Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

An Early Assessment of JPSS-1/NOAA-20 VIIRS Day-Night Band On-Orbit Calibration and Performance

The JPSS-1 (now named NOAA-20) VIIRS instrument has been successfully operating on orbit since November 28th, 2017. The Day-Night Band (DNB) is a panchromatic channel covering wavelengths from 0.5 to 0.9 m that is capable of observing the Earth scene in visible/near-Infrared spectral range at spatial resolution of 750 m. The DNB operates at low, mid, or high radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low gain stage calibration. The SD observations also provide a mean to compute gain ratios between low-to-mid and mid-to-high gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. This paper provides an early assessment of the DNB on-orbit performance and behavior in the first 90-day post launch test (PLT) period and beyond. The calibration methodology used by the VIIRS Characterization Support Team (VCST) in support of the NASA earth science community will be presented. The trending of OBC dark-offsets, SD gains and gain ratios, and signal-to-noise ratio (SNR) at minimum radiance have been analyzed, especially during key events such as the Nadir and Cryo-cooler doors opening. Furthermore, we performed inter-comparison studies between SNPP and JPSS-1 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains and gain ratios, as well as the calibration comparison between the IDPS LUTs and our VCST delivery results.

Chen, H.↗

NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

VIIRS↗

Comparison of Active and Passive Head Impulse Testing of the Horizontal Vestibulo-Ocular Reflex: Exploring the Feasibility of Different Approaches for Spaceflight

INTRODUCTION: Astronauts experience a wide variety of sensorimotor disturbances primarily due to microgravity-induced vestibular adaptations during spaceflight. Head Impulse Testing (HIT) will be conducted during the Complement of Integrated Protocols for Human Exploration Research program(CIPHER) Vestibular Health study to examine changes in the horizontal vestibulo-ocular reflex in response to high-velocity head movements to detect changes in peripheral vestibular function [1,2]. However, correct interpretation will require consideration of potential artifacts and the constraints of conducting this test across different phases of the mission. Therefore, the aims of our study were to (1) examine reliability across different test operators, and (2) compare results of active (aHIT) versus passive (pHIT) approaches to evaluate the feasibility of self-administered versus operator-assisted approaches. A comparison of responses with visual viewing of a wall target (default condition) versus vision occluded evaluated the influence of other oculomotor control influence across conditions, and comparison with computer-generated rotator head impulse tests (rHIT) examined the variability associated with the ocular responses independent of the variability in executing the head movements themselves. METHODS: Seventeen non-astronaut volunteers (male n=12, age=22.9 ± 3.0; female n=5, age=27.0 ± 6.0, mean ± std) completed HIT testing using video-oculography (VOG) goggles and a high-torque rotator system. The test order was counterbalanced across conditions: (1) passive head-on-torso (pHIT, default condition for flight study) using two operators (Op1 and Op2), (2) active head-on-torso (aHIT, subject initiated), and (3) passive head and torso using rotary chair (rHIT). Eye and head movement data were processed to obtain gain in each direction. The main outcome measures were average gain and asymmetry [1], as well as the percentage of acceptable trials not excluded due to insufficient head amplitude or recording artifacts. RESULTS: While the pHIT gains were similar with vision (1.032 ± 0.043) and vision occluded (1.029 ± 0.038) conditions, the percentage of acceptable trials was greater with vision (Op1 = 93.0%, Op2 = 93.2%) versus occluded (Op1 = 70.7%, Op2 = 67.6%). The reliability between operators was greater for pHIT gain (Intraclass Correlation, ICC = 0.66, p = 0.001) than for pHIT asymmetry (ICC = 0.57, p = 0.01). The percentage of acceptable trials reduced by ~20% during the self-administered aHITs for both visual conditions and tended to be lower than computer-generated rHITs (76% versus 83%). While the aHIT gains were not significantly different than pHIT gains for vision or vision occluded conditions, these measures were poorly correlated. Both aHIT and pHIT gains were significantly greater than the rHIT gains, presumably due to the reduced velocities from the rotator. The asymmetry measures were poorly correlated across pHIT, aHIT, and rHIT conditions, although none of the subjects had asymmetries greater than 16%. DISCUSSION: Our findings support the feasibility of using the standard pHIT methodology for spaceflight. Similarities between visual conditions reflect that these responses are mediated by the peripheral lateral canals rather than other oculomotor mechanisms. The inter-tester reliability was acceptable despite differences in the tester training. In addition to concerns of non-vestibular mechanisms introduced during self-administered aHITs [2], operator-assisted pHITs resulted in higher percentage of acceptable trials and should result in more efficient and reliable measures during spaceflight.

M R Ehrenburg↗

Delay-resolved spectroscopy in terahertz photonic circuits

Photonic integrated circuits incorporating intersubband transitions are ideal for mid-infrared and terahertz nanophotonics. However, the design of epitaxies has long been inhibited by two factors: the modest predictivity of ab initio theory and the absence of absolute intersubband gain and loss measurements under operating conditions. Existing measurements either yield inaccurate gain profiles or do not accurately assess dependence on frequency, bias, and temperature. Here, we present a delay-resolved absolute-referencing method for accurate gain evaluation without these limitations, addressing a long-standing challenge. By creating a photonic circuit that allows broadband pulses to traverse different lengths of a gain medium, we measure the absolute transmission of intersubband structures. Gain profiles match theoretical predictions at lower temperatures, with gain and dispersion clamping after lasing, and faster-than-expected degradation occurs at higher temperatures. Our approach provides a precise experimental evaluation of temperature-dependent gain performance and gives insight into optimizing temperature performance and frequency comb designs.

Optical spectroscopy↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and testing of the S-band antenna subsystem for the Mariner Mars 1971 spacecraft

The Mariner Mars 1971 S-band antenna subsystem is used to transmit and receive S-band signals to and from the Deep Space Instrumentation Facility ground stations. The antenna subsystem consists of a low-gain antenna, a medium-gain antenna, a directional coupler, a high-gain antenna, and all transmission lines required to interconnect the antennas to the spacecraft radio frequency subsystem. The low-gain antenna is used to transmit signals during cruise and receive signals throughout the mission. The medium-gain antenna is coupled to the low-gain antenna via the directional coupler and is used to transmit and receive signals during Mars orbit insertion. The high-gain antenna is used to transmit high data rate signals primarily during Mars orbit.

Brejcha, A. G.↗

GaAs dual-gate FET for operation up to K-band

A high-frequency equivalent-circuit model of a GaAs dual-gate FET and analytical expressions for the input/output impedances, transconductance, unilateral gain, and stability factor are presented. It is found that the gain of a dual-gate FET is higher than of a single-gate FET at low frequency but decreases faster as frequency increases because of the capacitive shunting effect of the second gate. A dual-gate power FET suitable for variable-gain-amplifier applications up to K-band has been developed. At 10 GHz, a 1.2-mm-gatewidth device has achieved an output power of 1.1 W with 10.5-dB gain and 31-percent power-added efficiency. At 20 GHz, the same device delivered an output power of 340 mW with 5.3-dB gain. At K-band, a dynamic-gain control range of up to 45 dB was obtained with an insertion phase change of no more than + or 2 degrees for the first 10 dB of gain control.

Kim, B.↗

Error control techniques for satellite and space communications

Two aspects of the work for NASA are examined: the construction of multi-dimensional phase modulation trellis codes and a performance analysis of these codes. A complete list is contained of all the best trellis codes for use with phase modulation. LxMPSK signal constellations are included for M = 4, 8, and 16 and L = 1, 2, 3, and 4. Spectral efficiencies range from 1 bit/channel symbol (equivalent to rate 1/2 coded QPSK) to 3.75 bits/channel symbol (equivalent to 15/16 coded 16-PSK). The parity check polynomials, rotational invariance properties, free distance, path multiplicities, and coding gains are given for all codes. These codes are considered to be the best candidates for implementation of a high speed decoder for satellite transmission. The design of a hardware decoder for one of these codes, viz., the 16-state 3x8-PSK code with free distance 4.0 and coding gain 3.75 dB is discussed. An exhaustive simulation study of the multi-dimensional phase modulation trellis codes is contained. This study was motivated by the fact that coding gains quoted for almost all codes found in literature are in fact only asymptotic coding gains, i.e., the coding gain at very high signal to noise ratios (SNRs) or very low BER. These asymptotic coding gains can be obtained directly from a knowledge of the free distance of the code. On the other hand, real coding gains at BERs in the range of 10(exp -2) to 10(exp -6), where these codes are most likely to operate in a concatenated system, must be done by simulation.

Costello, Daniel J., Jr.↗

Mobile terminal antennas for helicopters

In this paper, the feasibility of using an L-band low gain antenna (LGA) as a mobile terminal antenna for helicopters is described. The objective is to select the lowest cost antenna system which can be easily mounted on a helicopter and capable of communicating with a geosynchronous satellite. To ensure that all the antenna options are being considered, the steerable high gain reflector and medium gain array antennas as well as LGA are studied and compared in an exhaustive survey. The high gain reflector antenna in L-band is usually very large in size and heavy in weight. In addition, a bulky and expensive tracking system is needed to steer the antenna beam to the satellite direction. The medium gain antennas (including mechanically and electronically steered arrays) are also more expensive and less reliable than an LGA due to the addition of a beam steering system to track the satellite. The omni-directional LGA is simple, reliable, and inexpensive. It is typically ten times smaller than the medium gain antenna. This makes the position, selection, and mounting on the helicopter relatively easier. Therefore, the LGA is selected as a mobile terminal antenna for helicopters. Among the many LGA's (cross-dipole, helix, spiral, and slot antennas), the helix antenna is the most inexpensive. One can also change the size, shape, or pitch angle of the helix to optimize the gain in the desired direction. Therefore, the helix antenna is selected for further study. Both 2-arm and 4-arm helices are studied theoretically and experimentally to determine the antenna's performance and the scattering effects from the helicopter body and the blades. The multipath, Doppler, and Doppler rate issues as well as the periodic fading effects caused by the helicopter rotor blades will be briefly discussed in the paper.

Wu, Te-Kao↗

Experiment K-7-31: Studies of Vestibular Primary Afferents and Eye Movements in Normal, Hypergravity and Hypogravity - Axon Cosmos Flight 2044

Fourteen days of active head movements in microgravity appear to modify the gain and neural adaptation properties of the horizontal semicircular canals in the rhesus monkey. This is the first demonstration of adaptive plasticity in the sensory receptor. Reversing prisms, for example, do not modify the gain of the primary afferent response. Pulse yaw rotation, sinusoidal rotation, and sum of sinusoidal rotation testing during the first day following recovery revealed that the gain of a sample of afferents was significantly greater than the gain derived from afferent responses obtained during pre-flight and control monkey testing. There was no strong evidence of tilt sensitivity in the sample of afferents that we tested either during the pre-flight or control tests or during the first day post-flight. Two irregular afferents tested on postflight day 2 showed changes with tilt but the responses were not systematic. The spontaneous discharge did not change following flight. Mean firing rate and coefficient of variation remained constant during the post flight tests and was near the value measured during pre flight tests. The change in gain of horizontal canal afferents might be adaptive. The animals were required to look at a target for food. This required active head and eye movements. Active head movements have been shown to be hypometric and eye movements have been shown to be hypermetric during the first few days of past Cosmos flights (see introduction). It might be that the increased gain in the horizontal semicircular canals permit accurate target acquisition during hypometric head movements by driving the eyes to greater angles for smaller angles of head movement. The mechanism by which the semicircular canals recalibrate (increase their gain) is unknown. The efferent vestibular system is a logical candidate. Horizontal nystagmus during rotation about an earth vertical axis with the horizontal semicircular canals in the plane of rotation produced the same response during postflight day 1 and post-flight day 9. But when the head was pitched down 45? the nystagmus slow phase velocity was greater and the duration was about twice during post-flight day 1. Apparently, this response involving the interaction of the horizontal and vertical semicircular canals and the otoliths did not recalibrate during post-flight day 1. The 'DC' bias of the slow phase velocity of the horizontal nystagmus during constant velocity horizontal axis rotation was roughly 4 times for one flight monkey and roughly 2 times for the other on post-flight day 1 compared to post-flight day 9. These results suggest that the otolith mediated response during constant velocity rotation also did not recalibrate on post-flight day 1.

Correia, M. J.↗

Studies of Vestibular Neurons in Normal, Hyper- and Hypogravity

During the past year, pre-, in- and postflight studies were conducted in association with the Axon project for Bion 10 (Cosmos 2229). Recordings were made during pre- and postflight studies, from 118 horizontal semicircular canal afferents and 27 vestibular nucleus neurons in 7 rhesus monkeys; 137 pulse rotation protocols alone were executed (548 acceleration and deceleration responses were curve fit). Usable data was obtained from 127 horizontal afferents concerning their spontaneous discharge. Curve fits and analysis was made of sinusoidal and sum of sinusoidal responses from 42 and 35 horizontal afferents, respectively. Also recordings were made from neurons inflight from the two flight animals. The mean spontaneous rate varied from 128 spikes/sec. during preflight to 92 spikes/sec during postflight (day 5) - a change of 28%. In direct contrast to the results of Cosmos 2044, the best fitted neural adaptation operator (k) and the gain of the pulse response were decreased during post flight when compared to preflight. Surprisingly, the best fitted gain and k values for the sum of sines were slightly elevated during post flight tests. The gain and phase of single sine responses were compared for pre- and post flight tests and compared to a larger population of afferents. In contrast to Cosmos 2044 results where on the first day of post flight testing the gains of the best fitted sine response were skewed toward the higher values of the Miles and Braitman distribution, the gain of the best fitted sine responses during the first day of post flight testing (day 2) during Cosmos 2229 were exactly on the mode of the Miles and Braitman distribution. Thus, at least for the periodic stimuli, (pulses and sine waves) we found no change in gain and neural adaptation during post flight testing following Cosmos 2229. This conclusion is different from the one derived following the Cosmos 2044 flight. Cosmos flight 2229 differed from Cosmos flight 2044 in several significant ways: For example, during preflight, (1) The animals preflight training was different (less well trained on the gaze task) and (2) the animals were exposed to more experimental manipulations (surgical and rotational). Inflight, (1) the animals were required to make a pointing gesture (motor response) in association with eye movements to obtain reward, (2) the inflight diet was different (more balanced), (3) the feeder for one of the animals clogged following 9 days of flight resulting in evident dehydration and probably less head motion exposure in that monkey and (4) there was limited video taping of the monkeys in space. During postflight, (1) we were unable to test the flight animals until 26 hours postflight as compared to 14.5 hours during Cosmos 2044, (2) the animals received significantly more exposure to motion stimuli during postflight testing than during Cosmos 2044. These differences in the vestibular environment will require analysis of several parameters other than just neural and eye movement responses. For example, computer programs will have to be written and used to recover and quantify the number of head movements made by each animal during flight. This activity is critical to the production of neural adaptation and increased gain.

Correia, Manning J.↗

946 nm Diode Pumped Laser Produces 100mJ

An innovative approach to obtaining high energy at 946 nm has yielded 101 mJ of laser energy with an optical-to-optical slope efficiency of 24.5%. A single gain module resonator was evaluated, yielding a maximum output energy of 50 mJ. In order to obtain higher energy a second gain module was incorporated into the resonator. This innovative approach produced un-surprised output energy of 101 mJ. This is of utmost importance since it demonstrates that the laser output energy scales directly with the number of gain modules. Therefore, higher energies can be realized by simply increasing the number of gain modules within the laser oscillator. The laser resonator incorporates two gain modules into a folded "M-shaped" resonator, allowing a quadruple pass gain within each rod. Each of these modules consists of a diode (stack of 30 microlensed 100 Watt diode array bars, each with its own fiber lens) end-pumping a Nd:YAG laser rod. The diode output is collected by a lens duct, which focuses the energy into a 2 mm diameter flat to flat octagonal pump area of the laser crystal. Special coatings have been developed to mitigate energy storage problems, including parasitic lasing and amplified spontaneous emission (ASE), and encourage the resonator to operate at the lower gain transition at 946 nm.

Axenson, Theresa J.↗

Solar Pumped Solid State Lasers for Space Solar Power: Experimental Path

We outline an experimentally based strategy designed to lead to solar pumped solid state laser oscillators useful for space solar power. Our method involves solar pumping a novel solid state gain element specifically designed to provide efficient conversion of sunlight in space to coherent laser light. Kilowatt and higher average power is sought from each gain element. Multiple such modular gain elements can be used to accumulate total average power of interest for power beaming in space, e.g., 100 kilowatts and more. Where desirable the high average power can also be produced as a train of pulses having high peak power (e.g., greater than 10(exp 10 watts). The modular nature of the basic gain element supports an experimental strategy in which the core technology can be validated by experiments on a single gain element. We propose to do this experimental validation both in terrestrial locations and also on a smaller scale in space. We describe a terrestrial experiment that includes diagnostics and the option of locating the laser beam path in vacuum environment. We describe a space based experiment designed to be compatible with the Japanese Experimental Module (JEM) on the International Space Station (ISS). We anticipate the gain elements will be based on low temperature (approx. 100 degrees Kelvin) operation of high thermal conductivity (k approx. 100 W/cm-K) diamond and sapphire (k approx. 4 W/cm-K). The basic gain element will be formed by sequences of thin alternating layers of diamond and Ti:sapphire with special attention given to the material interfaces. We anticipate this strategy will lead to a particularly simple, robust, and easily maintained low mass modelocked multi-element laser oscillator useful for space solar power.

Fork, Richard L.↗

Ocular motor responses to abrupt interaural head translation in normal humans

We characterized the interaural translational vestibulo-ocular reflex (tVOR) in 6 normal humans to brief (approximately 200 ms), high-acceleration (0.4-1.4g) stimuli, while they fixed targets at 15 or 30 cm. The latency was 19 +/- 5 ms at 15-cm and 20 +/- 12 ms at 30-cm viewing. The gain was quantified using the ratio of actual to ideal behavior. The median position gain (at time of peak head velocity) was 0.38 and 0.37, and the median velocity gain, 0.52 and 0.62, at 15- and 30-cm viewing, respectively. These results suggest the tVOR scales proportionally at these viewing distances. Likewise, at both viewing distances, peak eye velocity scaled linearly with peak head velocity and gain was independent of peak head acceleration. A saccade commonly occurred in the compensatory direction, with a greater latency (165 vs. 145 ms) and lesser amplitude (1.8 vs. 3.2 deg) at 30- than 15-cm viewing. Even with saccades, the overall gain at the end of head movement was still considerably undercompensatory (medians 0.68 and 0.77 at 15- and 30-cm viewing). Monocular viewing was also assessed at 15-cm viewing. In 4 of 6 subjects, gains were the same as during binocular viewing and scaled closely with vergence angle. In sum the low tVOR gain and scaling of the response with viewing distance and head velocity extend previous results to higher acceleration stimuli. tVOR latency (approximately 20 ms) was lower than previously reported. Saccades are an integral part of the tVOR, and also scale with viewing distance.

Non-NASA Center↗

Response properties of pigeon otolith afferents to linear acceleration

In the present study, the sensitivity to sinusoidal linear accelerations in the plane of the utricular macula was tested in afferents. The head orientation relative to the translation axis was varied in order to determine the head position that elicited the maximal and minimal responses for each afferent. The response gain and phase values obtained to 0.5-Hz and 2-Hz linear acceleration stimuli were then plotted as a function of head orientation and a modified cosine function was fit to the data. From the best-fit cosine function, the predicted head orientations that would produce the maximal and minimal response gains were estimated. The estimated maximum response gains to linear acceleration in the utricular plane for the afferents varied between 75 and 1420 spikes s-1 g-1. The mean maximal gains for all afferents to 0.5-Hz and 2-Hz sinusoidal linear acceleration stimuli were 282 and 367 spikes s-1 g-1, respectively. The minimal response gains were essentially zero for most units. The response phases always led linear acceleration and remained constant for each afferent, regardless of head orientation. These response characteristics indicate that otolith afferents are cosine tuned and behave as one-dimensional linear accelerometers. The directions of maximal sensitivity to linear acceleration for the afferents varied throughout the plane of the utricle; however, most vectors were directed out of the opposite ear near the interaural axis. The response dynamics of the afferents were tested using stimulus frequencies ranging between 0.25 Hz and 10 Hz (0.1 g peak acceleration). Across stimulus frequencies, most afferents had increasing gains and constant phase values. These dynamic properties for individual afferents were fit with a simple transfer function that included three parameters: a mechanical time constant, a gain constant, and a fractional order distributed adaptation operator.

Non-NASA Center↗

Adaptation of primate vestibuloocular reflex to altered peripheral vestibular inputs. I. Frequency-specific recovery of horizontal VOR after inactivation of the lateral semicircular canals

1. The adaptive plasticity of the vestibuloocular reflex (VOR) following a selective lesion of the peripheral vestibular organs was investigated in rhesus monkeys whose lateral semicircular canals were inactivated by plugging of the canal lumen in both ears. Gain and phase of horizontal, vertical, and torsional slow-phase eye velocity were determined from three-dimensional eye movement recordings obtained acutely after the plugging operation, as well as in regular intervals up to 10 mo later. 2. Acutely after plugging, horizontal VOR was minimal during yaw rotation with gains of < 0.1 at all frequencies. Horizontal VOR gain gradually increased over time, reaching gains of 0.4-0.5 for yaw oscillations at 1.1 Hz approximately 5 mo after lateral canal inactivation. This response recovery was strongly frequency dependent: horizontal VOR gains were largest at the highest frequency tested and progressively decreased for lower frequencies. Below approximately 0.1 Hz, no consistent horizontal VOR could be elicited even 10 mo after plugging. 3. The frequency-dependent changes in gain paralleled changes in horizontal VOR phase. Below approximately 0.1-0.05 Hz large phase leads were present, similarly as in semicircular canal primary afferents. Smaller phase leads were also present at higher frequencies, particularly at 1.1 Hz (the highest frequency tested). 4. Consistent with the afferent-like dynamics of the adapted horizontal VOR, per- and postrotatory horizontal responses to constant-velocity yaw rotations were short lasting. Time constants of the slow-phase eye velocity envelope of the horizontal postrotatory nystagmus were approximately 2 s. Nonetheless, a consistent horizontal optokinetic afternystagmus was evoked in plugged animals. 5. A torsional component that was absent in intact animals was consistently present during yaw rotation acutely after lateral canal inactivation and remained approximately constant thereafter. The frequency response characteristics of this torsional component resembled those of the adapted horizontal slow-phase responses: gain decreased and large phase leads were introduced at frequencies below approximately 0.05-0.1 Hz. Torsional responses elicited by roll oscillations in supine position, on the other hand, were indistinguishable in their dynamics from intact animals. No consistent vertical nystagmus was elicited during yaw rotation. 6. Our results show that there is a slow, frequency-specific recovery of horizontal VOR after selective inactivation of the lateral semicircular canals. Both the spatial organization and the dynamic properties of the adapted VOR responses are distinctly different from responses in intact animals, suggesting complex changes in the underlying vestibuloocular circuitry.

NASA Program Space Physiology and Countermeasures↗

Performance Benefits Associated with Context-Dependent Arm Pointing Adaptation

Our previous work has demonstrated that head orientation can be used as a contextual cue to switch between mUltiple adaptive states. Subjects were assigned to one of three groups: the head orientation group tilted the head towards the right shoulder when drawing under a 0.5 gain of display and towards the left shoulder when drawing under a 1.5 gain of display; the target orientation group had the home & target positions rotated counterclockwise when drawing under the 0.5 gain and clockwise for the l.5 gain; the arm posture group changed the elbow angle of the arm they were not drawing with from full flexion to full extension with 0.5 and l.5 gain display changes. The head orientation cue was effectively associated with the multiple gains, in comparison to the control conditions. The purpose of the current investigation was to determine whether this context-dependent adaptation results in any savings in terms of performance measures such as movement duration and movement smoothness when subjects switch between multiple adaptive states. Subjects in the head adaptation group demonstrated reduced movement duration and increased movement smoothness (measured via normalized j erk scores) in comparison to the two control groups when switching between the 0.5 and 1.5 gain. of display. This work has demonstrated not only that subjects can acquire context-dependent adaptation, but also that it results in a significant savings of performance upon transfer between adaptive states

Seidler, R. D.↗

Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures

SweepSAR, a novel radar architecture that depends on a DBF (digital beamforming) array, requires calibration accuracies that are order(s) of magnitude greater than is possible with traditional techniques, such as a priori characterization of TR (transmit/receive) modules in thermal vacuum chambers, or simple loop-back of the calibration signal. The advantages of a SweepSAR architecture are so great that it is worth applying significant resources to calibration efforts. Due to the nature of the DBF, each channel contains a digitizer and very powerful digital processor. Each channel can independently digitize (with the digitizer) and analyze (with the processor) its channel's unique calibration signal, and extract the relevant calibration parameters, namely channel gain and channel phase delay commonly referred to as the gain (or amplitude) and phase of the channel. Using the processor, each channel's gain and phase can theoretically be estimated with arbitrary precision through averaging a sufficiently large number of samples. Systematic errors and the changing gain and phase of the channels, typically due to temperature drifts, limits how long the averaging can occur, which limits the precision of the calibration estimate. However, results indicate that calibration knowledge of both the transmit and receive chains of each TR module can be improved by one or two orders of magnitude. Due to the digital nature of the receiver data, the channel's gain and phase may be corrected by a similar amount, while the transmit chain can only be corrected in a traditional manner. To implement Sweep SAR, the order of magnitude improvement in the knowledge of the channel's gain and phase is needed, and the control of the receiver to a similar level is required. Inherent to the DBF array is the individual digitization of each of the array's receiver channels. Current systems typically combine all of the analog signals in the array into one or two analog channels, which are then digitized and processed. All signal conditioning performed prior to digitization is done using analog hardware (which is less precise than digital signal conditioning and dependent on temperature). The DBF digitizes every signal prior to combining, and can therefore analyze and correct received signals, as well as analyze signals that are being transmitted through analog hardware (by sampling a copy and digitizing). Each channel of a DBF also has a powerful processor. With this combination, one is able to digitize, analyze, and correct each channel prior to its being combined. A unique factor is the ability to digitize and analyze (in real time) each of the array's channels independently, allowing one to achieve unprecedented knowledge of each channel's performance (gain and phase), and since the combining is done digitally, each receive channel can be corrected prior to combining. This enables an unprecedented level of accuracy and control through onboard processing. SweepSAR promises significant increases in instrument capability for solid earth and biomass remote sensing, while reducing mission mass and cost. This new instrument concept requires new methods for calibrating the multiple channels, which must be combined onboard, in real time. New methods are being developed for digitally calibrating digital beam-forming arrays to reduce development time, risk, and cost of precision calibrated TR modules for array architectures by accurately tracking modules' characteristics through closed-loop digital calibration, thus tracking systematic changes regardless of temperature.-

Hoffman, James P.↗