At least 901 records · Page 50

Generating mock data sets for large-scale Lyman-α forest correlation measurements

Massive spectroscopic surveys of high-redshift quasars yield large numbers of correlated Lyα absorption spectra that can be used to measure large-scale structure. Simulations of these surveys are required to accurately interpret the measurements of correlations and correct for systematic errors. An efficient method to generate mock realizations of Lyα forest surveys is presented which generates a field over the lines of sight to the survey sources only, instead of having to generate it over the entire three-dimensional volume of the survey. The method can be calibrated to reproduce the power spectrum and one-point distribution function of the transmitted flux fraction, as well as the redshift evolution of these quantities, and is easily used for modeling any survey systematic effects. We present an example of how these mock surveys are applied to predict the measurement errors in a survey with similar parameters as the BOSS quasar survey in SDSS-III.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark-matter harmonics beyond annual modulation

The count rate at dark-matter direct-detection experiments should modulate annually due to the motion of the Earth around the Sun. We show that higher-frequency modulations, including daily modulation, are also present and in some cases are nearly as strong as the annual modulation. These higher-order modes are particularly relevant if (i) the dark matter is light, O(10) GeV, (ii) the scattering is inelastic, or (iii) velocity substructure is present; for these cases, the higher-frequency modes are potentially observable at current and ton-scale detectors. We derive simple expressions for the harmonic modes as functions of the astrophysical and geophysical parameters describing the Earth's orbit, using an updated expression for the Earth's velocity that corrects a common error in the literature. For an isotropic halo velocity distribution, certain ratios of the modes are approximately constant as a function of nuclear recoil energy. Anisotropic distributions can also leave observable features in the harmonic spectrum. Consequently, the higher-order harmonic modes are a powerful tool for identifying a potential signal from interactions with the Galactic dark-matter halo.

79 ASTRONOMY AND ASTROPHYSICS↗

High-speed Focal Plane Wave Front Sensing with an Optical Chopper

Focal plane wave front sensing and control is a critical approach to reducing noncommon path errors between a conventional astronomical adaptive optics (AO) wave front sensor (WFS) detector and a science camera. However, in addition to mitigating noncommon path errors, recent focal plane wave front sensing techniques have been developed to operate at speeds fast enough to enable "multi-WFS" AO, where residual atmospheric errors are further corrected by a focal plane WFS. Although a number of such techniques have been recently developed for coronagraphic imaging, here we present one designed for noncoronagraphic imaging. Utilizing conventional AO system components, this concept additionally requires (1) a detector imaging the focal plane of the WFS light source and (2) a pupil plane optical chopper device that is the noncommon path to the first WFS and is synchronized to the focal plane imager readout. These minimal hardware requirements enable the temporal amplitude modulation to resolve the sine ambiguity of even wave-front modes for low, mid, and high wave front spatial frequencies. Similar capabilities have been demonstrated with classical phase diversity by defocusing the detector, but such techniques are incompatible with simultaneous science observations. This optical chopping technique, however, enables science imaging at up to 50% duty cycle. In conclusion, we present both simulations and laboratory validation of this concept on SEAL, the Santa Cruz Extreme AO Laboratory testbed.

79 ASTRONOMY AND ASTROPHYSICS↗

RAPID INFRARED VARIABILITY OF THREE RADIO-LOUD NARROW-LINE SEYFERT 1 GALAXIES: A VIEW FROM THE WIDE-FIELD INFRARED SURVEY EXPLORER

Using newly released data from the Wide-field Infrared Survey Explorer, we report the discovery of rapid infrared variability in three radio-loud narrow-line Seyfert 1 galaxies (NLS1s) selected from the 23 sources in the sample of Yuan et al. J0849+5108 and J0948+0022 clearly show intraday variability, while J1505+0326 has a longer measurable timescale within 180 days. Their variability amplitudes, corrected for measurement errors, are {approx}0.1-0.2 mag. The detection of intraday variability restricts the size of the infrared-emitting region to {approx}10{sup -3} pc, significantly smaller than the scale of the torus but consistent with the base of a jet. The three variable sources are exceptionally radio-loud, have the highest radio brightness temperature among the whole sample, and all show detected {gamma}-ray emission in Fermi/LAT observations. Their spectral energy distributions resemble those of low-energy-peaked blazars, with a synchrotron peak around infrared wavelengths. This result strongly confirms the view that at least some radio-loud NLS1s are blazars with a relativistic jet close to our line of sight. The beamed synchrotron emission from the jet contributes significantly to and probably dominates the spectra in the infrared and even optical bands.

79 ASTRONOMY AND ASTROPHYSICS↗

5-Formylcytosine mediated DNA–protein cross-links block DNA replication and induce mutations in human cells

Nucleic Acids Research, 46(13):6455–6469, https://doi.org/10.1093/nar/gky444. There was a typographical error on page 6458, column 1, line 12 and on page 6459, column 2, line 53. In both instances, dNTP concentrations should be listed as ‘5, 10, 25, 50, 100, 150, 250, 500 μM’. The same error has been corrected in the labels of Supplementary Figure S2. These typos do not affect the kinetics parameters listed in Table 2 and do not influence the results and conclusions of the article. The article and supplementary file have been updated.

59 BASIC BIOLOGICAL SCIENCES↗

Universal and nonuniversal features of Bardeen-Cooper-Schrieffer theory with finite-range interactions

Here, we study analytic solutions to the Bardeen-Cooper-Schrieffer (BCS) gap equation for isotropic superconductors with finite-range interaction potentials over the full range of temperatures from absolute zero to the superconducting critical temperature 0 ≤ T ≤ T c . Using these solutions Δ (ε,T), we provide a proof of the universality of the temperature dependence of the BCS gap ratio at the Fermi level Δ (ε = 0,T)/T c . Moreover, by examining the behavior of this ratio as a function of energy ε, we find that nonuniversal features emerge away from the Fermi level, and these features take the form of a temperature-independent multiplicative factor F(ε), which is equal to Δ (ε,T)/Δ(ε = 0,T) up to exponentially small corrections, i.e., the error terms vanish like e -1/λ in the weak-coupling limit λ → 0. We discuss the model-dependent features of both F(ε) and T c , and we illustrate their behavior focusing on several concrete examples of physically relevant finite-range potentials. Comparing these cases for fixed coupling constants, we highlight the importance of the functional form of the interaction potential in determining the size of the critical temperature and provide guidelines for choosing potentials which lead to higher values of T c . We also propose experimental signatures which could be used to probe the energy dependence of the gap and potentially shed light on the underlying mechanisms giving rise to superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of Collins effect in the single spin asymmetry A{sub N} in p(transv. Polarized) p --> h X processes

The much debated issue of the transverse single spin asymmetry A{sub N} observed in the inclusive large P{sub T} production of a single hadron in pp interactions, p(transv. polarized) p --> {pi} X, is considered in a Transverse Momentum Dependent factorization scheme. A previous result stating that the maximum contribution of the Collins effect is strongly suppressed, is revisited, correcting a numerical error. New estimates are given, adopting the Collins functions recently extracted from Semi-Inclusive Deep Inelastic Scattering and e{sup +}e{sup -} data, and phenomenological consequences are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analyzing diffuse scattering with supercomputers. Corrigendum

The study by Michels-Clark et al. (2013 [Michels-Clark, T. M., Lynch, V. E., Hoffmann, C. M., Hauser, J., Weber, T., Harrison, R. & Bürgi, H. B. (2013). J. Appl. Cryst. 46, 1616-1625.]) contains misleading errors which are corrected here. The numerical results reported in that paper and the conclusions given there are not affected and remain unchanged. The transition probabilities in Table 1 (rows 4, 5, 7, 8) and Fig. 2 (rows 1 and 2) of the original paper were different from those used in the numerical calculations. Corrected transition probabilities as used in the computations are given in Table 1 and Fig. 1 of this article. The Δ parameter in the stacking model expresses the preference for the fifth layer in a five-layer stack to be eclipsed with respect to the first layer. This statement corrects the original text on p. 1622, lines 4–7. In the original Fig. 2 the helicity of the layer stacks b L and b R in rows 3 and 4 had been given as opposite to those in rows 1, 2 and 5. Fig. 1 of this article shows rows 3 and 4 corrected to correspond to rows 1, 2 and 5.

97 MATHEMATICS AND COMPUTING↗

Defects in Na-, K-, and Cd-Doped CuInSe$_2$ : Canonical Thermodynamics Based on Ab Initio Calculations

In this work. we extend a canonical-thermodynamic method for computing intrinsic point defect concentrations as a function of chemical stoichiometry and temperature to include extrinsic defect contributions, while applying this method to study defects in CuInSe 2 . This technique relies on a large set of defect formation energies calculated from first principles, which require corrections for known errors arising from spurious interactions. Guided by recent experimental work exhibiting the complex interplay between Na, K, and Cd incorporation, we examine the behavior of dominant defects as the material composition varies under experimentally relevant conditions. In addition to identifying the regions of composition-parameter space relevant to the incorporation of impurities Na, K, and Cd, and stable against the formation of secondary compounds, we further study defect kinetics susceptible to the presence of these impurities. From this analysis, we propose a simple model for the enhanced diffusion of Cu-vacancies mediated by K, which could lead to the enhanced incorporation of Cd observed experimentally.

42 ENGINEERING↗

Emerging Techniques for Field Device Security

Critical infrastructure, such as electrical power plants and oil refineries, rely on embedded devices to control essential processes. State of the art security is unable to detect attacks on these devices at the hardware or firmware level. We provide an overview of the hardware used in industrial control system field devices, look at how these devices have been attacked, and discuss techniques and new technologies that may be used to secure them. We follow three themes: (1) Inspectability, the capability for an external arbiter to monitor the internal state of a device. (2) Trustworthiness, the degree to which a system will continue to function correctly despite disruption, error, or attack. (3) Diversity, the use of adaptive systems and complexity to make attacks more difficult by reducing the feasible attack surface.

97 MATHEMATICS AND COMPUTING↗

Radiochromic EBT2 film dosimetry for low-energy protontherapy

Purpose: In protontherapy, accessories are used in order to adapt the beam to the surface and to the depth of the target. They are positioned close to the patient in order to avoid perturbation effects related to proton scattering. The level of contamination of the beam caused by these accessories may be assessed by examining the dose maps in parallel planes to the beam incidence. The EBT2 radiochromic film is a suitable tool for this task, as it can be cut into small pieces and immersed in water. Prior to use the EBT2 film for dose measurements, its response when exposed to a proton beam must be analysed. Methods: The measurements were performed at the Centre Antoine Lacassagne, using the hospital-based MEDICYC isochronous cyclotron which provides 65 MeV protons. Monoenergetic as well as polyenergetic beams were used. Small pieces of EBT2 films were irradiated with proton beams in a small water phantom. Films were exposed at various angles close to the beam incidence and received doses ranging from 0.25 to 500 Gy. The optical density (OD) was studied as a function of angle, dose and linear energy transfer (LET). Results: The effective atomic number of the active layer of the film is close to that of water which prevents disturbances of the measurement. However, the high density and the significant thickness of the Mylar substrate surrounding the active layer affect the use of the film in a parallel orientation to the beam. Therefore, the substrate layer may totally or partially slow down the protons. The measurement is then no longer representative to what happens in water. The measurement errors can be corrected by applying a tilt angle of at least 5 deg. between the film and the beam. The dose analysis reveals that the green channel is the most sensitive in the dose range from 1 to 100 Gy. The OD is accurately described by a Weibull function of the dose with four free parameters. The Weibull function is valid for both monoenergetic and polyenergetic beams if the LET is limited to values below 15 MeV g{sup -1} cm{sup 2}. When using a film orientation close to the beam incidence angle, increasing LET values are encountered throughout the film axis gradually with the protons slowing down in water. The EBT2 films show an underestimated response for higher LET values. The comparison of data from the present study to data obtained by other authors for EBT films allows modelling the underestimated response as a function of the LET. The definition improvement of the link between OD and LET requires to integrate more closely the beam energy characteristics. Conclusions: The EBT2 film is a suitable dosimeter for analysing dose plans in planes nearly parallel to the beam orientation by compensating the underestimated dose response due to LET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-based PSF and MTF estimation and validation from skeletal clinical CT images

Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the scanner-specific parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-637: Single-Isocenter Versus Multiple-Isocenter VMAT SRS for Unusual Multiple Metastasis Case with Two Widely Separated Lesions

Purpose: Single-isocenter (SI) volumetric modulated arc therapy has been shown to be an effective and efficient approach to multiple metastasis radiosurgery. However, certain extreme cases raise the question of whether multiple-isocenter (MI) approaches can still generate superior plans. In this study, we ask this question with respect to a clinical case with two very widely separated lesions. Methods: A patient with two widely separated (d = 12cm) tumors was treated with SI-VMAT SRS using 10MV flattening filter free (FFF) beam with high-definition multi-leaf collimator (HD-MLC, 2.5/5mm) in two non-coplanar arcs using concentric rings to enforce steep gradient. Because of lesion positioning with respect to collimator angle selection, lesions were treated by 5mm leaves. We re-planned the case with a congruent arc arrangement but separate isocenter for each lesion. In this manner, lesions were treated by 2.5mm leaves. Conformity index (CI), V50%, and mean brain dose were compared. Results: Neither conformity (CI-SI = 1.12, CI-MI = 1.08) nor V50% (V50%-SI =8.82cc, V50%-MI =8.81cc) were improved by utilizing a separate isocenter for each lesion. Mean brain dose was slightly reduced (dmean-SI = 118.4 cGy, dmean-MI = 88.7 cGy) by using multiple isocenters. Conclusion: For this case with a lesion at the apex of the brain and another distantly located at the base of skull, employing a separate isocenter for each target did not meaningfully improve plan quality. Single-isocenter VMAT has been shown feasible and equivalent to multiple-isocenter VMAT for multiple metastasis cases in general. In this extreme case, single- and multiple- isocenter VMAT were also equivalent. If rotational setup errors are appropriately corrected, the increased delivery efficiency of the single-isocenter approach renders it preferable to the multiple isocenter approach. Dr’s Thomas, Popple, and Fiveash have all received honoraria from Varian Medical Systems for discussing their experiences with stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-13: Patient-Specific Reduction of Range Uncertainties in Proton Therapy by Proton Radiography with a Multi-Layer Ionization Chamber

Purpose: The conversion from Hounsfield units (HU) to stopping powers is a major source of range uncertainty in proton therapy (PT). Our contribution shows how proton radiographs (PR) acquired with a multi-layer ionization chamber in a PT center can be used for accurate patient positioning and subsequently for patient-specific optimization of the conversion from HU to stopping powers. Methods: A multi-layer ionization chamber was used to measure the integral depth-dose (IDD) of 220 MeV pencil beam spots passing through several anthropomorphic phantoms. The whole area of interest was imaged by repositioning the couch and by acquiring a 45×45 mm{sup 2} frame for each position. A rigid registration algorithm was implemented to correct the positioning error between the proton radiographs and the planning CT. After registration, the stopping power map obtained from the planning CT with the calibration curve of the treatment planning system was used together with the water equivalent thickness gained from two proton radiographs to generate a phantom-specific stopping power map. Results: Our results show that it is possible to make a registration with submillimeter accuracy from proton radiography obtained by sending beamlets separated by more than 1 mm. This was made possible by the complex shape of the IDD due to the presence of lateral heterogeneities along the path of the beam. Submillimeter positioning was still possible with a 5 mm spot spacing. Phantom specific stopping power maps obtained by minimizing the range error were cross-verified by the acquisition of an additional proton radiography where the phantom was positioned in a random but known manner. Conclusion: Our results indicate that a CT-PR registration algorithm together with range-error based optimization can be used to produce a patient-specific stopping power map. Sylvain Deffet reports financial funding of its PhD thesis by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work. Francois Vander Stappen reports being employed by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work.

60 APPLIED LIFE SCIENCES↗

Erratum to: Permanent draft genome of Thermithiobacillus tepidarius DSM 3134T, a moderately thermophilic, obligately chemolithoautotrophic member of the Acidithiobacillia

The errors and associated corrections described in this document concerning the original manuscript were accountable to the production department handling this manuscript, and thus are no fault of the authors of this paper. Additionally, the online manuscript has now been updated with these corrections accordingly. In the original publication of this article, the title was displayed incorrectly as "Permanent draft genome of Thermithiobaclillus tepidarius DSM 3134T, a moderately thermophilic, obligately chemolithoautotrophic member of the Acidithiobacillia". The genus name "Thermithiobacillus" was misspelt as "Thermithiobaclillus". This has now been corrected in the original article.

59 BASIC BIOLOGICAL SCIENCES↗

Real-time measurement of parametric influences on the refractive index and length changes in silica optical fibers

In this paper, we present a simple cascaded Fabry-Perot interferometer (FPI) that can be used to measure in real-time the refractive index (RI) and length variation in silica optical fibers caused due to external physical parameters, such as temperature, strain, and radiation. As a proof-of-concept, we experimentally demonstrate real-time monitoring of temperature effects on the RI and length and measure the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) by using the cascaded FPI within a temperature range of 21–486°C. The experimental results provide a TEC of 5.53 × 10 −7 /°C and TOC of 4.28 × 10 −6 /°C within the specified temperature range. Such a simple cascaded FPI structure will enable the design of optical sensors to correct for measurement errors by understanding the change in RI and length of optical fiber caused by environment parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Entanglement-based quantum digital signatures over a deployed campus network: erratum

We correct a minor error in Table 1 and a related minor error in the simulations of the improved system. These revisions result in minor changes to Fig. 6 and Table 1 in [ Opt. Express 32 , 7521 ( 2024 ) 10.1364/OE.510787 ]. These changes do not affect the experimental measurements or the conclusions of the work.

Chapman, Joseph C. (ORCID:0000000233460914)↗