Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Acoustic Emission Methods for the Health Evaluation of Integrated Pressure Components

At the request of the Pressure Systems Senior Discipline Expert, to overcome the access and detectable flaw size limitations of other nondestructive evaluation (NDE) methods for integrated components, a technique akin to seismology was advanced to perceive the earliest signs of cracking in titanium components before they escalate into serious issues. In this project we achieved a landmark in Acoustic Emission (AE) testing with the first NASA Probability of Detection (POD) study. This is an important first step to the certification of the AE method for flight components and was based on the testing of notched panels. By working closely with industry allies and employing approved methods from the boiler and pressure vessel sector, we not only met but surpassed all POD benchmarks with our test and acceptance criteria. In experiments involving solution heat-treated and aged 6Al-4V-Ti alloy tested with broadband sensors, we recorded a 96% success rate, with zero false positives reported. Our research shows that in some cases, AE testing can locate smaller cracks than other NDE methods. An industry tool for scaling results to full pressure vessels is highlighted. However, before applying our findings to NASA components, tests to validate the transfer functions are advised.

acoustic↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

W T Wallace↗

Interpretable Machine Learning Models for Autonomous Characterization of Analogue Ocean World Seawater Chemistry and Biosignature Potential Using Isotope Ratio Data

Background: Future missions to ocean worlds, such as Enceladus and Europa, will attempt to characterize the subsurface seawater chemistry and assess the potential for life. Such missions will be equipped with capabilities to precisely measure volatile isotopes in plumes, atmospheres, and exospheres. Motivation: While large isotopic fractionations can indicate a biological source, there are signatures resulting from abiotic geochemical processes that mimic isotopic biosignatures. While machine learning (ML) has the potential to disentangle competing effects and biotic mimicry, high-dimensional isotope ratio mass spectrometry (IRMS) data is likely to contain noise/irrelevant features and involve complex statistical interactions that make human inference and interpretation difficult. Further, ML predictions with as far-reaching implications as an extraterrestrial biosignature on an ocean world requires the use of interpretable models (i.e., not “black box” models) with physically and mathematically meaningful feature spaces along with false positive diagnostics. Methods: We use volatile CO2 IRMS data of analogue ocean world seawaters to validate an ML approach to provide biogeochemical context for biosignature detection. We employ a feature selection method called nearest-neighbor projected distance regression (NPDR) that detects statistical interactions and helps elucidate the mechanisms of the Random Forest classification models. Results: We train and validate predictive ML models on volatile CO2 IRMS data of analogue ocean world seawaters to predict major salt components (e.g., MgSO4, NaHCO3), pH, ionic strength, and the presence of biosignatures. Features derived from IRMS measurements are augmented with extracted time-series features. Our results show high test accuracy and interpretability, which is increased by interaction network visualization, sample-wise variable importance scores, and single-sample class probability estimates. We demonstrate an ML mission software solution that triggers autonomous data transmission and biogeochemical sample prediction.

geochemistry↗

Tensor Decomposition Analysis for UAV Anomaly Detection

Vibrational anomalies can provide valuable insights into the health status of an unmanned aerial vehicle, potentially indicating system degradation including propeller, motor, or sensor damage, as well as environmental anomalies such as strong wind gusts and turbulence. However, many causes for vibrational anomalies are not related to vehicle health, such as sharp shifts in velocity or direction of flight. Thus, depending strictly on vibration signals to detect anomalies can result in false positives for failures. Hence, it is important to include additional telemetries in detecting and diagnosing in-flight anomalies. This paper considers an approach to anomaly detection based on tensor decompositions that incorporates information from vibration signals, as well as additional flight data such as velocity, current draw, voltage drop, and attitude. Using experimental flight data collected by the University of Notre Dame, we construct third-order tensors then apply the CANDECOMP/PARAFAC decomposition to identify trends within each flight and classify flights as nominal or anomalous.

unmanned aviation↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

Structural Analyses and Margins of Safety

There is an increasing reliance on modeling and simulation to verify, quantify, and certify designs of complex structures. The availability of a range of commercial modeling and simulations tools and packages with a variety of capabilities, in conjunction with increased computational resources, is allowing analysts to rapidly perform detailed analyses. However, care should be taken to understand specific tool limitations, assumptions, and boundary conditions as erroneous results can be generated without being recognized by the analysts. In addition, the reported margins of safety should be carefully interrogated to identify any false positive or negative margins and highlight any areas for structural concern.

Structural Analyses↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

W T Wallace↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

William T Wallace↗

Automatic Detection of Large-scale Flux Ropes and Their Geoeffectiveness with a Machine-learning Approach

Detecting large-scale flux ropes (FRs) embedded in interplanetary coronal mass ejections (ICMEs) and assessing their geoeffectiveness are essential, since they can drive severe space weather. At 1 au, these FRs have an average duration of 1 day. Their most common magnetic features are large, smoothly rotating magnetic fields. Their manual detection has become a relatively common practice over decades, although visual detection can be time-consuming and subject to observer bias. Our study proposes a pipeline that utilizes two supervised binary classification machine-learning models trained with solar wind magnetic properties to automatically detect large-scale FRs and additionally determine their geoeffectiveness. The first model is used to generate a list of autodetected FRs. Using the properties of the southward magnetic field, the second model determines the geoeffectiveness of FRs. Our method identifies 88.6% and 80% of large-scale ICMEs (duration 1day) observed at 1au by the Wind and the Solar TErrestrial RElations Observatory missions, respectively. While testing with continuous solar wind data obtained from Wind, our pipeline detected 56 of the 64 large-scale ICMEs during the 2008–2014 period (recall = 0.875), but also many false positives (precision = 0.56), as we do not take into account any additional solar wind properties other than the magnetic properties. We find an accuracy of 0.88 when estimating the geoeffectiveness of the autodetected FRs using our method. Thus, in space-weather nowcasting and forecasting at L1 or any planetary missions, our pipeline can be utilized to offer a first-order detection of large-scale FRs and their geoeffectiveness.

Sanchita Pal↗

Investigating the Use of Machine Learning (ML) to Assess Tropospheric Doppler Radar Wind Profiler (TDRWP) Data Quality

Manual Quality Control (MQC) of Tropospheric Doppler Radar Wind Profiler (TDRWP) data is essential for defining an accurate climatology for downstream aerospace vehicle assessments. MQC traditionally takes around 30.5 hours per year of radar data. The Marshall Space Flight Center Natural Environments Branch (MSFC NE) used machine learning (ML) to test the feasibility of automating the MQC process, showing a potential to reduce labor by 300%. However, analysis of the model showed some false positives. We compared a neural network to the model to validate it and develop a process for assessing comparable solutions in the future.

Corey Walker↗

A Multi-Tier Autonomous Aerial Architecture for Wildfire Detection, Characterization, and Communication in Infrastructure-Denied Environments

Wildfire response depends on how fast an ignition can be confirmed and located, especially in remote regions where ground-based communication and monitoring may be limited. Geostationary sensors provide frequent observations but at kilometer-scale resolution, which is too coarse to resolve small fires in remote terrain. Ground camera networks require sightlines and infrastructure that back-country areas lack. To address these limitations, this work proposes a Multi-Tier Autonomous Wildfire Intelligence System that combines wide-area monitoring with targeted, high-resolution sensing. A solar-powered high-altitude long endurance (HALE) platform operating at approximately 60,000 ft provides persistent wide-area thermal and optical surveillance, running onboard edge inference to screen candidate ignitions and reduce false positives and downlink bandwidth. When a candidate ignition is detected, low-altitude uncrewed aircraft systems (UAS) can be deployed to conduct localized observations, including high-resolution imaging and atmospheric measurements such as wind and plume observation. By combining persistent detection with local sensing, the proposed architecture is designed to provide first responders with timely, high-resolution information about fire location and behavior to aid in emergency decision making.

Wildfire management, UAS, drones↗

Bright Retinal Lesions Detection using Colour Fundus Images Containing Reflective Features

In the last years the research community has developed many techniques to detect and diagnose diabetic retinopathy with retinal fundus images. This is a necessary step for the implementation of a large scale screening effort in rural areas where ophthalmologists are not available. In the United States of America, the incidence of diabetes is worryingly increasing among the young population. Retina fundus images of patients younger than 20 years old present a high amount of reflection due to the Nerve Fibre Layer (NFL), the younger the patient the more these reflections are visible. To our knowledge we are not aware of algorithms able to explicitly deal with this type of reflection artefact. This paper presents a technique to detect bright lesions also in patients with a high degree of reflective NFL. First, the candidate bright lesions are detected using image equalization and relatively simple histogram analysis. Then, a classifier is trained using texture descriptor (Multi-scale Local Binary Patterns) and other features in order to remove the false positives in the lesion detection. Finally, the area of the lesions is used to diagnose diabetic retinopathy. Our database consists of 33 images from a telemedicine network currently developed. When determining moderate to high diabetic retinopathy using the bright lesions detected the algorithm achieves a sensitivity of 100% at a specificity of 100% using hold-one-out testing.

60 APPLIED LIFE SCIENCES↗

REAL TIME DATA FOR REMEDIATION ACTIVITIES [11505]

Health physicists from the CH2M HILL Plateau Remediation Company collaborated with Berkeley Nucleonics Corporation to modify the SAM 940 isotope identifier instrument to be used for nuclear waste remediation. These modifications coupled with existing capabilities of the SAM 940 have proven to be invaluable during remediation activities, reducing disposal costs by allowing swift remediation of targeted areas that have been identified as having isotopes of concern (IOC), and eliminating multiple visits to sites by declaring an excavation site clear of IOCs before demobilizing from the site. These advantages are enabled by accumulating spectral data for specific isotopes that is nearly 100 percent free of false positives, which are filtered out in 'real time.'

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

Planetary Candidates Observed by Kepler, III: Analysis of the First 16 Months of Data

New transiting planet candidates are identified in sixteen months (May 2009 - September 2010) of data from the Kepler spacecraft. Nearly five thousand periodic transit-like signals are vetted against astrophysical and instrumental false positives yielding 1091 viable new planet candidates, bringing the total count up to over 2,300. Improved vetting metrics are employed, contributing to higher catalog reliability. Most notable is the noise-weighted robust averaging of multiquarter photo-center offsets derived from difference image analysis which identifies likely background eclipsing binaries. Twenty-two months of photometry are used for the purpose of characterizing each of the new candidates. Ephemerides (transit epoch, T{sub 0}, and orbital period, P) are tabulated as well as the products of light curve modeling: reduced radius (R{sub P}/R{sub {star}}), reduced semi-major axis (d/R{sub {star}}), and impact parameter (b). The largest fractional increases are seen for the smallest planet candidates (197% for candidates smaller than 2R{sub {circle_plus}} compared to 52% for candidates larger than 2R{sub {circle_plus}}) and those at longer orbital periods (123% for candidates outside of 50 day orbits versus 85% for candidates inside of 50 day orbits). The gains are larger than expected from increasing the observing window from thirteen months (Quarter 1 - Quarter 5) to sixteen months (Quarter 1 - Quarter 6). This demonstrates the benefit of continued development of pipeline analysis software. The fraction of all host stars with multiple candidates has grown from 17% to 20%, and the paucity of short-period giant planets in multiple systems is still evident. The progression toward smaller planets at longer orbital periods with each new catalog release suggests that Earth-size planets in the Habitable Zone are forthcoming if, indeed, such planets are abundant.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micro-Analysis of Actinide Minerals for Nuclear Forensics and Treaty Verification

Micro-Raman spectroscopy has been demonstrated to be a viable tool for nondestructive determination of the crystal phase of relevant minerals. Collecting spectra on particles down to 5 microns in size was completed. Some minerals studied were weak scatterers and were better studied with the other techniques. A decent graphical software package should easily be able to compare collected spectra to a spectral library as well as subtract out matrix vibration peaks. Due to the success and unequivocal determination of the most common mineral false positive (zircon), it is clear that Raman has a future for complementary, rapid determination of unknown particulate samples containing actinides.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameter Analysis of the VPIN (Volume synchronized Probability of Informed Trading) Metric

VPIN (Volume synchronized Probability of Informed trading) is a leading indicator of liquidity-induced volatility. It is best known for having produced a signal more than hours before the Flash Crash of 2010. On that day, the market saw the biggest one-day point decline in the Dow Jones Industrial Average, which culminated to the market value of $1 trillion disappearing, but only to recover those losses twenty minutes later (Lauricella 2010). The computation of VPIN requires the user to set up a handful of free parameters. The values of these parameters significantly affect the effectiveness of VPIN as measured by the false positive rate (FPR). An earlier publication reported that a brute-force search of simple parameter combinations yielded a number of parameter combinations with FPR of 7%. This work is a systematic attempt to find an optimal parameter set using an optimization package, NOMAD (Nonlinear Optimization by Mesh Adaptive Direct Search) by Audet, le digabel, and tribes (2009) and le digabel (2011). We have implemented a number of techniques to reduce the computation time with NOMAD. Tests show that we can reduce the FPR to only 2%. To better understand the parameter choices, we have conducted a series of sensitivity analysis via uncertainty quantification on the parameter spaces using UQTK (Uncertainty Quantification Toolkit). Results have shown dominance of 2 parameters in the computation of FPR. Using the outputs from NOMAD optimization and sensitivity analysis, We recommend A range of values for each of the free parameters that perform well on a large set of futures trading records.

97 MATHEMATICS AND COMPUTING↗

Forensic Signature Detection of Yersinia Pestis Culturing Practices Across Institutions Using a Bayesian Network

The field of bioforensics is focused on the analysis of evidence from a biocrime. Existing laboratory analyses can identify the specific strain of an organism in the evidence, as well signatures of the specific culture batch of organisms, such as low-frequency contaminants or indicators of growth and processing methods. To link these disparate types of physical data to potential suspects, investigators may need to identify institutions or individuals whose access to strains and culturing practices match those identified from the evidence. In this work we present a Bayesian statistical network to fuse different types of analytical measurements that predict the production environment of a Yersinia pestis sample under investigation with automated test processing of scientific publications to identify institutions with a history of growing Y. pestis under similar conditions. Furthermore, the textual and experimental signatures were evaluated recursively to determine the overall sensitivity of the network across all levels of false positives. We illustrate that institutions associated with several specific culturing practices can be accurately selected based on the experimental signature from only a few analytical measurements. These findings demonstrate that similar Bayesian networks can be generated generically for many organisms of interest and their deployment is not prohibitive due to either computational or experimental factors.

Bayesian networks↗