Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

On the effectiveness of neural operators at zero-shot weather downscaling

Machine-learning (ML) methods have shown great potential for weather downscaling. These data-driven approaches provide a more efficient alternative for producing high-resolution weather datasets and forecasts compared to physics-based numerical simulations. Neural operators, which learn solution operators for a family of partial differential equations, have shown great success in scientific ML applications involving physics-driven datasets. Neural operators are grid-resolution-invariant and are often evaluated on higher grid resolutions than they are trained on, i.e., zero-shot super-resolution. Given their promising zero-shot super-resolution performance on dynamical systems emulation, we present a critical investigation of their zero-shot weather downscaling capabilities, which is when models are tasked with producing high-resolution outputs using higher upsampling factors than are seen during training. To this end, we create two realistic downscaling experiments with challenging upsampling factors (e.g., 8x and 15x) across data from different simulations: the European Centre for Medium-Range Weather Forecasts Reanalysis version 5 (ERA5) and the Wind Integration National Dataset Toolkit. While neural operator-based downscaling models perform better than interpolation and a simple convolutional baseline, we show the surprising performance of an approach that combines a powerful transformer-based model with parameter-free interpolation at zero-shot weather downscaling. We find that this Swin-Transformer-based approach mostly outperforms models with neural operator layers in terms of average error metrics, whereas an Enhanced Super-Resolution Generative Adversarial Network-based approach is better than most models in terms of capturing the physics of the ground truth data. We suggest their use in future work as strong baselines.

17 WIND ENERGY↗

Deep learning model to detect various synchrophasor data anomalies

High-density synchrophasors provide valuable information for power grid situational awareness, operation and control. Unfortunately, due to factors including communication instability and hardware failure, their data quality can be greatly deteriorated by anomalies. Since the anomalies can impact the performance of the synchrophasor applications, it is of paramount significance to propose a model to detect anomalies in synchrophasor. In this study, a convolutional neural network model is established to detect and classify the anomalies in the synchrophasor measurements. Additionally, four types of anomalies observed in actual synchrophasors including erroneous patterns, random spikes, missing points and high-frequency interferences are considered in this study. The proposed model is extensively evaluated via field-collected measurements from the synchrophasor network in Jiangsu grid, China. The superior performance of the proposed model indicates the great potential of using deep learning for the detection of abnormal synchrophasor measurements.

42 ENGINEERING↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Analysis of Post Attack Impacts and Effects of Learning Parameters on Vulnerability Assessment of Power Grid

Due to the increasing number of heterogeneous devices connected to electric power grid, the attack surface increases the threat actors. Game theory and machine learning are being used to study the power system failures caused by external manipulation. Most of existing works in the literature focus on one-shot process of attacks and fail to show the dynamic evolution of the defense strategy. In this paper, we focus on an adversarial multistage sequential game between the adversaries of the smart electric power transmission and distribution system. We study the impact of exploration rate and convergence of the attack strategies (sequences of action that creates large scale blackout based on the system capacity) based on the reinforcement learning approach. We also illustrate how the learned attack actions disrupt the normal operation of the grid by creating transmission line outages, bus voltage violations, and generation loss. This simulation studies are conducted on IEEE 9 and 39 bus systems. The results show the improvement of the defense strategy through the learning process. The results also prove the feasibility of the learned attack actions by replicating the disturbances created in simulated power system.

attack impacts↗

Backup Power Performance of Solar-plus-Storage Systems during Routine Power Interruptions: A Case Study Application of Berkeley Lab’s PRESTO Model

This technical brief estimates the expected performance of a solar photovoltaic and energy storage system (PVESS) for providing backup power during short-duration power interruption events, accounting for the unpredictable nature of those events. The analysis relies on the Power Reliability Event Simulation TOol (PRESTO), a publicly available model developed by Berkeley Lab to simulate the occurrence of short-duration power interruption events at the county-level. A separate storage dispatch model is then used to simulate PVESS operation and backup performance for each of the large number of interruption events produced by PRESTO. In performing this simulation, the analysis accounts for how the customer operates its battery on a day-to-day basis—in this case, we assume the battery is cycled each day in response to time-of-use rates—and how that, in turn, impacts the battery’s state of charge at the beginning of each interruption event. The analysis presented here is intended to demonstrate an application of the PRESTO model as well as to illustrate some of the key determinants of PVESS backup power performance during short-duration power interruption events. The analysis focuses initially on a typical single-family home in Maricopa County, Arizona, and includes a limited set of scenarios related to system sizing, backup power configuration, and whether the customer charges its battery storage system from the grid during normal operating conditions. The analysis also presents comparative results for two other counties, in Massachusetts (Middlesex) and California (Los Angeles), illustrating how regional differences in climate, interruption patterns, and retail rate structures can affect PVESS performance as a backup power source. In the conclusions, we highlight a number of other important considerations for evaluating PVESS backup power capabilities.

14 SOLAR ENERGY↗

Durability tests of a five centimeter diameter ion thruster system

A modified Hughes SIT-5 system is being tested for durability at the Lewis Research Center. As of October 1, 1972, the thruster subsystem has logged over 8000 hours of operation. The initial 2023 hours were run with a translating screen thrust vector grid. The thruster is currently operating with an electrostatic type vector grid. Profiles and maps taken at widely separated intervals show that performance and operating characteristics have remained essentially constant. Overall efficiency is about 32 percent and power to thrust ratio is 170 watts per millipound at a specific impulse of 2500 seconds. Telescopic examination of the vector grid shows some sputtering erosion due to charge exchange and direct impingement ions.

Nakanishi, S.↗

Multifold Insights for Power System Dynamics From Data Assimilation: Meeting Current Challenges

The world’s electric power grids have evolved over the last 120 years from a single power line to today’s large networks. The evolution will continue at an accelerated rate with extensive smart grid development worldwide. Here for example, the U.S. government has set a goal of reaching 100 percent carbon pollution-free electricity by 2035, while the Department of Energy (DOE) shared a goal to deploy 30 GW and 110 GW of offshore wind by 2030 and 2050, respectively. To meet such ambitious goals, in the years to come, a significant percentage of electricity will come from intermittent renewable sources, electric vehicles (EVs), and be supplied to a vast number of loads that will actively respond to grid conditions and incentive signals. This development is largely driven by environmental and economic factors, such as reducing carbon emissions and saving electricity cost for consumers. These energy resources lead to new uncertain behaviors and dynamics which the grid has never seen and were not considered in its design. Operating such a dynamic grid with sufficient reliability and efficiency is a monumental challenge.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMT data generation

The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.

Xia, Qianxue↗

Hydropower Flexibility and Environmental Tradeoffs Analysis

The importance of hydropower increases as the power grid evolves with the higher variable renewable contribution. As conventional thermal power plants are retired, the importance of hydropower contribution increases to balance the variability of solar and wind generation. However, reservoir water resources are constrained by multiple constraints, and variability of water inflow to the reservoirs creates limitations to dam water releases for power grid needs. Coordinating multiple tools, including water resources, ecological, and technical and economic power grid modeling, informs dam water releases. The case study, the Columbia River Basin multipurpose reservoir project, is operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. We integrated a production cost model, a water resource model, and decades of tribal knowledge to analyze the fish-friendly way of operating Columbia hydropower scheduling and grid impacts. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

Columbia River↗

Vulnerability Studies Under EMP: Impedance and PCI Testing of the Grid Control Devices

Control devices such as inverters and generator controllers are critical for the stable operation of the power grid, especially for power stability control and power dispatch. However, the Electromagnetic Pulse (EMP) is a potential threat to electronic devices in modern power grids, therefore decreasing the power grid resilience and bringing unrecoverable damages to the devices. To reveal the impact mechanism of the EMP, impedance and Pulse Current Injection (PCI) testing is established to study the vulnerability of the grid control devices. The impedance of the grid control devices is accurately measured using impedance analyzers with different frequency ranges. Then the voltage and current responses are tested based on the PCI testing. The vulnerability experiments based on two grid control devices are carried out. And the comparison results reveal that most ports would be damaged under EC8, and some ports can survive under EC5 according to the calculated PCI response and cumulative energy. The results can provide a reference for the future design of control devices and the strategic resilience of power grids.

Qiu, Wei↗

Explained: Maintaining a Reliable Future Grid with More Wind and Solar

Since the early 2000s, maintaining grid reliability has become more complex due to a variety of factors, including the changing generation mix, the creation of wholesale energy markets, and a growing number of extreme weather events. Parts of the U.S. grid are already operating with significant amounts of wind and solar generation - with 2022 annual wind and solar generation in the range of 25% to 40%. Even without considering the effects of extreme weather, maintaining reliability will require new capacity to address both growth in electric demand and retiring capacity. Based on the 2022 North American Electric Reliability Corporation (NERC) Long-Term Reliability Assessment, the combination of both growth in peak demand and retirements suggests a need for more than 100 gigawatts (GW) of new capacity by 2032. In general, there are a five categories of resources that are expected to be deployed and used to meet the challenge of maintaining an adequate source of supply in the coming decades: new wind and solar resources (accounting for their reliability contributions), energy storage, demand response resources, expanded transmission, and continued use of thermal generators.

power grid↗

Data-Driven Mean-Corrected Recursive Estimation-Based Optimal DER Dispatch for Distribution System Voltage Control

Recent advances in smart inverters offer opportunities to mitigate adverse grid impacts caused by high penetrations of distributed photovoltaics (PV) in distribution grids, such as voltage violations. Here, this paper proposes a novel measurement-driven optimal power flow (OPF)-based distributed energy resource management system (DERMS) voltage regulation via recursive sensitivity estimation informed coordinated control of distributed PV inverters. The proposed approach leverages available grid and controllable DER measurements, eliminating reliance on system model information while being adaptive and robust to volatile operating conditions. A mean-corrected recursive ridge regression (MCRRR) algorithm is proposed for sensitivity estimation, continuously refining the sensitivity model through a closed-form solution. It effectively manages varying grid operating conditions, such as changes in power injections and topology reconfiguration, to facilitate a time-varying update of the Load Sensitivity Factors (LSF). The proposed approach is formulated as a linear programming (LP) problem and is thus scalable to larger-scale distribution systems. Its effectiveness and efficiency are demonstrated on a realistic distribution feeder with high PV penetrations in Southern California, USA.

14 SOLAR ENERGY↗

Customer enrollment and participation in building demand management programs: A review of key factors

Increasing the efficiency and flexibility of electricity demand is necessary for ensuring a cost-effective and reliable transition to zero-carbon electricity systems. Such demand-side management (DSM) resources have been procured by utilities for decades via energy efficiency and demand response programs; however, the key drivers of program enrollment and customer participation levels remain poorly understood — even as governments and grid planners seek to scale up the deployment of DSM assets to meet climate targets. Here we systematically review the evidence on multiple factors that may influence customer enrollment and participation in building DSM programs, focusing primarily on residential and commercial buildings. We examine the contexts in which relationships between DSM factors and outcomes are most often explored and with which methods; we also score the strength, direction, and internal consistency of each factor's reported impact on the enrollment and participation outcomes. We find that studies most commonly assess the effects of economic incentives for load flexibility on program participation levels, often using simulation-based methods in lieu of measured data. Few studies focus on program enrollment outcomes or regulatory drivers of either enrollment or participation, and gaps are also evident in the coverage of emerging DSM opportunities like load electrification. Removal of structural barriers (e.g., the lack of controls infrastructure) and the use of third party services (e.g., load aggregators) are the factors with the largest positive impacts on DSM outcomes, but no single factor emerges as clearly most impactful. For a given factor, the range of reported impacts typically varies widely across the relevant studies reviewed. Our findings provide a snapshot of the state of knowledge about building DSM and customer decision-making, and they expose key gaps in understanding that must be filled if building DSM is to expand as a critical resource for operating clean power grids.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operator Insights and Usability Evaluation of Machine Learning Assistance for Power Grid Contingency Analysis

Introducing machine learning (ML) assistance into any established process comes with adoption barriers, including entrenched procedures, technological and human readiness levels, human-machine trust, and work culture resistance to change. These barriers are even greater in critical operations such as operating a national or regional power grid, in which both regulatory frameworks and the importance of maintaining reliability levels causes additional resistance to the adoption of new computational support. Developers of future systems and job aides must consider not only technical aspects, but also whether new systems are usable by power system operators. This work presents the methodology and results of a study to evaluate the usability and readiness of a prototype recommender system for power grid contingency analysis. We explore operator cognitive load and evaluate operator performance when solving a collection of scenarios both with and without recommender assistance. We also examine operator trust in the system. We report insights gained on the readiness of the system using a collection of evaluation techniques.

Human-Machine Teaming, Power Systems, usability ev↗

Third-Party Aggregation Rulemaking in MISO and SPP Footprints

The report highlights key considerations for retail regulators in the footprints of the Southwest Power Pool (SPP) or Midcontinent Independent System Operator (MISO) in states that previously opted out of allowing third-party aggregation participation under FERC Order 719 and that may want to explore reversing the decision due to a changing policy environment under new FERC orders (i.e., 2222) and/or tightening resource adequacy constraints. Through a document review and a series of 27 interviews with regulators, aggregators, and other industry professionals, this document provides a high-level policy overview of the retail regulator’s role in a selection of processes, rules, and regulations to better understand how states have treated and/or integrated aggregators into wholesale markets. The report summarizes findings in two sections: General Findings and Specific Policy Findings. The General Findings offer high level takeaways such as the fact that 17 of the 20 states in MISO and SPP footprints opted out of third party aggregations following Order 719. Additionally, there is only one state that is fully restructured in the MISO and SPP footprints whereas the rest are vertically integrated, and the majority of third-party aggregations in the U.S. take place in restructured states outside of these footprints. Even so, third-party aggregations do take place in MISO and SPP albeit in small numbers and in an ad hoc regulatory environment. The specific policy findings delve deeper into specific examples of state actions on the topics of jurisdiction, registration and licensing, data governance, dual participation, and dispute resolution. Tables in each category organize state actions into Tiers I-III, which roughly correspond to the possible level of involvement or possible change necessary by state regulators and/or legislators to implement these actions. The tier level does not indicate any value judgement, as each state has respective regulatory limitations and each decision comes with various tradeoffs. One main tradeoff is between simplicity and quick implementation versus comprehensive and prolonged implementation. In many cases, actions in Tier I could be implemented without significant changes by relying on the use of existing processes for an aggregator context. On the other hand, many actions in Tier III are more narrowly designed to address aggregators specifically, but often require more significant changes including the involvement of additional parties through stakeholder engagement or legislative action. In some cases, these tiers are discrete. However, state regulators may also choose to progress through these various tiers sequentially as they phase in aggregators while learning from their experience. With the ability to stack bulk system level services, distributed energy resource aggregations in MISO and SPP could provide various private benefits (e.g., increased value streams to the owner) as well as societally beneficial grid services (e.g., peaking capacity, ancillary services, and other services that increase the grid’s overall operational efficiency). In deciding how to best to enable these benefits, states and retail regulators must weigh various tradeoffs if considering reversing a previous opt out.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Storage and the Law of Averages: How Storage Can Make Electricity More Affordable

The electric grid is planned, built, and operated to satisfy peak demand. But because peak demand only occurs for a few hours per year, customers end up paying full price for grid infrastructure that is only used for a small fraction of the year—an increasingly expensive proposition as peak demand continues to grow and more infrastructure is required to meet it. The emergence of cost-competitive energy storage technologies in recent years, however, offers the potential for a grid that is planned, built, and operated based on average demand. By strategically siting and operating energy storage throughout the electric grid, excess generation in low-demand periods can be captured and stored near customers, which then reduces the amount of electricity that needs to be generated and moved through the transmission and distribution systems during high-demand periods. This paper describes these potential benefits, supported by real-world examples of energy storage projects that have created cost savings, which points to the potential for profound and far-reaching reductions in the cost of electricity if energy storage technologies are deployed at scale throughout the electric grid. These examples will be of use to system planners and operators, utility regulators, decision makers, and stakeholders in those processes as they look for opportunities to reduce the cost of electricity in their respective systems and jurisdictions.

25 ENERGY STORAGE↗

Optimal Padding for the Two-Dimensional Fast Fourier Transform

One-dimensional Fast Fourier Transform (FFT) operations work fastest on grids whose size is divisible by a power of two. Because of this, padding grids (that are not already sized to a power of two) so that their size is the next highest power of two can speed up operations. While this works well for one-dimensional grids, it does not work well for two-dimensional grids. For a two-dimensional grid, there are certain pad sizes that work better than others. Therefore, the need exists to generalize a strategy for determining optimal pad sizes. There are three steps in the FFT algorithm. The first is to perform a one-dimensional transform on each row in the grid. The second step is to transpose the resulting matrix. The third step is to perform a one-dimensional transform on each row in the resulting grid. Steps one and three both benefit from padding the row to the next highest power of two, but the second step needs a novel approach. An algorithm was developed that struck a balance between optimizing the grid pad size with prime factors that are small (which are optimal for one-dimensional operations), and with prime factors that are large (which are optimal for two-dimensional operations). This algorithm optimizes based on average run times, and is not fine-tuned for any specific application. It increases the amount of times that processor-requested data is found in the set-associative processor cache. Cache retrievals are 4-10 times faster than conventional memory retrievals. The tested implementation of the algorithm resulted in faster execution times on all platforms tested, but with varying sized grids. This is because various computer architectures process commands differently. The test grid was 512 512. Using a 540 540 grid on a Pentium V processor, the code ran 30 percent faster. On a PowerPC, a 256x256 grid worked best. A Core2Duo computer preferred either a 1040x1040 (15 percent faster) or a 1008x1008 (30 percent faster) grid. There are many industries that can benefit from this algorithm, including optics, image-processing, signal-processing, and engineering applications.

Dean, Bruce H.↗

Reconfiguration of power grids during abnormal conditions using reclosers and distributed energy resources

Apparatus and methods are disclosed for restoring operation of a power grid comprising a plurality of reclosers and distributed energy resources (DERs) responsive to abnormal conditions by determining and implementing a reconfiguration for the power grid. The reconfiguration can specify respective new statuses for one or more of the reclosers and/or respective quantities of reactive power to be supplied by one or more of the DERs. The reconfiguration can be determined based on a plurality of constraints using an objective function, the constraints being determined based at least in part on recloser status data and/or DER power generation capability data. Respective cleared quantities of reactive power for the DERs to supply to the reconfigured power grid can be determined via a transactive control scheme, and the reconfiguration can be updated prior to implementation based on the results of the transactive control scheme.

Radhakrishnan, Nikitha↗