Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Final Report on Statistical Debugging for Petascale Environments

Statistical debugging identifies program behaviors that are highly correlated with failures. Traditionally, this approach has been applied to desktop software. In this context, statistical debugging is effective in identifying the causes that underlie several difficult classes of bugs. These include memory corruption, non-deterministic bugs, and bugs with multiple temporally-distant triggers.

97 MATHEMATICS AND COMPUTING↗

SHIELDS Final Technical Report

Predicting variations in the near-Earth space environment that can lead to spacecraft damage and failure, i.e. “space weather”, remains a big space physics challenge. A new capability was developed at Los Alamos National Laboratory (LANL) to understand, model, and predict Space Hazards Induced near Earth by Large Dynamic Storms, the SHIELDS framework. This framework simulates the dynamics of the Surface Charging Environment (SCE), the hot (keV) electrons representing the source and seed populations for the radiation belts, on both macro- and micro-scale. In addition to using physics-based models (like RAM-SCB, BATS-R-US, and iPIC3D), new data assimilation techniques employing data from LANL instruments on the Van Allen Probes and geosynchronous satellites were developed. An order of magnitude improvement in the accuracy in the simulation of the spacecraft surface charging environment was thus obtained. SHIELDS also includes a post-processing tool designed to calculate the surface charging for specific spacecraft geometry using the Curvilinear Particle-In-Cell (CPIC) code and to evaluate anomalies' relation to SCE dynamics. Such diagnostics is critically important when performing forensic analyses of space-system failures.

79 ASTRONOMY AND ASTROPHYSICS↗

ATS-4 study program, volume 2 Final report

Systems analysis of Applications Technology Satellite-4 - mission and power profiles, antenna array accuracy and efficiency, failure modes, and weight summaries

ANTENNA ARRAY↗

Connecting Research and Practice: An Experience Report on Research Infusion with SAVE

NASA systems need to be highly dependable to avoid catastrophic mission failures. This calls for rigorous engineering processes including meticulous validation and verification. However, NASA systems are often highly distributed and overwhelmingly complex, making the software portion of these systems challenging to understand, maintain, change, reuse, and test. NASA's systems are long-lived and the software maintenance process typically constitutes 60-80% of the total cost of the entire lifecycle. Thus, in addition to the technical challenges of ensuring high life-time quality of NASA's systems, the post-development phase also presents a significant financial burden. Some of NASA's software-related challenges could potentially be addressed by some of the many powerful technologies that are being developed in software research laboratories. Many of these research technologies seek to facilitate maintenance and evolution by for example architecting, designing and modeling for quality, flexibility, and reuse. Other technologies attempt to detect and remove defects and other quality issues by various forms of automated defect detection, architecture analysis, and various forms of sophisticated simulation and testing. However promising, most such research technologies nevertheless do not make the transition from the research lab to the software lab. One reason the transition from research to practice seldom occurs is that research infusion and technology transfer is difficult. For example, factors related to the technology are sometimes overshadowed by other types of factors such as reluctance to change and therefore prohibits the technology from sticking. Successful infusion might also take very long time. One famous study showed that the discrepancy between the conception of the idea and its practical use was 18 years plus or minus three. Nevertheless, infusing new technology is possible. We have found that it takes special circumstances for such research infusion to succeed: 1) there must be evidence that the technology works in the practitioner's particular domain, 2) there must be a potential for great improvements and enhanced competitive edge for the practitioner, 3) the practitioner has to have strong individual curiosity and continuous interest in trying out new technologies, 4) the practitioner has to have support on multiple levels (i.e. from the researchers, from management, from sponsors etc), and 5) to remain infused, the new technology has to be integrated into the practitioner's processes so that it becomes a natural part of the daily work. NASA IV&V's Research Infusion initiative sponsored by NASA's Office of Safety & Mission Assurance (OSMA) through the Software Assurance Research Program (SARP), strives to overcome some of the problems related to research infusion.

Lindvall, Mikael↗

Independent Orbiter Assessment (IOA): Analysis of the Orbiter Experiment (OEX) subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Experiments hardware. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. The Orbiter Experiments (OEX) Program consists of a multiple set of experiments for the purpose of gathering environmental and aerodynamic data to develop more accurate ground models for Shuttle performance and to facilitate the design of future spacecraft. This assessment only addresses currently manifested experiments and their support systems. Specifically this list consists of: Shuttle Entry Air Data System (SEADS); Shuttle Upper Atmosphere Mass Spectrometer (SUMS); Forward Fuselage Support System for OEX (FFSSO); Shuttle Infrared Laced Temperature Sensor (SILTS); Aerodynamic Coefficient Identification Package (ACIP); and Support System for OEX (SSO). There are only two potential critical items for the OEX, since the experiments only gather data for analysis post mission and are totally independent systems except for power. Failure of any experiment component usually only causes a loss of experiment data and in no way jeopardizes the crew or mission.

Compton, J. M.↗

Analysis for the Progressive Failure Response of Textile Composite Fuselage Frames

A part of aviation accident mitigation is a crash worthy airframe structure, and an important measure of merit for a crash worthy structure is the amount of kinetic energy that can be absorbed in the crush of the structure. Prediction of the energy absorbed from finite element analyses requires modeling the progressive failure sequence. Progressive failure modes may include material degradation, fracture and crack growth, and buckling and collapse. The design of crash worthy airframe components will benefit from progressive failure analyses that have been validated by tests. The subject of this research is the development of a progressive failure analysis for textile composite. circumferential fuselage frames subjected to a quasi-static, crash-type load. The test data for these frames are reported, and these data, along with stub column test data, are to be used to develop and to validate methods for the progressive failure response.

Johnson, Eric R.↗

Embolization Coils Migrating and Being Passed per Rectum After Embolization of a Splenic Artery Pseudoaneurysm, 'The Migrating Coil': A Case Report

Acute or chronic blood loss from pseudoaneurysms of the splanchnic artery in chronic pancreatitis poses diagnostic and management challenges. Arteriographic examination offers both diagnostic and therapeutic options, with success rates of 76%-100% for both modalities. In cases of failure of embolization, repeat embolization is also an option. Surgical intervention is advocated for rebleeding and failure of embolization. Evidence-based guidelines regarding the optimal treatment modality for this condition are lacking. There has been a reported case of dislodgement of coil into the stomach through a gastropseudocystic fistula. We report the case of a migrating steel-wire coil through the gastrointestinal tract and splenic artery pseudoaneurysm. We highlight the potential complications of pseudoaneurysm and other available therapeutic management options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Spot-Scanning Proton Radiation Therapy for Chordoma and Chondrosarcoma in Children and Adolescents: Initial Experience at Paul Scherrer Institute

Purpose: To evaluate postoperative spot-scanning proton radiation therapy (PT) and intensity-modulated PT (IMPT) for chordoma and chondrosarcoma in pediatric patients. Methods and Materials: Between 2000 and 2005, 10 patients (six male patients, four female patients; six chordomas, four chondrosarcomas), aged 10-20 years (median, 16 years), were treated at our institute. Tumor sites were in the brain (one case), skull base (five cases), cervical (three cases), and lumbar spine (one case). Three children had complete resections. In seven children, resection was incomplete, leaving residual tumor behind (range, 2.3-46.3 mL). PT was delivered using spot scanning, with (three patients) or without (seven patients) IMPT. Total dose was 74.0 cobalt Gray equivalents (CGE) for chordoma, and 63.2-68.0 CGE for chondrosarcoma (median, 66.0), depending on histopathological grading and whether the patient had concurrent chemotherapy. Results: Median follow-up time was 36 months (range, 8-77 months). Radiation treatment was well tolerated. All patients remained failure-free at their last follow-up. Late adverse events were reported in three patients and were mild (neurosensory in one patient; alopecia and hypoaccusis in one patient) to moderate (one patient, Grade 2 pituitary insufficiency). Conclusions: Postoperative spot-scanning PT, delivered in combination with and without IMPT, for chordoma and chondrosarcoma in children and adolescents was tolerated without unacceptable adverse event and initial outcome is perfectly satisfactory in this small cohort. Longer follow-up time and larger cohort are needed to more fully assess tumor control, adverse events, as well as functional and cosmetic outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protein Kinase A RI-{alpha} Predicts for Prostate Cancer Outcome: Analysis of Radiation Therapy Oncology Group Trial 86-10

Purpose: The RI-{alpha} regulatory subunit of protein kinase A type 1 (PKA) is constitutively overexpressed in human cancer cell lines and is associated with active cell growth and neoplastic transformation. This report examined the association between PKA expression and the endpoints of biochemical failure (BF), local failure (LF), distant metastasis (DM), cause-specific mortality (CSM), and overall mortality in men treated with radiotherapy, with or without short-term androgen deprivation in Radiation Therapy Oncology Group trial 86-10. Methods and Materials: Pretreatment archival diagnostic tissue samples from 80 patients were stained for PKA by immunohistochemical methods from a parent cohort of 456 cases. PKA intensity was scored manually and by image analysis. The Cox proportional hazards model for overall mortality and Fine and Gray's regression models for CSM, DM, LF and BF were then applied to determine the relationship of PKA expression to the endpoints. Results: The pretreatment characteristics of the missing and determined PKA groups were not significantly different. On univariate analyses, a high PKA staining intensity was associated with BF (image analysis, continuous variable, p = 0.022), LF (image analysis, dichotomized variable, p = 0.011), CSM (manual analysis, p = 0.037; image analysis, continuous, p = 0.014), and DM (manual analysis, p = 0.029). On multivariate analyses, the relationships to BF (image analysis, continuous, p = 0.03), LF (image analysis, dichotomized, p = 0.002), and DM remained significant (manual analysis, p = 0.018). In terms of CSM, a trend toward an association was seen (manual analysis, p = 0.08; image analysis, continuous, p = 0.09). Conclusion: PKA overexpression was significantly related to patient outcome and is a potentially useful biomarker for identifying high-risk prostate cancer patients who might benefit from a PKA knockdown strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Five-Year Biochemical Results, Toxicity, and Patient-Reported Quality of Life After Delivery of Dose-Escalated Image Guided Proton Therapy for Prostate Cancer

Purpose: To report clinical outcomes in patients treated with image guided proton therapy (PT) for localized prostate cancer. Methods and Materials: The medical records of 1327 men were reviewed. Each man was enrolled on an outcomes tracking study. Dual enrollment on a prospective clinical trial was allowed. Each patient was treated for localized prostate cancer with PT at our institution between 2006 and 2010. Ninety-eight percent of patients received 78 Gy (radiobiological equivalent [RBE]) or higher; 18% received androgen deprivation therapy (ADT). The 5-year freedom from biochemical progression (FFBP), distant metastasis-free survival, and cause-specific survival rates are reported for each risk group. Data on patient-reported quality of life and high-grade toxicities were prospectively collected and reported. A multivariate analysis was performed to identify clinical predictors of biochemical failure and urologic toxicity. Results: The median follow-up time was 5.5 years. The 5-year FFBP rates were 99%, 94%, and 74% in low-risk, intermediate-risk, and high-risk patients, respectively. The actuarial 5-year rates of late grade 3+ Common Terminology Criteria for Adverse Events, version 4.0, gastrointestinal (GI) and genitourinary (GU) toxicity were 0.6% and 2.9%, respectively. Multivariate analysis showed a significant correlation between grade 3+ GU toxicity and pretreatment prostate reductive procedures (P<.0001), prostate volume (P=.0085), pretreatment α-blockers (P=.0067), diabetes (P=.0195), and dose–volume histogram parameters (P=.0208). The median International Prostate Symptom Scores pretreatment scores and scores at 5 years after treatment were 7 and 7, respectively. The mean Expanded Prostate Cancer Index Composite (EPIC) scores significantly declined for sexual summary for patients not receiving ADT (from 67 to 53) between baseline and 5 years. Conclusions: Image guided PT provided excellent biochemical control rates for patients with localized prostate cancer. The actuarial rates of high-grade toxicity were low after PT. From pretreatment to 5 years of follow-up, a significant decline was found only in mean EPIC sexual summary scores. Prospective clinical studies are needed to determine the comparative effectiveness of PT and other radiation treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Automated Hazard Detection Framework for Health Information Technology Systems

An increase in the reliability of Health Information Technology (HIT) will facilitate institutional trust and credibility of the systems. Here, we present an end-to-end framework for improving the reliability and performance of HIT systems. Specifically, we describe the system model, present some of the methods that drive the model, and discuss an initial implementation of two of the proposed methods using data from the Veterans Affairs HIT and Corporate Data Warehouse systems. The contributions of this work, thus, include (1) the design of a system model for monitoring and detecting hazards in HIT systems, (2) a data-driven approach for analysing the health care data warehouse, (3) analytical methods for characterising and analysing failures in HIT systems, and (4) a tool architecture for generating and reporting hazards in HIT systems. Our goal is to work towards an automated system that will help identify opportunities for improvements in HIT systems.

97 MATHEMATICS AND COMPUTING↗

Evaluation of PV Module Field Performance

This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.

14 SOLAR ENERGY↗

Drain Tank Information for Developing Design Basis of the Preliminary Design - R00

Tokamak Cooling Water System (TCWS) drain tanks (DTs) serve two functions: normal operation and safety operation. Normal DTs are used for regular maintenance operations when draining is necessary. Safety DTs are used to receive the water leaked into the Vacuum Vessel (VV) after an in-vessel loss of cooling accident (LOCA) event. The preliminary design of the DTs shall be based on the information provided by this document. The capacity of the normal DTs is estimated based on the internal volume of in-vessel components [e.g., First Wall/Blanket (FW/BLK) and Divertor (DIV)], Neutral Beam Injector (NBI) components, and TCWS piping, heat exchangers, electric heaters, pump casing, pressurizers, and valves. Water volumes have been updated based on 2004 design information, changes adopted because of approved Project Change Requests (PCRs), and data verification by U.S. ITER. Two tanks will store water from normal draining operations of the FW/BLK and DIV Primary Heat Transfer Systems (PHTSs). One tank will store water from normal draining operations of the NBI PHTS. The capacity of the safety DTs is based on analysis of a design-basis accident:1 a large leak from in-vessel components. There are two safety DTs that will receive water from a VV LOCA event and drainage from the VV, as needed. In addition, there is one sump tank for the DIV that will be used for collecting drain water from the draining and drying processes and specifically for draining the DIV system as the DIV cassettes lines are at a lower elevation than the DT connection point. Information documented in this report must be refined and verified during the preliminary design of the DTs, and there are several aspects to be considered to complete the preliminary design. Input to these design considerations is discussed in this report and includes, but is not limited to, water inventory; operating procedures/maintenance; Failure Modes and Effects Analysis (FMEA); tank layout anddimensions, including design margin; classification under French Nuclear Pressure Directives, Equipements Sous Pression Nucleaires (ESPN); and adaptations for construction.

Cooling Water↗

Drain Tank Information for Developing Design Basis of the Preliminary Design

Tokamak Cooling Water System (TCWS) drain tanks (DTs) serve two functions: normal operation and safety operation. Normal DTs are used for regular maintenance operations when draining is necessary. Safety DTs are used to receive the water leaked into the Vacuum Vessel (VV) after an in-vessel loss of coolant accident (LOCA) event. The preliminary design of the DTs shall be based on the information provided by this document. The capacity of the normal DTs is estimated based on the internal volume of in-vessel components [e.g., First Wall/Blanket (FW/BLK) and Divertor (DIV)]; Neutral Beam Injector (NBI) components; and TCWS piping, heat exchangers, electric heaters, pump casing, pressurizers, and valves. Water volumes have been updated based on 2004-design information, changes adopted because of approved Project Change Requests (PCRs), and data verification by US ITER and AREVA Federal Services, the US ITER A and E Company. Two tanks will store water from normal draining operations of the FW/BLK and DIV Primary Heat Transfer Systems (PHTSs). One tank will store water from normal draining operations of the NBI PHTS. The capacity of the safety DTs is based on analysis of a design basis accident: a large leak from in-vessel components. There are two safety DTs that will receive water from a VV LOCA event and drainage from the VV, as needed. In addition, there is one sump tank for the DIV that will be used for collecting drain water from the draining and drying processes and specifically for draining the DIV system as the DIV cassette lines are at a lower elevation than the DT connection point. Information documented in this report must be refined and verified during the preliminary design of the DTs, and there are several aspects to be considered to complete the preliminary design. Input to these design considerations is discussed in this report and includes, but is not limited to, water inventory; operating procedures/maintenance; Failure Modes and Effects Analysis (FMEA); tank layout and dimensions, including design margin; classification under French Nuclear Pressure Directives, Equipements Sous Pression Nucleaires (ESPN); and adaptations for construction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactive program for analysis and design problems in advanced composites technology

During the past year an experimental program in the fracture of advanced fiber composites has been completed. The experimental program has given direction to additional experimental and theoretical work. A synthesis program for designing low weight multifastener joints in composites is proposed, based on extensive analytical background. A number of failed joints have been thoroughly analyzed to evaluate the failure hypothesis used in the synthesis procedure. Finally, a new solution is reported for isotropic and anisotropic laminates using the boundary-integral method. The solution method offers significant savings of computer core and time for important problems.

Cruse, T. A.↗

Hovering impulsive noise: Some measured and calculated results

In-plane impulsive noise radiating from a hovering model rotor was measured in an anechoic environment. The hover acoustic signature was compared with existing theoretical prediction models with previous forward flight experiments using the same model rotor. These hover tests showed good experimental consistency with forward flight measurements, both in pressure level, and waveform character, over the range of Mach numbers tested (0.8 to 1.0). Generally poor correlation, however, was confirmed with current linear theory prediction efforts. Failure to predict both the peak pressure levels and the shape was reported, especially with increasing tip Mach number.

Boxwell, D. A.↗

A proposed physical model for the impregnated tungsten cathode based on Auger surface studies of the Ba-O-W system

Auger spectra and work function measurements are used to study the surface reactions between tungsten surface and adsorbed layers of barium, and barium and oxygen. The barium on an impregnated tungsten cathod seems to be an intermediate state, probably a coadsorbed barium-oxygen layer on tungsten. A slightly revised version of the previously suggested (1976) impregnated tungsten cathode model is proposed. This revised model assumes that the cathode surface during life has an adsorbed surface layer of a monolayer or less of both barium and oxygen on the surface. At end of life, steep drop in electron emission and resultant cathode failure occur. Recent NASA life test results on TWT type tubes are reported and explained by the proposed model.

Forman, R.↗

Parametric instabilities of rotor-support systems with application to industrial ventilators

Rotor support systems interaction with parametric excitation is considered for both unequal principal shaft stiffness (generators) and offset disc rotors (ventilators). Instability regions and types of instability are computed in the first case, and parametric resonances in the second case. Computed and experimental results are compared for laboratory machine models. A field case study of parametric vibrations in industrial ventilators is reported. Computed parametric resonances are confirmed in field measurements, and some industrial failures are explained. Also the dynamic influence and gyroscopic effect of supporting structures are shown and computed.

Parszewski, Z.↗