Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “differential sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Capabilities of the cosmic background explorer

The cosmic background explorer, now being redesigned for a launch on a Delta rocket in 1989, will carry three instruments to measure the cosmic infrared and microwave background radiation and other diffuse sources from 1 micron to 1 cm wavelength. These instruments will be orders of magnitude more sensitive and accurate than previous equipment and will help determine the structure of the early universe. The instruments are (1) an absolute spectrophotometer, covering 100 microns to 1 cm, (2) an absolute infrared radiometer covering 1 to 300 microns, and (3) differential microwave radiometers at 32, 53, and 90 GHz. They will measure the large scale anisotropy and the spectrum of the 3 K cosmic background, and search for the extragalactic infrared background, to a sensitivity limited by the astrophysical environment. The first two instruments require liquid helium cooling, limiting their lifetime to about 14 months.

Mather, J. C.↗

Precision probes of QCD at high energies

New physics, that is too heavy to be produced directly, can leave measurable imprints on the tails of kinematic distributions at the LHC.We use energetic QCD processes to perform novel measurements of the Standard Model (SM) Effective Field Theory. We show that the dijet invariant mass spectrum, and the inclusive jet transverse momentum spectrum, are sensitive to a dimension 6 operator that modifies the gluon propagator at high energies. The dominant effect is constructive or destructive interference with SM jet production. Here, we compare differential next-to-leading order predictions from POWHEG to public 7TeV jet data, including scale, PDF, and experimental uncertainties and their respective correlations. Furthermore, we constrain a New Physics (NP) scale of 3.5TeV with current data. We project the reach of future 13 and 100TeV measurements, which we estimate to be sensitive to NP scales of 8 and 60TeV, respectively. As an application, we apply our bounds to constrain heavy vector octet colorons that couple to the QCD current. We conclude that effective operators will surpass bump hunts, in terms of coloron mass reach, even for sequential couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new potential energy surface and state-to-state quantum dynamics of the $\mathrm{Li + HF → H + LiF}$ reaction

A new global potential energy surface (PES) for the ground ($\tilde{X}^2A'$) state of the Li + HF → LiF + H reactive system is constructed by fitting 12,399 points computed at the UCCSD(T)-F12b/aug-cc-pV5Z level of theory. The use of a neural network method helps to achieve a high-fidelity fit with a root mean square error of 0.88 meV. Quantum dynamics calculations with full Coriolis coupling on the new PES yield both differential and integral cross sections over a range of energy. In agreement with experiment, the product angular distribution depends sensitively on collision energy, but all with a forward bias. Moderate internal excitation is found in the LiF product. The energy dependence of the integral cross section is in reasonably good accord with the experimental excitation function, although some quantitative differences persist. This late-barrier reaction shows a dramatic vibrational enhancement of reactivity. The mode specificity is rationalized using the Sudden Vector Projection model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compression-Induced Crystallization in Sucrose-Polyvinylpyrrolidone Amorphous Solid Dispersions

Tablets of amorphous sucrose and sucrose-polyvinylpyrrolidone (PVP) amorphous solid dispersions were compressed at 25, 75, or 150 MPa at dwell times ranging from 5 to 900 s. Compression-induced physical destabilization was evident from differential scanning calorimetry. Crystallization kinetics was monitored using a laboratory source X-ray diffractometer, while crystallization was detected using highly sensitive synchrotron radiation. At the highest compression pressure, sucrose crystallization was evident immediately after compression. However, the addition of PVP, even at a low concentration of 1% w/w, inhibited crystallization. Furthermore, nucleation itself was completely prevented at higher PVP concentrations (≥15% w/w) under a compression pressure of practical interest (150 MPa with 5 s dwell time). However, an increase in dwell time (e.g., to 60 s) facilitated nucleation, and there was an increase in nucleation density as a function of dwell time. Both polymer content and sample history were pivotal factors limiting compression-induced crystallization in plasticized amorphous systems. Furthermore, plasticization was found to amplify compression-induced destabilization. PVP, in a concentration dependent manner, attenuated this effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutral gas analysis for JET DT operation

Neutral gas analysis, the measurement and evaluation of total and partial pressures, is a key technique to study the impact of neutral gas dynamics on retention, recycling and release processes of fuel or impurity species in fusion devices. At JET, the experiment closest to ITER in terms of operating parameters and size, various detectors and techniques for partial pressure and total pressure measurements are deployed together to characterise neutral gas dynamics during and after plasma operation on various toroidal and poloidal locations. An extensive modification of JET's sub-divertor neutral gas diagnostic system aims at retaining and extending established measurement capabilities in the forthcoming Deuterium-Tritium (DT) experiments (DTE2). To achieve DT compatibility, a separation of radiation-sensitive electronics from the sensor and adequate radiation shielding is required, as well as utilisation of a DT compatible differential pumping system with adjustable throughput to account for the strong pressure variation in the sub-divertor region. Finally, the sub-divertor neutral gas diagnostic will be equipped with multiple Residual Gas Analysers (RGAs), utilising quadrupole mass spectrometry and electrostatic ion-trap-principles, all operating with remote electronics located behind the biological radiation shield. These RGAs will record data in a fast selected discrete mass mode during plasma pulses (cycle ~2 s) and will automatically switch back to continuous data recording (cycle ~100 s) afterwards. They will be complemented by a newly improved Penning gauge spectroscopy configuration in particular supporting the He and D 2 separation relevant for DT operation. The distance between these devices and their associated control unit is typically 15m . A newly developed RGA with a cable length of 80 m, compatible with the ITER environment, will also be employed for the first time. Finally, this set-up and its operation in DTE2 will provide vital input to the development of the ITER divertor RGA in the most relevant environment currently available.

47 OTHER INSTRUMENTATION↗

Sensitivity of cross sections for elastic nucleus-nucleus scattering to halo nucleus density distributions

In order to clear up the sensitivity of the nucleus-nucleus scattering to the nuclear matter distributions in exotic halo nuclei, we have calculated differential cross sections for elastic scattering of the {sup 6}He and {sup 11}Li nuclei on several nuclear targets at the energy of 0.8 GeV/nucleon with different assumed nuclear density distributions in {sup 6}He and {sup 11}Li.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapidity gap cross sections measured with the ATLAS detector in pp collisions at $\sqrt{s} = 7 \mbox{~TeV}$

Pseudorapidity gap distributions in proton-proton collisions at s√=7 ~TeVs=7 ~TeV are studied using a minimum bias data sample with an integrated luminosity of 7.1 μb -1 . Cross sections are measured differentially in terms of Δη F , the larger of the pseudorapidity regions extending to the limits of the ATLAS sensitivity, at η= ±4.9, in which no final state particles are produced above a transverse momentum threshold p$cut\atop{T}$ . The measurements span the region 0<Δη F < 8 for 200~MeV< p$cut\atop{T}$ <800~MeV200~MeV F , the data test the reliability of hadronisation models in describing rapidity and transverse momentum fluctuations in final state particle production. The measurements at larger gap sizes are dominated by contributions from the single diffractive dissociation process (pp→Xp), enhanced by double dissociation (pp→XY) where the invariant mass of the lighter of the two dissociation systems satisfies M Y ≲7 GeV. The resulting cross section is dσ/dΔη F ≈1 mb for Δη F ≳3. The large rapidity gap data are used to constrain the value of the Pomeron intercept appropriate to triple Regge models of soft diffraction. Finally, the cross section integrated over all gap sizes is compared with other LHC inelastic cross section measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of cross sections for mesonless charged-current muon neutrino interactions on argon with and without protons at MicroBooNE

urrent and upcoming neutrino experiments at Fermilab will rely on liquid argon time projection chambers (LArTPCs) as the primary detector technology. To reach the ambitious precision required for their physics goals, a detailed understanding of neutrino-argon scattering must be achieved. For the present Short-Baseline Neutrino program, the dominant reaction channel is charged-current muon neutrino interactions leading to mesonless final states with and without protons. Using a large data set of neutrino interactions recorded by the MicroBooNE LArTPC detector at Fermilab, we report progress towards new measurements of differential cross sections in this channel. The analysis leverages multiple event reconstruction paradigms and observables specifically chosen to maximize sensitivity to nuclear effects of interest for improving neutrino scattering models. Related previous cross-section results from MicroBooNE and a preview of what to expect from the new analysis will both be featured in this presentation.

Liu, Liang [Fermilab]↗

Signal Differentiation of Moving Magnetic Nanoparticles for Enhanced Biodetection and Diagnostics

Magnetic nanoparticles are extensively utilized as markers/signal labelling in various biomedical applications. Detecting and distinguishing magnetic signals from similarly sized moving magnetic nanoparticles in microfluidic systems is crucial yet challenging for biosensing. In this study, we have developed an original method to detect and differentiate magnetic signals from moving superparamagnetic (SPM) and ferrimagnetic (FM) nanoparticles of comparable sizes. Our approach utilizes a highly sensitive magnetic-coil-based sensor that harnesses the combined effects of giant magnetoimpedance (GMI) and an LC-resonance circuit, offering performance superior to that of conventional GMI sensors. Iron oxide nanoparticles, which have similar particle sizes but differing coercivities (zero for SPM and non-zero for FM) or similar zero coercivities but differing particle sizes, flow through the magnetic coil at controlled velocities. Their distinct effects are analyzed through changes in the complex impedance of the sensing system. Our findings provide a unique pathway for utilizing SPM and FM nanoparticles as innovative magnetic markers to identify specific biological entities, thereby expanding their potential applications.

Hwang, Kee Young↗

Massive right-handed neutrinos in $\bar{B} \to D^* τ\bar X$ decay

We explore signatures of a massive right-handed neutrino (RHN) in angular distributions of $\bar{B} \to D^* (\to D π) τ(\to πν_τ) \bar X$ decays, where $X$ is an invisible state. We assume the new physics is described by the standard model effective field theory extended with an RHN in the MeV-GeV mass range. We calculate for the first time the full differential distributions in terms of the visible final states, including the decay of the $τ$ lepton. We evaluate the sensitivity of various distributions to the new physics operators.

FOS: Physical sciences↗

Differential imaging using charge-coupled device (CCD) imagers with on-chip charge storage

A CCD technique is described which allows long integration periods between readouts together with moderate chopping rates. During each phase of a differential chopping cycle, one set of charge images is shifted to the center of the chip, which is light sensitive. At the same time, the other set of charge images is shifted under one of two masked areas which serve as charge-storage sites. Since the vertical shifting between phases can be accomplished in much less time than the typical exposure per phase, there is negligible image smearing. For a given light level and chopping rate the performance of this technique is limited primarily by the readout noise and the vertical charge transfer inefficiency. If many transfer cycles are required between readouts, the charge transfer inefficiency will diffuse the accumulated charge images along the vertical columns. Laboratory and astronomical data obtained with this technique using a CCD camera and the 2.3 m telescope on Kitt Peak are presented.

Stockman, H. S.↗

Growth of high-quality thin-film Ge single crystals by plasma-enhanced chemical vapor deposition

Thin-film Ge single crystals (approx. 10 microns) have been epitaxially grown on polished NaCl(100) substrates at 450C by using plasma-enhanced chemical vapor deposition. Films on approximately 1 sq cm and larger were separated from the NaCl by either melting the salt or by differential shear stress upon cooling to room temperature. The ordered growth of the Ge was found to be most sensitive to the initial plasma power and to the continuum flow dynamics within the carbon susceptor. The films were visually specular and exhibited a high degree of crysalline order when examined by X-ray diffraction. The films were found to be p-type with a carrier concentration of approximately 3 x 10 to the 16th power/cu cm, a resistivity of 0.11 ohm-cm, and a Hall hole mobility of 1820 sq cm/v/s at room temperature. Vacuum firing minimized the primary contaminant, Na, and corresponding lowered the carrier concentration to 4 x 10 to the 14th power/cu cm.

Outlaw, R. A.↗

Compression behavior of delaminated composite plates

The response of delaminated composite plates to compressive in-plane loads was investigated. The delaminated region may be either circular or elliptical, and may be located between any two plies of the laminate. For elliptical delaminations, the axes of the ellipse may be arbitrarily oriented with respect to the applied loads. A model was developed that describes the stresses, strains, and deformation of the sublaminate created by the delamination. The mathematical model is based on a two dimensional nonlinear plate theory that includes the effects of transverse shear deformation. The model takes into account thermal and moisture induced strains, transverse pressures acting on the sublaminate, and contact between the sublaminate and plate. The solution technique used is the Ritz method. A computationally efficient computer implementation of the model was developed. The code can be used to predict the nonlinear-load-strain behavior of the sublaminate including the buckling load, postbuckling behavior, and the onset of delamination growth. The accuracy of the code was evaluated by comparing the model results to benchmark analytical solutions. A series of experiments was conducted on Fiberite T300/976 graphite/epoxy laminates bonded to an aluminum honeycomb core forming a sandwich panel. Either circles or ellipses made from Teflon film were embedded in the laminates, simulating the presence of a delamination. Each specimen was loaded in compression and the strain history of the sublaminate was recorded far into the postbuckling regime. The extent of delamination growth was evaluated by C-scan examination of each specimen. The experimental data were compared to code predictions. The code was found to describe the data with reasonable accuracy. A sensitivity study examined the relative importance of various material properties, the delamination dimensions, the contact model, the transverse pressure differential, the critical strain energy release rate, and the relative growth direction on the buckling load, the postbuckling behavior, and the growth load of the sublaminate.

Peck, Scott O.↗

International Conference on Advances in Communication and Control Systems, 1st, Washington, DC, June 18-20, 1987, Proceedings

Theoretical models of communication and control systems are discussed in reviews and reports. Topics addressed include smoothing and identification for random fields, the information and coding capacities of mismatched Gaussian channels, recursive least-squares estimation and Kalman filtering by systolic arrays, Kemp echo digital filters, a periodic test-scheduling scheme for communication and queuing processes, and receivers for direct-sequence systems. Consideration is given to a distributed-parameter model for detecting cracks in rotors, active control of aeroelastic systems governed by functional differential equations, robust multivariable control of large space structures, finite-rank relatively bounded perturbations of semigroup generators, and sensitivity analysis of convex optimal-control problems.

Declaris, Nicholas↗

Long-Wavelength 640 x 484 GaAs/Al(x)Ga(1-x)As Quantum Well Infrared Photodetector Focal Plane Array Camera

A 9 micrometers cutoff 640 x 484 hand-held quantum well infrared photodetector (QWIP) camera has been demonstrated. Excellent imagery, with a noise equivalent differential temperature (NE.deltaT) of 43 mK has been achieved. In this paper, we discuss the development of this very sensitive long wavelength infrared (LWIR) camera based on a GaAs/AlGaAs QWIP focal plane array (FPA) and its performance in quantum efficiency, NE.deltaT, uniformity, and operability.

Gunapala, S. D.↗

The Deflection Plate Analyzer: A Technique for Space Plasma Measurements Under Highly Disturbed Conditions

A technique has been developed to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The present method is an extension of the capabilities of the Differential Ion Flux Probe (DIFP) to include a mass measurement that does not include either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This reduces the complexity and expense of instrument fabrication, testing, and integration of flight hardware as compared to classical mass analyzers. The new instrument design is called the Deflection Plate Analyzer (DPA) and can deconvolve multiple ion streams and analyze each stream for ion flux intensity (density), velocity (including direction of motion), mass, and temperature (or energy distribution). The basic functionality of the DPA is discussed. The performance characteristics of a flight instrument as built for an electrodynamic tether mission, the Propulsive Small Expendable Deployer System (ProSEDS), and the instrument s role in measuring key experimental conditions are also discussed.

Wright, Kenneth H., Jr.↗

The Deflection Plate Analyzer: A Technique for Space Plasma Measurements Under Highly Disturbed Conditions

A technique has been developed to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The present method is an extension of the capabilities of the Differential Ion Flux Probe (DIFP) to include a mass measurement that does not include either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This reduces the complexity and expense of instrument fabrication, testing, and integration of flight hardware as compared to classical mass analyzers. The new instrument design is called the Deflection Plate Analyzer (DPA) and can deconvolve multiple ion streams and analyze each stream for ion flux intensity (density), velocity (including direction of motion), mass, and temperature (or energy distribution). The basic functionality of the DPA is discussed. The performance characteristics of a flight instrument as built for an electrodynamic tether mission, the Propulsive Small Expendable Deployer System (ProSEDS), and the instrument s role in measuring key experimental conditions are also discussed.

Wright, Kenneth H., Jr.↗