Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Performance of three-dimensional printed nasopharyngeal swabs for COVID-19 testing

At the start of the COVID-19 pandemic, the US faced nationwide shortages of nasopharyngeal swabs due to both overwhelmed supply chains and an increase in demand. To address this shortfall, multiple 3D printed swabs were ultimately produced and sold for COVID-19 testing. In this work, we present a framework for mechanical and functional bench-testing of nasopharyngeal swabs using standard and widely available material testing equipment. Using this framework, we offer a comprehensive, quantitative comparison of the 3D printed swabs to benchmark their performance against traditional flocked swabs. The test protocols were designed to emulate the clinical use of the nasopharyngeal swabs and to evaluate potential failure modes. Overall, the 3D printed swabs performed comparably to, or outperformed, the traditional swabs in all mechanical tests. While traditional swabs outperformed some of the new 3D printed swabs in terms of sample uptake and retention, similar amounts of RNA were recovered from both 3D printed and traditional swabs.

3D printing↗

LTE-P-14 Non PGM Conductivity measurement

A procedure for measuring the electrical conductivity of PGM-free OER catalyst powders to allow comparison of one material to another. This standard two-point conductivity protocol is applicable to transition metal oxides, mixed oxides, perovskites, spinels, etc.

08 HYDROGEN↗

NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

Tenth Interim Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton ® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 °F. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 °F.

42 ENGINEERING↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (Tenth Interim Status Report)

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT Oring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 84 - 108 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 5 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF, and in one GLT-S O-ring fixture aging at 300 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 250 ºF for 66 months. One O-ring fixture has failed since the last interim report was issued. Both O-rings in one GLTS fixture aging at 300 ºF failed to remain leak-tight after 69 months at temperature. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures has been performed in the last year to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

Eleventh interim status report: Model 9975 O-Ring fixture long-term leak performance

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF.

42 ENGINEERING↗

FY2017 status report: Model 9975 O-ring fixture long-term leak performance

A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. Leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The 300 °F GLT O-ring fixtures failed after 2.8 to 5.7 years at temperature. The remaining GLT O-ring fixtures aging at 300 ºF were retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 9 to 10.5 years, or in GLT O-ring fixtures aging at 270 ºF for 5.7 years. These aging temperatures bound O-ring temperatures anticipated during normal storage in K-Area Complex (KAC). Leak test failures have been experienced in all of the GLT-S O-ring fixtures aging at 300 ºF and above. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 ºF for 6.9 to 7.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty still exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

42 ENGINEERING↗

FY2018 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression stress-relaxation (CSR) tests and field surveillance are also on going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Criticality Accidents in Experiments and Reactors [Slides]

The objectives of this presentation are to: (1) gain awareness of the historical timelines and trends associated with the occurrences of critical experiment accidents associated, (2) identify lessons learned from accidents with critical experiments and the development of standards for handling nuclear material and performance of critical experiments; and (3) to ensure trainees gain a working knowledge of the factors that lead to the accidents.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Understanding Geometry and Microstructure Interactions In LPBF By Linking Lab Scale Studies To Real Part Case Examples

The mechanical properties derived from simple tensile tests are uniquely important in the design and qualification of load bearing metallic components. The tensile properties in standards for wrought metallic materials are generally accessible for design and simulation engineers, but this is not the case for additively manufactured metals. This work investigates the influence of tensile specimen geometry on the mechanical properties of laser powder bed fusion (LPBF) additively manufactured Ti-6Al-4V, particularly in relation to properties measured from specimens excised from an exemplar part. A comprehensive analysis was conducted across various specimen geometries, considering factors such as thermal history, cross-sectional area, shape, and surface roughness. Key findings reveal that sample size, particularly cross-sectional area, significantly affects reported tensile properties, with ASTM E8 flat and round specimens exhibiting differences in elastic modulus (13%), yield strength (17%), ultimate tensile strength (UTS) (14%), and elongation to failure (11%). Additionally, surface roughness was found to have a limited impact on ASTM round geometries, but it becomes critical in thin-walled and small high-throughput samples. The ASTM flat samples closely matched the properties of samples excised from the exemplar part, underscoring the necessity of testing witness samples that accurately represent end-use conditions. Furthermore, mechanical properties of samples built within the stitch zone of the exemplar part demonstrated reduced ductility, highlighting the importance of laser alignment and qualification in multi-laser additive manufacturing processes. Overall, this study emphasizes the need for careful consideration of specimen geometry and testing conditions to ensure accurate reporting of mechanical properties in LPBF Ti-6Al-4V.

36 MATERIALS SCIENCE↗

Solar Radiation Research Laboratory (SRRL) Core Project Final Report: Fiscal Years 2022-2024

The Solar Radiation Research Laboratory (SRRL) at the National Laboratory of the Rockies (NLR) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m2) for the United States that is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two calibration facilities that meet International Standards Organization-17025 (ISO-17025) standards and provide unique high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System (BMS) at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop (1) improved methods for the calibration of solar radiometers; (2) new standards through the ISO, the International Electrotechnical Commission (IEC), and the American Standards for Testing of Materials (ASTM) International; (c) solar radiation and meteorological models; and (d) advanced instrumentation and methods for operating solar measurement stations. The SRRL datasets are also critical for the validation of new models and datasets, such as the National Solar Radiation Database (NSRDB). The research and development of solar radiation measurement systems and resource modeling techniques are essential for advancing the scientific basis for producing reliable resource data. Specifically, the spatial, temporal, and spectral (wavelength dependency) characteristics of the solar resource are required in several different time frames for various project phases.

14 SOLAR ENERGY↗

Analysis Report for Hydrolyzed UF 6 Samples

Under the auspices of the US Department of Energy/National Nuclear Security Agency’s Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory was tasked with analyzing two UF6 filled hoke tubes for uranium isotopic composition. This report documents the results of the measurements performed by the MSIS group’s International Organization for Standardization/International Electrotechnical Commission 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry, and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ORNL Report for Hydrolyzed UF 6 Samples 439451, 438792, 439144, 439616, and 439617

Under the auspices of the US Department of Energy/National Nuclear Security Agency’s Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory was tasked with analyzing five UF 6 filled P-10 tubes for uranium isotopic composition. This report documents the results of the measurements performed by the MSIS group’s International Organization for Standardization/International Electrotechnical Commission 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry, and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ORNL Report of Analysis for the Verification of NRMP CRM U030A

In support of the Certified Reference Material (CRM) program managed by the Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory (ORNL) was asked to prepare a set of CRM U030A units for use as standards for isotopic analysis using multicollector thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) instruments. This report documents the results of the verification measurements performed on three randomly selected units by the MSIS group’s ISO/IEC 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry [1], and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan [2].

Mathew, Kattathu [Oak Ridge National Laboratory (O↗

Modeling Solids in Nuclear Astrophysics with Smoothed Particle Hydrodynamics

Abstract Smoothed particle hydrodynamics (SPH) is a frequently applied tool in computational astrophysics to solve the fluid dynamics equations governing the systems under study. For some problems, for example when involving asteroids and asteroid impacts, the additional inclusion of material strength is necessary in order to accurately describe the dynamics. In compact stars, that is white dwarfs and neutron stars, solid components are also present. Neutron stars have a solid crust, which is the strongest material known in nature. However, their dynamical evolution, when modeled via SPH or other computational fluid dynamics codes, is usually described as a purely fluid dynamics problem. Here, we present the first 3D simulations of neutron star crustal toroidal oscillations including material strength with the Los Alamos National Laboratory SPH code FleCSPH. In the first half of the paper, we present the numerical implementation of solid material modeling together with standard tests. The second half is on the simulation of crustal oscillations in the fundamental toroidal mode. Here, we dedicate a large fraction of the paper to approaches that can suppress numerical noise in the solid. If not minimized, the latter can dominate the crustal motion in the simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Separator for alkaline batteries

Separator compositions have been tested as components of three-plate silver-zinc oxide cells in a standard cycling test. Six materials meet imposed requirements, giving cycling performance superior to cellophane.

Hoyt, H. W.↗

Development of materials screening tests for oxygen-enriched environments

The criteria governing materials to be used in an oxygen enriched atmosphere and tests to determine suitability for fireproof considerations in spacecraft design are discussed. The nine tests applied to materials before acceptance in spacecraft construction are presented. The application of the standard tests to determine ranking of materials is included.

Johnston, R. L.↗

Surface roughness effects on bidirectional reflectance.

An experimental study of surface roughness effects on bidirectional reflectance of metallic surfaces is presented. Samples consisting of glass, aluminum alloy, and stainless steel materials were roughened using standard grinding techniques and coated with a radiatively opaque layer of pure aluminum. Surface roughness parameters, rms height and rms slope, were evaluated from digitized surface profile measurements and are less than 1.0 micron, and 0.28, respectively. Rough-surface specular, bidirectional, and directional reflectance measurements for selected values of polar angle and wavelength of incident energy within the range from 10 to 80 deg and from 1 to 14 microns, respectively, are reported. The influence of surface roughness is discussed in terms of rms height and rms slope.

Smith, T. F.↗