Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Giant Exfoliation Induced Magnetic Coercivity in Fe 3 GaTe 2

Permanent magnets with strong anisotropy and high coercivity underpin modern information and energy technologies, yet rare-earth-free alternatives remain limited. Here, we show that thickness engineering via mechanical exfoliation induces hard magnetic behavior in the van der Waals ferromagnet Fe 3 GaTe 2 . Bulk crystals exhibit Curie temperatures above 350 K but negligible room-temperature coercivity. When thinned below ∼100 nm, the coercive field is dramatically enhanced, reaching nearly 1 T at room temperature for in-plane fields—comparable to conventional hard magnets. Micromagnetic analysis reveals a crossover in magnetization reversal from domain-mediated processes in bulk samples to quasi-coherent rotation in thin flakes, driven by increased effective anisotropy and suppressed domain formation. This thickness-dependent transition enables tuning of magnetic hardness without chemical modification. Combined with high saturation magnetization and robust room-temperature performance, Fe 3 GaTe 2 emerges as a promising rare-earth-free material for spintronic applications. Its layered structure further allows integration into van der Waals heterostructures, where large in-plane coercivity can stabilize magnetic states against perturbations and interlayer coupling, offering potential for high-density nonvolatile memory and domain-wall-based devices.

36 MATERIALS SCIENCE↗

Self‐gated, dynamic contrast‐enhanced magnetic resonance imaging with compressed‐sensing reconstruction for evaluating endothelial permeability in the aortic root of atherosclerotic mice

High‐risk atherosclerotic plaques are characterized by active inflammation and abundant leaky microvessels. We present a self‐gated, dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) acquisition with compressed sensing reconstruction and apply it to assess longitudinal changes in endothelial permeability in the aortic root of Apoe −/− atherosclerotic mice during natural disease progression. Twenty‐four, 8‐week‐old, female Apoe −/− mice were divided into four groups (n = 6 each) and imaged with self‐gated DCE‐MRI at 4, 8, 12, and 16 weeks after high‐fat diet initiation, and then euthanized for CD68 immunohistochemistry for macrophages. Eight additional mice were kept on a high‐fat diet and imaged longitudinally at the same time points. Aortic‐root pseudo‐concentration curves were analyzed using a validated piecewise linear model. Contrast agent wash‐in and washout slopes ( b 1 and b 2 ) were measured as surrogates of aortic root endothelial permeability and compared with macrophage density by immunohistochemistry. b 2 , indicating contrast agent washout, was significantly higher in mice kept on an high‐fat diet for longer periods of time ( p = 0.03). Group comparison revealed significant differences between mice on a high‐fat diet for 4 versus 16 weeks ( p = 0.03). Macrophage density also significantly increased with diet duration ( p = 0.009). Spearman correlation between b 2 from DCE‐MRI and macrophage density indicated a weak relationship between the two parameters (r = 0.28, p = 0.20). Validated piecewise linear modeling of the DCE‐MRI data showed that the aortic root contrast agent washout rate is significantly different during disease progression. Further development of this technique from a single‐slice to a 3D acquisition may enable better investigation of the relationship between in vivo imaging of endothelial permeability and atherosclerotic plaques' genetic, molecular, and cellular makeup in this important model of disease.

Calcagno, Claudia↗

Physical Modeling and Design of a Nonvolatile Optically Gated High‐Power Diamond Transistor

In this work, we present the theory and modeling framework of a diamond optically gated junction field‐effect transistor (DOGFET). The device utilizes nitrogen substitutional centers in type‐1b diamond to optically modulate a p‐ boron doped diamond channel. Using sub‐gap lasers with intensities as low as 100 W/cm 2 , electrons are optically excited from substitutional nitrogen sites to the conduction band of the diamond substrate, thus enabling the optical gate to exercise control on modulating the space‐charge region at the junction and therefore the channel conductivity. We show that the device can deliver a current of 7 μA/μm, or equivalently 1750 A/cm 2 , while switching at a frequency greater than 100 kHz, in a form factor of 5 μm 2 . The breakdown voltage is found to be greater than 1850 V, with a breakdown field strength of ~13 MV/cm. Moreover, the device supports nonvolatile operation with a “memory effect” enabling single transistor state retention. The presented simulation framework provides a physically grounded insight into the limits and opportunities of optoelectronic diamond systems.

Engineering - Electronic and electrical engineerin↗

Autonomous Magnetic Microrobots by Navigating Gates for Multiple Biomolecules Delivery

The precise delivery of biofunctionalized matters is of great interest from the fundamental and applied viewpoints. In spite of significant progress achieved during the last decade, a parallel and automated isolation and manipulation of rare analyte, and their simultaneous on-chip separation and trapping, still remain challenging. In this work, a universal micromagnet junction for self-navigating gates of microrobotic particles to deliver the biomolecules to specific sites using a remote magnetic field is described. In the proposed concept, the nonmagnetic gap between the lithographically defined donor and acceptor micromagnets creates a crucial energy barrier to restrict particle gating. It is shown that by carefully designing the geometry of the junctions, it becomes possible to deliver multiple protein-functionalized carriers in high resolution, as well as MCF-7 and THP-1 cells from the mixture, with high fidelity and trap them in individual apartments. Integration of such junctions with magnetophoretic circuitry elements could lead to novel platforms without retrieving for the synchronous digital manipulation of particles/biomolecules in microfluidic multiplex arrays for next-generation biochips.

36 MATERIALS SCIENCE↗

Two-photon absorption in quantum dot semiconductor optical amplifiers-based all-optical XOR gate at 2 Tb/s

The nonlinear effect of two-photon absorption (TPA) on the performance of all-optical XOR gate using quantum dot semiconductor optical amplifiers (QDSOAs)-assisted Mach–Zehnder interferometer is numerically analyzed and investigated at a data rate of 2 Tb/s. The dependence of the quality factor (QF) on the critical parameters of the input signal and QDSOA is examined and assessed. The obtained QFs for the all-optical XOR gate using QDSOAs-MZI at 2 Tb/s with TPA and without TPA are 14 and 8, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gating System Design Optimization for Investment Casting Process

This article aims to optimize specific castings, characterized as an element of the continuous track for armored vehicle. During the primary melts, defects in the form of oxide films and shrinkage porosity occurred. Steel 20ChGSNM described by the Russian GOST standard was used as a batch material, and the investment casting method was selected for production. To eliminate the above-mentioned defects, only changes in the gating system were allowed, because the interference with an ongoing production regarding technical and technological parameters was unacceptable by the manufacturer. Numerical simulation, x-ray, macro-structural and micro-structural analysis were used during the optimization process. The three variants were analyzed, and the achieved results demonstrated that it is possible to significantly affect the casting internal homogeneity by modifying the gating system individual parts. The final variant ensured a decrease in defects by up to 90% and the production of casting having the quality required by the customer.

36 MATERIALS SCIENCE↗

Assessment of left ventricular contraction patterns using gated SPECT MPI to predict cardiac resynchronization therapy response

Background: The U-shaped left ventricular (LV) contraction pattern, identified by MRI or echocardiography, is associated with improved CRT response. Gated SPECT MPI can measure both myocardial viability and mechanical dyssynchrony in a single scan. The aim of this study is to examine the relationship of the LV contraction pattern and the response of CRT in patients with left bundle branch block (LBBB). Methods: Fifty-eight patients who met CRT guidelines and who had pre-CRT MPI were enrolled. Myocardial segments with tracer uptake < 50% of maximum were considered as scar. The LV contraction pattern was considered as U-shaped or non-U-shaped (U-shaped has a block line in the direction of contraction propagation). CRT response was defined as an increase in left ventricular ejection fraction ≥ 5% after 6-month follow-up. Results: Twenty-eight patients (48%) had a U-shaped contraction pattern and thirty patients (52%) had a non-U-shaped contraction pattern. The U-shaped group showed a significantly higher response rate than the non-U-shaped group (90% vs. 57%; P = 0.005). By univariate and multivariate logistic regression analysis, the U-shaped pattern was an independent predictor of CRT response. Conclusion: Non-invasive gated SPECT MPI can characterize LV mechanical contraction patterns. A U-shaped contraction pattern identified is associated with improved CRT response. This may prove useful for improved patient selection for CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Added prognostic value of left ventricular shape by gated SPECT imaging in patients with suspected coronary artery disease and normal myocardial perfusion

Background: Left ventricular (LV) remodeling is associated with adverse cardiovascular events. We evaluated the added prognostic value of LV shape index (SI) assessed by gated single-photon emission tomography (SPECT) in patients without known coronary artery disease (CAD). Methods and results: We studied 674 patients with normal myocardial perfusion and normal LV ejection fraction (EF) on stress gated SPECT imaging. An automated software program was used to calculate end-diastolic and end-systolic LVSI. An LVSI ≤ 0.54 at end-systole was considered normal. Follow-up was 96% complete with a median follow-up of 37 months. During follow-up, 25 events occurred (3.8% cumulative event rate). Event-free survival was lower in patients with abnormal end-systolic LVSI (P < .001). Age (P = .021), diabetes (P = .048), and end-systolic LVSI (P < .001) were independent predictors of events. LVSI added prognostic information increasing the global chi-square of the model including age and diabetes from 15.15 to 25.97 (P < .001). The effect of diabetes on hazard ratio increased with increasing values of end-systolic LVSI. The probability of events at 48 months predicted by Weibull analysis progressively increased with increasing values of end-systolic LVSI and was higher in patients with diabetes as compared to those without. Decision curve analyses indicate that the model including end-systolic LVSI resulted in an increased net benefit between 5% and 30% threshold probability, indicating superior estimation of outcomes at low threshold probability levels. Conclusions: The evaluation of LVSI may identify patients with early-stage LV remodeling and at higher risk of adverse cardiac events, even in the presence of normal myocardial perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gated SPECT myocardial perfusion imaging with cadmium-zinc-telluride detectors allows real-time assessment of dobutamine-stress-induced wall motion abnormalities

Background: Left ventricular (LV) ejection fraction (EF) during high dobutamine stress (HD) by real-time gated-SPECT myocardial perfusion imaging (MPI) on a cadmium-zinc-telluride (CZT) gamma camera was validated versus cardiac magnetic resonance imaging (CMR). Methods and results: After injecting 99mTc-tetrofosmin (320 MBq) in 50 patients (mean age 64 +/− 11 years), EF at rest and post-stress as well as relevant changes in EF at HD (ΔEF ≥ 5%) were assessed. CZT and CMR rest EF values yielded an excellent correlation and agreement (r = 0.96; P < 0.001; Bland–Altman limits of agreement (BA): + 0 to 14.8%). HD EF acquisition was feasible using CZT and correlated better to HD CMR EF than did post-stress CZT EF (r = 0.85 vs 0.76, respectively, all P < 0.001). Agreement in ΔEF detection between HD CMR and immediate post-stress CZT (reflecting standard acquisition using conventional SPECT camera unable to scan during stress) was 45%, while this increased to 85% with real-time HD CZT scan. Conclusion: Real-time ultrafast dobutamine gated-SPECT MPI with a CZT device is feasible and provides accurate measurements of HD LV performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Zn{sup 2+} induces apoptosis in human highly metastatic SHG-44 glioma cells, through inhibiting activity of the voltage-gated proton channel Hv1

Highlights: •Hv1 is expressed in highly metastatic glioma cell. •Zn{sup 2+} ions induces apoptosis in highly metastatic glioma cells. •Zn{sup 2+} ions markedly inhibit proton secretion. •Zn{sup 2+} ions reduce the gelatinase activity. •Inhibition of Hv1 activity via Zn{sup 2+} ions can effectively retard the cancer growth. -- Abstract: In contrast to the voltage-gated K{sup +} channels, the voltage-gated proton channel Hv1 contains a voltage-sensor domain but lacks a pore domain. Here, we showed that Hv1 is expressed in the highly metastatic glioma cell SHG-44, but lowly in the poorly metastatic glioma cell U-251. Inhibition of Hv1 activity by 140 μM zinc chloride induces apoptosis in the human highly metastatic glioma cells. Zn{sup 2+} ions markedly inhibit proton secretion, and reduce the gelatinase activity in the highly metastatic glioma cells. In vivo, the glioma tumor sizes of the implantation of the SHG-44 xenografts in nude mice that were injected zinc chloride solution, were dramatically smaller than that in the controlled groups. The results demonstrated that the inhibition of Hv1 activity via Zn{sup 2+} ions can effectively retard the cancer growth and suppress the cancer metastasis by the decrease of proton extrusion and the down-regulation of gelatinase activity. Our results suggest that Zn{sup 2+} ions may be used as a potential anti-glioma drug for glioma therapy.

60 APPLIED LIFE SCIENCES↗

A single amino acid gates the KcsA channel

Highlights: • pH-dependent gating of the KcsA channel is regulated by the CPD. • E146 is the most essential amino acid for pH sensing by the KcsA. • The protonated-mimicking mutant, E146Q, is constitutively open independent of pH. • Minimal rearrangement of the CPD is sufficient for opening of the KcsA. - Abstract: The KcsA channel is a proton-activated potassium channel. We have previously shown that the cytoplasmic domain (CPD) acts as a pH-sensor, and the charged states of certain negatively charged amino acids in the CPD play an important role in regulating the pH-dependent gating. Here, we demonstrate the KcsA channel is constitutively open independent of pH upon mutating E146 to a neutrally charged amino acid. In addition, we found that rearrangement of the CPD following this mutation was not large. Our results indicate that minimal rearrangement of the CPD, particularly around E146, is sufficient for opening of the KcsA channel.

60 APPLIED LIFE SCIENCES↗

Loop engineering reveals the importance of active-site-decorating loops and gating residue in substrate affinity modulation of arginine deiminase (an anti-tumor enzyme)

Highlights: • Loop engineering on the active-site-decorating loops yielded several PpADI variants with low S{sub 0.5} values. • Several amino acid positions in active-site-decorating loops essential for the substrate affinity of PpADI were identified. • High loop flexibility (especially the gating residue Arg400) is beneficial for the substrate affinity of PpADI. Protein engineering of enzyme loop regions is an effective strategy to improve enzymatic properties. Previous studies that aimed to boost the activity of PpADI (an arginine deiminase from Pseudomonas plecoglossicida) under physiological conditions yielded several significantly improved variants that harbor substitutions predominantly located in active-site-decorating loops. A multi-site saturation mutagenesis at four positions in loop 1 (37, 38, 42, and 43) and three positions in loop 4 (402, 403, and 404) was performed to elucidate the importance of these loops in modulating the substrate affinity of PpADI. The identified “best” variant (M6-L1-4) showed a decreased S{sub 0.5} (‘K{sub M}’) of 0.48 mM compared with the parent M6 (0.81 mM). Subsequently, a rational design to recombine beneficial substitutions within loops 1 and 4 yielded variant L6 with a substantially decreased S{sub 0.5} value (0.17 mM). A comprehensive simulation analysis resulted in a conclusion that high loop flexibility (especially the gating residue Arg400) is beneficial for substrate affinity due to less efficient blocking of the active site.

60 APPLIED LIFE SCIENCES↗

Quality Assurance Challenges for Motion-Adaptive Radiation Therapy: Gating, Breath Holding, and Four-Dimensional Computed Tomography

Compared with conventional three-dimensional (3D) conformal radiation therapy and intensity-modulated radiation therapy treatments, quality assurance (QA) for motion-adaptive radiation therapy involves various challenges because of the added temporal dimension. Here we discuss those challenges for three specific techniques related to motion-adaptive therapy: namely respiratory gating, breath holding, and four-dimensional computed tomography. Similar to the introduction of any other new technologies in clinical practice, typical QA measures should be taken for these techniques also, including initial testing of equipment and clinical procedures, as well as frequent QA examinations during the early stage of implementation. Here, rather than covering every QA aspect in depth, we focus on some major QA challenges. The biggest QA challenge for gating and breath holding is how to ensure treatment accuracy when internal target position is predicted using external surrogates. Recommended QA measures for each component of treatment, including simulation, planning, patient positioning, and treatment delivery and verification, are discussed. For four-dimensional computed tomography, some major QA challenges have also been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory-Gated Helical Computed Tomography of Lung: Reproducibility of Small Volumes in an Ex Vivo Model

Purpose: Motion-adapted radiotherapy with gated irradiation or tracking of tumor positions requires dedicated imaging techniques such as four-dimensional (4D) helical computed tomography (CT) for patient selection and treatment planning. The objective was to evaluate the reproducibility of spatial information for small objects on respiratory-gated 4D helical CT using computer-assisted volumetry of lung nodules in a ventilated ex vivo system. Methods and Materials: Five porcine lungs were inflated inside a chest phantom and prepared with 55 artificial nodules (mean diameter, 8.4 mm {+-} 1.8). The lungs were respirated by a flexible diaphragm and scanned with 40-row detector CT (collimation, 24 x 1.2 mm; pitch, 0.1; rotation time, 1 s; slice thickness, 1.5 mm; increment, 0.8 mm). The 4D-CT scans acquired during respiration (eight per minute) and reconstructed at 0-100% inspiration and equivalent static scans were scored for motion-related artifacts (0 or absent to 3 or relevant). The reproducibility of nodule volumetry (three readers) was assessed using the variation coefficient (VC). Results: The mean volumes from the static and dynamic inspiratory scans were equal (364.9 and 360.8 mm{sup 3}, respectively, p = 0.24). The static and dynamic end-expiratory volumes were slightly greater (371.9 and 369.7 mm{sup 3}, respectively, p = 0.019). The VC for volumetry (static) was 3.1%, with no significant difference between 20 apical and 20 caudal nodules (2.6% and 3.5%, p = 0.25). In dynamic scans, the VC was greater (3.9%, p = 0.004; apical and caudal, 2.6% and 4.9%; p = 0.004), with a significant difference between static and dynamic in the 20 caudal nodules (3.5% and 4.9%, p = 0.015). This was consistent with greater motion-related artifacts and image noise at the diaphragm (p <0.05). The VC for interobserver variability was 0.6%. Conclusion: Residual motion-related artifacts had only minimal influence on volumetry of small solid lesions. This indicates a high reproducibility of spatial information for small objects in low pitch helical 4D-CT reconstructions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic and Pathologic Variability During Radiotherapy for a Hybrid Active Breath-Hold Gating Technique

Purpose: To evaluate intra- and interfraction variability of tumor and lung volume and position using a hybrid active breath-hold gating technique. Methods and Materials: A total of 159 repeat normal inspiration active breath-hold CTs were acquired weekly during radiotherapy for 9 lung cancer patients (12-21 scans per patient). A physician delineated the gross tumor volume (GTV), lungs, and spinal cord on the first breath-hold CT, and contours were propagated semiautomatically. Intra- and interfraction variability of tumor and lung position and volume were evaluated. Tumor centroid and border variability were quantified. Results: On average, intrafraction variability of lung and GTV centroid position was <2.0 mm. Interfraction population variability was 3.6-6.7 mm (systematic) and 3.1-3.9 mm (random) for the GTV centroid and 1.0-3.3 mm (systematic) and 1.5-2.6 mm (random) for the lungs. Tumor volume regressed 44.6% {+-} 23.2%. Gross tumor volume border variability was patient specific and demonstrated anisotropic shape change in some subjects. Interfraction GTV positional variability was associated with tumor volume regression and contralateral lung volume (p < 0.05). Inter-breath-hold reproducibility was unaffected by time point in the treatment course (p > 0.1). Increases in free-breathing tidal volume were associated with increases in breath-hold ipsilateral lung volume (p < 0.05). Conclusions: The breath-hold technique was reproducible within 2 mm during each fraction. Interfraction variability of GTV position and shape was substantial because of tumor volume and breath-hold lung volume change during therapy. These results support the feasibility of a hybrid breath-hold gating technique and suggest that online image guidance would be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Functional Image-Guided Radiotherapy Planning in Respiratory-Gated Intensity-Modulated Radiotherapy for Lung Cancer Patients With Chronic Obstructive Pulmonary Disease

Purpose: To investigate the incorporation of functional lung image-derived low attenuation area (LAA) based on four-dimensional computed tomography (4D-CT) into respiratory-gated intensity-modulated radiotherapy (IMRT) or volumetric modulated arc therapy (VMAT) in treatment planning for lung cancer patients with chronic obstructive pulmonary disease (COPD). Methods and Materials: Eight lung cancer patients with COPD were the subjects of this study. LAA was generated from 4D-CT data sets according to CT values of less than than -860 Hounsfield units (HU) as a threshold. The functional lung image was defined as the area where LAA was excluded from the image of the total lung. Two respiratory-gated radiotherapy plans (70 Gy/35 fractions) were designed and compared in each patient as follows: Plan A was an anatomical IMRT or VMAT plan based on the total lung; Plan F was a functional IMRT or VMAT plan based on the functional lung. Dosimetric parameters (percentage of total lung volume irradiated with {>=}20 Gy [V20], and mean dose of total lung [MLD]) of the two plans were compared. Results: V20 was lower in Plan F than in Plan A (mean 1.5%, p = 0.025 in IMRT, mean 1.6%, p = 0.044 in VMAT) achieved by a reduction in MLD (mean 0.23 Gy, p = 0.083 in IMRT, mean 0.5 Gy, p = 0.042 in VMAT). No differences were noted in target volume coverage and organ-at-risk doses. Conclusions: Functional IGRT planning based on LAA in respiratory-guided IMRT or VMAT appears to be effective in preserving a functional lung in lung cancer patients with COPD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Magnetic Resonance Imaging With 3-Dimensional Radial Sampling and Self-Gating–Based K-Space Sorting: Early Clinical Experience on Pancreatic Cancer Patients

Purpose: To apply a novel self-gating k-space sorted 4-dimensional MRI (SG-KS-4D-MRI) method to overcome limitations due to anisotropic resolution and rebinning artifacts and to monitor pancreatic tumor motion. Methods and Materials: Ten patients were imaged using 4D-CT, cine 2-dimensional MRI (2D-MRI), and the SG-KS-4D-MRI, which is a spoiled gradient recalled echo sequence with 3-dimensional radial-sampling k-space projections and 1-dimensional projection-based self-gating. Tumor volumes were defined on all phases in both 4D-MRI and 4D-CT and then compared. Results: An isotropic resolution of 1.56 mm was achieved in the SG-KS-4D-MRI images, which showed superior soft-tissue contrast to 4D-CT and appeared to be free of stitching artifacts. The tumor motion trajectory cross-correlations (mean ± SD) between SG-KS-4D-MRI and cine 2D-MRI in superior–inferior, anterior–posterior, and medial–lateral directions were 0.93 ± 0.03, 0.83 ± 0.10, and 0.74 ± 0.18, respectively. The tumor motion trajectories cross-correlations between SG-KS-4D-MRI and 4D-CT in superior–inferior, anterior–posterior, and medial–lateral directions were 0.91 ± 0.06, 0.72 ± 0.16, and 0.44 ± 0.24, respectively. The average standard deviation of gross tumor volume calculated from the 10 breathing phases was 0.81 cm{sup 3} and 1.02 cm{sup 3} for SG-KS-4D-MRI and 4D-CT, respectively (P=.012). Conclusions: A novel SG-KS-4D-MRI acquisition method capable of reconstructing rebinning artifact–free, high-resolution 4D-MRI images was used to quantify pancreas tumor motion. The resultant pancreatic tumor motion trajectories agreed well with 2D-cine-MRI and 4D-CT. The pancreatic tumor volumes shown in the different phases for the SG-KS-4D-MRI were statistically significantly more consistent than those in the 4D-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Field-to-farm gate greenhouse gas emissions from corn stover production in the Midwestern U.S.

Measured field data were used to compare two allocation methods on life cycle greenhouse gas emissions from corn (Zea mays L.) stover production in the Midwest U.S. We used publicly-available crop yield, nitrogen fertilizer, and direct soil nitrous oxide emissions data from the USDA-ARS Resilient Economic Agricultural Practices research program. Field data were aggregated from 9 locations across 26 site-years for 3 stover harvest rates (no removal; moderate removal – 3.1 Mg ha –1 ; high removal – 7.2 Mg ha –1 ) and 2 tillage practices (conventional; reduced/no-till). Net carbon uptake by crops was computed from measured plant carbon content. Monte Carlo simulations sampled input distributions to assess variability in farm-to-gate GHG emissions. The base analysis assumed no change in soil organic carbon stocks. In all cases, net CO 2 uptake during crop growth and soil-respired CO 2 dominated system emissions. Emissions were most sensitive to co-product accounting method, with system expansion emissions ~15% lower than mass allocation. Regardless of accounting method, lowest emissions occurred for a moderate removal rate under reduced/no-till management. The absence of correlations between N fertilization rate and stover removal rate or soil N 2 O emissions in this study challenges the use of such assumptions typically employed in life cycle assessments Storage of all carbon retained on the field as SOC could reduce emissions by an additional 15%. Furthermore, our results highlight how variability in GHG emissions due to location and weather can overshadow the impact of farm management practices on field-to-farm gate emissions. Graphical abstract

54 ENVIRONMENTAL SCIENCES↗