Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “moderator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Monitoring and modeling hydrologic conditions in Ukraine for hydropower generation

Study region: The Dnieper and Dniester Rivers of Ukraine. Study focus: The ongoing conflict in Ukraine has caused disruptions to electricity generation, of which hydroelectric sources contribute approximately 9 % to the country’s needs. With the takeover of the Zaporizhzhia nuclear power plant by enemy forces, the loss of the Kakhovka hydroelectric dam, and the future impacts of the conflict on electricity generation unclear, it may be valuable for the Ukrainian government to better understand how it could leverage hydroelectric power sources in the near future. Unfortunately, measurements of river discharge throughout Ukraine ceased data collection in the late 1980’s to early 1990’s. To address this data gap, we developed a protocol that combined satellite-based time-series measurements of river width at seven locations throughout Ukraine from 2013 to 2023 with reanalysis data, climate-model predictions, and hydrologic models to both provide a means of monitoring a proxy for near-real-time discharge and also predict near-term (i.e., 2023–2030) hydrologic patterns for the region. New hydrological insights for the region: We ran new algorithms on 144 WorldView-2 and WorldView-3 satellite images to map rivers and extract width, one of which was validated against river gauge data located along the same river but in a neighboring country. Hydrologic models using two climate scenarios found minimal change in annual discharge at all sites, but magnitude and timing of peak discharge showed a moderate trend. The results suggest that hydropower is underutilized in Ukraine.

13 HYDRO ENERGY↗

Effect of pinholes in Nb 4 C 3 MXene sheets on its electrochemical behavior in aqueous electrolytes

Two-dimensional (2D) niobium carbide, Nb 4 C 3 T x (T x : O, OH, and F), a representative member of the 43 MXene structural motif, has shown promising electrochemical performance in acidic electrolytes. The capacitive performance of Nb 4 C 3 T x in neutral aqueous electrolytes has been reported as moderate, but little effort has been made to improve it. In this paper, we report a method to introduce nanopores (pinholes) in Nb 4 C 3 T x MXene flakes by adjusting the etching time. The pinholes generated during the etching process improve ion diffusion pathways, which are otherwise hindered by the restacking of the 2D flakes. The “holey Nb 4 C 3 T x ” shows a 50 % improved rate capability at charge/discharge time scales of 1–2 s in 1 M Li 2 SO 4 , Na 2 SO 4 , and (NH 4 ) 2 SO 4 electrolytes. Our strategy of controlling the permeability of Nb 4 C 3 T x sheets can potentially be applied to other MXenes, providing guidance for improving the capacitance and rate capability of 2D materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uniform secondary current distribution at disk electrodes under Tafel kinetics enabled by concentric current-shielding rings

Non-uniform secondary current distribution at rotating disk electrodes (RDE) is a common problem when using resistive electrolyte media or large applied currents. In a recent publication, we have shown that auxiliary electrodes such as the ring of a rotating ring disk electrode (RRDE) can help suppress current non-uniformities at the disk enabling reliable electroanalytical measurements. However, this previous work considered linear kinetics where current distribution non-uniformities were moderate. In the present contribution, we consider current distribution non-uniformities encountered under Tafel kinetics. We show, for the case of 2,5-dihydroxy-1,4-benzoquinone (DHBQ) reduction, that optimally chosen ring conditions serve to provide effective shielding at the disk edge rendering the overall disk current distribution to be uniform. Numerical modeling and scaling analysis (using the Wagner number) are presented to aid a user in determining the optimal ring current density for achieving uniform disk current distribution under Tafel kinetics. This approach is especially useful when studying soluble-soluble redox transitions for which, unlike deposit distribution in electrodeposition, the current distribution non-uniformity is not visually apparent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of nonmetallic ion substitution in perovskite LaCoO 3 for improved oxygen evolution reaction activity

Transition metal perovskite (ABO 3 ) is an emerging type of oxygen evolution reaction (OER) electrocatalyst that shows reasonably good activity and moderate stability. Although efforts have been made to improve perovskite’ OER performance by various element substitution at A/B-site, the influence of ion, particularly non-metallic ion, substitutions on the OER mechanism are rarely studied. More and more evidence has shown that the metal-center theory has failed to explain lots of OER-related phenomena. Therefore, it is urgent to understand how the cation and anion sites in perovskite determine OER performance. In this work, we used a Fe and P co-doped LaCoO 3 as a model system to explore the influence of substitution in perovskite by combining operando/ex-situ X-ray characterization and density functional theory (DFT). We observed enhanced OER catalytic activities in co-doped materials, which are attributed to the stronger transition-metal-oxygen-bonding-covalency (TMOBC). The detailed analyses by O K-edge XAS, electrochemical performance, and DFT suggest that the hybridization between O 2p and transition metal 3d e g orbitals could be a more credible descriptor of perovskite for OER, which is the combination of e g orbital theory and TMOBC theory. The finding in our work provides insights into the OER catalysis mechanism on metal oxides, which could guide new design of cost-effective oxide electrocatalysts.

25 ENERGY STORAGE↗

Bridging interfacial properties and cell performance: A multiscale model for proton-exchange-membrane fuel cells

Here, to elucidate the impact of local interfaces on mass-transport resistance and overall cell performance of low-loaded proton-exchange-membrane fuel cells (PEMFCs), we present a multiscale modeling framework incorporating a novel modified agglomerate model. The model considers three distinct Pt-electrolyte interfaces: Pt on the carbon surface covered by either ionomer or water film and Pt inside carbon nanopores. Detailed mass-transport voltage-loss breakdowns reveal that coupled agglomerate-interface-scale mass transport dominates the mass-transport loss. The ionomer poisons the exterior-Pt surface through suppressing O 2 adsorption and intrinsic ORR activity, leading to low current-density performance. Conversely, interior-Pt interface enhances the kinetic performance but limits high current-density performance due to its low interfacial permeability. The exterior-Pt/water interface demonstrates superior kinetic performance and mass transport, though its practical implementation requires ensuring proton transport. By coupling the multiscale CL properties with ink parameters, the model identifies an optimal I to C ratio of approximately 0.5, a moderate value where the ionomer content is sufficient to guarantee proton transport without fully covering the Pt surface and forming large agglomeration, thus allowing the utilization of the Pt-water interface and avoiding high mass-transport loss. Overall, the model helps unravel limiting phenomena across different operating regimes and provides routes for optimizing performance.

Cell diagnostic↗

Preparation of a uranium monocarbide anode and electrochemical characterization in molten LiCl-KCl-UCl 3

Porous uranium carbide (UC) pellets possessing moderate electrical conductivity were synthesized by reaction of UO 2 with graphite at temperatures up to 1550°C under rough vacuum. Conversions as high as 98% were achieved at soak times of 2-4 hours. The electrochemistry of the UC pellets in molten LiCl-KCl-6.5 wt% UCl 3 was explored using a variety of techniques including DC polarization methods, cyclic voltammetry, chronopotentiometry and bulk electrolysis. Here, the electrode reaction for anodic dissolution was found to be kinetically controlled by dissociation of UC to a transition state complex that was hypothesized to consist of a uranium atom partially complexed by chloride ions. Precise measurements of current efficiencies using chronopotentiometry indicated upper limits of 90.9 ± 3.4% and 98.3 +1.7/-3.7% for anode and cathode, respectively, when operating at anodic overpotentials near +300 mV. Bulk electrolysis of a UC pellet performed by passing 98% of the theoretical charge resulted in nearly complete recovery of its uranium content as highly pure metal at the cathode.

36 MATERIALS SCIENCE↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Integration of cryogenic energy storage with renewables and power plants: Optimal strategies and cost analysis

Energy storage is critical for overcoming challenges associated with the intermittency and the variable availability of renewable sources for decarbonizing the energy sector. Cryogenic energy storage (CES) is of interest due to its high technology readiness level, no geographical limitations, and moderate round-trip efficiency. The time-varying nature of demands and renewable availability needs to be considered at the design and integration stages of energy storage. We develop a mixed-integer nonlinear program (MINLP) model to obtain the energy storage costs on a daily basis for different scenarios that typically arise over an entire year. Using this optimization-based framework, we address key decision-making questions towards energy transition: What is the energy cost when CES is integrated with renewables and power plants? How does each scenario affect the overall energy cost? How much storage is needed for complete transition to renewables? What is the optimal integration towards 100% renewable energy? What are the optimal storage designs for both renewables and fossil-based power generation with current and future energy demands? Here, we discuss different scenarios and solutions to these questions.

25 ENERGY STORAGE↗

Anomalously high elastic modulus of a poly(ethylene oxide)-based composite electrolyte

The practical use of lithium metal anodes in solid-state batteries requires a polymer membrane with high lithium-ion conductivity, thermal/electrochemical stability, and mechanical strength. The primary challenge is to effectively decouple the ionic conductivity and mechanical strength of the polymer electrolytes. We report a remarkably facile single step synthetic strategy based on in-situ crosslinking of poly(ethylene oxide) (xPEO) in the presence of a woven glass fiber (GF). Such a simple method yields composite polymer electrolytes (CPE) of anomalously high elastic modulus up to 2.5 GPa over a broad temperature range (20 °C – 245 °C) that has never been previously documented. An unsupervised machine learning algorithm, K-mean clustering analysis, was implemented on the hyperspectral Raman mapping at the xPEO/GF interface. Using such a unique means, we show for the first time that the promoted mechanical strength originates from xPEO and GF interactions through dynamic hydrogen and ionic bonding. High ionic conductivity is achieved by the addition plasticizer (e.g. tetraglyme), where trifluoromethanesulfonate anions are tethered to the xPEO matrix and Li + cations are favorably transported through coordination with the plasticizer. Further, stringent galvanostatic cycling tests indicates the CPE can be stably cycled for >3000 h in a Li-metal symmetric cell at a moderate temperature (nearly 1500 Coulombs/cm 2 Li equivalents), outperforming most of the PEO-based electrolytes. The GF reinforced CPE reported here has multifunctional uses, such as solid electrolytes for all solid-state batteries and membranes for redox-flow batteries. Although the focus of this study is on lithium-based batteries, the results are equally promising for other alkali metal based batteries such as sodium and potassium.

25 ENERGY STORAGE↗

Synergistic effects of chlorine substitution in sulfide electrolyte solid state batteries

All-solid-state battery is considered as one of the most promising competitors to Li ion batteries. Two widely known performance metrics for solid electrolytes, among others, are ionic conductivity and stability. In this study, it is found that both can be improved by the synergistic effects of chlorine substitution in sulfide-based solid electrolytes. Particularly, instabilities arising from both bulk decompositions and interfacial reactions to electrodes can be better inhibited in the chlorine substituted sulfide solid electrolytes through the increased susceptibility to the mechanical constriction induced enhancement of voltage stability. As a result, the stability window of some chlorine-rich Li-argyrodites can be systematically higher than some other chlorine-deficient or chlorine-free electrolytes, especially under the implementation of the mechanical constriction battery assembly and test conditions. Thus, a solid-state battery system of 4 V to 5 V-class cathodes paired with lithium metal anode is demonstrated using these chlorine-rich Li-argyrodites without additional coatings. Furthermore, since Cl composition modulates the stability and instability of Li-argyrodite at low voltages, it allows us to design a multilayer configuration with a hierarchy of Li metal stabilities to demonstrate the stable cycling at relatively high current densities for solid-state batteries. It is found that a moderate Cl composition in the electrolyte is the best to inhibit Li dendrite penetration as the central electrolyte layer, emphasizing a slightly increased “instability” as the hidden performance metric of relevance here, in addition to the two well-known metrics of stability and ionic conductivity. The understanding of the chlorine substitution effect in sulfide electrolytes provides an important design principle for all-solid-state batteries.

25 ENERGY STORAGE↗

Revisiting the initial irreversible capacity loss of LiNi 0.6 Co 0.2 Mn 0.2 O 2 cathode material batteries

Layered LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NCM622) attracts widespread attention primarily due to its potential for high energy density and moderate thermal stability. However, the low initial coulombic efficiency (ICE) of the material limits the maximum utilization of their capacity. The capacity loss in the first cycle occurs under 4.0V and keep almost constant are considered as common characteristics for NCM-based materials. A clear cognition on the initial capacity loss may light the way to improve the practical reversible capacity of NCM622 at 4.0V. Conducting operando X-ray diffraction during galvanostatic charge/discharge cycling at different temperature (25 degrees C, 45 degrees C and 60 degrees C) and different current (0.1C, 0.01C, 1C=120 mA g -1 ) in the voltage range of 2.7-4.0V, we find that only 8% of the measured initial irreversible capacity loss is associated with parasitic reactions that form cathode/electrolyte interface, and that the dominant contributors include the slow Li + diffusion kinetics (similar to 46% contribution) and irreversible O3/H1-3 phase transition (similar to 46% contribution). Finally, this semi-quantitative study provides new insight on initial capacity loss, guiding further targeted modification and fully utilization of NCM622.

25 ENERGY STORAGE↗

Species- and element-specific patterns of metal flux from contaminated wetlands versus metals shed with exuviae in emerging dragonflies

Dragonfly adults and their aquatic immature stages are important parts of food webs and provide a link between aquatic and terrestrial components. During emergence, contaminants can be exported into terrestrial food webs as immature adults fly away or be shed with their exuviae and remain in the wetland. Our previous work established metals accumulating in dragonfly nymphs throughout a contaminated constructed wetland designed to regulate pH and sequester trace metals from an industrial effluent line. In this paper we evaluated the concentration and mass of metals leaving the wetland in flying emergents versus remaining in the wetland with the shed exuviae in 10 species of dragonflies belonging to 8 genera. Nine elements (Cu, Zn, Cd, Mn, V, Mg, Fe, Al, Pb) were evaluated that include essential and nonessential elements as well as trace and major metals. Metal concentrations in the emergent body and exuviae can differ by orders of magnitude. Aluminum, Fe, Mn, and Pb were largely shed in the exuviae. Vanadium and Cd were more variable among species but also tended to be shed with the exuviae. In contrast, Cu, Zn, and Mg showed a higher tendency to leave the wetland with an emerging dragonfly. Metals shed in dragonfly exuviae can moderate the transport of metals from contaminated wetlands. Taxonomic- and metal-specific variability in daily metal flux from the wetland depended upon concentration accumulated, individual body mass, and number of individuals emerging, with each factor's relative importance often differing among species. This illustrates the importance of evaluating the mass of metals in an individual and not only concentrations. Furthermore, differences in numbers of each species emerging will magnify differences in individual metal flux when calculating community metal flux. A better understanding of the variability of metal accumulation in nymphs/larvae and metal shedding during metamorphosis among both metals and species is needed.

54 ENVIRONMENTAL SCIENCES↗

Incidence of chronic respiratory conditions among oil spill responders: Five years of follow-up in the Deepwater Horizon Oil Spill Coast Guard Cohort study

Background: Over ten years after the Deepwater Horizon (DWH) oil spill, our understanding of long term respiratory health risks associated with oil spill response exposures is limited. Here we conducted a prospective analysis in a cohort of U.S. Coast Guard personnel with universal military healthcare. Methods: For all active duty cohort members (N = 45,193) in the DWH Oil Spill Coast Guard Cohort Study we obtained medical encounter data from October 01, 2007 to September 30, 2015 (i.e., ~2.5 years pre-spill; ~5.5 years post-spill). We used Cox Proportional Hazards regressions to calculate adjusted hazard ratios (aHR), comparing risks for incident respiratory conditions/symptoms (2010–2015) for: responders vs. non-responders; responders reporting crude oil exposure, any inhalation of crude oil vapors, and being in the vicinity of burning crude oil versus responders without those exposures. We also evaluated self-reported crude oil and oil dispersant exposures, combined. Within-responder comparisons were adjusted for age, sex, and smoking. Results: While elevated aHRs for responder/non-responder comparisons were generally weak, within-responder comparisons showed stronger risks with exposure to crude oil. Notably, for responders reporting exposure to crude oil via inhalation, there were elevated risks for all sinusitis (aHR = 1.48; 95%CI, 1.06–2.06), unspecified chronic sinusitis (aHR = 1.55; 95%CI, 1.08–2.22), chronic obstructive pulmonary disease (COPD) and other allied conditions (aHR = 1.43; 95%CI, 1.00–2.06), and dyspnea and respiratory abnormalities (aHR = 1.29; 95%CI, 1.00–1.67); there was a suggestion of elevated risk for diseases classified as asthma and reactive airway diseases (aHR = 1.18; 95%CI, 0.98–1.41), including the specific condition, asthma (aHR = 1.35; 95%CI, 0.80–2.27), the symptom, shortness of breath (aHR = 1.50; 95%CI, 0.89–2.54), and the overall classification of chronic respiratory conditions (aHR = 1.18; 95%CI, 0.98–1.43). Exposure to both crude oil and dispersant was positively associated with elevated risk for shortness of breath (HR = 2.24; 95%CI, 1.09–4.64). Conclusions: Among active duty Coast Guard personnel, oil spill clean-up exposures were associated with moderately increased risk for longer term respiratory conditions.

54 ENVIRONMENTAL SCIENCES↗

Krypton storage capacity of the Earth's lower mantle

Noble gases are important geochemical tracers allowing reconstructing global volatile cycles in Earth's reservoirs. To constrain these fundamental processes, precise data on their partitioning behavior at deep Earth conditions are needed. Such data are only available at moderate pressures up to 25 GPa due to experimental challenges. We have investigated the possibility of noble gas storage in the Earth's lower mantle up to 115 GPa. We studied the incorporation of krypton in the second most abundant lower mantle mineral (Mg 1-x ,Fe x )O (ferropericlase) as well as in liquid metal-alloys by performing experiments up to 115 GPa and 3700 K using the laser-heated diamond anvil cell coupled to post-mortem EMPA analysis and X-ray absorption spectroscopy. The results reveal that, at these extreme conditions, up to 3 wt.% of krypton can be stored in (Mg 1-x ,Fe x )O and 3000 ppm in the Fe-rich liquid metal. For both phases the storage capacities increase with pressure (between 40 GPa and 60 GPa) at a constant high temperature of 2300 K. Fpc has never been considered as a NG host, despite being the second most abundant mineral in the Earth's LM. Using recent accurate compressibility data, we demonstrate that a substitution of krypton into the anion site of (Mg 1-x ,Fe x )O in form of neutral oxygen Schottky defects at diluted lower mantle conditions is possible. This noble gas incorporation mechanism is in agreement with a previous study on bridgmanite. We show that (Mg 1-x ,Fe x )O exhibits higher noble gas storage capacities than bridgmanite through the lower mantle using lattice strain modeling and including experimental solubility and thermoelastic data for neon, argon, krypton and xenon. We also demonstrate that both phases exhibit the highest solubilities for argon and krypton. We used the solubility data from lattice strain modeling to predict noble gas abundances stored in the solid lower mantle after magma ocean crystallization. The modeled abundances show apparent similarities with estimates for the deep noble gas reservoir that are based on either 3He abundances in ocean island basalts or radiogenic 40Ar abundances in the bulk Earth. This strongly indicates that the crystalline lower mantle may play an important role as deep noble gas storage reservoir. We propose, based on considerations on noble gas replenishment from the lower mantle to the atmosphere, that the lower mantle can only contribute to a small fraction of the present-day atmospheric noble gases. This suggests that the lower mantle is an un-degassed reservoir.

58 GEOSCIENCES↗

Gallium isotopic constraints for the origin of the Earth-Moon system

Comparatively heavy isotopic compositions of moderately volatile elements (MVE) in lunar rocks have been advocated to reflect the loss of light isotopes during devolatilization processes from the Moon. In this study we present new gallium (Ga) isotope data for lunar highland rocks, with a focus on the Ferroan Anorthosite Suite (FAS). These are commonly thought to be direct crystallization products from the late lunar magma ocean (LMO) and should contain the majority of the Ga inventory of the Moon. As such, FAS rocks are crucial for identifying the processes that drove Ga isotope fractionation as well as for inferring the Ga isotopic composition of the bulk Moon. Our data reveal that FAS samples have a range in δ 71 Ga from -0.27 to 0.22‰ and are generally isotopically light in Ga compared to other lunar lithologies, but straddle values typical of terrestrial rocks. Although Ga is defined as an MVE, these Ga isotope variations do not correspond with concentrations of more volatile elements, indicating that Ga isotope variations in the FAS are not primarily controlled by devolatilization processes. Instead, the Ga isotopic compositions of bulk FAS rocks broadly correlate with the composition of plagioclase, with the calcium content of plagioclase decreasing as Ga becomes isotopically heavier. This suggests that fractionation of Ga isotopes in FAS rocks was caused by the preferential incorporation of isotopically light Ga into plagioclase during the later solidification stages of the LMO. The progressive crystallization and extraction of plagioclase forces the residual melt towards increasingly heavier Ga isotope ratios, corroborating similar conclusions derived from correlations between δ 71 and Eu* in the mare basalt suite. Using Ga isotope partitioning calculations, we demonstrate that an isotope fractionation coefficient between plagioclase and coexisting melt of -0.3 to -0.4‰ could explain the observed range of δ 71 values in FAS, mare basalt suite rocks, and KREEP. These calculations allow for a first order estimate of the Ga isotopic composition of the bulk silicate Moon prior to plagioclase fractionation and suggest it was close to the composition of the bulk silicate Earth. This would imply that the Moon did not lose a substantial fraction of its Ga inventory during accretion, consistent with new constraints from Rb-Sr isotope systematics that indicate the Moon's volatile deficit was primarily inherited from Theia. In conjunction with the overlap in non-mass-dependent isotope ratios, these collective observations could be reconciled if Theia and the proto-Earth formed in similar regions of the inner Solar System that were already volatile-depleted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The geographies, typologies, and trends of community-based organizations for solar energy in the United States

Community-based organizations (CBOs)1 play an important role in developing solar energy in low- and moderate-income (LMI) communities. This article shares the perspectives of CBO leaders in LMI communities, identifies and addresses solar information gaps, and provides recommendations State Energy Agencies and other government leaders can use to better involve CBOs in solar program initiatives. Using semi-structured interviews and focus groups with CBOs from across the United States (US) we develop typologies of CBO structure and function, and determine the primary motivations, challenges, opportunities, and communication barriers CBOs face. We explore the correlation between key typologies such as tenure, staff capacity, population served, organizational structure, and region with the organizational activities performed by solar-related CBOs. CBOs operate in disparate regional political and economic ecologies. Our findings suggest strategies for states to support their engagement in solar-related endeavors, particularly with respect to the dissemination of the Bipartisan Infrastructure Law, Inflation Reduction Act, and the EPA Greenhouse Gas Reduction Fund: Solar for All. Developing policies that encourage CBOs to enter the solar training and installation domains, alongside targeted grants and capacity-building initiatives can help maximize community benefits. Furthermore, states can additionally contribute to the positive trajectory and collaboration between state agencies and CBOs in advancing solar energy adoption by fostering a supportive environment.

14 SOLAR ENERGY↗