Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Microchip and wedge ion funnels and planar ion beam analyzers using same

Electrodynamic ion funnels confine, guide, or focus ions in gases using the Dehmelt potential of oscillatory electric field. New funnel designs operating at or close to atmospheric gas pressure are described. Effective ion focusing at such pressures is enabled by fields of extreme amplitude and frequency, allowed in microscopic gaps that have much higher electrical breakdown thresholds in any gas than the macroscopic gaps of present funnels. The new microscopic-gap funnels are useful for interfacing atmospheric-pressure ionization sources to mass spectrometry (MS) and ion mobility separation (IMS) stages including differential IMS or FAIMS, as well as IMS and MS stages in various configurations. In particular, "wedge" funnels comprising two planar surfaces positioned at an angle and wedge funnel traps derived therefrom can compress ion beams in one dimension, producing narrow belt-shaped beams and laterally elongated cuboid packets. This beam profile reduces the ion density and thus space-charge effects, mitigating the adverse impact thereof on the resolving power, measurement accuracy, and dynamic range of MS and IMS analyzers, while a greater overlap with coplanar light or particle beams can benefit spectroscopic methods.

47 OTHER INSTRUMENTATION↗

Extraction Simulations and Emittance Measurements of a Holifield Radioactive Ion Beam Facility Electron Beam Plasma Source for Radioactive Ion Beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

Liu, Yuan↗

Ion Production and Transport in Atmospheric Pressure Ion Source Mass Spectrometers (Final Report)

This document is the final report on a project that focused in the general theme of atmospheric-pressure ion production and transport for mass spectrometry. Within that general theme there were two main projects: the fundamental study of the transport of elemental ions through the vacuum interface of an inductively coupled plasma mass spectrometer (ICPMS), and fundamental studies of the ionization mechanisms in ambient desorption/ionization (ADI) sources for molecular mass spectrometry. In both cases the goal was to generate fundamental understanding of key instrumental processes that would lead to the development of instruments that were more sensitive and more consistent in their performance. The emphasis on consistency derives from the need for instruments that have the same sensitivity, regardless of sample type. In the jargon of analytical chemistry, such instruments are said to be free from matrix effects. In the ICPMS work each stage of ion production and of ion transport from the atmospheric pressure to the high-vacuum mass analyzer was studied. Factors controlling ion transport efficiency and consistency were identified at each stage of pressure reduction. In the ADI work the interactions between an electrospray plume and a fluorescent sample on a surface were examined microscopically. A new mechanism for analyte ion production in desorption electrospray ionization (DESI) was proposed. Optical spectroscopy was used to track the production of reactive species in plasmas used as ADI sources. Experiments with mixed-gas plasmas demonstrated that the addition of a small amount of hydrogen to a helium ADI plasma could boost the sensitivity for some analytes by over an order of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Beam Dynamics Studies of a Multi-Ion Linac Injector for the JLEIC Ion Complex

The electron-ion collider (JLEIC) being proposed at JLab requires a new ion accelerator complex which includes a linac capable of delivering any ion beam from hydrogen to lead to the booster. We are currently developing a linac which consists of several ion sources, a normal conducting (NC) front end, up to 5 MeV/u, and a SC section for energies > 5 MeV/u. This design work is focused on the beam dynamics and electrodynamics studies performed to design efficient and cost-effective accelerating structures for both the NC and SC sections of the linac. Currently, we are considering two separate RFQs for the heavy-ion and light-ion beams including polarized beams, and different types of NC accelerating structures downstream of the RFQ. Quarter-wave and half-wave resonators can be effectively used in the SC section.

Ostroumov, P. N.↗

Anode for sodium-ion and potassium-ion batteries

A first method for fabricating an anode for use in sodium-ion and potassium-ion batteries includes mixing a conductive carbon material having a low surface area, a hard carbon material, and a binder material. A carbon-composite material is thus formed and coated on a conductive substrate. A second method for fabricating an anode for use in sodium-ion and potassium-ion batteries mixes a metal-containing material, a hard carbon material, and binder material. A carbon-composite material is thus formed and coated on a conductive substrate. A third method for fabricating an anode for use in sodium-ion and potassium-ion batteries provides a hard carbon material having a pyrolyzed polymer coating that is mixed with a binder material to form a carbon-composite material, which is coated on a conductive substrate. Descriptions of the anodes and batteries formed by the above-described methods are also provided.

25 ENERGY STORAGE↗

Electrically regenerated ion-exchange technology: Leveraging faradaic reactions and assessing the effect of co-ion sorption

Capacitive deionization (CDI) technologies have the potential to become cost-competitive alternatives to reverse osmosis for the treatment of brackish waters. In this study, we describe our findings on the effect of co-ion sorption and faradaic side reactions on our ion exchange resin functionalized desalination electrodes which passively capture salt and reject it upon charging. This system, which we previously reported on and refer to as electrically regenerated ion exchange (ERI), avoids the use of expensive ion exchange membranes in an effort to save costs. Surprisingly, we find that, compared to a reference CDI system, ERI electrodes capture salt most effectively at low applied voltages (0.5 mg/cm 3 at 0.8 V). Both CDI and ERI systems also seem to suffer from co-ion sorption effects which negatively impact salt adsorption. However, Faradaic side reactions at higher voltages (1 V and 1.2 V) which we track via pH measurements, serve as a detriment to CDI but seem to facilitate the functionality of ERI.

42 ENGINEERING↗

The structural influence of aluminium ions on emission characteristics of Sm{sup 3+} ions in lead aluminium silicate glass system

Graphical abstract: The optical absorption and photoluminescence spectra of Sm ions in PbO-Al{sub 2}O{sub 3}-SiO{sub 2} glasses mixed with different concentrations of Al{sub 2}O{sub 3} have been investigated. From these spectra, the emission probabilities and also fluorescence lifetime principal transition viz., {sup 4}G{sub 5/2} {yields} {sup 6}H{sub 7/2} of Sm{sup 3+} ions of has been evaluated. The analysis of results of these studies has indicated that there is a less radiative trapping and enhanced fluorescence lifetime and high quantum efficiency in the glasses mixed with 8.0 mol% of Al{sub 2}O{sub 3}. Highlights: Black-Right-Pointing-Pointer Glasses of the composition (40 - x)PbO-(5 + x)Al{sub 2}O{sub 3}-54SiO{sub 2}:1.0Sm{sub 2}O{sub 3} with x = 5-10 mol% were prepared. Black-Right-Pointing-Pointer Spectroscopic properties (OA, PL and IR) were investigated. Black-Right-Pointing-Pointer Emission probability, lifetime, branching ratio of {sup 4}G{sub 5/2} {yields} {sup 6}H{sub 7/2} transition of Sm{sup 3+} have been evaluated. Black-Right-Pointing-Pointer Analysis of the results indicated that glass mixed with 8.0 mol% exhibits high luminescence efficiency. -- Abstract: Optical absorption and photoluminescence characteristics of Sm{sup 3+} ions in lead silicate glasses mixed with different concentrations of Al{sub 2}O{sub 3} (5-10 mol%) have been investigated. From these studies, the radiative properties viz., spontaneous emission probability A, the total emission probability, the radiative lifetime {tau}{sub R}, the fluorescent branching ratio {beta} of emission transition of {sup 4}G{sub 5/2} {yields} {sup 6}H{sub 7/2} along with other transitions for Sm{sup 3+} have been evaluated and found to be the highest for the glass mixed with 8.0 mol% of Al{sub 2}O{sub 3}.The IR spectral studies have indicated that Al{sup 3+} ions do participate in the glass network with AlO{sub 4} and AlO{sub 6} structural units and further revealed that the concentration of octahedral aluminium ions induce bonding defects in the glass network. Such bonding defects are assumed to be responsible for low phonon losses in these glasses and lead to higher values of radiative parameters for the glass mixed with 8.0 mol% of Al{sub 2}O{sub 3}.

36 MATERIALS SCIENCE↗

Laser ion source for heavy ion inertial fusion

The proposed heavy ion inertial fusion (HIF) scenarios require ampere class low charge state ion beams of heavy species. A laser ion source (LIS) is recognized as one of the promising candidates of ion beam providers, since it can deliver high brightness heavy ion beams to accelerators. A design of LIS for the HIF depends on the accelerator structure and accelerator complex following the source. In this article, we discuss the specifications and design of an appropriate LIS assuming two major types of the accelerators: radio frequency (RF) high quality factor cavity type and non-resonant induction core type. We believe that a properly designed LIS satisfies the requirements of both types, however some issues need to be verified experimentally.

43 PARTICLE ACCELERATORS↗

High-Capacity Aqueous Storage in Vanadate Cathodes Promoted by the Zn-Ion and Proton Intercalation and Conversion–Intercalation of Vanadyl Ions

Aqueous Zn-ion batteries (AZIBs) are promising alternatives to lithium-ion batteries in stationary storage. However, limited storage capacity and cyclic life impede their large-scale implementation. In this study, we report reversible electrochemical insertion of multi-ions into sodium vanadate (NaV 3 O 8 ) cathode materials for AZIBs, achieving a maximum storage capacity of 450 mAh g –1 at 0.05 A g –1 and a capacity retention of 82% after 500 cycles at 0.4 A g –1 . In addition to Zn 2+ and H + insertion, in situ X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) collectively provide explicit evidence on vanadyl ions (VO 2+ ) conversion–intercalation at the NaV 3 O 8 cathode, showing the deintercalation of VO 2+ from NaV 3 O 8 and the consequent conversion of VO 2+ into V 2 O 5 on charging, and vice versa on discharging. Our study is the first to report on the cation conversion–intercalation mechanism in AZIBs. This reversible multi-ion storage mechanism provides a design principle for developing high-capacity aqueous electrode materials by engaging both the intercalation and conversion of charge carriers.

25 ENERGY STORAGE↗

Structure of Hydronium (H3O+)/Chloride (Cl-) Contact Ion Pairs in Aqueous Hydrochloric Acid Solution: A Zundel-like Local Configuration

Details of the H3O+ and H2O structure in the first solvation shell about Cl- in aqueous HCl solutions are reported from x-ray absorption fine structure (XAFS) measurements. Results show increasing degrees of contact ion pairing between Cl- and H3O+ as the HCl concentration increases from 6.0 m, 10.0 m and finally 16.1 m HCl (concentrated acid). At the highest acid concentration there are on average, approximately 1.6 H3O+ ions and 4.2 H2O’s in the first shell about Cl-. The structure of the Cl-/H3O+ contact ion pair is distinctly different than that of the H2O structure about Cl-. The Cl-O bond length (2.98Å) for Cl-/H3O+ is approximately 0.16 Å shorter than the Cl-/H2O bond. The bridging proton resides at an intermediate position between Cl and O at 1.60 Å from the Cl- and approximately 1.37 Å from the O of the H3O+. The bridging-proton structure of this contact ion pair, [Cl-H-OH2], is similar to structure of the water Zundel ion, [H2O-H-OH2]+. In both cases there is a shortened Cl-O or O-O bond and the intervening proton bond distances are substantially longer than for the covalent bonds of either HCl or H2O. The results further our understanding of the interaction H3O+ with Cl- that is of interest to fundamental physical chemistry and that has consequences in biochemical, geochemical and atmospheric processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic time-warping correction for shifts in ultrahigh resolving power ion mobility spectrometry and structures for lossless ion manipulations

Detection of arrival time shifts between ion mobility spectrometry (IMS) separations can limit achievable resolving power (Rp), particularly when multiple separations are summed or averaged, as commonly practiced. Such variations are more apparent in higher Rp measurements, and are particularly evident in long path length traveling wave structures for lossless ion manipulations (SLIM) IMS due to their typically much longer separation times. Here we explore the utility of a data processing approaches employing linear alignment (LA) and nonlinear dynamic time warping (DTW) of IMS separations to correct for variations between separations, such as due to pressure fluctuations. For multipass SLIM IMS separations, where narrow mobility range measurements have arrival times that can extend to several seconds, the LA approach effectively corrected for such variations, and significantly improvement Rp for summed separations. However, LA was much less effective for high Rp broad mobility range separations, such as obtained with multilevel SLIM IMS. Changes in IMS arrival times ions were observed to be correlated with small pressure changes, with approximately 0.6% relative arrival time shifts being common, sufficient to result in a loss of Rp for summed separations. Comparison of the approaches showed DTW alignment performed similarly to LA when used over a narrow mobility range, but was significantly better (providing narrower peaks and higher signal intensities) for wide mobility range data. We found the DTW approach increased Rp by as much as 115% for measurements in which 50 IMS separations over 2 seconds were summed, and leading to a large improvement in effective Rp. We conclude that DTW is superior to LA for ultrahigh resolution broad mobility range SLIM IMS separations, correcting for ion arrival time shifts regardless of the cause. Our tool is publicly available for use with universal ion mobility format (.UIMF) and text (.txt) files.

Data alignment, dynamic time warping, ion mobility↗

Ion thermal effects in oscillating multi-ion plasma sheath theory

The effects of the ion temperature are discussed in a two-ion electron plasma and for a model applicable to the oscillating sheath theory that has recently been much of the focus in research. The differences between the fluid and kinetic models are pointed out, as well as the differences between the approximative kinetic description (which involves the expansion of the plasma dispersion function), and the exact kinetic description. It is shown that the approximative kinetic description, first, cannot describe the additional acoustic mode which naturally exists in the plasma with an additional ion population with a finite temperature, and, second, it yields an inaccurate Landau damping of the bulk ion acoustic mode. The reasons for these two failures of the model are described. In addition to this, a fluid model is presented that is capable of capturing both of these features that are missing in the approximative kinetic description, i.e., two (fast and slow) ion acoustic modes, and the corresponding Landau damping of both modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The advanced ion-milling method for preparation of thin film using ion slicer: Application to a sample recovered from diamond-anvil cell

The advanced argon ion-milling technique using a new instrument called ion slicer was newly developed for preparation of thin foil. Compared to the conventional ion-milling methods, this technique facilitates very wide area to be homogeneously thinned by rocking the ion beam source with low angle and the specimen during milling. Here we applied this technique to a sample recovered from a laser-heated diamond-anvil cell (DAC). We obtained the thin film of almost entire cross section of the DAC sample along the compression axis, which possesses of {approx}(10x50) {mu}m{sup 2}. The laser-heated sample is often heterogeneous due to a large temperature gradient. However the chemical analyses are obtained from the whole hot spot under the transmission electron microscope by preparing the thin foil using the ion slicer.

36 MATERIALS SCIENCE↗

Ion acoustic waves in pair-ion plasma: Linear and nonlinear analyses

Linear and nonlinear properties of low frequency ion acoustic wave (IAW) in pair-ion plasma in the presence of electrons are investigated. The dispersion relation and Kadomtsev-Petviashvili equation for linear/nonlinear IAW are derived from sets of hydrodynamic equations where the ion pairs are inertial while electrons are Boltzmannian. The dispersion curves for various concentrations of electrons are discussed and compared with experimental results. The predicted linear IAW propagates at the same frequencies as those of the experimentally observed IAW if n{sub e0}{approx}10{sup 4} cm{sup -3}. It is found that nonlinear profile of the ion acoustic solitary waves is significantly affected by the percentage ratio of electron number density and temperature. It is also determined that rarefactive solitary waves can propagate in this system. It is hoped that the results presented in this study would be helpful in understanding the salient features of the finite amplitude localized ion acoustic solitary pulses in a laboratory fullerene plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact electron ion coincidence analyzer using a coaxially symmetric mirror electron energy analyzer and a miniature polar-angle-resolved time-of-flight ion mass spectrometer with four concentric anodes

A compact electron ion coincidence (EICO) analyzer that uses a coaxially symmetric mirror electron energy analyzer and a miniature polar-angle-resolved time-of-flight ion mass spectrometer with four concentric anodes was developed for surface science and surface analysis. The apparatus is especially useful in the study of ion desorption stimulated by an Auger process because information on the mass, yield, desorption polar angle, and kinetic energy of ions can be obtained for the selected core-ionization-final-states or the selected Auger-final-states. The analyzer can be used also for analysis of the configuration of specific surface molecules because the desorption polar angles reflect the direction of surface bonds. The EICO analyzer was evaluated by measuring polar-angle-resolved-ion yield spectra and coincidence spectra of Auger-electron and polar-angle-resolved H{sup +} from condensed water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A self-sputtering ion source: A new approach to quiescent metal ion beams

A new metal ion source is presented based on sustained self-sputtering plasma in a magnetron discharge. Metals exhibiting high self-sputtering yield such as Cu, Ag, Zn, and Bi can be used in a high-power impulse magnetron sputtering discharge such that the plasma almost exclusively contains singly charged metal ions of the target material. The plasma and extracted ion beam are quiescent. The ion beams consist mostly of singly charged ions with a space-charge limited current density which reached about 10 mA/cm{sup 2} at an extraction voltage of 45 kV and a first gap spacing of 12 mm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma ion dynamics and beam formation in electron cyclotron resonance ion sources

In electron cyclotron resonance ion sources it has been demonstrated that plasma heating may be improved by means of different microwave to plasma coupling mechanisms, including the ''frequency tuning'' and the ''two frequency heating''. These techniques affect evidently the electron dynamics, but the relationship with the ion dynamics has not been investigated in details up to now. Here we will try to outline these relations: through the study of ion dynamics we may try to understand how to optimize the electron cyclotron resonance ion sources brightness. A simple model of the ion confinement and beam formation will be presented, based on particle-in-cell and single particle simulations.

43 PARTICLE ACCELERATORS↗

Ion distribution measurements to probe target and plasma processes in electronegative magnetron discharges. I. Negative ions

Mass and energy spectra of negative ions in magnetron sputtering discharges have been investigated with an energy-dispersive mass spectrometer. The dc magnetrons have been operated in the same reactive Ar/O{sub 2} atmosphere but with three different target materials: Cu, In, and W. Besides negative ions of the working gas, a variety of target metal containing negative molecular ions were found in the discharge. Their occurrence is strongly dependent on the target material. It has been correlated to the electron affinity and the bond strength of the molecules which has been calculated by density functional theory. Energy spectra of the negative ions exhibit three contributions that are clearly distinguishable. Their different origin is discussed as electron attachment in the gas phase and at the target surface, and molecule fragmentation during transport from target to substrate. The latter two contributions again significantly deviate for different target material. The high-energy part of the spectra has been analyzed with respect to the energy the particles gain upon release from the surface. It suggests that bigger molecules formed on the surface are released by ion-assisted desorption.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗