Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Fiberboard Humidity Data for 9975 Shipping Packages

The 9975 surveillance program is identifying a technical basis to support extending the storage period of 9975 packages in KAC beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Two efforts have been undertaken to better understand the levels and behavior of moisture within the fiberboard assemblies of the 9975 shipping package. In the first effort, an initial survey of humidity and temperature in the upper air space of 26 packages stored in KAC was made. The data collected within this first effort help to illustrate how the upper air space humidity varies with the local ambient temperature and package heat load. In the second effort, direct measurements of two test packages are providing a correlation between humidity and fiberboard moisture levels within the package, and variations in moisture throughout the fiberboard assembly. This effort has examined packages with cane fiberboard and internal heat levels of 5 and 10W to date. Additional testing is expected to include 15 and 19W heat levels, and then repeat the same four heat levels with softwood fiberboard assemblies. This report documents the data collected to date within these two efforts.

36 MATERIALS SCIENCE↗

Fiberboard Humidity Data for 9975 Shipping Packages

The 9975 surveillance program is identifying a technical basis to support extending the storage period of 9975 packages in KAC beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Two efforts have been undertaken to better understand the levels and behavior of moisture within the fiberboard assemblies of the 9975 shipping package. In the first effort, an initial survey of humidity and temperature in the upper air space of 26 packages stored in KAC was made. The data collected within this first effort help to illustrate how the upper air space humidity varies with the local ambient temperature and package heat load. In the second effort, direct measurements of two test packages are providing a correlation between humidity and fiberboard moisture levels within the package, and variations in moisture throughout the fiberboard assembly. This effort has examined packages with cane fiberboard and internal heat levels of 5 and 10W to date. Additional testing is expected to include 15 and 19W heat levels, and then repeat the same four heat levels with softwood fiberboard assemblies. This report documents the data collected to date within these two efforts

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal-hydraulics modeling for prototype testing of the W7-X high heat flux scraper element

The long-pulse operation of the Wendelstein 7-X (W7-X) stellarator experiment is scheduled to begin in 2020. This operational phase will be equipped with water-cooled plasma facing components to allow for longer pulse durations. Certain simulated plasma scenarios have been shown to produce heat fluxes that surpass the technological limits on the edges of the divertor target elements during steady-state operation. In order to reduce the heat load on the target elements, the addition of a “scraper element” (SE) is under investigation. The SE is composed of 24 water-cooled carbon fiber reinforced carbon composite monoblock units. Multiple full-scale prototypes have been tested in the GLADIS high heat flux test facility. Previous computational studies revealed discrepancies between the simulations and experimental measurements. In this work, single-phase thermal-hydraulics modeling was performed in ANSYS CFX to identify potential causes for such discrepancies. Possible explanations investigated were the effects of a non-uniform thermal contact resistance and a potential misalignment of the monoblock fibers. And while the difference between the experimental and computational results was not resolved by a non-uniform thermal contact resistance, the computational results provided insight into the potential performance of a W7-X monoblock unit. Circumferential temperature distributions highlighted the expected boiling regions of such a unit. Finally, simulations revealed that modest angles of fiber misalignment in the monoblocks result in asymmetries at the unit edges and provide temperature differences similar to the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of Vehicle Air Conditioning Pull-Down Period

Air conditioner usage was characterized for high heat-load summer conditions during short driving trips using a 2009 Ford Explorer and a 2009 Toyota Corolla. Vehicles were parked in the sun with windows closed to allow the cabin to become hot. Experiments were conducted by entering the instrumented vehicles in this heated condition and driving on-road with the windows up and the air conditioning set to maximum cooling, maximum fan speed and the air flow setting to recirculate cabin air rather than pull in outside humid air. The main purpose was to determine the length of time the air conditioner system would remain at or very near maximum cooling power under these severe-duty conditions. Because of the variable and somewhat uncontrolled nature of the experiments, they serve only to show that for short vehicle trips, air conditioning can remain near or at full cooling capacity for 10-minutes or significantly longer and the cabin may be uncomfortably warm during much of this time.

42 ENGINEERING↗

Effect of wall temperature spatial variations on aerodynamic heating to an actively cooled aircraft

The design of cooled skin panels, which requires consideration of many parameters such as heat load, skin thickness, panel size, tube spacing, tube size, temperature limits, coolant flow, etc., must minimize weight and thermal stresses. A design procedure for such panels has been developed by Bell Aerospace Company (Helenbrook and Anthony, 1971). This design procedure assumes a uniform heating rate to the panel, i.e., the variation of aerodynamic heating rate due to the cyclic wall temperature distribution, which results from the discrete coolant tube locations in such a panel, has been neglected. This study was made to determine if these variations were sufficiently large to cause variations in aerodynamic heating rate which would require coupling of boundary layer and conductive thermal analysis solutions.

Jones, R. A.↗

A Novel Silicon Micromachined Integrated MCM Thermal Management System

"Micromachining" is a chemical means of etching three-dimensional structures, typically in single- crystalline silicon. These techniques are leading toward what is coming to be referred to as MEMS (Micro Electro Mechanical Systems), where in addition to the ordinary two-dimensional (planar) microelectronics, it is possible to build three-dimensional n-ticromotors, electrically- actuated raicrovalves, hydraulic systems and much more on the same microchip. These techniques become possible because of differential etching rates of various crystallographic planes and materials used for semiconductor n-ticrofabfication. The University of Cincinnati group in collaboration with Karl Baker at NASA Lewis were the first to form micro heat pipes in silicon by the above techniques. Current work now in progress using MEMS technology is now directed towards the development of the next generation in MCM (Multi Chip Module) packaging. Here we propose to develop a complete electronic thermal management system which will allow densifica6on in chip stacking by perhaps two orders of magnitude. Furthermore the proposed technique will allow ordinary conu-nercial integrated chips to be utilized. Basically, the new technique involves etching square holes into a silicon substrate and then inserting and bonding commercially available integrated chips into these holes. For example, over a 100 1/4 in. by 1 /4 in. integrated chips can be placed on a 4 in. by 4 in. silicon substrate to form a Multi-Chip Module (MCM). Placing these MCM's in-line within an integrated rack then allows for three-diniensional stacking. Increased miniaturization of microelectronic circuits will lead to very high local heat fluxes. A high performance thermal management system will be specifically designed to remove the generated energy. More specifically, a compact heat exchanger with milli / microchannels will be developed and tested to remove the heat through the back side of this MCM assembly for moderate and high heat flux applications, respectively. The high heat load application of particular interest in mind is the motor controller developed by Martin Marietta for Nasa to control the thruster's directional actuators on space vechicles. Work is also proposed to develop highly advanced and improved porous wick structures for use in advanced heat loops. The porous wick will be micromachined from silicon using MEMS technology, thus permitting far superior control of pore size and pore distribution (over wicks made from sintered n-ietals), which in turn is expected to led to significantly improved heat loop performance.

Kazmierczak, M. J.↗

Porous Plug Phase Separator and Superfluid Film Flow Suppression System for the Soft X-Ray Spectrometer Onboard Hitomi

When using superfluid helium in low gravity environments, porous plug phase separators are commonly used to vent boiloff gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ~ 30 ug/s, equivalent to ~ 0.7 mW heat load. It is therefore critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 ug/s, corresponding to a loss of cooling capacity of <40 uW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. In this paper, design, on-ground testing results and in-orbit performance are described.

Porous↗

Considerations for in situ, real time measurement of plasma-material interactions using Digital Holographic imaging

Digital Holographic (DH) imaging is a laser-based measurement technique, which can be used to monitor a material surface as it is being exposed to fusion-relevant plasmas. Both single-laser and dual-laser DH measurements have been demonstrated ex situ at Oak Ridge National Laboratory (ORNL). A DH diagnostic system is being assessed for deployment at ORNL to make in situ, real-time measurements of plasma erosion/redeposition in the Prototype Material Plasma Exposure eXperiment (Proto-MPEX). In situ, real time measurements pose unique challenges to diagnostic systems, which are not encountered by ex situ analysis techniques. The absolute surface height (tracked at the nm to μm position) during plasma exposure can be modified by: 1) surface movement due to vibration or thrust exerted by the plasma device, 2) surface growth due to the thermal expansion of the material under steady MW/m2 or transient GW/m2 plasma heat loads, and 3) surface modification due to plasma erosion/redeposition of the material substrate. To assess these effects, 1) the vibration spectrum of the diagnostic and the pulsed plasma device have been measured, 2) the thermal growth of the surface has been measured for an applied heat flux, and 3) the surface modification has been measured ex situ post plasma exposure, and ex situ post laser ablation as a proxy for the plasma. This paper will provide an overview of the results that have been achieved in the development of a DH diagnostic for in situ real-time measurements of plasma exposed surfaces in the Proto-MPEX device.

Biewer, Theodore↗

Analytical and experimental investigations of the oblique detonation wave engine concept

Wave combustors, which include the Oblique Detonation Wave Engine (ODWE), are attractive propulsion concepts for hypersonic flight. These engines utilize oblique shock or detonation waves to rapidly mix, ignite, and combust the air-fuel mixture in thin zones in the combustion chamber. Benefits of these combustion systems include shorter and lighter engines which will require less cooling and can provide thrust at higher Mach numbers than conventional scramjets. The wave combustor's ability to operate at lower combustor inlet pressures may allow the vehicle to operate at lower dynamic pressures which could lessen the heating loads on the airframe. The research program at NASA-Ames includes analytical studies of the ODWE combustor using CFD codes which fully couple finite rate chemistry with fluid dynamics. In addition, experimental proof-of-concept studies are being carried out in an arc heated hypersonic wind tunnel. Several fuel injection designs were studied analytically and experimentally. In-stream strut fuel injectors were chosen to provide good mixing with minimal stagnation pressure losses. Measurements of flow field properties behind the oblique wave are compared to analytical predictions.

Menees, Gene P.↗

Disaggregating Smart Meter Data to Identify Electric Loads and Control Opportunities

As utility data, such as smart meter data, becomes more broadly available, there is general interest in using it to improve utility operations and enable adoption of other advanced technology - such as solar photovoltaics (PV), energy storage, and controls. We explore one such use case - identifying electric resistance water heaters from smart meter data, as well as characterizing their potential for load-shifting to support grid voltage stability under high-penetration PV adoption. This paper shows the limitation of typical 15-minute data, and how shortterm capture of additional 1-minute data is needed to enable the desired application. Results indicate about 4 kWh water heating load can be shifted to align with peak sun hours in a low use home. This methodology is an example, and can be adapted to other grid-integrated efficient building use cases.

14 SOLAR ENERGY↗

Analytical and experimental investigations of the oblique detonation wave engine concept

Wave combustors, which include the oblique detonation wave engine (ODWE), are attractive propulsion concepts for hypersonic flight. These engines utilize oblique shock or detonation waves to rapidly mix, ignite, and combust the air-fuel mixture in thin zones in the combustion chamber. Benefits of these combustion systems include shorter and lighter engines which require less cooling and can provide thrust at higher Mach numbers than conventional scramjets. The wave combustor's ability to operate at lower combustor inlet pressures may allow the vehicle to operate at lower dynamic pressures which could lessen the heating loads on the airframe. The research program at NASA-Ames includes analytical studies of the ODWE combustor using Computational Fluid Dynamics (CFD) codes which fully couple finite rate chemistry with fluid dynamics. In addition, experimental proof-of-concept studies are being performed in an arc heated hypersonic wind tunnel. Several fuel injection design were studied analytically and experimentally. In-stream strut fuel injectors were chosen to provide good mixing with minimal stagnation pressure losses. Measurements of flow field properties behind the oblique wave are compared to analytical predictions.

Menees, Gene P.↗

Real time capable infrared thermography for ASDEX Upgrade

Infrared (IR) thermography is widely used in fusion research to study power exhaust and incident heat load onto the plasma facing components. Due to the short pulse duration of today’s fusion experiments, IR systems have mostly been designed for off-line data analysis. For future long pulse devices (e.g., Wendelstein 7-X, ITER), a real time evaluation of the target temperature and heat flux is mandatory. This paper shows the development of a real time capable IR system for ASDEX Upgrade. A compact IR camera has been designed incorporating the necessary magnetic and electric shielding for the detector, cooler assembly. The camera communication is based on the Camera Link industry standard. The data acquisition hardware is based on National Instruments hardware, consisting of a PXIe chassis inside and a fibre optical connected industry computer outside the torus hall. Image processing and data evaluation are performed using real time LabVIEW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing custom fire behavior fuel models from ecologically complex fuel structures for upper Atlantic Coastal Plain forests.

Currently geospatial fire behavior analyses are performed with an array of fire behavior modeling systems such as FARSITE, FlamMap, and the Large Fire Simulation System. These systems currently require standard or customized surface fire behavior fuel models as inputs that are often assigned through remote sensing information. The ability to handle hundreds or thousands of measured surface fuelbeds representing the fine scale variation in fire behavior on the landscape is constrained in terms of creating compatible custom fire behavior fuel models. In this study, we demonstrate an objective method for taking ecologically complex fuelbeds from inventory observations and converting those into a set of custom fuel models that can be mapped to the original landscape. We use an original set of 629 fuel inventory plots measured on an 80,000 ha contiguous landscape in the upper Atlantic Coastal Plain of the southeastern United States. From models linking stand conditions to component fuel loads, we impute fuelbeds for over 6000 stands. These imputed fuelbeds were then converted to fire behavior parameters under extreme fuel moisture and wind conditions (97th percentile) using the fuel characteristic classification system (FCCS) to estimate surface fire rate of spread, surface fire flame length, shrub layer reaction intensity (heat load), non-woody layer reaction intensity, woody layer reaction intensity, and litter-lichen-moss layer reaction intensity. We performed hierarchical cluster analysis of the stands based on the values of the fire behavior parameters. The resulting 7 clusters were the basis for the development of 7 custom fire behavior fuel models from the cluster centroids that were calibrated against the FCCS point data for wind and fuel moisture. The latter process resulted in calibration against flame length as it was difficult to obtain a simultaneous calibration against both rate of spread and flame length. The clusters based on FCCS fire behavior parameters represent reasonably identifiable stand conditions, being: (1) pine dominated stands with more litter and down woody debriscomponents than other stands, (2) hardwood and pine stands with no shrubs, (3) hardwood dominated stands with low shrub and high non-woody biomass and high down woody debris, (4) stands with high grass and forb (i.e., non-woody) biomass as well as substantial shrub biomass, (5) stands with both high shrub and litter biomass, (6) pine-mixed hardwood stands with moderate litter biomass and low shrub biomass, and (7) baldcypress-tupelo stands. Models representing these stand clusters generated flame lengths from 0.6 to 2.3 musing a 30 km h{sub 1} wind speed and fireline intensities of 100-1500 kW m{sub 1} that are typical within the range of experience on this landscape. The fuel models ranked 1 < 2 < 7 < 5 < 4 < 3 < 6 in terms of both flame length and fireline intensity. The method allows for ecologically complex data to be utilized in order to create a landscape representative of measured fuel conditions and to create models that interface with geospatial fire models.

09 BIOMASS FUELS↗

On detachment asymmetry and stability

Three issues related to the physics of divertor detachment are analyzed in detail: the criteria for the onset of complete divertor detachment, the role of neutrals in “symmetryzation” of detachment in the inner and outer divertors, and the transition to divertor detachment. The results of comprehensive 2D numerical simulations with the SOLPS4.3 package are compared with some experimental data and predictions based on simplified analytical models. It is shown that it is the ratio of the upstream plasma pressure to the specific power flux entering the recycling region that controls the local onset of detachment on a specific flux tube. P up /q reclycl ≥(P up /q reclycl ) crit remains the valid criterion also in the presence of seeded impurity, if the impurity radiation and hydrogen recycling regions are spatially separated. Detailed analysis indicates that the reverse plasma flow forming on the most heat loaded flux tubes in the outer divertor under the influence of the neutrals coming from the deeply detached inner divertor plays the key role in the detachment “symmetryzation” and allows the outer divertor to reach the detached regime. Finally, it is demonstrated that a gradual increase of the perpendicular heat transport in the edge plasma during transition to the detached regime can make this transition bifurcation-like.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stray-Capacitance As a Simple Tool for Monitoring and Locating Heat Generation Demonstrated in Three Superconducting Magnets

Real-time monitoring of heat loads in cryogenic systems is critical for many applications, particularly high field magnets. In this work, we demonstrated that by monitoring changes in the capacitance of local probes consisting of thin metal strips with a porous glass fiber dielectric, boiling helium from as little as 0.1 J of deposited heat can be located by an analysis of the response speed and amplitude in nearby probes. We further implemented stray-capacitance monitoring of a magnet's metal support structures, a more global probe of the magnet volumes, in three high temperature superconducting Bi-2212 magnet types. Global structural stray-capacitance monitoring was evaluated for a single racetrack coil, a common coil dipole, and a canted cosine theta winding, showing a quench response comparable to voltage signals without inductive effects. The response of the local and global probes was compared in the single racetrack coil with well-known quench properties. Monitoring the cool-down of the common coil dipole demonstrated the added benefit of the global stray-capacitance as a liquid level monitor. This simple method of monitoring the capacitance has proven to be a versatile and robust technique for monitoring and locating heat.

43 PARTICLE ACCELERATORS↗

Advanced radiator systems for space power

Space power systems generating powers of 1 MWe and higher will require new approaches in radiator design in order to reject large waste heat loads without the unmanageable weight burden of conventional pumped-loop radiator systems. This paper discusses recent design concepts for radiator systems which have the potential for reducing radiator mass by as much as an order of magnitude below the mass of conventional systems. These advanced concepts, including the heat pipe radiator, particle (dust and droplet) radiators, moving belt radiator, rotating membrane radiator, and several interesting variations of these, achieve low mass by reducing the armor requirement for protection against micrometeoroids. The design and performance of each of these concepts is discussed, along with technical issues which must be addressed to bring these concepts to fruition.

Mattick, A. T.↗