Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hot wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Considerations for Femtosecond Laser Electronic Excitation Tagging in High-Speed Flows

Femtosecond laser electronic excitation tagging (FLEET) is an unseeded method for molecular tagging which offers valuable opportunities for measurement of high-speed (transonic, supersonic or hypersonic) flows. The unique nature of high-speed testing demands certain performance from FLEET such as satisfactory signal-to-noise ratio (SNR) at depressed static conditions (i.e., low temperatures, pressures and densities), wide dynamic range for velocity determination (especially single-shot), and measurements with acceptable accuracy and precision. This dissertation strives to evaluate FLEET in those regards and provide strategies to maximize the method's capabilities. A zero-dimensional kinetics model in nitrogen explains FLEET signal changes with pressure/density and/or temperature in terms of plasma-chemical reactions. Poorly known rate coefficients are tuned by comparing model output to measurements, with temporal agreement up to several hundred nanoseconds. Modeling reveals that initial signal peaks at reduced density because of slowed temporal evolution (and decay) of excited populations. Low temperatures enhance signal by enlarging cluster ion populations which contribute to excited species via electron-ion dissociative recombination. A purpose-built free jet facility provides experimental validation of the kinetics model and assesses FLEET velocimetry in low temperature and pressure/density conditions. Signal, lifetime, accuracy and precision results are obtained from unheated subsonic through Mach 4.0 operation of the facility, with best results noted. FLEET measurements of a sweeping jet (SWJ) actuator in compressible operation showcase its advantages in a highly unsteady jet containing subsonic through supersonic velocities. FLEET velocimetry is performed in the device's internal and external flow fields, with the latter compared to hot-wire anemometry. Internal measurements reveal the absence of shockwaves theorized to occur at high pressure ratios. Simultaneous qualitative measurements of compressible jet mixing are shown as a proof-of-concept. Overall, the work demonstrates that previous understanding of SWJ incompressible operation readily extends into the compressible realm. Practical aspects of performing FLEET velocimetry are detailed, along with strategies for improving measurement quality. Determination of a fundamental precision in nitrogen and air is attempted. Experiments show that increasing time delay and/or SNR improves velocimetry precision. A comparison of five camera systems indicates sensors with larger pixels capture higher SNR data and produce more precise results.

FLEET↗

Exit Boundary Layer Data for a Round Convergent Nozzle in Support of Numerical Simulation Efforts

An experiment is conducted with hot-wire anemometry to document the exit boundary layer characteristics of two nozzle configurations at jet Mach numbers up to 0.82. Far-field noise and jet plume experimental data from these two configurations have been used in Large Eddy Simulations (LES) of jets by colleagues at other Institutions. The current experiment provides the boundary layer data which have been identified as being critical for validation of the simulations since the initial conditions can significantly affect subsequent jet evolution and its radiated noise. The data exhibit fully turbulent boundary layers for the case with a pipe attached upstream of the nozzle. The case without the pipe involves ‘Blasius-like’ mean velocity profiles but a ‘highly disturbed laminar state’ with large turbulence intensities in a range of subsonic Mach numbers.

Transition↗

Transition induced by Streamwise Arrays of Roughness Elements on a Flat Plate in Mach 3.5 Flow

The flow behind streamwise arrays of roughness elements was examined with a hot-wire probe. The roughness elements had heights of approximately 20% and 40% of the boundary layer thickness and different spacings and orientations of these roughness elements were tested. The circular roughness elements were spaced two diameters apart or four diameters apart from center to center. Transition moved upstream only when the roughness elements were spaced four diameters apart. The rectangular roughness elements were oriented so that they were at a 45-degree angle relative to the leading edge of the plate. Tandem rectangular elements either had the same orientation or opposing orientation. Mean mass-flux and total-temperature profiles of the flow field downstream of the roughness elements were examined for mean-flow distortion. Mass-flux fluctuation profiles showed that a 45-kHz odd-mode disturbance was present downstream of the shorter circular roughness elements. The dominant instability downstream of the taller circular roughness elements was a 65–85 kHz even-mode disturbance. Mass-flux fluctuation profiles showed that the dominant mode downstream of the tandem rectangular roughness elements with the same orientation was similar to that of a single roughness element and centered at a frequency of approximately 55 kHz. The 55-kHz instability appeared to correspond to increased spanwise shear, and thus was determined to be an odd-like mode. The dominant instability downstream of the tandem roughness elements with opposing orientation was centered at a frequency of 65 kHz and did not transition in the measurement region.

Amanda Chou↗

Transition Induced by an Egg-Crate Roughness on a Flat Plate in Supersonic Flow

Measurements were made in the wake of a roughness patch with a hot wire to determine mode shapes and frequencies of the dominant instabilities. The egg-crate roughness pattern is an analytic function described by a sinusoidal equation, similar to arrays of discrete elements that are positioned in a spanwise and streamwise grid, which were considered in previous computations. This is an intermediate configuration toward understanding the underlying physics of pseudorandom distributed roughness. At a freestream unit Reynolds number of10.8×106/m, the boundary layer did not transition within the measurement region. The largest amplitude boundary layer instability was centered near 53 kHz and appeared to be similar to an antisymmetric mode centered behind the region downstream of all of the peaks in the egg-crate roughness. This mode was similar to a mode found to have the highest N factor in previous computational studies. At a freestream unit Reynolds number of12.6×106/m, the boundary layer transitioned to turbulence. The dominant instability was centered near 74 kHz and grew linearly before saturating and breaking down. The mode shape of the 74-kHz mode was again an antisymmetric mode centered behind all of the peaks in the egg-crate roughness.

Amanda Chou↗

Computational Fluid Dynamics Simulations of the Transonic Dynamics Tunnel Airstream Oscillator System

This paper presents computational fluid dynamics simulations of the flow in the NASA Langley Research Center Transonic Dynamics Tunnel (TDT) with the airstream oscillator system (AOS) in operation. Test section flow angle can be modulated using sinusoidally oscillating vanes which are located in pairs within the contraction section of the tunnel circuit. A compilation of previously published experimental data for validation has been reviewed that contains hot-wire anemometer and fast-response probe data acquired in an empty test section with the vanes oscillating in-phase and out-of-phase. These experimental data have not previously been compared with computational results. The present results provide an opportunity for validation of the simulations of the sinusoidal AOS flow field in the TDT test section. Computed tunnel centerline, lateral and cross-section contour data of flow angle and vorticity show that resolving the vane tip vortex is critical to accurately predicting the test section center flow angle. The computed results show, as do the experimental data, what appears to be a resonance at higher frequencies. It is currently not known what is the cause of that resonance. Further refinement of the mesh is expected to improve the comparisons with experimental data

Robert E Bartels↗

Measurements of Freestream Fluctuations in the Langley Research Center Unitary Plan Wind Tunnel

Measurements of the freestream disturbance environment were made in the high Machnumber leg of the NASA Langley Research Center Unitary Plan Wind Tunnel. The un-steady pitot pressure fluctuations and mass-flux fluctuations were measured with fast-response pressure transducers and hot wires, respectively. These were the first directmeasurements of the disturbance environment made in this facility’s test section. Thespectral content of the disturbances in the freestream show a significant amount of powerat frequencies below 100 Hz. At Mach 3.5 and Mach 4.6, there is also a broad peak in thespectra spanning from 100 Hz to 1 kHz. The RMS amplitude of the freestream mass-fluxfluctuations ranges from approximately 0.5% to 2.5%. The amplitude of the disturbancesincreases with Mach number but does not vary significantly with Reynolds number andstreamwise station. At Mach 2.4, the amplitude of the pitot pressure and mass-flux fluctu-ations is higher at the bottom of the tunnel than in the center of the tunnel. This increaseis likely due to the presence of a vortical structure near the bottom of the tunnel. Com-pared to similar facilities that operate in the same Mach number range, the freestreamdisturbance amplitudes follow similar trends and are within the same order of magnitude

freestream disturbance↗

Effect of Water Droplets Crossing the Boundary Layer in a Stagnation Point Configuration

An experimental study was conducted in the Vertical Icing Studies Tunnel at the Icing Physics Flow Laboratory of NASA Glenn Research Center to study the effect of water droplets crossing the boundary layer in a stagnation point configuration. The objective of the experiment was to determine if water droplets crossing a boundary layer create turbulent spots that accelerate the boundary layer transition from laminar to turbulent. Water droplets that crossed the boundary layer were generated with a nozzle installed in the plenum. The turbulence level in the boundary layer was measured with a hot wire system when the nozzle was off, air on, and air and water on. The results indicate that the presence of the nozzle alone did not affect the boundary layer. The activation of the nozzle to eject air only or to generate water droplets affected the turbulence level in the boundary layer. The continued study of this effect is needed because of its implications in the development of heat transfer models for icing codes.

Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

o Aircraft Icing↗

Boundary-layer Instability Measurements on a Cone at Freestream Mach 3.5

An experimental study was conducted in the NASA (National Aeronautics and Space Administration) Langley Supersonic Low-Disturbance Tunnel to investigate naturally-occurring instabilities in a supersonic boundary layer on a 7◦ half-angle cone at nominal freestream conditions: Mach 3.5, total temperature of 299.8K, and unit Reynolds numbers (millions per m) of 9.89, 13.85, 21.77, and 25.73. Instability measurements were acquired under noisy-flow and quiet-flow conditions. Pitot-pressure and calibrated hot-wire measurements were obtained using a model-integrated traverse system to document the model flow field. In noisy-flow conditions, growth rates and mode shapes achieved good agreement between the measured results and linear stability theory (LST). The corresponding N factor at transition from LST is N ≈ 3.9. Under quiet-flow conditions, the most unstable first-mode instabilities as predicted by LST were measured, but this mode was not the dominant instability measured in the boundary layer. Instead, the dominant instabilities were less-amplified, low-frequency disturbances predicted by LST, and grew according to linear theory. These low-frequency unstable disturbances were initiated by freestream acoustic disturbances through a receptivity process believed to occur near the branch I location of the cone. Under quiet-flow conditions, the boundary layer remained laminar up to the last measurement station for the largest unit Reynolds number, implying a transition N factor of N > 8.5.

Boundary Layer↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector concave total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the Isokinetic Probe version 2 (IKP2), which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window probes to the measurements made with the underwing and nose probes. The key findings were: (1) the Ice Crystal Detector concave water content sensor efficiency factor to glaciated conditions was similar to previous estimates, but reduced with increased ice crystal median mass diameter; (2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values—although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and (3) the ice water content at the 17 in. standoff from the port window varied from about 50 percent to nearly three times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Three-Dimensional Instantaneous Flow-field Reconstruction Using Planar Spectral Proper Orthogonal Decomposition

A novel method for three-dimensional flowfield reconstruction is presented that utilizes spectral proper orthogonal decomposition (SPOD). The time-resolved PIV data are acquired in multiple two-dimensional spanwise planes, with adequate streamwise spacing to resolve the out-of-plane wavelength. Knowledge of the out-of-plane phase speed is also required, and for the present case this value was obtained using instantaneous hot-wire measurements. The method is validated by comparing phase-averaged results acquired with a forcing signal to the SPOD reconstructed results using the same data. The method is also applied to data with no forcing applied, and the results are shown to be similar to the forced case. This method is particularly useful for cases in which there are multiple frequencies of interest, or cases in which the phenomena occur over a broad range of frequencies. This method allows reconstruction of the frequencies of interest without the need for a forcing signal, so the flow can be studied in its natural (undisturbed) state.

boundary-layer transition↗

Instabilities in the Wake of a Pseudorandom Roughness on a Supersonic Flat Plate

A roughness patch defined by a two-dimensional Fourier series was installed in a highly-polished flat plate model immersed in a supersonic quiet flow. The NASA Langley Research Center Supersonic Low Disturbance Tunnel is capable of providing a Mach 3.5 flow with low freestream acoustic noise and low turbulence levels. Measurements made with a hot-wire probe downstream of the roughness element showed the presence of instability modes that did not cause transition in the measurement region at a freestream unit Reynolds number of Re =12.6×10^6/m. The largest amplitude mode appeared to be similar to a symmetric mode. The same roughness patch immersed in a higher freestream acoustic noise environment showed little to no evidence of the instability modes. Instead, disturbances found in the boundary layer matched closely to the freestream spectra measured in the empty tunnel under the same conditions, indicating some evidence of freestream forcing in the boundary layer.

Roughness induced transition↗

Instabilities in the Wake of a Pseudorandom Roughness on a Supersonic Flat Plate

A roughness patch defined by a two-dimensional Fourier series was installed in a highly-polished flat plate model immersed in a supersonic quiet flow. The NASA Langley Research Center Supersonic Low Disturbance Tunnel is capable of providing a Mach 3.5 flow with low freestream acoustic noise and low turbulence levels. Measurements made with a hot-wire probe downstream of the roughness element showed the presence of instability modes that did not cause transition in the measurement region at a freestream unit Reynolds number of Re =12.6×10^6/m. The largest amplitude mode appeared to be similar to a symmetric mode. The same roughness patch immersed in a higher freestream acoustic noise environment showed little to no evidence of the instability modes. Instead, disturbances found in the boundary layer matched closely to the freestream spectra measured in the empty tunnel under the same conditions, indicating some evidence of freestream forcing in the boundary layer.

Roughness induced transition↗

Instabilities in the Wake of a Pseudorandom Roughness on a Supersonic Flat Plate

A roughness patch defined by a two-dimensional Fourier series was installed in a highly-polished flat plate model immersed in a supersonic quiet flow. The NASA Langley Research Center Supersonic Low Disturbance Tunnel is capable of providing a Mach 3.5 flow with low freestream acoustic noise and low turbulence levels. Measurements made with a hot-wire probe downstream of the roughness element showed the presence of instability modes that did not cause transition in the measurement region at a freestream unit Reynolds number of Re =12.6×10^6/m. The largest amplitude mode appeared to be similar to a symmetric mode. The same roughness patch immersed in a higher freestream acoustic noise environment showed little to no evidence of the instability modes. Instead, disturbances found in the boundary layer matched closely to the freestream spectra measured in the empty tunnel under the same conditions, indicating some evidence of freestream forcing in the boundary layer.

Roughness induced transition↗

Aerodynamic and Acoustic Performance Testing of Metal Spacecraft Cabin Ventilation Fan

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements included were: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. The present report documents the test setup. A series of follow on reports documents the results. These fan units, the data and the test facility described herein are valuable resources available for supporting NASA’s aeronautics research and space exploration missions.

Small Fan Noise↗

Quiet Spacecraft Cabin Ventilation Fan: Acoustic Measurements Results

A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the acoustic measurements as part of a series of reports.

o Small Fan Noise, Testing, Duct Modes↗

Quiet Spacecraft Cabin Ventilation Fan: Aerodynamic Measurements Results

A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were from: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the aerodynamic measurements as part of a series of reports.

Small Fan Noise,↗