Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Field Investigation of an Air-Source Cold Climate Heat Pump

In the U.S., there are approximately 2.6 million dwellings that use electricity for heating in cold and very cold regions with an annual energy consumption of 0.16 quads (0.17 EJ). A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (greater than 60% compared to electric resistance heating). We developed an air-source cold climate heat pump, which uses tandem compressors, with a single compressor rated for the building design cooling load, and running two compressors to provide, at -13 F (-25 C), 75% of rated heating capacity. The tandem compressors were optimized for heating operation and are able to tolerate discharge temperatures up to 280 F (138 C). A field investigation was conducted in the winter of 2015, in an occupied home in Ohio, USA. During the heating season, the seasonal COP was measured at 3.16, and the heat pump was able to operate down to -13 F (-25 C) and eliminate resistance heat use. The heat pump maintained an acceptable comfort level throughout the heating season. In comparison to a previous single-speed heat pump in the home, the CCHP demonstrated more than 40% energy savings in the peak heating load month. This paper illustrates the measured field performance, including compressor run time, frost/defrosting operations, distributions of building heating load and capacity delivery, comfort level, field measured COPs, etc.

Cold Climate Heat Pump↗

INFORMATION: Management Alert on the Department's Monitoring of the Weatherization Assistance Program in the State of Illinois

Under the American Recovery and Reinvestment Act of 2009 (Recovery Act), the Department of Energy's Weatherization Assistance Program received $5 billion to improve the energy efficiency of homes owned or occupied by low income persons, reduce their total residential expenditures, and improve their health and safety. Since the Recovery Act was enacted in February 2009, the Department has awarded weatherization grants to every state, the District of Columbia and five territories. Because of the unprecedented level of funding and the risks associated with spending vast amounts of money in a relatively short period of time, the Office of Inspector General (OIG) initiated a series of audits designed to evaluate the Program's internal control structures at both the Federal and state levels. As part of our work, we are in the process of reviewing Weatherization Program internal controls for the State of Illinois. We are also currently performing identical audits in the States of North Carolina, Pennsylvania and Virginia. Under the Recovery Act and the Department's Program, the State of Illinois received $242 million to weatherize 26,933 homes. The State of Illinois awarded these funds to 35 local agencies responsible for determining recipients' eligibility, contracting for the installation of the weatherization work, and conducting final inspections to ensure that work on homes was done in accordance with requirements. Inspectors working for the local agencies are required to evaluate the quality of mechanical and architectural improvements, such as furnace installations and window caulking, and certify that the work performed meets established standards. Under a Department approved plan in place at the time of our review, state officials were required to evaluate the sufficiency of local agency monitoring controls and to inspect the work performed on at least five percent of the units weatherized with Department funds during the program year for each local agency. We identified significant internal control deficiencies in the management of the Weatherization Program in Illinois which require immediate attention. Specifically, our audit testing revealed significant problems with on-site monitoring and inspection of the Illinois Home Weatherization Assistance Program (Illinois). We noted that the Department had not fulfilled its requirement to perform monitoring visits at the State level. In addition, Illinois officials had not complied with the Department's requirements for inspecting weatherization work conducted by local agencies. Finally, we found that a weatherization inspection for one of the local agencies failed to detect substandard installation of energy saving materials. This case involved a furnace gas leak that could have resulted in serious injury to the occupants and material damage to the structure. This is an interim report and our audit work remains in progress.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building a 40% Energy Saving House in the Mixed-Humid Climate

This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar fraction for this home located in Lenoir City, Tennessee, is predicted to be as high as 41%(accounting for both solar PV and the solar water heater). This all-electric home is predicted to use 25 kWh/day based on the one year of measured data used to calibrate a whole-building simulation model. Based on two years of measured data, the roof-mounted 2.2 kWp PV system is predicted to generate 7.5 kWh/day. The 2005 cost to commercially construct ZEH5, including builder profit and overhead, is estimated at about $150,000. This cost - for ZEH5's panelized construction, premanufactured utility wall (ZEHcor), foundation geothermal system, and the addition of the walkout lower level, and considering the falling cost for PV - suggests that the construction cost per ft2 for a ZEH5 two-story will be even more cost-competitive. The 2005 construction cost estimate for a finished-out ZEH5 with 2632 ft2 is $222,000 or $85/ft2. The intention of this report is to help builders and homeowners make the decision to build zero-energy-ready homes. Detailed drawings, specifications, and lessons learned in the construction and analysis of data from about 100 sensors monitoring thermal performance for a one-year period are presented. This information should be specifically useful to those considering structural insulated panel walls and roof, foundation geothermal space heating and cooling, solar water heater and roof-mounted, photovoltaic, grid-tied systems.

14 SOLAR ENERGY↗

Non-Intrusive Energy Disaggregation Using Non-Negative Matrix Factorization With Sum-to-k Constraint

Energy disaggregation or non-intrusive load monitoring addresses the issue of extracting device-level energy consumption information by monitoring the aggregated signal at one single measurement point without installing meters on each individual device. Energy disaggregation can be formulated as a source separation problem, where the aggregated signal is expressed as linear combination of basis vectors in a matrix factorization framework. In this paper, an approach based on Sum-to-k constrained non-negative matrix factorization (S2K-NMF) is proposed. By imposing the sum-to-k constraint and the non-negative constraint, S2K-NMF is able to effectively extract perceptually meaningful sources from complex mixtures. The strength of the proposed algorithm is demonstrated through two sets of experiments: Energy disaggregation in a residential smart home; and heating, ventilating, and air conditioning components energy monitoring in an industrial building testbed maintained at the Oak Ridge National Laboratory. Furthermore, extensive experimental results demonstrate the superior performance of S2K-NMF as compared to state-of-the-art decomposition-based disaggregation algorithms.

42 ENGINEERING↗

Combined Effects of Three High-Energy Charged Particle Beams Important for Space Flight on Brain, Behavioral and Cognitive Endpoints in B6D2F1 Female and Male Mice

The radiation environment in deep space includes the galactic cosmic radiation with different proportions of all naturally occurring ions from protons to uranium. Most experimental animal studies for assessing the biological effects of charged particles have involved acute dose delivery for single ions and/or fractionated exposure protocols. Here, we assessed the behavioral and cognitive performance of female and male C 57 BL/6J × DBA2/J F1 (B6D2F1) mice 2 months following rapidly delivered, sequential irradiation with protons (1 GeV, 60%), 16 O (250 MeV/n, 20%), and 28 Si (263 MeV/n, 20%) at 0, 25, 50, or 200 cGy at 4-6 months of age. Cortical BDNF, CD68, and MAP-2 levels were analyzed 3 months after irradiation or sham irradiation. During the dark period, male mice irradiated with 50 cGy showed higher activity levels in the home cage than sham-irradiated mice. Mice irradiated with 50 cGy also showed increased depressive behavior in the forced swim test. When cognitive performance was assessed, sham-irradiated mice of both sexes and mice irradiated with 25 cGy showed normal responses to object recognition and novel object exploration. However, object recognition was impaired in female and male mice irradiated with 50 or 200 cGy. For cortical levels of the neurotrophic factor BDNF and the marker of microglial activation CD68, there were sex × radiation interactions. In females, but not males, there were increased CD68 levels following irradiation. In males, but not females, there were reduced BDNF levels following irradiation. A significant positive correlation between BDNF and CD68 levels was observed, suggesting a role for activated microglia in the alterations in BDNF levels. Finally, sequential beam irradiation impacted the diversity and composition of the gut microbiome. These included dose-dependent impacts and alterations to the relative abundance of several gut genera, such as Butyricicoccus and Lachnospiraceae . Thus, exposure to rapidly delivered sequential proton, 16 O ion, and 28 Si ion irradiation significantly affects behavioral and cognitive performance, cortical levels of CD68 and BDNF in a sex-dependent fashion, and the gut microbiome.

59 BASIC BIOLOGICAL SCIENCES↗

Low-Dose Caffeine Administration During Acute Sleep Deprivation Eliminates Visual Motion Processing Impairment, but Does Not Improve Saccadic Rate

Oculomotor tracking performance changes according to time awake. A constant routine (CR) study demonstrated that increasing time awake 1) reduces the precision of visual motion processing, 2) decreases steady-state closed-loop pursuit performance and 3) decreases peak saccadic velocity. We aimed to determine the contribution of homeostatic sleep pressure on these oculometric changes by administering low-dose caffeine over one night of sleep deprivation. Participants completed two weeks of at-home 8.5 hours sleep per day, followed by an approximately 24-hour laboratory CR in semi-recumbent posture under less than 4 lux of light. The visual tracking task was performed every two hours after waking and hourly overnight. Low-dose caffeine of 0.3 milligrams per kilogram was administered hourly during the biological night. Nine participants (5F) completed the study. Caffeine dosing: 1) prevented the impairment of visual motion processing, 2) reduced by approximately half the impairment of closed-loop pursuit performance (gain, minus 0.47 percent per hour, significance of slope change: p (probability) less than 0.006; proportion smooth, minus 0.35 percent per hour, p less than 0.005), and 3) had an insignificant (p less than 0.39) effect on the impairment of saccadic peak velocity (slope, minus 1.13 percent per hour; intercept, minus 0.62 percent per hour). These results suggest that visual motion processing and some proportion of closed-loop pursuit performance are impaired due to homeostatic mechanisms during sleep deprivation.

Sleep↗

Extended Plate and Beam Wall System

Home Innovation Research Labs studied the extended plate and beam wall (EP&B) system during a two-year period from mid-2015 to mid-2017 to determine the wall’s structural performance, moisture durability, constructability, and cost effectiveness for use as a high-R enclosure system for energy code minimum and above-code performance in climate zones 4–8.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Cold Climate Heat Pump Challenge: Development, Metrics, and Early Field Observations

Space heating in residential buildings is a major contributor of Greenhouse Gas (GHG) emissions in the United States. New, advanced electric heat pumps are poised to provide a low carbon alternative to traditional fossil-based heating, especially in colder climates. Widespread deployment of cold climate heat pumps could help address the significant portion of building emissions and primary energy used in American households, but these gains will require broader acceptance from consumers and decision makers. As part of the “Energy, Emissions, and Equity” (E3) initiative, the U.S. Department of Energy launched the Cold Climate Heat Pump Challenge (CCHP) in 2021 to accelerate the deployment of the next generation of air source heat pumps. The Challenge is currently focused on residential, centrally ducted, electric heat pumps, with a nominal cooling capacity greater than or equal to 24,000 Btu/h (2 tons) and less than or equal to 65,000 Btu/h (5 tons). The Challenge specifications represent a best-in-class heat pump product that provides high-efficiency heating performance in cold climates, employs environmentally friendly low-Global Warming Potential (GWP) refrigerants, and is designed to be grid interactive. Spearheaded by DOE in partnership with the US Environmental Protection Agency (EPA) and Natural Resources Canada (NRCan), the CCHP Challenge brings together numerous major heat pump manufacturers and key stakeholders including utilities and state agencies across the country. In addition to performance testing in a laboratory environment, a key component of this research is evaluating the in-field performance of the prototype heat pumps developed as part of the Challenge. This paper will discuss the development of the CCHP Challenge, key performance specifications, and the energy and non-energy metrics that will be evaluated through the field study. The types of data that are being collected from the units installed in homes across North America as part of the field validation will be described, including details about the sensors and data acquisition system. Data cleaning and analysis methodologies will be discussed, along with early observations from the winter 2022-2023, spring and summer performance periods, and an assessment of non-energy metrics through pre- and post-installation homeowner surveys. Challenges uncovered and lessons learned throughout the process will also be discussed. Finally, the paper will discuss next steps for the second winter assessment period, areas needing additional research, and potential applications of the data collected and analyzed through this work.

Mendon, Vrushali V.↗

Double Wall Framing Technique An Example of High Performance, Sustainable Building Envelope Technology

Double wall technologies utilizing wood framing have been well-known and used in North American buildings for decades. Most of double wall designs use only natural materials such as wood products, gypsum, and cellulose fiber insulation, being one of few building envelope technologies achieving high thermal performance without use of plastic foams or fiberglass. Today, after several material and structural design modifications, these technologies are considered as highly thermally efficient, sustainable option for new constructions and sometimes, for retrofit projects. Following earlier analysis performed for U.S. Department of Energy by Fraunhofer CSE, this paper discusses different ways to build double walls and to optimize their thermal performance to minimize the space conditioning energy consumption. Description of structural configuration alternatives and thermal performance analysis are presented as well. Laboratory tests to evaluate thermal properties of used insulation and whole wall system thermal performance are also discussed in this paper. Finally, the thermal loads generated in field conditions by double walls are discussed utilizing results from a joined project performed by Zero Energy Building Research Alliance and Oak Ridge National Laboratory (ORNL), which made possible evaluation of the market viability of low-energy homes built in the Tennessee Valley. Experimental data recorded in two of the test houses built during this field study is presented in this work.

Building Envelope↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses.The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Storage Integrated into Air-Source Heat Pumps to Leverage Building Electrification: A Systematic Literature Review

Air-source heat pumps (ASHPs) can support a decarbonized economy by replacing combustion appliances in homes and electrifying heating systems in buildings. However, ASHPs have not seen significant adoption primarily due to deteriorated performance under cold conditions - at very low temperatures they require auxiliary resistance heating to meet the heating demand and defrost the evaporator. The additional heat lowers the system efficiency. Thermal energy storage (TES) is a candidate technology to help overcome some of these issues. This paper presents a systematic literature review to map the existing research on the integration of TES into ASHPs. Our review of 59 publications indicates that thermal storage increases the ASHP coefficient of performance by 27% on average, albeit with higher initial cost compared to conventional fossil-fueled heating systems. Phase change materials may be ideal to be integrated with ASHPs due to their high energy density and compact design, but only a few publications address TES sizing and design. First and Second Laws of Thermodynamics are widely used to create metrics to assess ASHP-TES integration, and only recently have cost and environmental impact been explored. This literature review suggests that more comprehensive metrics are needed to evaluate the potential benefits of ASHP-TES systems.

air source heat pump↗

Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practice

Low-cost indoor air quality (IAQ) sensors are increasingly being used in homes and commercial and public buildings, driven by growing concerns about the impact of air on health, cognitive performance, and occupant wellbeing. These sensors offer a potentially transformative opportunity to increase spatial and temporal coverage of IAQ monitoring at a fraction of the cost of conventional reference instruments. However, their widespread use raises questions around accuracy, calibration, placement, data handling and interpretation, and integration into existing standards and workflows. This paper presents ten critical questions concerning the use of low-cost IAQ sensors in buildings, drawing on the latest empirical research, field deployments, and emerging practice. It discusses potential frameworks for deployment and evaluation, examines current sensor capabilities for measuring common pollutants, identifies methodological gaps in validation and uncertainty quantification, and outlines the extent to which existing IAQ standards can accommodate sensor-based evidence. The paper also explores how monitoring needs and deployment models vary by building type, the potential of real-time IAQ data to support building operations, and the ethical and legal implications of widespread sensor use. While significant challenges remain in ensuring data quality and building stakeholder trust, new applications are emerging through open data initiatives and advances in analytics and visualization. As the technology, science, and standards co-evolve, low-cost IAQ sensors are poised to become integral to routine building operation, building science, and environmental health research.

Parkinson, Thomas↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses. The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PATHS: Career Pathways to Advance the Trades in HVAC Services

The Career Pathways to Advance the Trades in HVAC Services (“PATHS”) project was designed to advance EERE/BTO goals of dramatically reducing the energy consumed in homes nationwide. Installing HVAC systems correctly and going back to provide tune-ups (maintenance) can improve their performance by at least 30%, so HVAC Technicians are critical to achieving GHG goals. However, there is a lack of trained technicians: residential HVAC installers and service technicians are retiring faster than they are being recruited, and workers with the advanced skills needed to install and service more complicated heat pump systems are even more scarce. Paradoxically, at the same time, unemployment and underemployment are still problems, particularly in disadvantaged communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset for: Rooftop solar and energy storage programs can remediate energy-limiting behaviors of energy insecure households

Energy insecurity affects most low-income households in the United States. Energy insecurity, which is characterized by a household’s inability to afford their energy needs, often leads to risky choices, causing other forms of insecurity including food and health. Although there are government programs designed to provide relief to low-income households that face energy insecurity, eligibility for these programs is usually determined by household income, and those with incomes close to the threshold face uncertainty or may be left out. In many cases, these households turn to energy-limiting behaviors as a strategy to lower their electric utility bills. This paper explores the relationship between energy insecurity and energy-limiting behaviors to investigate alternative solutions that target the households that may fall out of available energy assistance programs. We explore the role of battery energy storage systems and rooftop solar photovoltaics in improving energy affordability. The results show that residential rooftop solar and behind-the-meter energy storage can offset two-thirds of the bill savings that households attain through energy-limiting behavior. Household renewable energy systems could complement existing energy assistance programs to provide long-term bill relief, enabling occupants to live in their homes with comfort and dignity. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit.

Kerby, Jessica [Pacific Northwest National Laborat↗

An Explicit Linear Filtering Solution for the Optimization of Guidance Systems with Statistical Inputs

The determination of optimum filtering characteristics for guidance system design is generally a tedious process which cannot usually be carried out in general terms. In this report a simple explicit solution is given which is applicable to many different types of problems. It is shown to be applicable to problems which involve optimization of constant-coefficient guidance systems and time-varying homing type systems for several stationary and nonstationary inputs. The solution is also applicable to off-design performance, that is, the evaluation of system performance for inputs for which the system was not specifically optimized. The solution is given in generalized form in terms of the minimum theoretical error, the optimum transfer functions, and the optimum transient response. The effects of input signal, contaminating noise, and limitations on the response are included. From the results given, it is possible in an interception problem, for example, to rapidly assess the effects on minimum theoretical error of such factors as target noise and missile acceleration. It is also possible to answer important questions regarding the effect of type of target maneuver on optimum performance.

Stewart, Elwood C.↗

STS-114: Crew Interviews 1. Andy Thomas 2. Steve Robinson

STS-114 Mission Specialists, Andy Thomas and Steve Robinson, are seen in this pre-flight interview. Andy Thomas begins by talking about his interest in spaceflight as a young boy growing up in Australia. He expresses that the chances of an Australian boy studying to eventually become an astronaut was very remote. His Mechanical Engineering Degree in Australia and a Doctorate enabled him to acquire unique skills to come to the United States to work for Lockheed Martin. On the topic of return to flight, he reflects on experiences that he had working with the Michael Anderson and Kalpana Chawla of the ill-fated Space Shuttle Columbia. He also talks about the safety of the Space Shuttle Discovery and repairs to its Thermal Protection system. He explains in detail the Logistics Flight (LF) 1, spacewalks, Multipurpose Logistics Module (MPLM) and the External Stowage Platform (ESP)-2. Steve Robinson expresses that he had many interests as a child and becoming an astronaut was one of them. He was fascinated with things that fly and wanted to find out how they flew. He also designed hang gliders as a teenager. He expresses how his family feels about the risky business of spaceflight. He talks about how the space shuttle discovery crew will remember the Columbia crew by including seven stars on their patch so that they can bring them into orbit and then back home. Robinson also talks about his primary job, and the spacewalks that he and Soichi Noguchi will be performing.

Source record↗