Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Performance of the Lidar Design and Data Algorithms for the GLAS Global Cloud and Aerosol Measurements

The Geoscience Laser Altimeter System (GLAS) launched in early 2003 is the first polar orbiting satellite lidar. The instrument design includes high performance observations of the distribution and optical scattering cross sections of atmospheric clouds and aerosol. The backscatter lidar operates at two wavelengths, 532 and 1064 nm. For the atmospheric cloud and aerosol measurements, the 532 nm channel was designed for ultra high efficiency with solid state photon counting detectors and etalon filtering. Data processing algorithms were developed to calibrate and normalize the signals and produce global scale data products of the height distribution of cloud and aerosol layers and their optical depths and particulate scattering cross sections up to the limit of optical attenuation. The paper will concentrate on the effectiveness and limitations of the lidar channel design and data product algorithms. Both atmospheric receiver channels meet and exceed their design goals. Geiger Mode Avalanche Photodiode modules are used for the 532 nm signal. The operational experience is that some signal artifacts and non-linearity require correction in data processing. As with all photon counting detectors, a pulse-pile-up calibration is an important aspect of the measurement. Additional signal corrections were found to be necessary relating to correction of a saturation signal-run-on effect and also for daytime data, a small range dependent variation in the responsivity. It was possible to correct for these signal errors in data processing and achieve the requirement to accurately profile aerosol and cloud cross section down to 10-7 llm-sr. The analysis procedure employs a precise calibration against molecular scattering in the mid-stratosphere. The 1064 nm channel detection employs a high-speed analog APD for surface and atmospheric measurements where the detection sensitivity is limited by detector noise and is over an order of magnitude less than at 532 nm. A unique feature of the GLAS is a full acquisition of the surface return pulse, which has important application to the atmospheric transmission retrieval.

Spinhirne, James D.↗

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.↗

Documentation of the data analysis system for the gamma ray monitor aboard OSO-H

The programming system is presented which was developed to prepare the data from the gamma ray monitor on OSO-7 for scientific analysis. The detector, data, and objectives are described in detail. Programs presented include; FEEDER, PASS-1, CAL1, CAL2, PASS-3, Van Allen Belt Predict Program, Computation Center Plot Routine, and Response Function Programs.

Croteau, S.↗

A new transition radiation detector for cosmic ray nuclei

Test measurements on materials for transition radiation detectors at a low Lorentz factor are reported. The materials will be based on board Spacelab-2 for determining the composition and energy spectra of nuclear cosmic rays in the 1 TeV/nucleon range. The transition radiation detectors consist of a sandwich of radiator-photon detector combinations. The radiators emit X-rays and are composed of polyolefin fibers used with Xe filled multiwired proportional chamber (MWPC) detectors capable of detecting particle Lorentz factors of several hundred. The sizing of the detectors is outlined, noting the requirement of a thickness which provides a maximum ratio of transition radiation to total signal in the chambers. The fiber radiator-MWPC responses were tested at Fermilab and in an electron cyclotron. An increase in transition radiation detection was found as a square power law of Z, and the use of six radiator-MWPC on board the Spacelab-2 is outlined.

Lheureux, J.↗

Using image area to control CCD systematic errors in spaceborne photometric and astrometric time-series measurements

The effect of some systematic errors for high-precision time-series spaceborne photometry and astrometry has been investigated with a CCD as the detector. The 'pixelization' of the images causes systematic error in astrometric measurements. It is shown that this pixelization noise scales as image radius r exp -3/2. Subpixel response gradients, not correctable by the 'flat field', and in conjunction with telescope pointing jitter, introduce further photometric and astrometric errors. Subpixel gradients are modeled using observed properties of real flat fields. These errors can be controlled by having an image span enough pixels. Large images are also favored by CCD dynamic range considerations. However, magnified stellar images can overlap, thus introducing another source of systematic error. An optimum image size is therefore a compromise between these competing factors.

Buffington, Andrew↗

Testing the Physical Mechanisms of Gamma-Ray Bursts with Multi-Instrument Time-Resolved Spectroscopy

We have continued the project of time-resolved spectral analyses of gamma-ray bursts observed jointly by the BATSE and the Wide-Field Camera on board BeppoSAX. We are making progress understanding the systematic differences between the two data sets. These data comprise the most important joint analysis set for our project. In several meetings, we have reported on metal efforts to understand the blackbody portion of the time series of spectra from GRB970111. Clearly, a fading thermal component can provide a 'seed' spectrum for Compton upscattering. It is very likely the X-ray excess that has been observed previously in BATSE data alone continues into the X-ray band observed by the WFC. We have also made progress in joint fitting of BATSE Large Area Detector and Spectroscopy Detector data with that of the Total Absorption Scintillation Calorimeter (TASC) of the EGRET experiment on CGRO. The TASC data are important to understanding the high-energy response of the BATSE data. We have produced time-sequences of spectra for two important GRB with data from both instruments. The Summer workshop on GRBs at the Aspen Center for Physics provided an opportunity for in-depth discussion of our on-going work. To aid our effort, we continue to make improvements in our spectral analysis software, RMFIT (rewritten from WINGSPAN).

Briggs, Michael S.↗

International Space Station (ISS) Environmental Control and Life Support System (ECLSS) Vent Flow Reflection and Detection by Robotic External Leak Locator (RELL)

On-orbit Robotic External Leak Locator (RELL) (i.e., mass spectrometer and ion gauge) measurements on the International Space Station (ISS) are presented to show the detection of recurring Environmental Control and Life Support System (ECLSS) vents at multiple ISS locations and RELL pointing directions. The path of ECLSS effluents to the RELL detectors is not entirely obvious at some locations, but the data indicates that diffuse gas-surface reflection or scattering resulting from plume interaction with vehicle surfaces is responsible. RELL was also able to confirm the ISS ECLSS constituents and distinguish them from the ammonia leak based on the ion mass spectra and known venting times during its operation to locate a leak in the ISS port-side External Active Thermal Control System (EATCS) coolant loop.

Gas/Surface Reflections or Scattering↗

International Space Station (ISS) Environmental Control and Life Support System (ECLSS) Vent Flow Reflection and Detection by Robotic External Leak Locator (RELL)

On-orbit Robotic External Leak Locator (RELL) (i.e., mass spectrometer and ion gauge) measurements on the International Space Station (ISS) are presented to show the detection of recurring Environmental Control and Life Support System (ECLSS) vents at multiple ISS locations and RELL pointing directions. The path of ECLSS effluents to the RELL detectors is not entirely obvious at some locations, but the data indicates that diffuse gas-surface reflection or scattering resulting from plume interaction with vehicle surfaces is responsible. RELL was also able to confirm the ISS ECLSS constituents and distinguish them from the ammonia leak based on the ion mass spectra and known venting times during its operation to locate a leak in the ISS port-side External Active Thermal Control System (EATCS) coolant loop.

Gas/Surface Reflections or Scattering↗

Response of a tissue equivalent proportional counter to neutrons

The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

UV-sensitive photoemitters.

Far UV transmitting windows, particularly lithium fluoride, and response measurements below 2000 angstroms, noting fabrication on solar blind materials

ULTRAVIOLET PHOTOMETRY↗

Spatial-frequency response of the limb infrared monitor of the stratosphere

Measurements from the Limb Infrared Monitor of the stratosphere (LIMS) are presented and discussed. From the LIMS design model data, the modulation transfer function (MTF) was calculated for the optical system, the detector field mask, the electronics, and the overall system for each channel. The signal output performance of the instrument was predicted from the system MTF data and model input radiance data for each channel. The MTF measurements made on the flight sensor confirmed the analytical results.

Wilson, R. G.↗

A hot-wire method for high-intensity turbulent flows

A measuring technique for determing instantaneous, three-dimensional velocity vectors in highly turbulent flows by means of a 4-sensor hot-wire probe is described. As is well known, the hot-wire signal received in reversing flows cannot uniquely be interpreted. This difficulty is circumvented by tracking the thermal wake of a heated wire. Whenever the approximate flow direction is indicated by a temperature-sensitive wake detector, all components of the instantaneous velocity vector are evaluated by means of a digital data reduction method. Uniqueness of the solution derived from the triple-hot-wire response equations is examined. A first application of the proposed measuring technique in the recirculating flow downstream of a backward-facing step is described.

Mueller, U. R.↗

A new method for using Cf-252 in SEU testing

A system using Cf-252 and associated nuclear instrumentation has determined the single-event upset (SEU) cross section versus linear energy transfer (LET) curve for several 2K x 8 static random access memories (SRAMs). The Cf-252 fission fragments pass through a thin-film organic scintillator detector (TFD) on the way to the device under test (DUT). The TFD provides energy information for each transiting fragment. Data analysis provides the energy of the individual ion responsible for each SEU; thus, separate upset cross sections can be developed for different energy and mass regions of the californium spectrum. This californium-based device is quite small and fits onto a bench top. It provides a convenient and inexpensive supplement or alternative to accelerator and high-altitude/space SEU testing.

Costantine, A.↗

Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

Cucinotta, Francis A.↗

Development of Mirror Modules for the ART-XC Instrument

The Marshall Space Flight Center (MSFC) is developing x-ray mirror modules for the ART -XC instrument on board the Spectrum-Roentgen-Gamma Mission under a Reimbursable Agreement between NASA and the Russian Space Research Institute (IKI.) ART-XC will consist of seven co-aligned x-ray mirror modules with seven corresponding CdTe focal plane detectors. Currently, four of the modules are being fabricated by the Marshall Space Flight Center (MSFC.) Each MSFC module provides an effective area of 65 cm2 at 8 keV, response out to 30 keV, and an angular resolution of 45 arcsec or better HPD. We will present a status of the ART x-ray module development at MSFC.

Gubarev, M.↗

HgCdTe Avalanche Photodiode Array Detectors with Single Photon Sensitivity and Integrated Detector Cooler Assemblies for Space Lidar Applications

A HgCdTe avalanche photodiode (APD) focal plane array assembly with linear mode photon-counting capability has been developed for space lidar applications. An integrated detector cooler assembly (IDCA) has been built using a miniature Stirling cooler. A microlens array has been included to improve the fill factor. The HgCdTe APD has a spectral response from 0.9- to 4.3-μm wavelengths, a photon detection efficiency as high as 70%, and a dark count rate of <250 kHz at 110 K. The mass of the IDCA is 0.8 kg and the total electrical power consumption is about 7 W. The HgCdTe APD arrays have been characterized at NASA Goddard Space Flight Center. A series of environmental tests have been conducted for the IDCAs, including vibration, thermal cycling, and thermal vacuum tests. A description of the device and the test results at NASA are given in this paper.

Sun, Xiaoli↗

Characterization of avalanche photodiodes for lidar atmospheric return signal detectors

Results are presented from tests to characterize noise, dark current, overload, and gain versus bias, relationships of ten avalanche photodiodes. The advantages of avalanche photodiodes over photomultiplier tubes for given laser wavelengths and return signal amplitudes are outlined. The relationship between responsivity and temperature and dark current and temperature are examined. Also, measurements of the noise equivalent power, the excess noise factor, and linearity are given. The advantages of using avalanche photodiodes in the Lidar Atmospheric Sensing Experiment and the Lidar In-Space Technology Experiment are discussed.

Antill, C. W., Jr.↗

US Participation in the GOME and SCIAMACHY Projects

The research performed during this reporting period includes development and maintenance of scientific software for the GOME retrieval algorithms, consultation on operational software development for GOME, further sensitivity and instrument studies to help finalize the definition of the SCIAMACHY instrument, and consultation on optical and detector issues for both GOME and SCIAMACHY. The Global Ozone Monitoring Experiment was successfully launched on the ERS-2 satellite on April 20, 1995, during this reporting period, and is working in the expected fashion. The European Space Agency has made their selections from responses to the Announcement of Opportunity for GOME validation and science studies, part of the overall ERS AO. The Smithsonian Astrophysical Observatory (SAO) proposal has been selected. These proposals are primarily for access to the data; ESA does not provide research funding for the selected investigations. The SAO activities that are carried out as a result of selection by ESA are funded by the present grant, to the limit that can be accomplished at the present level of funding. SCIAMACHY is currently in Phase C/D. Instrument design is almost finalized and selection of infrared detectors from the initial production run has been made.

Chance, K. V.↗