Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bead–Spring Simulation of Ionomer Melts—Studying the Effects of Chain-Length and Associating Group Fraction on Equilibrium Structure and Extensional Flow Behavior

Ionomers are associative polymers with diverse applications ranging from selective membranes and high-performance adhesives to abrasion- and chemical-resistant coatings, insulation layers, vacuum packaging, and foamed sheets. Within equilibrium melt, the ionic or associating groups are known to form thermally reversible, associative clusters whose presence can significantly affect the system’s mechanical, viscoelastic, and transport properties. It is, thus, of great interest to understand how to control such clusters’ size distribution, shape, and stability through the designed choice of polymer architecture and the ionic groups’ fraction, arrangement, and interaction strength. In this work, we represent linear associating polymers using a Kremer–Grest type bead–spring model and perform large-scale MD simulations to explore the effect of polymer chain-length (l) and fraction (f s ) of randomly placed associating groups on the size distribution and stability of formed clusters. We consider different chain-lengths (below and above entanglement), varying fractions of associating groups (represented by ‘sticky’ beads) between 5 and 20%, and a fixed sticky–sticky nonbond interaction strength of four times that between regular non-associating beads. For all melts containing associating groups the equilibrium structure factor S(q) displays a signature ionomer peak at low wave vector q whose intensity increases with increasing f s and l. The average cluster size Nc increases with f s . However, the effect of chain-length on Nc appears to be pronounced only at higher values of f s . Under extensional flows, the computed stress (and viscosity) is higher at higher f s and l regardless of strain rate. Beyond a critical strain rate, we observe fragmentation of the associative clusters, which has interesting effects on the stress/viscous response.

36 MATERIALS SCIENCE↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transport from electron-scale turbulence in toroidal magnetic confinement devices

Plasma transport driven by turbulence ultimately determines the energy confinement performance of controlled fusion devices regardless of their confinement schemes and configurations. A large variety of plasma instabilities have been proposed for driving turbulence responsible for anomalous plasma transport beyond classical/neoclassical transport due to collisions. Although ion-scale turbulence usually dominates due to its large eddy size and saturation level, electron-scale turbulence has been recognized to be important in regions where ion-scale turbulence is suppressed (e.g., in internal transport barrier and in spherical tokamak H-mode plasmas) or is close to marginality. Electron-scale turbulence has been shown to nonlinearly interact with ion-scale turbulence, which modifies the dynamics of both and affects the resulting plasma transport, particularly when ion-scale instability is weakly driven. In this review paper, we focus on electron-scale turbulence that is believed to operate in magnetically confinement fusion devices and aim to provide a review of theoretical, numerical, and experimental developments in understanding electron-scale turbulence and its role in driving anomalous plasma turbulence. In particular, we focus on the electrostatic electron temperature gradient (ETG) mode which is the most widely recognized plasma instability underlying electron-scale turbulence observed in magnetically confined plasmas. Finally, we note that there are other less studied instabilities that might be responsible for observed electron-scale turbulence, most notably ubiquitous mode, and short-wavelength ion temperature gradient (SWITG) mode, which will be briefly touched on in this review.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Robust Carbon Dioxide Plume Imaging Using Joint Tomographic Inversion of Seismic Onset Time and Distributed Pressure and Temperature Measurements (Final Report)

We develop and demonstrate rapid and cost-effective methodologies for spatiotemporal tracking of CO2 plumes during geologic sequestration using joint inversion of seismic data and distributed pressure and temperature measurements. Key elements of our methodology are: (a) a computationally efficient approach to pressure and temperature propagation, (b) analysis of time lapse seismic data using a novel ‘seismic onset time’ approach to detect fluid front propagation, and (c) data assimilation and uncertainty assessment via joint inversion of pressure, temperature and time lapse seismic data, and (d) validating the numerical tomographic inversion using a CO2 injection demonstration projects, specifically data collected from the from the Petra Nova Parish Holdings CCUS project in the West Ranch Field, Texas and the Chester-16 reef CO2 injection site in Northern Michigan which is part of the DOE Midwestern Carbon Sequestration Project. The research team is led by Texas A&M University and includes Battelle as a subcontractor with support from Shell, Anadarko, Chevron and JX Nippon. A carbon dioxide (CO2) water-alternating-gas (WAG) pilot was conducted to gain insights into tertiary oil recovery potential via CO2 flood in the West Ranch Field as part of the Petra Nova project, the world’s largest post-combustion CO2 capture and utilization initiative. With a fluvial formation geology and large contrasts in permeability, this is a challenging and novel application of CO2 enhanced oil recovery (EOR). We build a predictive dynamic model of the subsurface that incorporates the multiphase and compositional data acquired during the pilot operation. The calibrated model is used for the carbon dioxide plume imaging. The study began with an initialization of the pilot sector model extracted from a calibrated full-field model. The pilot model calibration follows a two-step hierarchical workflow. First, we performed a large-scale update of the permeability distribution by integrating available bottomhole pressure and multiphase production data. In the second step, local permeability field is fine-tuned using a streamline-based method to match CO2 breakthrough times at the producers. The predictive capability of the calibrated model was verified through two blind validation tests: (1) the model showed good agreement with saturation logs acquired at two observation wells; and (2) the model reproduced the CO2 recovery as a fraction of the injected CO2. The use of seismic onset times has shown great promise for integrating near-continuous seismic surveys for updating geologic models. In this study, we analyze the impact of seismic survey frequency on the onset time approach aiming to extend the application of onset time to infrequent seismic surveys. In addition, we quantitatively examine the nonlinearity of the onset time method and compare it to the commonly used amplitude inversion method. We carry out a sensitivity analysis of seismic survey frequency based on the complete seismic survey data (over 175 surveys) of steam injection in a heavy oil reservoir (Peace River Unit) in Canada. Our results show that an adequate onset time map can be obtained from the infrequent seismic surveys by interpolation between seismic surveys as long as there is no change in the dominant underlying physics between the successive surveys. The study also shows that nonlinearity of the onset time method can be -smaller than that of the amplitude inversion method by several orders of magnitude. Application to the Brugge benchmark case shows that the onset time method obtains comparable permeability update as the traditional seismic amplitude inversion method with faster computation and improved convergence characteristics. We extend the streamline-based data integration approach to incorporate distributed temperature sensor (DTS) data using the concept of thermal tracer travel time. Then, a hierarchical workflow composed of evolutionary and streamline methods is employed to jointly history match the DTS and pressure data. Finally, CO2 saturation and streamline maps are used to visualize the CO2 plume movement during the sequestration process. The hierarchical workflow is applied to a carbon sequestration project in a carbonate reef reservoir within the Northern Niagaran Pinnacle Reef Trend in Michigan, USA. The monitoring data set consists of distributed temperature sensing (DTS) data acquired at the injection well and a monitoring well, flowing bottom-hole pressure data at the injection well, and time-lapse pressure measurements at several locations along the monitoring well. The history matching results indicate that the CO2 movement is mostly restricted to the intended zones of injection which is consistent with an independent warm-back analysis of the temperature data. In addition to employing simulation models and inverse methods for CO2 plume imaging, we also initialized a data-driven technology for detecting inter-well connectivity based on production and pressure data. Our machine-learning framework is built on the statistical recurrent unit (SRU) model and interprets well-based injection/production data into inter-well connectivity without relying on a geologic model. We test it on synthetic and field-scale CO2 EOR projects utilizing the water-alternating-gas (WAG) process. The validation of the proposed data-driven inter-well connectivity assessment is performed using synthetic data from simulation models where inter-well connectivity can be easily measured using the streamline-based flux allocation. The SRU model is shown to offer excellent prediction performance on the synthetic case. Despite significant measurement noise and frequent well shut-ins imposed in the field-scale case, the SRU model offers good prediction accuracy, the overall relative error of the phase production rates at most producers ranges from 10% to 30%. It is shown that the dominant connections identified by the data-driven method and streamline method are in close agreement. Texas A&M University, the lead organization in the project, was primarily responsible for the development of tomographic approaches for CO2 plume mapping in conjunction with distributed pressure, temperature and seismic onset time data. Battelle, as a subcontractor, was primarily responsible for the development of analytical and empirical methods for analyzing transient injection rate and pressure data from point/line sources such as injection and monitoring wells. An additional area of emphasis for Battelle was the use of machine learning for such tasks as inferring reservoir connectivity information from injection-production data, and identifying variable importance for machine learning-based proxy models developed from full-physics simulations. The two organizations also collaborated on the application of the tomographic inversion methodology for a field data set.

02 PETROLEUM↗

Constrained non-negative matrix factorization enabling real-time insights of in situ and high-throughput experiments

Non-negative matrix factorization (NMF) is an appealing class of methods for performing unsupervised learning on streaming spectral data, particularly in time-sensitive applications such as in situ characterization of materials. These methods seek to decompose a dataset into a small number of components and weights that can compactly represent the underlying signal while effectively reconstructing the observations with minimal error. However, canonical NMF methods have no underlying requirement that the reconstruction uses components or weights that are representative of the true physical processes. In this work, we demonstrate how constraining a subset of the NMF weights or components as rigid priors, provided as known or assumed values, can provide significant improvement in revealing true underlying phenomena. We present a PyTorch-based method for efficiently applying constrained NMF and demonstrate its application to several synthetic examples. Our implementation allows an expert researcher-in-the-loop to provide and dynamically adjust the constraints during a live experiment involving streaming spectral data. Such interactive priors allow researchers to specify known or identified independent components, as well as functional expectations about the mixing or transitions between the components. We further demonstrate the application of this method to measured synchrotron x-ray total scattering data from in situ beamline experiments. In such a context, constrained NMF can result in a more interpretive and scientifically relevant decomposition than canonical NMF or other decomposition techniques. As a result, the details of the method are provided, along with general guidance for employing constrained NMF in the extraction of critical information and insights during time-sensitive experimental applications.

36 MATERIALS SCIENCE↗

Nested Pebble Bed Blanket (NesPeB)

Recent advances in magnetic confinement fusion technology have attracted billions of dollars of investments in startups from venture capitals and corporations, resulting in the development of devices aiming to demonstrate net energy gain in a self-heated burning plasma, such as SPARC (under construction) and others. However, future fusion power plants must operate in regimes that will require technologies far beyond current experience. According to a National Academies of Science, Engineering, and Medicine report, to have nuclear fusion power plants contributing in a timely manner to the planned reduction of atmospheric carbon dioxide, a pilot plant should be built by 2035, and it should demonstrate fusion power production and the performance of the tritium fuel system (requiring a high enough tritium breeding) by 2040. A recognized key technology gap by [26] is the fusion first wall and blanket since no current blanket concept is considered satisfactory or has been built and proven. The first wall and blanket in magnetic fusion reactors form a vital and complex system, as it must satisfy different functions such as power extraction, tritium breeding, plasma containment, radiation shielding, and safety. The list of design requirements is even longer: high enough tritium production for fusion self-sufficiency, low material activation, decay heat and shutdown dose rates, high thermal efficiency, high-capacity factor, high magnets-divertor-vacuum vessel-first wall life, low corrosion, low cost, and intrinsically safe (requiring minimal licensing). Despite fifty-plus years of research, the first wall and blanket concepts proposed suffer from fundamental technical problems and immaturity (TRL=2-3) that jeopardize the timely delivery of a commercial fusion power plant. A fusion first-wall blanket has never been built nor tested, and a "winning", practical functioning design requires enough engineering margins (high enough tritium breeding considering the uncertainty, etc.), manufacturing simplicity, ease of continuous operation, maintenance, and low cost. A new, groundbreaking blanket concept called "Nested Pebble Bed Blanket" (NesPeB) was developed at ORNL under the successful ARPA-E GAMOW FERMI project (patent application allowed by the USPTO). The NesPeB blanket concept addresses current blanket concepts' shortcomings and technical immaturity, paving the way for accelerated delivery of fusion power plants. NesPeB is based on nested pebbles, which are binary-sized lithium-ceramic pebbles enclosed in "Beryllide" perforated and coated spherical shells, which are also binary-sized, stacked on top of each other, forming a "bed" and cooled by Nitrogen gas also "sweeping" the Helium and Tritium generated by the neutron irradiation of Lithium; the vacuum vessel plasma facing material is Molybdenum-96 and -97 with the first wall cooled by Helium while the divertor armor is made of Tungsten. The simulations of the NesPeB blanket using Fusion Reactors Models Integrator (FERMI) are encouraging as they estimate a tritium breeding ratio (TBR) greater than 1.2 using natural Lithium, acceptable pressure drop, and excellent heat transfer properties. Furthermore, the NesPeB blanket is not limited by magneto-hydro-dynamics (MHD) effects, is designed for online refueling, relies on existing tritium extraction technologies, has a simple construction, and limits the corrosion and chemical reactivity problems. NesPeB has the potential to be transformational and disruptive since it can solve all the main, challenging technical problems of fusion device blankets and accelerate a pilot plant delivery for 10 or more years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron transfer calculations between edge sharing octahedra in hematite, goethite, and annite

A key reaction underlying the charge transport in iron containing oxides, clays, micas is the Fe$^{2+}$-Fe$^{3+}$ exchange reaction between edge-sharing iron octahedra. These reactions facilitate conduction in these minerals by the thermally-activated hopping of small polarons across the lattice. Depending on the mineral and local charge state the small polaron can either encase an electron or hole. The probability for conduction of small polarons depends strongly on the height and adiabicity of the reaction barrier, with larger and more diabatic barriers yielding slow conduction associated with either weak coupling or a large prerequisite rearrangement of the lattice during charge transport. To model these reactions, a first principle electron transfer (ET) method was developed to model the small polaron hopping between the edge-sharing octahedra sites in hematite ($e^{-}$ polaron), goethite ($e^{-}$ polaron), and annite ($h^{+}$ polaron) bulk structures. The ET method is based on electronic structure methods (i.e., plane-wave Density Functional Theory) capable of performing calculations with periodic cells and large size systems efficiently while at the same time being accurate enough to be used in the estimation of the electron-transfer coupling matrix element, $V_{AB}$, and the electron transfer transmission factor, $\kappa_{el}$. Additionally, the calculations confirmed the existence of small polarons in all three minerals, and the reactions were predicted to be strongly adiabatic. It was found that transfer of a hole in the octahedral layer of annite had an adiabatic barrier of $0.311$ eV, and the transfer of an extra electron in hematite and goethite had adiabatic barriers of $0.242$ eV and $0.232$ eV respectively. The electronic coupling parameters,$V_{AB}$, were found to be $0.188$ eV, $0.196$ eV, and $0.102$ eV respectively for hematite, goethite, and annite. While similar bonding topologies pertain, the underlying basis for the differences is the subtle differences in local structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Signature Analysis Utilizing a Dynamic Molten Salt Reactor Model for MC&A

Moving from traditional fixed fuel nuclear reactor systems to a mobile, dynamic fuel system that has dissolved special nuclear material in a molten salt is a paradigm shift in several respects. One major consideration is how to develop effective nuclear material controls and accounting for these novel reactor systems. The Molten Salt Reactor Experiment is one example of a critical molten salt system and provided a significant reference library based on the documented effort. But it was low thermal power that was not intended to reflect a commercial scale electricity production design. Therefore, to facilitate and assist vendors with domestic licensing considerations, research is underway to identify methods that could be used for domestic safeguards approaches for these novel reactor systems. This research presents the results of a signature analysis of data generated from three simulated scenarios using the molten salt demonstration reactor model defined in the Transient Simulation Framework of Reconfigurable Modules. Each scenario provides 1 hour isotope inventories over a 180 day period. The scenarios investigated provide test cases to examine if direct gamma-ray spectroscopy of the fuel can be used to identify changes comparing a base case (no reactivity control and fixed fission contribution) to an insertion of reactivity (10 pcm no change in fission composition) and a change in fission composition. The analysis demonstrates that monitoring the total count rate in a highly collimated high-resolution photon energy spectrum is sensitive to perturbations imposed into the reactor model. The total photon count rate changes ≈2% for the fission composition change and ≈4.5% for the reactivity insertion compared to the base case. However, both scenarios show an increase in the total photon count rate. The total photon count rate can be used to identify changes due to power (number of fissions) but not due to a change in the material undergoing fission. To distinguish between the two cases of increased power, the photon spectrum would require an intensive analysis technique. A photon peak count rate ratio analysis could be used to identify changes in the fissile material fission generation in the core through identification of a static peak that shows little variation to the source of fission and a highly varying peak. The photon peak strength will ultimately be determined by the isotope’s fission yield. A preliminary analysis investigating the coupling of the isotope’s fission yield and its concentration in the fuel salt derived from the modeling has been performed. A ratio analysis of the photon peak count rates of 140 La to 99 Mo demonstrated that the reactivity insertion creates a distinct difference in the ratio compared to the fission composition change scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laser Measurements and Modeling of Shock Tunnel Freestream Velocity and Multispecies Thermal Nonequilibrium

Coherent anti-Stokes Raman scattering (CARS) and nitric oxide molecular tagging velocimetry (NO-MTV) were used to characterize the freestream in Sandia’s Hypersonic Shock Tunnel (HST) using a burst-mode laser operated at 100 kHz. Experiments were performed at nominal freestream velocities of 3 and 4 km/s using both air and N 2 test gas. The CARS diagnostic provides nonequilibrium characterization of the flow by measuring vibrational and rotational temperatures of N 2 and O 2 , which are compared to NO temperatures from separate laser absorption experiments. Simultaneous, collinear freestream velocities were measured using NO MTV along with pitot pressure measurements. Furthermore, this extensive freestream dataset is compared to nonequilibrium CFD that is capable of modeling species-specific, vibrational temperatures throughout the nozzle expansion. Significant nonequilibrium between vibrational and rotational temperatures was measured at each flow condition. N 2 exhibits the most nonequilibrium, followed by O 2 and NO. The CFD model captures this trend, although it consistently overpredicts N 2 and O 2 vibrational temperatures. At 3 km/s, the modeled NO nonequilibrium is underpredicted, whereas it is overpredicted at 4 km/s. Good agreement is seen between CFD and the velocity and rotational temperature measurements. Experiments with water added to the test gas yielded no discernable difference in vibrational relaxation.

Aerodynamics↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward Verification of RANS Simulations of the T-Tube Modular Divertor Using Large Eddy Simulations of Impinging Turbulent Plane Jets

Turbulent impinging jets have been proposed to cool high heat flux plasma-facing components such as the solid tungsten target plates of the divertor in long-pulse magnetic fusion energy reactors. In particular, the T-tube modular divertor, originally developed by the ARIES Team, consists of two concentric cylindrical tubes where helium flows through a slot in the inner tube, forming an approximately planar jet that impinges upon and cools the inner surface of the pressure boundary (namely, the outer tube) and the ~15-cm 2 plasma-facing W target. The objective of this work is to demonstrate that large eddy simulations (LESs) accurately simulate the thermal transport in canonical flows that comprise the cooling flow in the T-tube, as well as validate temperatures from LES with experimental measurements in a simplified T-tube geometry. Wall‑resolved LESs, validated by experimental data and verified by direct numerical simulations (DNSs), provide benchmark data for two canonical flows in the T‑tube, namely, planar impinging and wall jets, for Reynolds numbers Re B = 4 × 10 3 to 2 × 10 4 . Our LES results are within 4% to 12% root-mean-square error (RMSE) of surface Nusselt number distributions (Nu) from experiments and DNSs. The validated LES results are then used as the ground truth to evaluate four Reynolds‑averaged Navier-Stokes (RANS) turbulence closures, namely, the k‑ω SST, realizable k‑ε, GEKO, and γ‑SST models. The k‑ω SST model has the best overall performance in terms of heat transfer, giving surface Nu within 12% RMSE of the LES results for high‑ReB impinging jets and reduced overprediction in the wall‑jet region. The GEKO model with default constants has the next best performance, providing slightly better Nu predictions for low ReB impinging jets (versus k-ω SST) but worse overall performance over the full range of ReB studied here. The realizable k‑ε turbulence model significantly overestimates turbulence near the stagnation point, while the γ‑SST model suppresses near‑wall production, biasing the simulations toward simulating laminar surface heat transfer. Simulations of the simplified T‑tube show that LES and RANS simulations with the k‑ω SST model give nearly identical average heat transfer coefficients (HTCs) over the impingement surface. The realizable k‑ε model predicts significantly lower wall temperatures due to overestimation of HTC in the outlet flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of high-order Godunov-type methods in simulations of astrophysical low Mach number flows

High-order Godunov methods for gas dynamics have become a standard tool for simulating different classes of astrophysical flows. Their accuracy is mostly determined by the spatial interpolant used to reconstruct the pair of Riemann states at cell interfaces and by the Riemann solver that computes the interface fluxes. In most Godunov-type methods, these two steps can be treated independently, so that many different schemes can in principle be built from the same numerical framework. Because astrophysical simulations often test out the limits of what is feasible with the computational resources available, it is essential to find the scheme that produces the numerical solution with the desired accuracy at the lowest computational cost. However, establishing the best combination of numerical options in a Godunov-type method to be used for simulating a complex hydrodynamic problem is a nontrivial task. In fact, formally more accurate schemes do not always outperform simpler and more diffusive methods, especially if sharp gradients are present in the flow. For this work, we used our fully compressible Seven-League Hydro (SLH) code to test the accuracy of six reconstruction methods and three approximate Riemann solvers on two- and three-dimensional (2D and 3D) problems involving subsonic flows only. We considered Mach numbers in the range from 10 −3 to 10 −1 , which are characteristic of many stellar and geophysical flows. In particular, we considered a well-posed, 2D, Kelvin–Helmholtz instability problem and a 3D turbulent convection zone that excites internal gravity waves in an overlying stable layer. Although the different combinations of numerical methods converge to the same solution with increasing grid resolution for most of the quantities analyzed here, we find that (i) there is a spread of almost four orders of magnitude in computational cost per fixed accuracy between the methods tested in this study, with the most performant method being a combination of a low-dissipation Riemann solver and a sextic reconstruction scheme; (ii) the low-dissipation solver always outperforms conventional Riemann solvers on a fixed grid when the reconstruction scheme is kept the same; (iii) in simulations of turbulent flows, increasing the order of spatial reconstruction reduces the characteristic dissipation length scale achieved on a given grid even if the overall scheme is only second order accurate; (iv) reconstruction methods based on slope-limiting techniques tend to generate artificial, high-frequency acoustic waves during the evolution of the flow; and (v) unlimited reconstruction methods introduce oscillations in the thermal stratification near the convective boundary, where the entropy gradient is steep.

79 ASTRONOMY AND ASTROPHYSICS↗

DASSH-F: Subchannel Based Thermal Analysis

The DASSH thermal analysis code is designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. The advantage of using DASSH over a hand calculation is that it has a more rigorous treatment of the pin power distribution and coolant heat transfer within an assembly and between assemblies. The advantage of using DASSH over a conventional 3D subchannel code or a computational fluid dynamics code (CFD) is that it can obtain the desired solution in a matter of minutes in serial with minor computer memory needs. The DASSH methodology is virtually identical to SUPERENERGY-2 with additional functionalities taken from follow on work to SUPERENERGY-2 done at ANL in the 1980s. DASSH today is an integral component of the Argonne Fast Reactor analysis suite for reactor design work. DASSH obtains the power distribution from a coupled neutron-gamma heating calculation in GAMSOR (including DIF3D) at each time point of a companion fuel cycle analysis calculation with REBUS. The domain in DASSH assumes a hexagonal grid typical for fast reactors with much of the geometry information taken from the DIF3D model. DASSH assumes the assemblies that are loaded into each grid position are ducted to control the coolant flow. Considerable detail is given on the subchannel formulation of DASSH in this document. Much of the formulation and design of the code builds upon research done by previous authors with little new investigation. Thus the decisions made in developing the subchannel model used in DASSH have their origins over 50 years ago. Much of the heat transfer methodology in DASSH is built upon correlations for both the coolant mixing and heat transfer coefficients for pins and ducts. DASSH is thus not a rigorous treatment of a given problem, but a rapid assessment of the temperature field that has known limitations with respect to an experimental measurement or CFD calculation. The DASSH input and output are detailed along with usage of the software. The DASSH output provides tables of evaluated material properties and key coolant and pin temperature results. DASSH can create Python scripts that generate domain summary pictures. DASSH can also generate assembly temperature maps and VTK output files which allow the DASSH solution to be visualized. As the primary purpose of the DASSH software is to compute the coolant and fuel pin temperature distribution for a given model of a reactor, much of the output focus is giving the user quick summary tables needed to assess the performance of a given orifice flow specification. The present version of DASSH has a crude orifice search capability and an efficient orifice flow search capability. The flow search tries to meet user specified constraints for 1) peak 2-sigma clad midwall temperature, 2) peak coolant temperature, and 3) desired bulk outlet temperature. There are many development shortcomings in DASSH detailed in this document, but this version is functional for modern analysis needs. This document serves as the manual for the Fortran based DASSH software that was developed to replace the Python version of DASSH developed as part of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Material Plasma Exposure eXperiment (MPEX) High Heat Flux Bellows for Component Alignment in High Microwave Environment

The Material Plasma Exposure eXperiment (MPEX) device is a linear plasma device developed to perform plasma material interaction experiments under the conditions prototypic of a fusion reactor divertor. MPEX has multiple systems that must be precisely aligned to the plasma axis, including an electron cyclotron heating system that emits up to 400 kW of microwave power into the vacuum vessel. Five distinct systems require precise alignment on the MPEX device, thus requiring four bellows, all of which are adjacent to the plasma at a relatively high heat flux of approximately 47 kW/m2 and microwave power regions. The MPEX high heat flux bellows (HHFB) is designed to deliver 6 degrees of freedom positioning. The HHFB includes titanium–zirconium–molybdenum (TZM) inserts that are brazed into a Glidcop AL-15 body using a high-temperature braze alloy, thus blocking direct line of sight to an edge-welded bellows from the plasma and microwave screen to block microwaves from the bellows. Further, a custom ConFlat knife edge is machined into the Glidcop AL-15, so the vacuum flanges do not need a braze or weld joint on the vacuum interface. Fingerstock or copper mesh is used to restrict microwave power from entering the interstitial space between the water-cooled Glidcop AL-15 body and edge-welded bellows. Glidcop AL-15 was selected as the material of choice for the water-cooled body because it can maintain mechanical integrity at elevated temperatures, and it also allows for a high-temperature braze. TZM was selected for its machinability and compatibility with vacuum and plasma requirements. A test article is also being considered for a similarly shaped component, the MPEX limiter, that will demonstrate the integrity of the braze joint under high thermal load. Results from this testing will be extrapolated to deduce the lifetime and integrity of the HHFB design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DASSH-F: Subchannel Based Thermal Analysis

The DASSH thermal analysis code is designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. The advantage of using DASSH over a hand calculation is that it has a more rigorous treatment of the pin power distribution and coolant heat transfer within an assembly and between assemblies. The advantage of using DASSH over a conventional 3D subchannel code or a computational fluid dynamics code (CFD) is that it can obtain the desired solution in a matter of minutes in serial with minor computer memory needs. The DASSH methodology for pin lattice models is virtually identical to SUPERENERGY-2 with additional functionalities taken from follow on work to SUPERENERGY-2 done at ANL in the 1980s. DASSH today is an integral component of the Argonne Fast Reactor analysis suite for reactor design work. DASSH obtains the power distribution from a coupled neutron-gamma heating calculation in GAMSOR (including DIF3D) at each time point of a companion fuel cycle analysis calculation with REBUS. The domain in DASSH assumes a hexagonal grid typical for fast reactors with much of the geometry information taken from the DIF3D model. DASSH assumes the assemblies that are loaded into each grid position are ducted to control the coolant flow. The user can alternatively provide their own geometry and power profile instead of inheriting it from DIF3D. Considerable detail is given on the subchannel formulation of DASSH in this document. Much of the formulation and design of the code builds upon research done by previous authors with little new investigation. Thus the decisions made in developing the subchannel model used in DASSH have their origins over 50 years ago. Much of the heat transfer methodology in DASSH is built upon correlations for both the coolant mixing and heat transfer coefficients for pins and ducts. DASSH is thus not a rigorous treatment of a given problem, but a rapid assessment of the temperature field that has known limitations with respect to an experimental measurement or CFD calculation. The DASSH input and output are detailed along with usage of the software. The DASSH output provides tables of evaluated material properties and key coolant and pin temperature results. DASSH can create Python scripts that generate domain summary pictures. DASSH can also generate assembly temperature maps and VTK output files which allow the DASSH solution to be visualized. As the primary purpose of the DASSH software is to compute the coolant and fuel pin temperature distribution for a given model of a reactor, much of the output focus is giving the user quick summary tables needed to assess the performance of a given orifice flow specification. The present version of DASSH has a crude orifice search capability and a sufficient orifice flow search capability. The flow search tries to meet user specified constraints for 1) peak 2-sigma clad temperature, 2) peak coolant temperature, and 3) desired bulk outlet temperature. This document serves as the manual for the Fortran based DASSH software that was developed to replace the Python version of DASSH developed as part of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗