At least 901 records · Page 50

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

Analysis of Energy Justice and Equity Impacts from Replacing Peaker Plants with Energy Storage

Transitions to low-carbon energy systems are essential to mitigating and adapting to climate change. Energy storage systems are a key component in achieving a viable decarbonized electric grid. However, decarbonization alone does not guarantee a fairer, more inclusive, or socially just energy system. Energy equity and justice should be integrated in energy system transitions to ensure benefits and burdens are shared equitably. In this paper, we discuss the relationship between energy storage and social equity by assessing the use of energy storage to replace natural gas-fired (NG) peaker plants. Peaker plants are disproportionately located near disadvantaged communities and tend to be older and high emitters of health-affecting fine particulate matter and other pollutants. This paper investigates the equity implications of NG peaker plant replacements with battery energy storage in the context of Washington State’s peaker plants to highlight the human-centered values of retiring the plants. The study performed production cost simulations using the latest Western Electric Coordinating Council Anchor Dataset 2030 case and found that total generation cost, locational marginal price, and total annual emissions were reduced with the replacements. These reductions will have equity benefits on local communities including access to clean air, enhanced health outcomes, and energy burden reductions.

Tarekegne, Bethel W.↗

Modeling and Optimizing Pumped Storage in a Multi-stage Large Scale Electricity Market under Portfolio Evolution

To leverage the fast-ramping capability of resources to provide great value to the grid, electricity system operators such as the Midcontinent Independent System Operator (MISO) continue to evolve their approaches for integrating energy storage resources, including pumpedstorage hydro (PSH), into the electricity markets. However, new challenges arise in modeling and optimizing these energy-limited resources across multiple market clearing processes and planning studies with uncertainties and imperfect information. For instance, current market practices of PSH owners specifying pumping/generating hours can result in sub-optimal generation dispatch. Letting grid operators optimize PSH with the consideration of multiple operating modes and energy limitation constraints can potentially bring economic benefits to both the system and the PSH owners. However, in multi-stage clearing process of electricity markets, utilizing the PSH flexibility to deal with realized uncertainties can cause deviation in the multi-stage scheduling processes. The resulting financial risks from the schedule deviation may not be acceptable to PSH owners. In addition, to effectively utilize this energy limited resource, the state of charge (SOC) constraints of PSH needs to be continuously optimized and the marginal cost of deviation need to reflect the expected cost to purchase or sell energy at future times to compensate for deviations. This project aims to develop a prototype enhanced PSH model and improved price signals in the multi-stage market clearing process with proper consideration of the unique characteristics of PSH, in order to better align underlying PSH capabilities with evolving grid needs, particularly including the needs for more frequent and larger cycling to manage variability and uncertainty from renewables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100 Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

Borrego Springs↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100% Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

blackstart with fuel cells↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

New roads and challenges for fuel cells in heavy-duty transportation

The recent release of hydrogen economy roadmaps for several major countries emphasizes the need for accelerated worldwide investment in research and development activities for hydrogen production, storage, infrastructure and utilization in transportation, industry and the electrical grid. Due to the high gravimetric energy density of hydrogen, the focus of technologies that utilize this fuel has recently shifted from light-duty automotive to heavy-duty vehicle applications. Decades of development of cost-effective and durable polymer electrolyte membrane fuel cells must now be leveraged to meet the increased efficiency and durability requirements of the heavy-duty vehicle market. This Review summarizes the latest market outlooks and targets for truck, bus, locomotive and marine applications. Required changes to the fuel-cell system and operating conditions for meeting Class 8 long-haul truck targets are presented. The necessary improvements in fuel-cell materials and integration are also discussed against the benchmark of current passenger fuel-cell electric vehicles.

08 HYDROGEN↗

A Review of Quantum Computing Technologies in Power System Optimization

As modern power grids increasingly integrate variable renewable generation, distributed energy resources, and energy storage systems, classical optimization techniques are facing unprecedented challenges. This review examines the emerging application of quantum computing to overcome these challenges in power system optimization, including optimal power flow (OPF), unit commitment (UC), economic dispatch (ED), and intelligent switching and topology optimization (IS-TO). Recent research has introduced various quantum methodologies—such as gate-based, annealing-based, variational algorithms, and quantum-inspired algorithms—to address the combinatorial complexity inherent in grid reconfiguration and energy management. The review summaries the quantum algorithms, quantum devices and the power system test cases, highlighting hybrid quantum–classical strategies that leverage the complementary strengths of both paradigms. Some quantum advantages have been observed, including theoretical speedup, accurate simulation results, scalable qubit usage, efficient QUBO mapping. In particular, the review emphasizes the importance of integrating quantum optimization techniques with classical control frameworks, these hybrid approaches demonstrate the potential to improve real-time grid management and operational reliability. A significant portion of the analysis is devoted to the practical limitations of current quantum devices. Present-day quantum hardware, operating in the noisy intermediate-scale quantum (NISQ) era, remains highly sensitive to noise and limited in qubit connectivity, which constrains the scale and accuracy of implemented algorithms. The review delves into specific challenges such as the need for qubit-efficient encoding techniques and error mitigation strategies that are critical for handling real-world grid optimization problems. In addition, the work draws attention to the performance discrepancies between theoretical quantum speedups and experimental validations, underscoring the importance of rigorous benchmark studies using representative power grid test cases. In summary, this review highlights both the promise and limitations of quantum computing for power system optimization. It provides a comprehensive overview of the state-of-the-art technologies, categorizes recent advancements in algorithm design, and discusses practical considerations for implementation, and serves as an informative resource on current research. Future research directions include developing robust hybrid frameworks, advancing qubit-efficient formulations, and scaling up experimental demonstrations to confirm the theoretical advantages of quantum methods in large-scale power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Grid Interactive Micro-Distributed Display Case

The goal of this project is to design, fabricate and validate the performance of an economically viable next-generation self-contained, refrigerated open vertical display case with integrated thermal storage that improves energy efficiency, enhances demand flexibility, uses an environmentally friendly refrigerant, improves human comfort

25 ENERGY STORAGE↗

Maximizing the Benefits of On-Site Renewable Energy Generation Using On-Site Energy Storage

The commercial and industrial building sectors have a major role to play in a U.S. low-carbon future. Building owners can make a difference by deploying on-site renewable generation and storage technologies, which facilitates future-proofing their buildings as well as more effectively meeting the service requirements of the building. This resource provides an overview of common generation, storage, and load management technologies in behind-the-meter systems, and serves as a primer to demonstrate the impact on net building loads required from the grid for different sizes of renewable generation along with on-site electrical and thermal storage. These discussions can help commercial building owners communicate the value of these systems to project teams and develop innovative behind-the-meter solutions to achieve their energy goals.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Grid-Forming PV Inverter: Technology Development and Microgrid Applications

Presently, excluding residential backup power applications, grid-forming (GFM) inverters are commercially available for battery energy storage system (BESS) and some PV plus battery systems but not yet for stand-alone PV. This tech update investigates the control design for GFM PV inverter, especially the control required to provide active power reserve and to stabilize the dc link voltage. Subsequently, the use cases of GFM PV plants in utility-level microgrids are discussed considering fully inverter-based microgrids (i.e., with PV and BESS) as well as mixed-source microgrids (i.e., with PV and diesel generator). Scenarios where active power up-reserve from GFM PV plants is beneficial are illustrated. Moreover, requirements and specifications for GFM PV plant, especially for its active power reserve function are developed. In addition, stability of an example utility-level microgrid with two GFM PV plants and a diesel generator is analyzed to shed light on the potential unstable interaction between multiple GFM resources and the countermeasures. This research aims to advance GFM PV technology to offer more flexibility in microgrid design. With GFM PV available, depending on the level of reliability required, cost-benefit analysis, etc., the GFM BESS or diesel generator may be sized smaller while leveraging the full potential of PV generation inside the microgrid.

14 SOLAR ENERGY↗

Grid connection barriers to renewable energy deployment in the United States

Bulk-power grid connection is an emerging bottleneck to the entry of wind, solar, and storage but has been understudied due to a lack of data. We create and analyze two novel interconnection datasets with more than 38,000 project-level observations that provide new information documenting interconnection challenges in the United States. Active grid connection requests are more than double the total installed capacity of the US power plant fleet (2,600 vs. 1,280 GW). The time required to secure a connection has increased by 70% over the last decade, and withdrawal rates remain high at 80%, suggesting a constrained transmission system that jeopardizes energy transition targets. Wide distributions of interconnection costs indicate the inherent uncertainty of the interconnection process. Interconnection requests that identify large transmission upgrades tend to withdraw from the process. These findings suggest the need for interconnection reforms, tighter links between long-term transmission planning and project-level interconnection processes, and more interconnection outcome transparency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A 75 kVA Intelligent Power Stages (IPS) Unit Design for Future Grid-interface Application

The demand for grid-interface converter with flexible dc bus is driven by the fast development of energy storage system (ESS), electric vehicle (EV) charging system, and versatile residential load. This paper first proposes a two-stage intelligent power stage (IPS) unit for future grid-interface applications. To achieve zero common-mode (CM) voltage emissions, step-up and step-down voltage gain, a 3-level four-switch buck-boost (3-L FSBB) dc-dc converter is adopted with fully zero voltage switching (ZVS). In one IPS unit, an advanced fiberoptic communication with sub-nanosecond synchronization is developed for different enhanced gate drivers. Moreover, an enhanced gate driver integrated current and voltage sensors is designed for monitoring and diagnostics. To achieve a whole low-profile design, three 12 oz heavy copper planar ac inductors are designed and implemented. Finally, a 75 kVA IPS unit was built to verify both the thermal and electrical design.

Cao, Yuliang↗

Dynamic and Responsive Distributed Energy Resource Education Solutions for Building, Fire, and Safety Department Officials (Final Technical Report)

From April 2021 through March 2024, the Interstate Renewable Energy Council (IREC) led a collaborative project to develop a free online clearinghouse of educational resources about solar photovoltaics (PV), energy storage systems (ESS), electric vehicle supply equipment (EVSE), and grid-interactive efficient building (GEB) technologies. Two websites—the Clean Energy Clearinghouse and CleanEnergyTraining.org—housed over 70 educational resources. Over the course of the three-year project, 154,272 unique visitors accessed the learning materials. Learner feedback was overwhelmingly positive. Even through the end of the project, there was sustained demand for education and communication. A primary innovation of the project was to drive multiple complementary audiences to the same place. Building owners, designers, installation contractors and developers, authorities having jurisdiction (AHJs), and fire service personnel all benefit from a shared understanding of clean energy technologies, including safety and code-related requirements. When considering the impact on the target audience, the project team worked with partners and advisors to inform resource creation and delivery in such a way as to address key motivational factors of the target audience and compel each user to seek additional information on the topic and return to the Clean Energy Clearinghouse website as their central location for more information. Resources were intentionally developed to be concise—five to 15 minutes—and accessible, meaning not overly technical. Providing basic information demystified the technologies and invited the professional to explore additional learning opportunities. Awardee and partner collaboration was key to project success. IREC facilitated collaboration among the other Topic 2 awardees, Southface and New Buildings Institute (NBI). The three awardees shared relevant information gained through discovery and validation questionnaires that informed product development and reduced duplication of effort by coordinating the development of complementary, and not competing, educational resources. Inspired by this collaboration, IREC brought on additional partners even in the final year of the project. Five regional energy efficiency organizations were part of the project, which expanded the connection between efficiency and distributed energy resources. We also included resources on the Clearinghouse that were developed through other federally funded projects, such as the Buildings Energy Efficiency Frontiers & Innovation Technologies (BENEFIT) program. The website was developed with the learner in mind, and not solely the funding source. Feedback from stakeholders throughout the project, and especially in its final year, indicated the need for continued education and facilitated communication among stakeholders to further the safe and widespread adoption of clean energy.

14 SOLAR ENERGY↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Supercritical CO2 Heat Pumps and Power Cycles for Concentrating Solar Power

Pumped Thermal Energy Storage (PTES) is a promising technology for electricity storage applications. An electrically driven heat pump moves energy from a cold space to a hot space, thereby creating hot and cold thermal storage. The temperature difference between the hot and cold storage is later used to drive a heat engine and return electricity to the grid. In this article, supercritical carbon dioxide (sCO2) is chosen as the working fluid for PTES, and results are compared to 'conventional' systems that use nitrogen. Molten salts are used for the hot storage which means that a CSP plant with thermal storage and an sCO2 power cycle could potentially be hybridized with PTES by the addition of a heat pump. This article describes some of the benefits of this combined system which can provide renewable power generation and energy management services. Two methods by which an sCO2 heat pump can be combined with an sCO2 power cycle for CSP are described and techno-economic results are presented. Results indicate that these systems can achieve reasonable technical performance, but that costs are currently high.

carnot battery↗