Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Atomic layer deposition of TiN for the fabrication of nanomechanical resonators

Films of titanium nitride were grown by atomic layer deposition (ALD) over a range of temperatures from 120 Degree-Sign C to 300 Degree-Sign C, and their deposition rates were characterized by ellipsometry and reflectometry. The stress state of the films was evaluated by interferometry using a wafer bowing technique and varied from compressive (-18 MPa) to tensile (650 MPa). The crystal structure of the films was assessed by x-ray diffraction. The grain size varied with temperature in the range of 2-9 nm. The chemical composition of the films was ascertained by high-resolution x-ray photoelectron spectroscopy and showed the presence of O, Cl, and C contaminants. A mildly tensile (250 MPa) stressed film was employed for the fabrication (by electron beam lithography and reactive ion etching) of doubly clamped nanoresonator beams. The resonance frequency of resonators was assayed using an interferometric resonance testing apparatus. The devices exhibited sharp mechanical resonance peaks in the 17-25 MHz range. The uniformity and controllable deposition rate of ALD films make them ideal candidate materials for the fabrication of ultranarrow (<50 nm) nanobeam structures.

36 MATERIALS SCIENCE↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three Dimensional Speckle Imaging Employing a Frequency-Locked Tunable Diode Laser

We describe a high accuracy frequency stepping method for a tunable diode laser to improve a three dimensional (3D) imaging approach based upon interferometric speckle imaging. The approach, modeled after Takeda, exploits tuning an illumination laser in frequency as speckle interferograms of the object (specklegrams) are acquired at each frequency in a Michelson interferometer. The resulting 3D hypercube of specklegrams encode spatial information in the x-y plane of each image with laser tuning arrayed along its z-axis. We present laboratory data of before and after results showing enhanced 3D imaging resulting from precise laser frequency control.

hree dimensional imaging↗

EUV photolithography mask inspection using Fourier ptychography

Fourier ptychography is a computational imaging techniques that combines various full-field coherent images acquired under varied illumination angles and combined to yield a angular spectrum with a large synthetic numerical aperture and non-interferometric phase information. We present here the implementation of this technique in a full-field soft x-ray microscope designed to emulate modern EUV lithography tools imaging conditions, and we show that this technique can be used for the study of EUV photomasks. The technique allows us to quantitatively characterize phase defects (predominant in EUV lithography), to study new mask designs made of phase structures, to study sub-resolution assist features and extend the resolution of the microscope down to 26-nm, correspond to the N1 technology node.

Wojdyla, Antoine↗

Fixed-Angle Reflectance from Uranium Compounds and U-Bearing Minerals: Experimental Challenges to Determine the Optical Constants n and k

Fixed-angle reflectance spectroscopy using a commercial Fourier transform infrared (FTIR) spectrometer was employed to derive the optical constants n and k of several uranium compounds. This technique relies upon measurement of the quantitative reflectance R(?) spectra from a polished surface across a broad spectral range (in this case, the mid- and far-IR covering ca. 7500 to 50 cm-1) followed by application of the Kramers-Kronig transformation (KKT). Near-normal fixed-angle measurements as used in this technique require continuous reflectance spectra to as low a wavenumber value as possible. Here, we discuss some of the many challenges in measuring the far-IR and very far-IR (terahertz) spectra using an interferometric instrument, particularly those stemming from small sample sizes, typically just millimeters on a face for crystalline samples, as well as limitations due to optical components and diffraction. We apply this method to single-crystal UO2 and its mineralogical form uraninite, as well as other U-bearing minerals such as autunite [Ca(UO2)2(PO4)2·8-12H2O] and the dehydrated form of autunite, meta-autunite. In addition to the specular reflectance spectra, x-ray diffractometry was used as a confirmatory technique to analyze the surface composition of the species. Deriving the infrared optical constants for such U-bearing species (as well as other solids) will enable nondestructive detection under a variety of environmental and compositional conditions.

Uranium Minerals, infrared spectroscopy, optical c↗

Increasing Baselines and Precision of Optical Interferometers Using Two-Photon Interference

Observations using interferometers provide sensitivity to features of images on angular scales much smaller than any single telescope, on the order of Δθ ~ λ/b where b is the interferometric baseline. Present-day optical interferometers are essentially classical, interfering single photons with themselves. However, there is a new wave of interest in interferometry using multiple photons, whose mechanisms are inherently quantum mechanical, which offer the prospects of increased baselines and finer resolutions among other advantages. We will discuss recent ideas and results for quantum-assisted interferometry using the resource of entangled pairs, and specifically a two-photon amplitude technique aimed at improved precision in astrometry.

47 OTHER INSTRUMENTATION↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

Binary pseudo-random array (BPRA) for inspection and calibration for cylindrical wavefront interferometry

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. However, surface topography measurements are instrument dependent, and without the knowledge of how the instrument performs under the practical usage conditions, the measured data contain some degree of uncertainty. Binary Pseudo Random Array (BPRA) “white noise” artifact are effective and useful for characterizing the Instrument Transfer Function (ITF) of surface topography metrology tools and wavefront measurement instrument. BPRA artifact contains features with all spatial frequencies in the instrument bandpass with equal weight. As a result, power spectral density of the patterns has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range. The application examples include electron microscopes, x-ray microscopes, interferometric microscopes, and large field-of-view Fizeau Interferometers. Furthermore, we will introduce the application of BPRA method to characterizing the ITF of Cylindrical Wavefront Interferometry (CWI), by developing the BPRA artifact which matches the radius of curvature of the cylindrical wavefront. The data acquisition and analysis procedures for different applications of the ITF calibration technique developed are also discussed.

Munechika, K↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

SU-E-T-410: Fringe Stability and Phase Shift Measurements in a Michelson Interferometer for Optical Calorimetry

Purpose: To identify the variables limiting the resolution of a Michelson interferometer used to measure phase shifts (PS) in water as part of a radiometric calorimeter. Methods: We investigated the output stability of a He-Ne laser and a laser diode. The short and long term stability of the fringe pattern in a Michelson interferometer was tested with different types of lasers, thermal insulation arrangements, damping systems and optical mounts to optimize system performance. PS were induced by electrically heating water in a 1 cm quartz cuvette located in one of the interferometer arms. The PS was calculated from fringe intensity changes and compared to a calculated PS using thermocouple-measured temperature changes in the water. Results: The intensity of the laser diode is more stable, but the gas laser’s profile is more suitable for fringe analysis and has better temporal coherence. The laser requires a warm-up time of 4 hours before its output is stabilized (SNR>95). The fringe’s stability strongly depends on the thermal insulation. When the interferometer is exposed to ambient temperature swings of 0.7 K, it is not possible to stabilize the fringe pattern. Enclosing the system in a 2.5 cm-thick Styrofoam box improves the SNR, but further insulation will be needed to increase the SNR above 50. High frequency noise is significantly reduced by damping the system.Inducing a temperature rise in water, starting at 299 K, the average temperature increase for a 2π PS is 0.29 ± 0.02 K and the proportionality constant is -21.1 ± 0.8 radians/K. This is 5.8% lower than the calculated value using the thermocouple. Conclusion: Interferometric PS measurements of temperature may provide an alternative to thermistors for water calorimetry. The resolution of the current prototype is limited by ambient temperature stability. Calculated and measured thermally-induced PS in water agreed to within 5.8%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global climate change and local land subsidence exacerbate inundation risk to the San Francisco Bay Area

The current global projections of future sea level rise are the basis for developing inundation hazard maps. However, contributions from spatially variable coastal subsidence have generally not been considered in these projections. We use synthetic aperture radar interferometric measurements and global navigation satellite system data to show subsidence rates of less than 2 mm/year along most of the coastal areas along San Francisco Bay. However, rates exceed 10 mm/year in some areas underlain by compacting artificial landfill and Holocene mud deposits. The maps estimating 100-year inundation hazards solely based on the projection of sea level rise from various emission scenarios underestimate the area at risk of flooding by 3.7 to 90.9%, compared with revised maps that account for the contribution of local land subsidence. Given ongoing land subsidence, we project that an area of 125 to 429 km 2 will be vulnerable to inundation, as opposed to 51 to 413 km 2 considering sea level rise alone.

54 ENVIRONMENTAL SCIENCES↗

Attosecond photoionization delays in the vicinity of molecular Feshbach resonances

Temporal delays extracted from photoionization phases are currently determined with attosecond resolution by using interferometric methods. Such methods require special care when photoionization occurs near Feshbach resonances due to the interference between direct ionization and autoionization. Although theory can accurately handle these interferences in atoms, in molecules, it has to face an additional, so far insurmountable problem: Autoionization is slow, and nuclei move substantially while it happens, i.e., electronic and nuclear motions are coupled. Here, we present a theoretical framework to account for this effect and apply it to evaluate time-resolved and vibrationally resolved photoelectron spectra and photoionization phases of N 2 irradiated by a combination of an extreme ultraviolet (XUV) attosecond pulse train and an infrared pulse. We show that Feshbach resonances lead to unusual non–Franck-Condon vibrational progressions and to ionization phases that strongly vary with photoelectron energy irrespective of the vibrational state of the remaining molecular cation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Surface uplift and time-dependent seismic hazard due to fluid injection in eastern Texas

Observations that unequivocally link seismicity and wastewater injection are scarce. We show that wastewater injection in eastern Texas causes uplift, detectable in radar interferometric data up to >8 kilometers from the wells. Using measurements of uplift, reported injection data, and a poroelastic model, we computed the crustal strain and pore pressure. We infer that an increase of >1 megapascal in pore pressure in rocks with low compressibility triggers earthquakes, including the 4.8–moment magnitude event that occurred on 17 May 2012, the largest earthquake recorded in eastern Texas. Seismic activity increased even while injection rates declined, owing to diffusion of pore pressure from earlier periods with higher injection rates. Finally, induced seismicity potential is suppressed where tight confining formations prevent pore pressure from propagating into crystalline basement rocks.

58 GEOSCIENCES↗

Anisotropy of the electro-optic effect in magnesium-doped LiNbO{sub 3} crystals

Specific features of constructing indicatory surfaces of the electro-optic effect (EOE) are described. The generalized case for the symmetry class 3m and all three possible indicatory surfaces under orthogonal experimental conditions, when the directions of light propagation and electric field are orthogonal, is considered. The EOE surfaces are constructed for magnesium-doped lithium niobate crystals. The specific features of anisotropy of these surfaces are discussed and their extreme values and corresponding angular coordinates are found. To construct the indicatory surfaces, all absolute coefficients of the linear electro-optic effect are determined by the interferometric method. The difference in the electro-optic coefficients of pure and magnesiumdoped crystals does not exceed 10%. An advantage of doped crystals is their high durability to high-power laser radiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anode Plasma Formation at the Initial Stage of a Nanosecond Air Discharge

The initial stage of a nanosecond discharge in gaps with a high electric field at a cathode is studied by laser methods (interferometric, shadow, schlieren methods). The studies are performed in air at atmospheric pressure. Prominence is given to studying the evolution (appearance and growth) of the plasma channels at an anode and to estimating their parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of phase transitions on the kinetic parameters of polytetrafluoroethylene deformation

The effect of solid-state phase transitions on the kinetic parameters of creep deformation in polytetrafluoroethylene has been studied by differential scanning calorimetry and a laser-interferometric creep rate meter. It has been shown that the deformation activation volumes and the elementary phase transition volume differ from each other by more than an order of magnitude. The crystalline component of this polymer becomes a liquid-crystal phase coexisting with an amorphous phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗