Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “enhanced”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

The quantum mechanics of ion-enhanced field emission and how it influences microscale gas breakdown

The presence of a positive gas ion can enhance cold electron field emission by deforming the potential barrier and increasing the tunneling probability of electrons—a process known as ion-enhanced field emission. In microscale gas discharges, ion-enhanced field emission produces additional emission from the cathode and effectively reduces the voltage required to breakdown a gaseous medium at the microscale (<10 μm). In this work, we enhance classic field emission theory by determining the impact of a gaseous ion on electron tunneling and compute the effect of ion-enhanced field emission on the breakdown voltage. We reveal that the current density for ion-enhanced field emission retains the same scaling as vacuum cold field emission and that this leads to deviations from traditional breakdown theory at microscale dimensions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly enhanced green emission from InGaN quantum wells due to surface plasmon resonance on aluminum films

Photoluminescence (PL) from InGaN/GaN quantum wells was highly enhanced by the surface plasmon (SP) resonance on aluminum thin films. The enhancement ratio of green emission reached 80, which was much larger than the previously reported enhancements on silver films. The resulting large enhancement should be attributed to an ∼20-fold enhancement of the excitation efficiency and ∼4-fold enhancement of the emission efficiency by the excitation and emission spectra. The temperature dependence of the PL intensities and the time-resolved PL measurements were also performed to understand the detailed mechanism. We concluded that the resonance between the excitation light and the SP on the Al surface should improve the excitation efficiency, i.e., the light absorption efficiency. This result suggests that the Al films have an extraordinary photon confinement effect, which are unique properties of plasmonics with Al and should be useful for new and wider applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Enhancement of phonon backscattering due to confinement of ballistic phonon pathways in silicon as studied with a microfabricated phonon spectrometer

In this work, the mechanism for enhanced phonon backscattering in silicon is investigated. An understanding of phonon propagation through substrates has implications for engineering heat flow at the nanoscale, for understanding sources of decoherence in quantum systems, and for realizing efficient phonon-mediated particle detectors. In these systems, phonons that backscatter from the bottom of substrates, within the crystal or from interfaces, often contribute to the overall detector signal. We utilize a microscale phonon spectrometer, comprising superconducting tunnel junction emitters and detectors, to specifically probe phonon backscattering in silicon substrates (∼500 μm thick). By etching phonon “enhancers” or deep trenches (∼90 μm) around the detectors, we show that the backscattered signal level increases by a factor of ∼2 for two enhancers versus one enhancer. Using a geometric analysis of the phonon pathways, we show that the mechanism of the backscattered phonon enhancement is due to confinement of the ballistic phonon pathways and increased scattering off the enhancer walls. Our result is applicable to the geometric design and patterning of substrates that are employed in phonon-mediated detection devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the relationship between electric field enhancement and plasmon-driven electron transfer

Plasmonic materials interact strongly with light to create localized, out-of-equilibrium environments with intense electromagnetic fields known as hotspots. After forming, hotspots dissipate energy into their surroundings and can transfer energy and charge carriers to nearby molecules, giving plasmonic materials the potential to drive reactions with sunlight. However, the field needs a better mechanistic understanding of plasmon–molecule interactions and how the local plasmon environment, specifically the electromagnetic field enhancement and spatial distribution of hotspots, impacts the reaction yield. Here, in this work, we mapped plasmon-driven charge transfer across ordered plasmonic substrates using diffraction-limited surface-enhanced Raman spectroscopy (SERS) microscopy to understand the relationship between the average local electric field enhancement and charge transfer reaction yield. We tracked the plasmon-induced electron transfer to buckminsterfullerene (C 60 ) and found that areas with the greatest SERS intensity were not the areas with the greatest ensemble-averaged reduction of C 60 , suggesting that areas with higher electric field enhancement—or “hotter,” more enhancing hotspots—do not improve the charge transfer reaction yield. This work shows that efforts to improve plasmon-driven charge transfer should not merely focus on creating substrates with extremely enhancing regions but also consider how other factors could optimize photoreduction yields.

Koble, MaKenna M. [Univ. of Minnesota, Minneapolis↗

Distant-acting Enhancers in Development and Disease

Multiple converging lines of evidence from experimental and human genetic studies indicate that both common and rare sequence variants involving enhancers play major roles in Mendelian and complex human disease phenotypes. We use a combination of sequence-based molecular approaches including chromatin mapping and synthesis-enabled modification of enhancer sequences, large-scale transgenic mouse studies (http://enhancer.lbl.gov), and CRISPR genome editing in the mouse model to study the in vivofunction of enhancers in developmental, evolutionary, and disease-related processes. Using examples from our ongoing work, I will illustrate how these methods provide insight into the function and evolution of distant-acting regulatory sequences and offer a starting point for understanding their role in human disease. I will discuss how improved in vivo mouse assays can be used to study candidate pathogenic human mutations in enhancers at scale, revealing the extent to which human genetic studies alone can be insufficient to identify truly causal mutations in enhancers. I will also show how such assays can be used to explore the sensitivity of enhancers that are extremely conserved ("ultraconserved") in evolution to mutations, revealing a remarkable functional robustness to sequence changes that contrasts with apparent evolutionary constraints.

Visel, A↗

Coherent anti-Stokes Raman scattering with squeezed light: CARS for quantum-enhanced spectroscopy and imaging

We theoretically investigate quantum-enhanced coherent anti-Stokes Raman scattering (CARS) using squeezed light to amplify vibrational transition rates at low photon flux. Quantum sensing approaches are needed for nondestructive nanometrology such as in bioimaging where reduced photodamage is desired while retaining resolution and sensitivity. We analyze both single-mode squeezing applied to the pump field and two-mode squeezing between the pump and Stokes fields. We also show that the ordering of displacement and squeezing operations—whether displacement precedes squeezing or squeezing precedes displacement—has an impact on the resulting CARS transition amplitudes due to a difference in the photon number and the quantum-enhancement coefficients, with the latter offering a stronger enhancement in the case of two modes squeezing of the pump and Stokes under experimentally accessible conditions. Furthermore, our calculations capture these quantum enhancements through the intrinsic photon-number correlations of squeezed light, eliminating the need for interferometric detection or higher pump powers that are otherwise required to reach comparable sensitivities in classical CARS. Finally, we outline a quantum plasmonic extension of our model in which local field enhancements caused by surface plasmon excitation in metallic nanoparticles can be incorporated via mode-selective field amplification factors, offering a pathway toward combining squeezed-light quantum optics with surface-enhanced nanoscale spectroscopy and imaging.

Atomic & molecular structure↗

Theory of plasmon-enhanced high-order harmonic generation in the vicinity of metal nanostructures in noble gases

We present a semiclassical model for plasmon-enhanced high-order harmonic generation (HHG) in the vicinity of metal nanostructures. We show that, besides the field enhancement, both the inhomogeneity of the enhanced local fields and electron absorption by the metal surface play an important role in the HHG process and lead to the generation of even harmonics and a significantly increased cutoff. For the examples of silver-coated nanocones and bowtie antennas, we predict that the required intensity reduces by up to three orders of magnitude due to plasmonic field enhancement. The study of the enhanced high-order harmonic generation is connected with a finite-element simulation of the electric field enhancement due to the excitation of the plasmonic modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temporal enhancement of super-horizon curvature perturbations from decays of two curvatons and its cosmological consequences

If more than one curvaton dominate the Universe at different epochs from each other, curvature perturbations can be temporarily enhanced to a value much larger than the observed one 10{sup -5}. The traces of the enhancement may be left as higher order correlation functions, that is, as non-Gaussianity, the stochastic gravitational waves that are sourced by scalar-scalar mode couplings, as well as the primordial black holes that are formed by the gravitational collapse of the enhanced curvature perturbations. We first confirm that such a temporal enhancement indeed occurs by solving the linearized perturbation equations both numerically and analytically. We then derive an analytic expression of the full-order curvature perturbation which does not rely on the frequently used sudden decay approximation and is exact on superhorizon scales. By using this analytic formula, we provide expressions of the nonlinearity parameters f{sub NL}, {tau}{sub NL} and g{sub NL}. If both two curvatons contribute to the final curvature perturbations, the strong non-Gaussianity appears in the trispectrum rather than in the bispectrum. We also find a unique consistency relation between {tau}{sub NL} and g{sub NL} without f{sub NL}. By using the second-order perturbation theory, we numerically show that the spectrum of the induced gravitational waves has a plateau corresponding to duration of the enhancement and such gravitational waves can be probed by ultimate-DECIGO and space-based atomic interferometers. We finally calculate the abundance of the primordial black holes and put a constraint on the amplitude of the enhanced curvature perturbations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving OFDR Distributed Fiber Sensing by Fibers With Enhanced Rayleigh Backscattering and Image Processing

This article investigates using optical fibers with enhanced backscattering profiles to improve distributed fiber sensor performance and reduce instrumentation costs. Using a femtosecond (fs) laser direct writing technique, the Rayleigh backscattering profile of a standard telecom fiber was enhanced by more than 40 dB to improve the signal-to-noise ratio (SNR) for optical frequency domain reflectometry (OFDR). The enhanced backscattering signals enable effectively distributed strain measurements using a low-cost tunable laser (TL). Median filtering is applied to denoise cross correlation results to further improve measurement outcomes. Results presented in this article show that a TL with a 1-nm tuning range, which is far less than the tuning range used in commercial OFDR interrogators, can perform effectively distributed strain measurements using sensing fibers with enhanced backscattering profiles. The sensing fiber with over 40-dB backscattering enhancement achieved 4.8-cm spatial resolution in strain measurements with a root mean square accuracy of less than 2.70 με when 10–50 με were exerted to the sensing fiber. In conclusion, results presented in this article reveal both the potential and limitations of sensing fibers with enhanced backscattering for OFDR-based distributed fiber sensors.

42 ENGINEERING↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma-enhanced and thermal atomic layer deposition of Al{sub 2}O{sub 3} using dimethylaluminum isopropoxide, [Al(CH{sub 3}){sub 2}({mu}-O{sup i}Pr)]{sub 2}, as an alternative aluminum precursor

The authors have been investigating the use of [Al(CH{sub 3}){sub 2}({mu}-O{sup i}Pr)]{sub 2} (DMAI) as an alternative Al precursor to [Al(CH{sub 3}){sub 3}] (TMA) for remote plasma-enhanced and thermal ALD over wide temperature ranges of 25-400 and 100-400 deg. C, respectively. The growth per cycle (GPC) obtained using in situ spectroscopic ellipsometry for plasma-enhanced ALD was 0.7-0.9 A/cycle, generally lower than the >0.9 A/cycle afforded by TMA. In contrast, the thermal process gave a higher GPC than TMA above 250 deg. C, but below this temperature, the GPC decreased rapidly with decreasing temperature. Quadrupole mass spectrometry data confirmed that both CH{sub 4} and HO{sup i}Pr were formed during the DMAI dose for both the plasma-enhanced and thermal processes. CH{sub 4} and HO{sup i}Pr were also formed during the H{sub 2}O dose but combustion-like products (CO{sub 2} and H{sub 2}O) were observed during the O{sub 2} plasma dose. Rutherford backscattering spectrometry showed that, for temperatures >100 deg. C and >200 deg. C for plasma-enhanced and thermal ALD, respectively, films from DMAI had an O/Al ratio of 1.5-1.6, a H content of {approx}5 at. % and mass densities of 2.7-3.0 g cm{sup -3}. The film compositions afforded from DMAI were comparable to those from TMA at deposition temperatures {>=}150 deg. C At lower temperatures, there were differences in O, H, and C incorporation. 30 nm thick Al{sub 2}O{sub 3} films from the plasma-enhanced ALD of DMAI were found to passivate n- and p-type Si floatzone wafers ({approx}3.5 and {approx}2 {Omega} cm, respectively) with effective carrier lifetimes comparable to those obtained using TMA. Surface recombination velocities of < 3 and < 6 cm s{sup -1} were obtained for the n- and p-type Si, respectively. Using these results, the film properties obtained using DMAI and TMA are compared and the mechanisms for the plasma-enhanced and thermal ALD using DMAI are discussed.

36 MATERIALS SCIENCE↗

Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography

Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten K{alpha} emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor increases from 2.2 to 2.4 by using quasi-monochromatic instead of polychromatic radiation. An additional increase in the radiation dose by a factor of 1.4 due to the focusing characteristic of the x-ray optical module was calculated. Photoelectric-enhanced radiation therapy based on a clinical CT unit combined with an x-ray optical module is a novel therapy option in radiation oncology. The optimized quasi-monochromatic radiation is strongly focused and ensures high photoelectric dose enhancement for iodine.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effect of flattening filter free delivery on endothelial dose enhancement with gold nanoparticles

Purpose: The aim of this study is to quantify and to compare the dose enhancement factor from gold nanoparticles (AuNP) to tumor endothelial cells for different concentrations of AuNP, and clinical MV beam configurations. Methods: Tumor endothelial cells are modeled as slabs measuring 10 Multiplication-Sign 10 Multiplication-Sign 2 {mu}m. A spherical AuNP is simulated on the surface of the endothelial cell, within the blood vessel. 6 MV photon beams with and without the flattening filter are investigated for different field sizes, depths in material and beam modulation. The incident photon energy spectra for each configuration is generated using EGSnrc. The dose enhancement in the tumor endothelial cell is found using an analytical calculation. The endothelial dose enhancement factor is defined to be the ratio of the dose deposited with and without AuNPs. Results: It is found that clinical beam parameters may be chosen to maximize the effect of gold nanoparticles during radiotherapy. This effect is further amplified {approx}20% by the removal of the flattening filter. Modulation of the clinical beam with the multileaf collimator tends to decrease the proportion of low energy photons, therefore providing less enhancement than the corresponding open field. Conclusions: The results of this work predict a dose enhancement to tumor blood vessel endothelial cells using conventional therapeutic (MV) x-rays and quantify the relative change in enhancement with treatment depth and field size.

60 APPLIED LIFE SCIENCES↗

SU-E-T-231: Measurements of Gold Nanoparticle-Mediated Proton Dose Enhancement Due to Particle-Induced X-Ray Emission and Activation Products Using Radiochromic Films and CdTe Detector

Purpose: There have been several reports of enhanced cell-killing and tumor regression when tumor cells and mouse tumors were loaded with gold nanoparticles (GNPs) prior to proton irradiation. While particle-induced xray emission (PIXE), Auger electrons, secondary electrons, free radicals, and biological effects have been suggested as potential mechanisms responsible for the observed GNP-mediated dose enhancement/radiosensitization, there is a lack of quantitative analysis regarding the contribution from each mechanism. Here, we report our experimental effort to quantify some of these effects. Methods: 5-cm-long cylindrical plastic vials were filled with 1.8 mL of either water or water mixed with cylindrical GNPs at the same gold concentration (0.3 mg Au/g) as used in previous animal studies. A piece of EBT2 radiochromic film (30-µm active-layer sandwiched between 80/175-µm outer-layers) was inserted along the long axis of each vial and used to measure dose enhancement due to PIXE from GNPs. Vials were placed at center-of-modulation (COM) and 3-cm up-/down-stream from COM and irradiated with 5 different doses (2–10 Gy) using 10-cm-SOBP 160-MeV protons. After irradiation, films were cleaned and read to determine the delivered dose. A vial containing spherical GNPs (20 mg Au/g) was also irradiated, and gamma-rays from activation products were measured using a cadmium-telluride (CdTe) detector. Results: Film measurements showed no significant dose enhancement beyond the experimental uncertainty (∼2%). There was a detectable activation product from GNPs, but it appeared to contribute to dose enhancement minimally (<0.01%). Conclusion: Considering the composition of EBT2 film, it can be inferred that gold characteristic x-rays from PIXE and their secondary electrons make insignificant contribution to dose enhancement. The current investigation also suggests negligible dose enhancement due to activation products. Thus, previously-reported GNP-mediated proton dose enhancement/radiosensitization needs to be attributed to one or more of the other mechanisms listed earlier. Supported in part by NIH/NCI grant R01CA155446;This investigation was supported in part by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

SU-E-T-235: Monte Carlo Analysis of the Dose Enhancement in the Scalp of Patients Due to Titanium Plate Backscatter During Post-Operative Radiotherapy

Purpose: To quantify the clinically observed dose enhancement adjacent to cranial titanium fixation plates during post-operative radiotherapy. Methods: Irradiation of a titanium burr hole cover was simulated using Monte Carlo code MCNPX for a 6 MV photon spectrum to investigate backscatter dose enhancement due to increased production of secondary electrons within the titanium plate. The simulated plate was placed 3 mm deep in a water phantom, and dose deposition was tallied for 0.2 mm thick cells adjacent to the entrance and exit sides of the plate. These results were compared to a simulation excluding the presence of the titanium to calculate relative dose enhancement on the entrance and exit sides of the plate. To verify simulated results, two titanium burr hole covers (Synthes, Inc. and Biomet, Inc.) were irradiated with 6 MV photons in a solid water phantom containing GafChromic MD-55 film. The phantom was irradiated on a Varian 21EX linear accelerator at multiple gantry angles (0–180 degrees) to analyze the angular dependence of the backscattered radiation. Relative dose enhancement was quantified using computer software. Results: Monte Carlo simulations indicate a relative difference of 26.4% and 7.1% on the entrance and exit sides of the plate respectively. Film dosimetry results using a similar geometry indicate a relative difference of 13% and -10% on the entrance and exit sides of the plate respectively. Relative dose enhancement on the entrance side of the plate decreased with increasing gantry angle from 0 to 180 degrees. Conclusion: Film and simulation results demonstrate an increase in dose to structures immediately adjacent to cranial titanium fixation plates. Increased beam obliquity has shown to alleviate dose enhancement to some extent. These results are consistent with clinically observed effects.

60 APPLIED LIFE SCIENCES↗

SU-E-T-211: Comparison of Seven New TrueBeam Linacs with Enhanced Beam Data Conformance Using a Beam Comparison Software Tool

Purpose: To develop an independent software tool to assist in commissioning linacs with enhanced beam conformance, as well as perform ongoing QA for dosimetrically equivalent linacs. Methods: Linac manufacturers offer enhanced beam conformance as an option to allow for clinics to complete commissioning efficiently, as well as implement dosimetrically equivalent linacs. The specification for enhanced conformance includes PDD as well as profiles within 80% FWHM. Recently, we commissioned seven Varian TrueBeam linacs with enhanced beam conformance. We developed a software tool in Visual Basic to allow us to load the reference beam data and compare our beam data during commissioning to evaluate enhanced beam conformance. This tool also allowed us to upload our beam data used for commissioning our dosimetrically equivalent beam models to compare and tweak each of our linac beams to match our modelled data in Varian’s Eclipse TPS. This tool will also be used during annual QA of the linacs to compare our beam data to our baseline data, as required by TG-142. Results: Our software tool was used to check beam conformance for seven TrueBeam linacs that we commissioned in the past six months. Using our tool we found that the factory conformed linacs showed up to 3.82% difference in their beam profile data upon installation. Using our beam comparison tool, we were able to adjust the energy and profiles of our beams to accomplish a better than 1.00% point by point data conformance. Conclusion: The availability of quantitative comparison tools is essential to accept and commission linacs with enhanced beam conformance, as well as to beam match multiple linacs. We further intend to use the same tool to ensure our beam data conforms to the commissioning beam data during our annual QA in keeping with the requirements of TG-142.

43 PARTICLE ACCELERATORS↗

Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study

Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: A total of eight clinical lung tumor cases were recalculated using Monte Carlo methods, and external magnetic fields of 0.5, 1.0, and 3 T were included to observe the impact on dose to the planning target volume (PTV) and gross tumor volume (GTV). Three plans were 6 MV 3D-CRT plans while 6 were 6 MV IMRT. The GTV’s ranged from 0.8 to 16 cm{sup 3}, while the PTV’s ranged from 1 to 59 cm{sup 3}. In addition, the dose changes in a 30 cm diameter cylindrical water phantom were investigated for small beams. The central 20 cm of this phantom contained either water or lung density insert. Results: For single beams, an inline magnetic field of 1 T has a small impact in lung dose distributions by reducing the lateral scatter of secondary electrons, resulting in a small dose increase along the beam. Superposition of multiple small beams leads to significant dose enhancements. Clinically, this process occurs in the lung tissue typically surrounding the GTV, resulting in increases to the D{sub 98%} (PTV). Two isolated tumors with very small PTVs (3 and 6 cm{sup 3}) showed increases in D{sub 98%} of 23% and 22%. Larger PTVs of 13, 26, and 59 cm{sup 3} had increases of 9%, 6%, and 4%, describing a natural fall-off in enhancement with increasing PTV size. However, three PTVs bounded to the lung wall showed no significant increase, due to lack of dose enhancement in the denser PTV volume. In general, at 0.5 T, the GTV mean dose enhancement is around 60% lower than that at 1 T, while at 3 T, it is 5%–60% higher than 1 T. Conclusions: Monte Carlo methods have described significant and predictable dose enhancement effects in small lung tumor plans for 6 MV radiotherapy when an external inline magnetic field is included. Results of this study indicate that future clinical inline MRI-guided radiotherapy systems will be able to deliver a dosimetrically superior treatment to small (PTV < 15 cm{sup 3}), isolated lung tumors over non-MRI-Linac systems. This increased efficacy coincides with the reimbursement in the United States of lung CT screening and the likely rapid growth in the number of patients with small lung tumors to be treated with radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-426: Measurement of Dose Enhancement Due to Backscatter From Modern Dental Materials

Purpose: High-density materials used in dental restoration can cause significant localized dose enhancement due to electron backscatter in head-and-neck radiotherapy, increasing the risk of mucositis. The materials used in prosthetic dentistry have evolved in the last decades from metal alloys to ceramics. We aim to determine the dose enhancement caused by backscatter from currently-used dental materials. Methods: Measurements were performed for three different dental materials: lithium disilicate (Li{sub 2}Si{sub 2}O{sub 5}), zirconium dioxide (ZrO{sub 2}), and gold alloy. Small thin squares (2×2×0.15 cm{sup 3}) of the material were fabricated, and placed into a phantom composed of tissue-equivalent material. The phantom was irradiated with a single 6 MV photon field. A thin-window parallel-plate ion chamber was used to measure the dose at varying distances from the proximal interface between the material and the plastic. Results: The dose enhancement at the interface between the high-density and tissue-equivalent materials, relative to a homogeneous phantom, was 54% for the gold alloy, 31% for ZrO{sub 2}, and 9% for Li{sub 2}Si{sub 2}O{sub 5}. This enhancement decreased rapidly with distance from the interface, falling to 11%, 5%, and 0.5%, respectively, 2 mm from the interface. Comparisons with the modeling of this effect in treatment planning systems are performed. Conclusion: While dose enhancement due to dental restoration is smaller with ceramic materials than with metal alloys, it can still be significant. A spacer of about 2–3 mm would be effective in reducing this enhancement, even for metal alloys.

60 APPLIED LIFE SCIENCES↗