Coupled Flow and Deformation Modeling of Carbon Dioxide Migration in the Presence of a Caprock Fracture during Injection

Understanding the transport of carbon dioxide (CO{sub 2}) during long-term CO{sub 2} injection into a typical geologic reservoir, such as a saline aquifer, could be complicated because of changes in geochemical, hydrogeological, and hydromechanical behavior. While the caprock layer overlying the target aquifer is intended to provide a tight, impermeable seal in securing injected CO{sub 2}, the presence of geologic uncertainties, such as a caprock fracture or fault, may provide a channel for CO{sub 2} leakage. There could also be a possibility of the activation of a new or existing dormant fault or fracture, which could act as a leakage pathway. Such a leakage event during CO{sub 2} injection may lead to a different pressure and ground response over a period of time. In the present study, multiphase fluid flow simulations in porous media coupled with geomechanics were used to investigate the overburden geologic response and plume behavior during CO{sub 2} injection in the presence of a hypothetical permeable fractured zone in a caprock, existing or activated. Both single-phase and multiphase fluid flow simulations were performed. The CO{sub 2} migration through an existing fractured zone leads to changes in the fluid pressure in the overburden geologic layers and could have a significant impact on ground deformation behavior. Results of the study show that pressure signatures and displacement patterns are significantly different in the presence of a fractured zone in the caprock layer. The variation in pressure and displacement signatures because of the presence of a fractured zone in the caprock at different locations may be useful in identifying the presence of a fault/fractured zone in the caprock. The pressure signatures can also serve as a mechanism to identify the activation of leakage pathways through the caprock during CO{sub 2} injection. Pressure response and ground deformation behavior from sequestration modeling could be useful in the development of smart technologies to monitor safe CO{sub 2} storage and understand CO{sub 2} transport, with limited field instrumentation.

54 ENVIRONMENTAL SCIENCES↗

Computation of Transverse Injection Into Supersonic Crossflow With Various Injector Orifice Geometries

Computational results are presented for the performance and flow behavior of various injector geometries employed in transverse injection into a non-reacting Mach 1.2 flow. 3-D Reynolds-Averaged Navier Stokes (RANS) results are obtained for the various injector geometries using the Wind code with the Mentor s Shear Stress Transport turbulence model in both single and multi-species modes. Computed results for the injector mixing, penetration, and induced wall forces are presented. In the case of rectangular injectors, those longer in the direction of the freestream flow are predicted to generate the most mixing and penetration of the injector flow into the primary stream. These injectors are also predicted to provide the largest discharge coefficients and induced wall forces. Minor performance differences are indicated among diamond, circle, and square orifices. Grid sensitivity study results are presented which indicate consistent qualitative trends in the injector performance comparisons with increasing grid fineness.

Foster, Lancert↗

Cooling effectiveness of slot injection into a turbulent boundary layer

The cooling effectiveness of injection through multiple flush slots at an angle of 10 deg was studied experimentally in a wind tunnel. Air was injected from one to four slots into a turbulent Mach 6 boundary layer. The slot mass flow ratio is defined, and data which describe the dependence of the cooling effectiveness on the slot mass flow ratio are presented. Experimental values are indicated graphically for various cases of single and multiple slot injection, where the total mass injection (i.e., the sum of flow rates from each slot) is the same for each case. The results show that, for a given coolant mass flow rate, thermal protection over the maximum surface area can be accomplished best by injecting the coolant flow through multiple slots.

Howard, F. G.↗

Utah FORGE 4-2541: Optimization and Validation of a Plug-and-Perf Stimulation Treatment Design - Workshop Presentation

This is a presentation on the Optimization and Validation of a Plug-and-Perf Stimulation Treatment Design at Utah FORGE project by Fervo Energy, presented by Sireesh Dadi. The project's objective was to develop a multistage hydraulic stimulation approach designed specifically to target the top three factors that control the technical and commercial viability of an EGS system. These factors include: achieving sufficient injectivity to support high cross-well flow rates, distributing flow evenly across the wellbore and reservoir, and overcoming the effects of stress heterogeneity, stress shadowing, and variations in natural fracture properties during the stimulation treatment. This presentation was featured in the Utah FORGE R&D Annual Workshop on September 7, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development of Enhanced Geothermal Systems (EGS) reservoirs and resources.

15 GEOTHERMAL ENERGY↗

Flow visualization in long neck Helmholtz resonators with grazing flow

Both oscillating and steady flows were applied to a single plexiglass resonator cavity with colored dyes injected in both the orifice and grazing flow field to record the motion of the fluid. For oscillatory flow, the instantaneous dye streamlines were similar for both the short and long-neck orifices. The orifice flow blockage appears to be independent of orifice length for a fixed amplitude of flow oscillation and magnitude of the grazing flow. The steady flow dye studies showed that the acoustic and steady flow resistances do not necessarily correspond for long neck orifices.

Baumeister, K. J.↗

Flow visualization in long neck Helmholtz resonators with grazing flow

Both oscillating and steady flows were applied to a single plexiglass resonator cavity with colored dyes injected in both the orifice and grazing flow field to record the motion of the fluid. For oscillatory flow, the instantaneous dye streamlines were similar for both the short and long-neck orifices. The orifice flow blockage appears to be independent of orifice length for a fixed amplitude of flow oscillation and magnitude of the grazing flow. The steady flow dye studies showed that the acoustic and steady flow resistances do not necessarily correspond for long neck orifices.

Baumeister, K. J.↗

Stagnation and downstream viscous shock-layer solutions with radiation and coupled ablation injection

This paper describes a rigorous viscous shock-layer analysis for investigating high energy equilibrium flow fields about blunt axisymmetric bodies. The analysis includes radiation transfer, mass injection, diffusion, and viscous effects. Radiation transfer is calculated with a nongray radiation model that accounts for line and continuum radiation. The analysis can treat all levels of blowing for both stagnation and downstream flow. Results are presented for selected earth entry conditions that demonstrate the essential features of this analysis. Particular emphasis is given to the effects of mass injection on stagnation and downstream flow. Results for both specified and coupled ablation injection are presented.

Moss, J. N.↗

The Magnetic Helicity Budget of Solar Active Regions and Coronal Mass Ejections

We compute the magnetic helicity injected by transient photospheric horizontal flows in six solar active regions associated with halo coronal mass ejections (CMEs) that produced major geomagnetic storms and magnetic clouds (MCs) at 1 AU. The velocities are computed using the local correlation tracking (LCT) method. Our computations cover time intervals of 1 10-150 hr, and in four active regions the accumulated helicities due to transient flows are factors of 8-12 larger than the accumulated helicities due to differential rotation. As was first pointed out by DCmoulin and Berger, we suggest that the helicity computed with the LCT method yields not only the helicity injected from shearing motions but also the helicity coming from flux emergence. We compare the computed helicities injected into the corona with the helicities carried away by the CMEs using the MC helicity computations as proxies to the CME helicities. If we assume that the length of the MC flux tubes is I = 2 AU, then the total helicities injected into the corona are a factor of 2.94 lower than the total CME helicities. If we use the values of 1 determined by the condition for the initiation of the kink instability in the coronal flux rope or I = 0.5 AU then the total CME helicities and the total helicities injected into the corona are broadly consistent. Our study, at least partially, clears up some of the discrepancies in the helicity budget of active regions because the discrepancies appearing in our paper are much smaller than the ones reported in previous studies. However, they point out the uncertainties in the MC/CME helicity calculations and also the limitations of the LCT method, which underestimates the computed helicities.

Nindos, A.↗

OECD MCCI Project: Small-Scale Water Ingression and Crust Strength Tests (SSWICS), SSWICS-12 Test Data Report (Thermal Hydraulic Results)

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanisms that could provide long term debris cooling. The tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. SSWICS-12 is similar in many respects to the preceding tests, e.g., fully oxidized melt with concrete constituents, 30 cm melt diameter, inert basemat, quench at 1 bar, and condensation of steam with collection of the condensate to measure gross cooling rate. The major departure from previous tests is the addition of water injection nozzles cast within the basemat. Each injection line has its own water supply and flow rate sensor. The melt is partitioned into quadrants using metal plates to create, in effect, four independent and simultaneous injection tests. Each nozzle has a different driving head. The purpose of this experiment is to determine the following: 1) the minimum driving head required to ensure water, 2) injection into the melt. 3) the water flow rate to each nozzle, 4) the cooling rate of each melt quadrant, 5) the effect of water injection on crust morphology. The melt depth is 30 cm (versus 15 cm for all previous tests) so that it is closer to the 20-30 cm depth expected in a plant. This report includes a description of the test apparatus, the instrumentation, plots of the recorded data, and some rudimentary data reduction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evidence that the human cutaneous venoarteriolar response is not mediated by adrenergic mechanisms

The venoarteriolar response causes vasoconstriction to skin and muscle via local mechanisms secondary to venous congestion. The purpose of this project was to investigate whether this response occurs through alpha-adrenergic mechanisms. In supine individuals, forearm skin blood flow was monitored via laser-Doppler flowmetry over sites following local administration of terazosin (alpha(1)-antagonist), yohimbine (alpha(2)-antagonist), phentolamine (non-selective alpha-antagonist) and bretylium tosylate (inhibits neurotransmission of adrenergic nerves) via intradermal microdialysis or intradermal injection. In addition, skin blood flow was monitored over an area of forearm skin that was locally anaesthetized via application of EMLA (2.5 % lidocaine (lignocaine) and 2.5 % prilocaine) cream. Skin blood flow was also monitored over adjacent sites that received the vehicle for the specified drug. Each trial was performed on a minimum of seven subjects and on separate days. The venoarteriolar response was engaged by lowering the subject's arm from heart level such that the sites of skin blood flow measurement were 34 +/- 1 cm below the heart. The arm remained in this position for 2 min. Selective and non-selective alpha-adrenoceptor antagonism and presynaptic inhibition of adrenergic neurotransmission did not abolish the venoarteriolar response. However, local anaesthesia blocked the venoarteriolar response without altering alpha-adrenergic mediated vasoconstriction. These data suggest that the venoarteriolar response does not occur through adrenergic mechanisms as previously reported. Rather, the venoarteriolar response may due to myogenic mechanisms associated with changes in vascular pressure or is mediated by a non-adrenergic, but neurally mediated, local mechanism.

Non-NASA Center↗

CFD-Based Design of a Filming Injector for N+3 Combustors

An effort was undertaken to perform CFD analysis of fluid flow in Lean-Direct Injection (LDI) combustors with axial swirl-venturi elements coupled with a new fuel-filming injector design for next-generation N+3 combustors. The National Combustion Code (NCC) was used to perform non-reacting and two-phase reacting flow computations on a N+3 injector configuration, in a single-element and a five-element injector array. All computations were performed with a consistent approach towards mesh-generation, spray-, ignition- and kinetics-modeling with the NCC. Computational predictions of the aerodynamics of the injector were used to arrive at an optimal injector design that met effective area, aerodynamics, and fuel-air mixing criteria. LDI-3 emissions (EINOx, EICO and UHC) were compared with the previous generation LDI-2 combustor experimental data at representative engine cycle conditions.

combustion chambers↗

Modeling supercritical CO 2 flow and mineralization in reactive host rocks with PFLOTRAN v7.0

Understanding the flow and reactivity of CO 2 injected into geological reservoirs is important for many subsurface applications including secure geologic carbon storage (GCS), critical mineral extraction, enhanced geothermal systems (EGS), and enhanced oil recovery (EOR). Traditionally, subsurface CO 2 injection for GCS applications has focused on geologic formations with favorable subsurface configurations for CO 2 migration and trapping through non-reactive mechanisms such as structural, solubility, and petrophysical trapping. Recently, CO 2 -reactive rocks such as mafic and ultramafic basalts have been investigated for their potential to react with injected CO 2 in situ to simultaneously dissolve host rock minerals and mineralize CO 2 as carbonates. Engineering rapid CO 2 mineralization in the subsurface is attractive because of the increased density of stored CO 2 , the additional safety factors associated with solidification, and the potential to extract valuable critical minerals. Here we present recent developments in the parallel flow and reactive transport simulator PFLOTRAN to model coupled CO 2 -brine flow and reactive transport for a wide range of injection and production applications involving reactive CO 2 -brine systems. These developments are based on the well established and trusted CO 2 flow capabilities in the STOMP-CO 2 simulator. New capabilities added to PFLOTRAN include new CO 2 -brine equations of state with optional thermal coupling, several new constitutive relationships like capillary pressure smoothing and scanning path hysteresis, a fully implicit well model, and native linkage with PFLOTRAN's well-established reactive transport libraries. A series of benchmarks between PFLOTRAN and STOMP-CO 2 verify the newly developed CO 2 -brine flow capabilities. Demonstrations of coupled CO 2 -brine flow modeling and reactive transport show how CO 2 mineralization can be engineered in reactive host rocks. Finally, an example use case involving copper leaching by CO 2 and critical mineral extraction is presented to showcase the strengths of this new implementation. Several limitations still remain, including limited availability of field data to parameterize models. Future work should constrain the evolution of mineral surface area during mineralization and the temperature and/or pH dependence of geochemical reactions for specific systems of interest.

Critical Minerals↗

Spontaneous Ignition of Hydrothermal Flames in Supercritical Ethanol Water Solutions

Results are reported from recent tests where hydrothermal flames spontaneously ignited in a Supercritical Water Oxidation (SCWO) Test Cell. Hydrothermal flames are generally categorized as flames that occur when appropriate concentrations of fuel and oxidizer are present in supercritical water (SCW); i.e., water at conditions above its critical point (218 atm and 374 C). A co-flow injector was used to inject fuel, comprising an aqueous solution of 30-vol to 50-vol ethanol, and air into a reactor held at constant pressure and filled with supercritical water at approximately 240 atm and 425 C. Hydrothermal flames auto-ignited and quickly stabilized as either laminar or turbulent diffusion flames, depending on the injection velocities and test cell conditions. Two orthogonal views, one of which provided a backlit shadowgraphic image, provided visual observations. Optical emission measurements of the steady state flame were made over a spectral range spanning the ultraviolet (UV) to the near infrared (NIR) using a high-resolution, high-dynamic-range spectrometer. Depending on the fuel air flow ratios varying degrees of sooting were observed and are qualitatively compared using light absorption comparisons from backlit images.

hydrothermal flame↗

Numerical Solution of the Steady-State Network Flow Equations for a Non-Ideal Gas

Herein we formulate a steady-state network flow problem for non-ideal gas that relates injection rates and nodal pressures in the network to flows in pipes. For this problem, we present and prove a theorem on uniqueness of generalized solution for a broad class of non-ideal pressure-density relations that satisfy a monotonicity property. Further, we develop a Newton-Raphson algorithm for numerical solution of the steady-state problem, which is made possible by a systematic non-dimensionalization of the equations. The developed algorithm has been extensively tested on benchmark instances and shown to converge robustly to a generalized solution. Previous results [1]-[4], indicate that the steady-state network flow equations for an ideal gas are difficult to solve by the Newton-Raphson method because of its extreme sensitivity to the initial guess. In contrast, we find that non-dimensionalization of the steady-state problem is key to robust convergence of the Newton-Raphson method. We identify criteria based on the uniqueness of solutions under which the existence of a non-physical generalized solution found by a non-linear solver implies non-existence of a physical solution, i.e., infeasibility of the problem. Finally, we compare pressure and flow solutions based on ideal and non-ideal equations of state to demonstrate the need to apply the latter in practice. The solver developed in this article is open-source and is made available for both the academic and research communities as well as the industry.

97 MATHEMATICS AND COMPUTING↗

Application of laser velocimetry to an unsteady transonic flow

Measurements of mean velocity, turbulent kinetic energy, and turbulent shear stress have been obtained in an unsteady but periodic flow. Polystyrene spheres, 0.35-0.55 microns in diameter, were injected into the tunnel settling chamber to seed the flow for a laser velocimeter. Synchronized counters together with an encoding interface and digital-to-analog converters were used to record the data on an analog tape recorder. Profiles of velocity and turbulence quantities are presented for several times during the periodic flow.

Seegmiller, H. L.↗