Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Usefulness of Intraluminal Brachytherapy Combined With External Beam Radiation Therapy for Submucosal Esophageal Cancer: Long-Term Follow-Up Results

Purpose: To assess the efficacy of radiation therapy (RT) by using intraluminal brachytherapy (IBT) combined with external beam RT (EBRT) for submucosal esophageal cancer. Methods and Materials: Between 1991 and 2005, 59 consecutive patients received definitive RT without chemotherapy. IBT was performed after patients completed EBRT as a booster therapy for 17 patients, using low-dose-rate Cs-137 sources until 1997, and for 19 patients, using high-dose-rate Ir-192 sources thereafter. The long-term outcomes were investigated with a median follow-up time of 61 months. Results: Logoregional recurrences and distant metastases were observed in 14 patients and in 2 patients in the lung, respectively, and 5 patients were rescued by salvage treatments. The 5-year logoregional control and cause-specific survival rates were 75% and 76%, respectively. The 5-year cause-specific survival rate in the EBRT group was 62%, whereas the corresponding rate in the IBT group was 86% (p = 0.04). Multivariate analysis revealed that IBT was the most powerful predictor of survival but did not reach a significant level (p = 0.07). There were five esophageal ulcers in the IBT group, but no ulcers developed with small fractions of 3 Gy. Grade 2 or higher cardiorespiratory complications developed in 2 patients (5.6%) in the IBT group and in 3 patients (13.0%) in the EBRT group. Conclusions: Combining IBT with EBRT is suggested to be one of the preferable treatment modalities for medically inoperable submucosal esophageal cancer because of its preferable local control and survival probabilities, with appreciably less morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Permanent Iodine-125 Interstitial Planar Seed Brachytherapy for Close or Positive Margins for Thoracic Malignancies

Purpose: To assess toxicity and outcome following permanent iodine-125 seed implant as an adjunct to surgical resection in cases of advanced thoracic malignancy. Methods and Materials: An institutional review board-approved retrospective review was performed. Fifty-nine patients were identified as having undergone thoracic brachytherapy seed implantation between September 1999 and December 2006. Data for patient demographics, tumor details, and morbidity and mortality were recorded. Results: Fifty-nine patients received 64 implants. At a median follow-up of 17 months, 1-year and 2-year Kaplan-Meier rates of estimated overall survival were 94.1% and 82.0%, respectively. The 1-year and 2-year local control rates were 80.1% and 67.4%, respectively. The median time to develop local recurrence was 11 months. Grades 3 and 4 toxicity rates were 12% at 1 year. Conclusions: This review shows relatively low toxicity for interstitial planar seed implantation after thoracic surgical resection. The high local control results suggest that an incomplete oncologic surgery plus a brachytherapy implant for treating advanced thoracic malignancy merit further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Intraoperative Radiation Therapy for Recurrent Head-and-Neck Cancer

Purpose: To report the use of high-dose-rate intraoperative radiation therapy (HDR-IORT) for recurrent head-and-neck cancer (HNC) at a single institution. Methods and Materials: Between July 1998 and February 2007, 34 patients with recurrent HNC received 38 HDR-IORT treatments using a Harrison-Anderson-Mick applicator with Iridium-192. A single fraction (median, 15 Gy; range, 10-20 Gy) was delivered intraoperatively after surgical resection to the region considered at risk for close or positive margins. In all patients, the target region was previously treated with external beam radiation therapy (median dose, 63 Gy; range, 24-74 Gy). The 1- and 2-year estimates for in-field local progression-free survival (LPFS), locoregional progression-free survival (LRPFS), distant metastases-free survival (DMFS), and overall survival (OS) were calculated. Results: With a median follow-up for surviving patients of 23 months (range, 6-54 months), 8 patients (24%) are alive and without evidence of disease. The 1- and 2-year LPFS rates are 66% and 56%, respectively, with 13 (34%) in-field recurrences. The 1- and 2-year DMFS rates are 81% and 62%, respectively, with 10 patients (29%) developing distant failure. The 1- and 2-year OS rates are 73% and 55%, respectively, with a median time to OS of 24 months. Severe complications included cellulitis (5 patients), fistula or wound complications (3 patients), osteoradionecrosis (1 patient), and radiation-induced trigeminal neuralgia (1 patient). Conclusions: HDR-IORT has shown encouraging local control outcomes in patients with recurrent HNC with acceptable rates of treatment-related morbidity. Longer follow-up with a larger cohort of patients is needed to fully assess the benefit of this procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Health-Related Quality of Life up to Six Years After {sup 125}I Brachytherapy for Early-Stage Prostate Cancer

Purpose: Health-related quality of life (HRQOL) after prostate brachytherapy has been extensively described in published reports but hardly any long-term data are available. The aim of the present study was to prospectively assess long-term HRQOL 6 years after {sup 125}I prostate brachytherapy. Methods and Materials: A total of 127 patients treated with {sup 125}I brachytherapy for early-stage prostate cancer between December 2000 and June 2003 completed a HRQOL questionnaire at five time-points: before treatment and 1 month, 6 months, 1 year, and 6 years after treatment. The questionnaire included the RAND-36 generic health survey, the cancer-specific European Organization for Research and Treatment of Cancer core questionnaire (EORTCQLQ-C30), and the tumor-specific EORTC prostate cancer module (EORTC-PR25). A change in a score of >=10 points was considered clinically relevant. Results: Overall, the HRQOL at 6 years after {sup 125}I prostate brachytherapy did not significantly differ from baseline. Although a statistically significant deterioration in HRQOL at 6 years was seen for urinary symptoms, bowel symptoms, pain, physical functioning, and sexual activity (p <.01), most changes were not clinically relevant. A statistically significant improvement at 6 years was seen for mental health, emotional functioning, and insomnia (p <.01). The only clinically relevant changes were seen for emotional functioning and sexual activity. Conclusion: This is the first study presenting prospective HRQOL data up to 6 years after {sup 125}I prostate brachytherapy. HRQOL scores returned to approximately baseline values at 1 year and remained stable up to 6 years after treatment. {sup 125}I prostate brachytherapy did not adversely affect patients' long-term HRQOL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Biochemical and Survival Outcome of 921 Patients Treated With I-125 Permanent Prostate Brachytherapy

Purpose: To assess long-term biochemical and survival outcome after permanent prostate brachytherapy (BT). Methods and Materials: Data on 921 patients, treated with permanent interstitial BT monotherapy between 1989 and 2004 for <=T2c Nx/0 Mx/0 prostate cancer were evaluated. All patients were treated with I-125 seeds (prescription dose 144 Gy). Eighty-five patients with a gland volume >=50cc received 6 months of antiandrogen therapy before treatment. Patients were classified into risk groups with 232 defined as low-, 369 intermediate-, and 320 high-risk disease. The median follow-up was 69 months (range, 4-186 months); mean age was 67 years. Results: Average 5- and 10-year biochemical no evidence of disease (bNED) rates were 79% and 57%. Average 10-year bNED rates by risk group were 88% for low-risk, 61% for intermediate-risk, and 30% for high-risk disease. The average 10-year overall and disease-specific survival rates were 59% and 82%. Ten-year overall and disease-specific survival rates by risk group were, respectively, 68% and 96% for low-risk, and 64% 87% for intermediate-risk, and 49% and 69% for high-risk disease. In multivariate Cox regression analysis, both risk group and treatment era were independent predictors of bNED and survival. Conclusions: These data on long-term survival continue to support the use of I-125 monotherapy for prostate cancer in low-risk patients and, in particular, demonstrate its efficacy in intermediate-risk patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seed Implant Retention Score Predicts the Risk of Prolonged Urinary Retention After Prostate Brachytherapy

Purpose: To risk-stratify patients for urinary retention after prostate brachytherapy according to a novel seed implant retention score (SIRS). Patients and Methods: A total of 835 patients underwent transperineal prostate seed implant from March 1993 to January 2007; 197 patients had {sup 125}I and 638 patients had {sup 103}Pd brachytherapy. Four hundred ninety-four patients had supplemental external-beam radiation. The final downsized prostate volume was used for the 424 patients who had neoadjuvant hormone therapy. Retention was defined as reinsertion of a Foley catheter after the implant. Results: Retention developed in 7.4% of patients, with an average duration of 6.7 weeks. On univariate analysis, implant without supplemental external-beam radiation (10% vs. 5.6%; p = 0.02), neoadjuvant hormone therapy (9.4% vs. 5.4%; p = 0.02), baseline alpha-blocker use (12.5% vs. 6.3%; p = 0.008), and increased prostate volume (13.4% vs. 6.9% vs. 2.9%, >45 cm{sup 3}, 25-45 cm{sup 3}, <25 cm{sup 3}; p = 0.0008) were significantly correlated with increased rates of retention. On multivariate analysis, implant without supplemental external-beam radiation, neoadjuvant hormone therapy, baseline alpha-blocker use, and increased prostate volume were correlated with retention. A novel SIRS was modeled as the combined score of these factors, ranging from 0 to 5. There was a significant correlation between the SIRS and retention (p < 0.0001). The rates of retention were 0, 4%, 5.6%, 9%, 20.9%, and 36.4% for SIRS of 0 to 5, respectively. Conclusions: The SIRS may identify patients who are at high risk for prolonged retention after prostate brachytherapy. A prospective validation study of the SIRS is planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Dosimetry With a Linear MOSFET Array to Evaluate the Urethra Dose During Permanent Implant Brachytherapy Using Iodine-125

Purpose: To develop a technique to monitor the dose rate in the urethra during permanent implant brachytherapy using a linear MOSFET array, with sufficient accuracy and without significantly extending the implantation time. Methods and Materials: Phantom measurements were performed to determine the optimal conditions for clinical measurements. In vivo measurements were performed in 5 patients during the {sup 125}I brachytherapy implant procedure. To evaluate if the urethra dose obtained in the operating room with the ultrasound transducer in the rectum and the patient in treatment position is a reference for the total accumulated dose; additional measurements were performed after the implantation procedure, in the recovery room. Results: In vivo measurements during and after the implantation procedure agree very well, illustrating that the ultrasound transducer in the rectum and patient positioning do not influence the measured dose in the urethra. In vivo dose values obtained during the implantation are therefore representative for the total accumulated dose in the urethra. In 5 patients, the dose rates during and after the implantation were below the maximum dose rate of the urethra, using the planned seed distribution. Conclusion: In vivo dosimetry during the implantation, using a MOSFET array, is a feasible technique to evaluate the dose in the urethra during the implantation of {sup 125}I seeds for prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Escalation to the Dominant Intraprostatic Lesion Defined by Sextant Biopsy in a Permanent Prostate I-125 Implant: A Prospective Comparative Toxicity Analysis

Purpose: Using real-time intraoperative inverse-planned permanent seed prostate implant (RTIOP/PSI), multiple core biopsy maps, and three-dimensional ultrasound guidance, we planned a boost volume (BV) within the prostate to which hyperdosage was delivered selectively. The aim of this study was to investigate the potential negative effects of such a procedure. Methods and Materials: Patients treated with RTIOP/PSI for localized prostate cancer with topographic biopsy results received an intraprostatic boost (boost group [BG]). They were compared with patients treated with a standard plan (reference group [RG]). Plans were generated using a simulated annealing inverse planning algorithm. Prospectively recorded urinary, rectal, and sexual toxicities and dosimetric parameters were compared between groups. Results: The study included 120 patients treated with boost technique who were compared with 70 patients treated with a standard plan. Boost technique did not significantly change the number of seeds (55.1/RG vs. 53.6/BG). The intraoperative prostate V150 was slightly higher in BG (75.2/RG vs. 77.2/BG, p = 0.039). Urethra V100, urethra D90, and rectal D50 were significantly lower in the BG. No significant differences were seen in acute or late urinary, rectal, or sexual toxicities. Conclusions: Because there were no differences between the groups in acute and late toxicities, we believe that BV can be planned and delivered to the dominant intraprostatic lesion without increasing toxicity. It is too soon to say whether a boost technique will ultimately increase local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase III Randomized Trial of the Timing of Meloxicam With Iodine-125 Prostate Brachytherapy

Purpose: Nonsteroidal anti-inflammatory medication is used to reduce prostate edema and urinary symptoms following prostate brachytherapy. We hypothesized that a cyclooxygenase-2 (COX-2) inhibitor regimen started 1 week prior to seed implant might diminish the inflammatory response, thus reducing edema, retention rates, and symptom severity. Methods and Materials: From March 2004 to February 2008, 316 men consented to an institutional review board-approved randomized study of a 4-week course of meloxicam, 7.5 mg orally twice per day, starting either on the day of implant or 1 week prior to implant. Brachytherapy was performed using iodine-125 seeds and was preplanned and performed under transrectal ultrasound (TRUS) and fluoroscopic guidance. Prostate volume obtained by MR imaging at 1 month was compared to baseline prostate volume obtained by TRUS planimetry and expressed as an edema factor. The trial endpoints were prostate edema at 1 month, International Prostate Symptom Score (IPSS) questionnaire results at 1 and 3 months, and any need for catheterization. Results: Results for 300 men were analyzed. Median age was 61 (range, 45-79 years), and median TRUS prostate volume was 35.7 cc (range, 18.1-69.5 cc). Median IPSS at baseline was 5 (range, 0-24) and was 15 at 1 month, 16 at 3 months, and 10 at 6 months. Catheterization was required for 7% of patients (6.2% day 0 arm vs. 7.9% day -7 arm; p = 0.65). The median edema factor at 1 month was 1.02 (range, 0.73-1.7). 1.01 day 0 arm vs. 1.05 day -7 arm. Baseline prostate volume remained the primary predictor of postimplant urinary retention. Conclusions: Starting meloxicam 1 week prior to brachytherapy compared to starting immediately after the procedure did not reduce 1-month edema, improve IPSSs at 1 or 3 months, or reduce the need for catheterization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal Dose and Source Strength of the High-Dose-Rate Iridium-192 Both Affect Late Rectal Bleeding After Intracavitary Radiation Therapy for Uterine Cervical Carcinoma

Purpose: The purpose of this study was to reconfirm our previous findings that the rectal dose and source strength both affect late rectal bleeding after high-dose-rate intracavitary brachytherapy (HDR-ICBT), by using a rectal dose calculated in accordance with the definitions of the International Commission on Radiation Units and Measurements Report 38 (ICRU{sub RP}) or of dose-volume histogram (DVH) parameters by the Groupe Europeen de Curietherapie of the European Society for Therapeutic Radiology and Oncology. Methods and Materials: Sixty-two patients who underwent HDR-ICBT and were followed up for 1 year or more were studied. The rectal dose for ICBT was calculated by using the ICRP{sub RP} based on orthogonal radiographs or the DVH parameters based on computed tomography (CT). The total dose was calculated as the biologically equivalent dose expressed in 2-Gy fractions (EQD{sub 2}). The relationship between averaged source strength or the EQD{sub 2} and late rectal bleeding was then analyzed. Results: When patients were divided into four groups according to rectal EQD{sub 2} ({>=} or <median dose) and source strength ({>=} or <2.4 cGy.m{sup 2}.h{sup -1}), the group with both a high EQD{sub 2} and a high source strength showed a significantly greater probability of rectal bleeding for ICRU{sub RP}, D{sub 2cc}, and D{sub 1cc}. The patients with a median rectal dose above the threshold level did not show a greater frequency of rectal bleeding unless the source strength exceeded 2.4 cGy.m{sup 2}.h{sup -1}. Conclusions: Our results obtained with data based on ICRU{sub RP} and CT-based DVH parameters indicate that rectal dose and source strength both affect rectal bleeding after HDR-ICBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological in situ Dose Painting for Image-Guided Radiation Therapy Using Drug-Loaded Implantable Devices

Purpose: Implantable devices routinely used for increasing spatial accuracy in modern image-guided radiation treatments (IGRT), such as fiducials or brachytherapy spacers, encompass the potential for in situ release of biologically active drugs, providing an opportunity to enhance the therapeutic ratio. We model this new approach for two types of treatment. Methods and Materials: Radiopaque fiducials used in IGRT, or prostate brachytherapy spacers ('eluters'), were assumed to be loaded with radiosensitizer for in situ drug slow release. An analytic function describing the concentration of radiosensitizer versus distance from eluters, depending on diffusion-elimination properties of the drug in tissue, was developed. Tumor coverage by the drug was modeled for tumors typical of lung stereotactic body radiation therapy treatments for various eluter dimensions and drug properties. Six prostate {sup 125}I brachytherapy cases were analyzed by assuming implantation of drug-loaded spacers. Radiosensitizer-induced subvolume boost was simulated from which biologically effective doses for typical radiosensitizers were calculated in one example. Results: Drug distributions from three-dimensional arrangements of drug eluters versus eluter size and drug properties were tabulated. Four radiosensitizer-loaded fiducials provide adequate radiosensitization for {approx}4-cm-diameter lung tumors, thus potentially boosting biologically equivalent doses in centrally located stereotactic body treated lesions. Similarly, multiple drug-loaded spacers provide prostate brachytherapy with flexible shaping of 'biologically equivalent doses' to fit requirements difficult to meet by using radiation alone, e.g., boosting a high-risk region juxtaposed to the urethra while respecting normal tissue tolerance of both the urethra and the rectum. Conclusions: Drug loading of implantable devices routinely used in IGRT provides new opportunities for therapy modulation via biological in situ dose painting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Defined Treatment Margins in Iodine-125 Prostate Brachytherapy

Purpose: Low-dose-rate prostate brachytherapy achieves a very high and effective intraprostatic dose. Implant quality parameters concentrate on the dose received by the prostate (D90, V100) but not that received by the periprostatic tissue. We calculated implant quality parameters, D90 and V100, for the magnetic resonance imaging (MRI)-defined prostate plus 2, 3, and 5 mm. Methods and Materials: A total of 131 men with early-stage prostate cancer treated with iodine-125 brachytherapy represent all those treated with brachytherapy monotherapy in our institution in 2005. Postplan assessment was performed at 1 month using magnetic resonance (MR)-computed tomography (CT) fusion. The prostate V100 and D90 were calculated with 2-, 3-, and 5-mm margins. Results were compared with those in 8 patients with biopsy-proven local failure occurring in an experience of more than 1,100 implants. Results: Mean prostate V100 (SD) and D90 (SD) were 95.6% (4.1) and 117.2% (12.7). For prostate plus a 2-mm margin the D90 was 107.9% (14.3) and for a 3-mm margin 96.0 % (14.0). For prostate plus a 5-mm margin, the D90 was only 78.4% (11.0). The 8 patients experiencing local failure, despite adequate implants, had a lower mean V100 of 91.2% (SD, 2.8; p = 0.0008) and D90 of 103.7% (SD, 8.3; p = 0.002) and significantly inferior margin coverage. Conclusions: Satisfactory coverage of a 2-mm and 3-mm periprostatic margin is obtained with the described planning approach. Coverage falls off significantly by 5 mm. The 8 patients who experienced local failure had significantly lower doses than the margin cohort. Although the V100 and D90 would be considered acceptable, the fall-off in margin coverage was observed by 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Outcome and Toxicity of Salvage Brachytherapy for Local Failure After Initial Radiotherapy for Prostate Cancer

Purpose: To describe long-term outcomes and toxicity after salvage brachytherapy (BT) for local failure after initial radiotherapy for prostate cancer. Methods and Materials: Between 1994 and 2008, 37 men with local failure after initial prostate radiotherapy (32 external-beam radiation therapy [EBRT] and 5 BT) underwent salvage BT with {sup 103}Pd or {sup 125}I. Estimates of freedom from biochemical failure (FFbF, Phoenix definition) and cause-specific survival (CSS) were calculated using the Kaplan-Meier method. Toxicities were graded using CTCv3.0. Results: Median follow-up was 86 months (range, 2-156). The median dose to 90% of the prostate volume was 122 Gy (range, 67-166). The 10-year FFbF and CSS were 54% and 96%, respectively. On univariate analysis, prostate-specific antigen (PSA) >10 ng/mL at initial diagnosis was significantly associated with FFbF (p = 0.01), and there were trends for both age <70 years (p = 0.08) and PSA <6 ng/mL (p = 0.08) at the time of salvage BT. On multivariate analysis, only presalvage PSA <6 ng/mL (p = 0.046) was significantly associated with improved FFbF. There were three Grade 3 toxicities and one Grade 4 toxicity. Pelvic lymph node dissection before salvage BT was the only variable significantly associated with Grade {>=}2 toxicity (p = 0.03). Conclusion: With a median follow-up of 86 months, salvage prostate BT was associated with a 10-year FFbF of 54% and CSS of 96%. Improved FFbF was associated with a presalvage PSA <6 ng/mL. Toxicity was worse in patients who had undergone pelvic lymph node dissection before salvage BT. Careful patient selection for salvage BT may result in improved outcomes and reduced toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Acute Urinary Retention After Iodine-125 Prostate Brachytherapy on Health-Related Quality of Life

Purpose: To evaluate the impact of acute urinary retention (AUR) in patients treated with {sup 125}I prostate brachytherapy on short- and long-term health-related quality of life (HRQOL); and to assess whether pretreatment HRQOL has additional value in the prediction of AUR. Methods and Materials: For 127 patients treated with {sup 125}I brachytherapy for localized prostate cancer between December 2000 and June 2003, toxicity and HRQOL data were prospectively collected. Patients received a HRQOL questionnaire at five time points: before and 1 month, 6 months, 1 year, and 6 years after treatment. The questionnaire included the RAND-36 generic health survey, the cancer-specific European Organization for Research and Treatment of Cancer core questionnaire (EORTC QLQ-C30), the tumor-specific EORTC prostate cancer module (EORTC QLQ-PR25), and the American Urological Association (AUA) symptom index. Results: Of 127 patients, 13 (10.2%) developed AUR. Patients with AUR had a significantly worse urinary QOL at all time points compared with patients without AUR. The mean difference over time (6 years) between both groups for the EORTC QLQ-PR25 urinary symptom score was 13.0 points (p < 0.001) and for the AUA urinary symptom score was 15.7 points (p = 0.001). Global QOL scores (EORTC QLQ-C30) over time for patients who developed AUR were significantly worse compared with patients without AUR (mean difference 6.7 points; p = 0.043). In multivariate logistic regression analysis, pretreatment International Prostate Symptom Score (p = 0.004) and neoadjuvant hormonal treatment (p = 0.034) were predictors of AUR. Quality of life did not have added predictive value. Conclusion: Acute urinary retention after prostate brachytherapy has a significant negative impact on patient's HRQOL up to 6 years after treatment, in terms of both global QOL measures and urinary symptom scores. Furthermore, our results suggest limited value of pretreatment HRQOL measures for the prediction of AUR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biochemical Disease-Free Rate and Toxicity for Men Treated With Iodine-125 Prostate Brachytherapy With D{sub 90} {>=}180 Gy

Purpose: Iodine-125 ({sup 125}I) prostate brachytherapy is planned with a prescribed dose of 145 Gy and minimal dose received by 90% of the prostate (D{sub 90}) of 120-125% (174-181 Gy). We examined the clinical outcomes and toxicity profile of men receiving a D{sub 90} (isodose enclosing 90% of the prostate) of {>=}180 Gy. Methods and Materials: Between March 1999 and May 2006, 129 men (17% of our total brachytherapy population) treated with {sup 125}I monotherapy for Stage T1-T2 prostate cancer received a D{sub 90} {>=}180 Gy. Implants were performed using transrectal ultrasonography and fluoroscopic guidance. The 1-month postplan dosimetry used magnetic resonance imaging-computed tomography fusion. The minimal follow-up was 2 years. Toxicity was scored according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 3. Results: The median patient age was 63 years (range, 50-76), and the pretreatment prostate-specific antigen level was 5.5 ng/mL (range, 0.6-13.5). The Gleason score was {<=}6 in 125 patients and was 7 in 4 patients. The median follow-up period was 40 months (range, 24-111), and the median D{sub 90} was 186 Gy. The median minimal dose received by 30% of the urethra was 203 Gy, and the median rectal volume receiving a minimum of 100% of the prescribed dose was 0.81 cm{sup 3}. Acute Grade 2 genitourinary toxicity was seen in 5.4% and late Grade 2 in 7%. Late urinary retention (Grade 3) was seen in 2 patients (1.5%). Grade 1 rectal bleeding occurred in 9.3% and Grade 2 in 2.3%. On univariate logistic regression analysis, none of the clinical and dosimetric parameters predicted for rectal bleeding. Of 110 men who were potent before treatment, 81% remained potent 5 years after treatment. Three biochemical failures and only one local failure developed. The 5-year biochemical no evidence of disease rate using the 'nadir plus 2' definition was 96.8%. Conclusion: A D{sub 90} of {>=}180 Gy is associated with excellent biochemical disease-free survival and acceptable toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Phoenix Definition of Biochemical Failure After {sup 125}I Prostate Brachytherapy: Can PSA Kinetics Distinguish PSA Failures From PSA Bounces?

Purpose: To evaluate the prostate-specific antigen (PSA) kinetics of PSA failure (PSAf) and PSA bounce (PSAb) after permanent {sup 125}I prostate brachytherapy (PB). Methods and Materials: The study included 1,006 consecutive low and 'low tier' intermediate-risk patients treated with {sup 125}I PB, with a potential minimum follow-up of 4 years. Patients who met the Phoenix definition of biochemical failure (nadir + 2 ng/mL{sup -1}) were identified. If the PSA subsequently fell to {<=}0.5 ng/mL{sup -1}without intervention, this was considered a PSAb. All others were scored as true PSAf. Patient, tumor and dosimetric characteristics were compared between groups using the chi-square test and analysis of variance to evaluate factors associated with PSAf or PSAb. Results: Median follow-up was 54 months. Of the 1,006 men, 57 patients triggered the Phoenix definition of PSA failure, 32 (56%) were true PSAf, and 25 PSAb (44%). The median time to trigger nadir + 2 was 20.6 months (range, 6-36) vs. 49 mo (range, 12-83) for PSAb vs. PSAf groups (p < 0.001). The PSAb patients were significantly younger (p < 0.0001), had shorter time to reach the nadir (median 6 vs. 11.5 months, p = 0.001) and had a shorter PSA doubling time (p = 0.05). Men younger than age 70 who trigger nadir +2 PSA failure within 38 months of implant have an 80% likelihood of having PSAb and 20% chance of PSAf. Conclusions: With adequate follow-up, 44% of PSA failures by the Phoenix definition in our cohort were found to be benign PSA bounces. Our study reinforces the need for adequate follow-up when reporting PB PSA outcomes, to ensure accurate estimates of treatment efficacy and to avoid unnecessary secondary interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison Between High and Low Source Activity Seeds for I-125 Permanent Seed Prostate Brachytherapy

Purpose: To compare low (mean 0.44, SD {+-} 0.0163 mCi) with high source activity (0.61 {+-} 0.0178 mCi) in I{sup 125} permanent seed brachytherapy regarding seed loss, dosimetric outcome, and toxicity. Methods and Materials: The study included 199 patients with prostate cancer treated by permanent seed brachytherapy alone: the first 105 with seeds of lower activity (first cohort), the following 94 with higher seed activity (second cohort). The V100, V150, V200, and D90 were analyzed on the CT scan 30 days after implantation (CTD30). The V100, V150, and D2 of the rectum were also calculated on CTD30. Seed loss was determined 30 days after implantation. Urinary toxicity was measured with the International Prostate Symptom Score (IPSS) questionnaire. Results: Lower seed activity was associated with lower V150 and V200 (p = 0.01 and p {<=} 0.001, respectively) on CTD30. More patients had a V100 <90% and D90 <140 Gy in the lower activity cohort (p = 0.098 for D90 and p = 0.029 for V100) on CTD30. There was no difference between cohorts in dose to the rectum (p = 0.325-0.516) or difference in patients' IPSS score from baseline (p = 0.0.117-0.618), although there was a trend toward more urinary toxicity at 4 and 8 months for high activity seeds. Seed loss as a percentage of implanted seeds was not different (p = 0.324). Conclusions: Higher seed activity (I{sup 125} {>=} 0.6 mCi) results in at least equal V100 and D90 on CTD30. However, dose inhomogeneity and a trend toward more urinary toxicity at 4 and 8 months after treatment may lead to a higher long-term urinary complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternative Dose for Choroidal Melanoma Treated With an Iodine-125 Radioactive Plaque: A Single-Institution Retrospective Study

Purpose: The Collaborative Ocular Melanoma Study (COMS) established iodine-125 plaque brachytherapy as an accepted standard treatment for medium-size choroidal melanoma. In the COMS, the prescription dose was 85 Gy. This is a retrospective review of our outcomes in patients treated with lower doses than those used in the COMS. Methods and Materials: From 1990 to 2004, 62 patients were treated with iodine-125 plaque brachytherapy for choroidal melanoma. COMS eye plaques were used with dose prescribed to the apex of the tumor. The median and average dose rates at the tumor apex were 63.5 cGy/h and 62.7 cGy/h, respectively. The median and average total doses were 63.0 Gy and 62.5 Gy (range, 56-69 Gy), respectively. The median and mean durations of implant were 100.0 hours and 101.1 hours (range, 71-165 hours). Results: Median follow-up time was 58.2 months. The 5-year outcomes including overall survival, disease-free survival, cause-specific survival, local failure, secondary enucleation rate, and visual acuity (VA) <20/200 were estimated using the Kaplan-Meier method. Overall, there were 7 local failures, 4 distant failures, and 10 secondary enucleations (6 due to local failure and 4 due to treatment complications). Univariate analysis was performed to identify significant prognostic factors associated with disease-free survival (baseline VA in tumor eye, tumor shape), cause-specific survival (diabetic retinopathy), local failure (none found), secondary enucleation rate (diabetic retinopathy, basal tumor dimension) and VA <20/200 (diabetic retinopathy, tumor shape, age, retinal detachment, treatment depth, and history of vision-limiting condition). Conclusions: Our survival and local control outcomes are comparable to those of the COMS. However, VA at 5 years seems to be better. Lower doses of radiation could potentially lead to better visual outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗