excellent agreement. This suggests that there is reason to be confident in the ability of both the transport code and the human body model to estimate proton exposure in ground-based laboratory experiments.

Zapp, N.↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Efficient ultrathin all-dielectric nonlinear optical device

An apparatus and method are provided for generating harmonic light from a pump beam that is impinged on a metasurface comprising a plurality of all-dielectric resonator bodies. A multiple quantum well structure formed in each resonator body includes asymmetric coupled quantum wells having intersubband transition frequencies that couple to Mie resonances of the resonator bodies.

Sarma, Raktim↗

Evaluation of HPK n + - p planar pixel sensors for the CMS Phase-2 upgrade

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of signal characteristics and charge sharing in AC-LGADs with laser and test beam measurements

AC-LGADs, also referred to as resistive silicon detectors, are a recent development of low-gain avalanche detectors (LGADs), based on a sensor design where the multiplication layer and n + contact are continuous, and only the metal layer is patterned. In AC-LGADs, the signal is capacitively coupled from the continuous, resistive n + layer over a dielectric to the metal electrodes. Therefore, the spatial resolution is not only influenced by the electrode pitch, but also the relative size of the metal electrodes. Signal propagation between the metallized areas and charge sharing between electrodes plays a larger role in these detectors than in conventional silicon sensors read out in DC mode. AC-LGADs from two manufacturers were studied in beam tests and with infrared laser scans. The impact of n + layer resistivity and metal electrode pitch on the charge sharing and achievable position resolution is shown. For strips with 100 μm pitch, a resolution of ¡ 5 μm can be reached. Additionally, the charge sharing between neighboring strips is investigated in more detail, indicating the induction of signal charge and subsequent re-sharing over the n + layer. Furthermore, an approach to identify signal sharing over large distances is presented.

47 OTHER INSTRUMENTATION↗

Forward and backward stimulated Raman scattering in multi-speckled beams: Density dependence and effects on cross-beam energy transfer

Particle-in-cell simulations of cross-beam energy transfer (CBET) between multi-speckled beams reveal a potentially prominent energy loss from forward stimulated Raman scattering (FSRS) in the amplified seed beam [Yin et al., Phys. Plasmas 26, 082708 (2019)]. In this work, an intensity scan is used to examine this energy loss in the CBET-amplified seed beam at intensities of a few times 1014 W/cm2. Electron tracers demonstrate both the trapping in the electron plasma waves that is sustained over multiple speckles and the subsequent acceleration to velocities well beyond the phase velocity. Motivated by expanding our understanding of this energy loss mechanism, we isolate the FSRS density dependence by using a 2×1014 W/cm2 pulse to scan densities between 0.06 ncr and 0.12 ncr; a spectral analysis characterizes the energy losses from scattering with the changing densities. At saturation, both greater beam attenuation is measured at the laser frequency and larger scattering FSRS angles are observed as density increases, along with a rapid transition to primarily backscatter SRS between 0.10 ncr and 0.12 ncr, earlier than predicted by linear theory. Density gradients are shown to effectively mitigate oblique FSRS and beam energy losses in the two lower density cases, whereas 0° forward scattering is primarily suppressed in the higher density cases. Finally returning to the two-beam CBET system of interest, the interplay and mitigation of the secondary instabilities at larger domain and beam spatial scales are discussed, here also examining backward stimulated Brillouin scattering.

Stark, D. J. (ORCID:0000000203642733)↗

Identification of Final-State Neutrons in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-loaded (Gd-loaded) water Cherenkov detector located on the Booster Neutrino beamline at Fermilab. ANNIE's primary physics objectives include measuring neutron multiplicity for neutrino-nucleus interactions and performing cross-section measurements of charge current quasi-elastic and neutral current quasi-elastic processes. These measurements aim to improve neutrino energy reconstruction and reduce uncertainties in current and future neutrino oscillation experiments. Additionally, ANNIE serves as a testbed for advanced technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-Based Liquid Scintillator, which enhance vertex resolution and enable detection below the Cherenkov threshold. By leveraging the high neutron capture cross section of Gd-loaded water, ANNIE is well positioned to observe final-state neutrons in beam-correlated neutrino interactions. To constrain the uncertainties in the neutron capture efficiency and time within the detector, we have conducted multiple calibration campaigns using an AmBe source. The AmBe source is deployed at different locations of the tank to map the neutron capture efficiency and determine the expected neutron capture time. Additionally, the AmBe calibration data are used to define the precise neutron clustering that will be useful for identifying neutron-like clusters from neutrino interaction. In this poster, we will present the current status of the AmBe neutron calibration program and the development of neutron cluster definition for the ANNIE Experiment.

Ajana, Dhavalkumar [Florida State U.]↗

Measurement of Neutron Multiplicity in Charged Current Neutrino Interactions on Oxygen

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located 100~meters downstream in the Booster Neutrino Beam (BNB) at the Fermi National Accelerator Laboratory (Fermilab). Its primary goals are to (1) measure the neutron yield from $\nu_\mu$ interactions as a function of momentum transfer $Q^2$ so that neutrino-nucleus interaction models can be better constrained, and (2) demonstrate the power of novel, fast-timing detectors with the first deployment of Large Area Picosecond PhotoDetectors (LAPPDs). Current knowledge of neutrino-nucleus interactions fall short in modeling the topologies of such interactions, leading to inaccurate reconstruction of event kinematics such as particle energy, direction, and vertex. As a consequence, the accuracy of cross section measurements is impacted, which is necessary for precise physics measurements. Neutrons are an indication of inelasticity and affect the determination of the energy of the parent neutrino. Quantifying the neutron yield is a step towards reducing the associated uncertainties, and thus improving our understanding of these complex interactions and benefiting the next generation of long-baseline neutrino experiments. ANNIE will make use of LAPPDs to measure neutron multiplicity of CC-0$\pi$ $\nu_\mu$ interactions on oxygen, making it the first experiment to deploy an array of these photodetectors. Because the LAPPD is a novel photodetection technology, much customization is required to integrate it into existing electronics. The first half of this thesis covers the significant progress made towards the first deployment of the LAPPD system. From its test stand at Fermilab, the LAPPD system was systematically tested and put together until deployment readiness was achieved. I present my contributions to the design, fabrication, and testing of the waterproof housing and cables, and the commissioning of the LVHV board that powers the LAPPD and its readout electronics. These efforts brought the LAPPD system significantly closer to deployment, and eventually first data. The second half of this thesis presents the vertex and energy reconstruction algorithms developed to analysis the beam data with PMT-only information. While much progress has been made towards the deployment of LAPPDs, with several in the detector tank, efforts to integrate the LAPPD datastream are in progress. Thus, I developed a ring edge detection technique using PMT data to fit the muon vertex and determine its energy. The analysis in this thesis finds average neutron yields of $\Bar{n}_{data} = 0.452 \pm 0.039 (\text{stat}) \pm 0.27 (\text{sys})$ for a selection of muon neutrino candidates in the fiducial volume of ANNIE and corrected with an averaged neutron detection efficiency. An equivalent analysis for simulated beam data results in an average neutron yield of $\Bar{n}_{MC} = 0.582 \pm 0.018 (\text{stat}) \pm 0.25 (\text{sys})$. Future work includes application of efficiency corrections at a positional level, quantification of all systematic uncertainties, and neutron multiplicity measurements with other event topologies.

43 PARTICLE ACCELERATORS↗

Hybrid Analytical Technique for Nonlinear Vibration Analysis of Thin-Walled Beams

A two-step hybrid analytical technique is presented for the nonlinear vibration analysis of thin-walled beams. The first step involves the generation of various-order perturbation functions using the Linstedt-Poincare perturbation technique. The second step consists of using the perturbation functions as coordinate (or approximation) functions and then computing both the amplitudes of these functions and the nonlinear frequency of vibration via a direct variational procedure. The analytical formulation is based on a form of the geometrically nonlinear beam theory with the effects of in-plane inertia, rotatory inertia, and transverse shear deformation included. The effectiveness of the proposed technique is demonstrated by means of a numerical example of thin-walled beam with a doubly symmetric I-section. The solutions obtained using a single-spatial mode were compared with those obtained using multiple-spatial modes. The standard of comparison was taken to be the frequencies obtained by the direct integration/fast Fourier transform (FFT) technique. The nonlinear frequencies obtained by the hybrid technique were shown to converge to the corresponding ones obtained by the direct integration/fast Fourier transform (FFT) technique well beyond the range of applicability of the perturbation technique. The frequencies and total strain energy of the beam were overestimated by using a single-spatial mode.

Noor, Ahmed K.↗

Coaxial charged particle energy analyzer

A non-dispersive electrostatic energy analyzer for electrons and other charged particles having a generally coaxial structure of a sequentially arranged sections of an electrostatic lens to focus the beam through an iris and preferably including an ellipsoidally shaped input grid for collimating a wide acceptance beam from a charged-particle source, an electrostatic high-pass filter including a planar exit grid, and an electrostatic low-pass filter. The low-pass filter is configured to reflect low-energy particles back towards a charged particle detector located within the low-pass filter. Each section comprises multiple tubular or conical electrodes arranged about the central axis. The voltages on the lens are scanned to place a selected energy band of the accepted beam at a selected energy at the iris. Voltages on the high-pass and low-pass filters remain substantially fixed during the scan.

Kelly, Michael A.↗