Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “customization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Business Models for Scaling Demand Flexibility Volume I – Value proposition characteristics, challenges, and lessons learned from U.S. programs

Load growth at the grid edge is driving increased attention to the distribution system and its ability to enable customer technology adoption in an affordable and timely manner. Key industry stakeholders, including electric utilities and regulators, can benefit from strategies to manage and balance customer needs with infrastructure investments, such as demand flexibility. This report focuses on demand flexibility—the ability to reduce, shift, shed, generate, or modulate loads in response to building and grid needs—to reduce the need for costly grid upgrades by deferring investment needs and increase system reliability by shifting electricity usage during periods of high risk. Specifically, we focus on the emerging characteristics of business models for demand flexibility as a framework to understand how demand flexibility programs generate value. In this report, we focus on demand flexibility value propositions, which provide information on value creation and describe how programs deliver clear benefits that address customer and grid needs. This report discusses the role of value propositions in demand flexibility programs, provides an overview of value propositions for a range of demand flexibility stakeholders, identifies existing challenges to establishing an effective value proposition, and describes lessons learned. This report is part of a series that includes reports on customer relationship management strategies, stakeholder ecosystem management, and program life cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Business Models for Scaling Demand Flexibility Volume IV – Program life cycle challenges and lessons learned from U.S. programs

Load growth at the grid edge is driving increased attention to the distribution system and its ability to enable customer technology adoption in an affordable and timely manner. Key industry stakeholders, including electric utilities and regulators, can benefit from strategies to manage and balance customer needs with infrastructure investments, such as demand flexibility. This report focuses on demand flexibility—the ability to reduce, shift, shed, generate, or modulate loads in response to building and grid needs—to reduce the need for costly grid upgrades by deferring investment needs and increase system reliability by shifting electricity usage during periods of high risk. Specifically, we focus on the emerging characteristics of business models for demand flexibility as a framework to understand how demand flexibility programs generate value. In this report, we focus on the life cycle of demand flexibility programs, which provides information on value creation and describes the various deployment phases program implementers navigate from initial program conceptualization through to program expansion and replication to new customer segments and regions. This report characterizes the key phases of the demand flexibility program life cycle, identifies existing challenges across the program deployment phases, and describes lessons learned. This report is part of a series that includes reports on customer relationship management strategies, stakeholder ecosystem management, and program life cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tracking the Sun III; The Installed Cost of Photovoltaics in the United States from 1998-2009

Installations of solar photovoltaic (PV) systems have been growing at a rapid pace in recent years. In 2009, approximately 7,500 megawatts (MW) of PV were installed globally, up from approximately 6,000 MW in 2008, consisting primarily of grid-connected applications. With 335 MW of grid-connected PV capacity added in 2009, the United States was the world's fourth largest PV market in 2009, behind Germany, Italy, and Japan. The market for PV in the United States is driven by national, state, and local government incentives, including up-front cash rebates, production-based incentives, requirements that electricity suppliers purchase a certain amount of solar energy, and federal and state tax benefits. These programs are, in part, motivated by the popular appeal of solar energy, and by the positive attributes of PV - modest environmental impacts, avoidance of fuel price risks, coincidence with peak electrical demand, and the possible deployment of PV at the point of use. Given the relatively high cost of PV, however, a key goal of these policies is to encourage cost reductions over time. Therefore, as policy incentives have become more significant and as PV deployment has accelerated, so too has the desire to track the installed cost of PV systems over time, by system characteristics, by system location, and by component. Despite the significant year-on-year growth, however, the share of global and U.S. electricity supply met with PV remains small, and annual PV additions are currently modest in the context of the overall electric system. To address this need, Lawrence Berkeley National Laboratory initiated a report series focused on describing trends in the installed cost of grid-connected PV systems in the United States. The present report, the third in the series, describes installed cost trends from 1998 through 2009, and provides preliminary cost data for systems installed in 2010. The analysis is based on project-level cost data from approximately 78,000 residential and non-residential PV systems in the U.S., all of which are installed at end-use customer facilities (herein referred to as 'customer-sited' systems). The combined capacity of systems in the data sample totals 874 MW, equal to 70% of all grid-connected PV capacity installed in the United States through 2009 and representing one of the most comprehensive sources of installed PV cost data for the U.S. The report also briefly compares recent PV installed costs in the United States to those in Germany and Japan. Finally, it should be noted that the analysis presented here focuses on descriptive trends in the underlying data, serving primarily to summarize the data in tabular and graphical form; later analysis may explore some of these trends with more-sophisticated statistical techniques. The report begins with a summary of the data collection methodology and resultant dataset (Section 2). The primary findings of the analysis are presented in Section 3, which describes trends in installed costs prior to receipt of any financial incentives: over time and by system size, component, state, system ownership type (customer-owned vs. third party-owned), host customer segment (residential vs. commercial vs. public-sector vs. non-profit), application (new construction vs. retrofit), and technology type (building-integrated vs. rack-mounted, crystalline silicon vs. thin-film, and tracking vs. fixed-axis). Section 4 presents additional findings related to trends in PV incentive levels over time and among states (focusing specifically on state and utility incentive programs as well as state and federal tax credits), and trends in the net installed cost paid by system owners after receipt of such incentives. Brief conclusions are offered in the final section, and several appendices provide additional details on the analysis methodology and additional tabular summaries of the data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Selecting Solar: Insights into Residential Photovoltaic (PV) Quote Variation

Before investing in a system, a prospective PV customer must not only have initial concept 'buy in,' but also be able to evaluate the tradeoffs associated with different system parameters. Prospective customers might need to evaluate disparate costs for each system attribute by comparing multiple bids. The difficulty of making such an evaluation with limited information can create a cognitive barrier to proceeding with the investment. This analysis leverages recently available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Economic Analysis Case Studies of Battery Energy Storage with SAM

Interest in energy storage has continued to increase as states like California have introduced mandates and subsidies to spur adoption. This energy storage includes customer sited behind-the-meter storage coupled with photovoltaics (PV). This paper presents case study results from California and Tennessee, which were performed to assess the economic benefit of customer-installed systems. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued.

14 SOLAR ENERGY↗

Supply Chain-Based Solution to Prevent Fuel Tax Evasion: Final Report

The primary source of funding for the United States transportation system is derived from motor fuel and other highway use taxes. Loss of revenue attributed to fuel-tax evasion has been assessed to be somewhere between 1 billion and 3 billion per year. Any solution that addresses this problem needs to include not only the tax-collection agencies and auditors, but also the carriers transporting oil products and the carriers customers. This report presents a system developed by the Oak Ridge National Laboratory (ORNL) for the Federal Highway Administration which has the potential to reduce or eliminate many fuel-tax evasion schemes. The solution balances the needs of tax-auditors and those of the fuel-hauling companies and their customers. The system has three main components. The on-board subsystem combined sensors, tracking and communication devices, and software (the on-board Evidential Reasoning System, or obERS) to detect, monitor, and geo-locate the transfer of fuel among different locations. The back office sub-system (boERS) used self-learning algorithms to determine the legitimacy of the fuel loading and offloading (important for tax auditors) and detect potential illicit operations such as fuel theft (important for carriers and their customers, and may justify the deployment costs). The third sub-system, the Fuel Distribution and Auditing System or FDAS, is a centralized database, which together with a user interface allows tax auditors to query the data submitted by the fuel-hauling companies and correlate different parameters to quickly identify any anomalies. Industry partners included Barger Transport of Weber City, Virginia (fleet); Air-Weigh, of Eugene, Oregon (and their wires and harnesses); Liquid Bulk Tank (LBT) of Omaha, Nebraska (three five-compartment trailers); and Innovative Software Engineering (ISE) of Coralville, Iowa(on-board telematics device and back-office system). ORNL conducted a pilot test with the three instrumented vehicles collecting real-world data during an eight-month period (October 2014 to June 2015). The vehicles logged a total of 375,000 miles and transported more than 7.5 million gallons of fuel. The drivers entered information on the telematics device about 77% of the time, with about 15% (10%) of the data showing at least one compartment with loading (offloading) valve activity, but not driver information entry for that compartment. Seven events (or about 0.7% of the trips) were identified by the boERS as having a missing fuel diversion number. The solution developed and tested in the pilot test had federal- and state-level tax auditors as its main audience. Nonetheless, the technology has to be adopted by the fuel carriers and therefore the solution had to address the needs of fuel-hauling companies and their customers (i.e., fuel theft and cocktailing). Sensors in the hatches allowed the obERS recognize when one of those were opened (always a suspicious activity, unless it happens at locations where maintenance is performed on the vehicle). The fuel-theft issue was addressed by a self-learning algorithm deployed on the boERS that continuously processed the data from the field to construct probability distributions of measures such as elapsed time of fuel loading and offloading by driver, vehicle, and compartment, valve actuation sequence, elapsed time between the first two valve actuations (by driver, compartment, and location), and other parameters. Probability thresholds, which can be set up by the carrier, determined how to classify the observed events. The boERS also kept track of valve sequencing at a given location and analyzed these actuations to help identify any suspicious activities. Technical and economic recommendations include: a) simplification of the driver data-entry task; b) reduction of system deployment cost; c) addition of capabilities that make the system more appealing to industry (i.e., identify and avoid fuel misdelivery); and d) incorporation of additional capabilities to the FDAS. Path to commercialization recommendations include: a) identify a company willing to further develop, test, and certify a hardened system with a price point the market will bear; b).transfer ERS to licensee; c) establish a fleet or fleets who want this technology for carrier benefits or trailer manufacturer who wants to offer it as optional technology; and d) identify a location for the deployment of FDAS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

State Approaches to Demand Reduction Induced Price Effects: Examining How Energy Efficiency Can Lower Prices for All

Effects (DRIPE) as a real, quantifiable benefit of energy efficiency and demand response programs. DRIPE is a measurement of the value of demand reductions in terms of the decrease in wholesale energy prices, resulting in lower total expenditures on electricity or natural gas across a given grid. Crucially for policymakers and consumer advocates, DRIPE savings accrue not only to the subset of customers who consume less, but to all consumers. Rate-paying customers realize DRIPE savings when price reductions across an electricity or natural gas system are passed on to all retail customers as lower rates (depending upon regulation and market structure, residual savings may be wholly or partially retained by utilities). DRIPE savings, though seemingly small in terms of percent price reductions or dollars per household, can amount to hundreds of millions of dollars per year across entire states or grids. Therefore, accurately assessing DRIPE benefits can help to ensure appropriate programs are designed and implemented for energy efficiency measures. This paper reviews the existing knowledge and experience from select U.S. states regarding DRIPE (including New York and Ohio), and the potential for expanded application of the concept of DRIPE by regulators. Policymakers and public utility commissions have a critical role to play in setting the methodology for determining DRIPE, encouraging its capture by utilities, and allocating DRIPE benefits among utilities, various groups of customers, and/or society at large. While the methodologies for estimating DRIPE benefits are still being perfected, policymakers can follow the examples of states such as Maryland and Vermont in including conservative DRIPE estimates in their resource planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Technical Report for EE0006091: H2Pump Hydrogen Recycling System Demonstration

The objective of this project is to demonstrate the product readiness and to quantify the benefits and customer value proposition of H2Pump’s Hydrogen Recycling System (HRS-100™) by installing and analyzing the operation of multiple prototype 100-kg per day systems in real world customer locations. The data gathered will be used to measure reliability, demonstrate the value proposition to customers, and validate our business model. H2Pump will install, track and report multiple field demonstration systems in industrial heat treating and semi-conductor applications. The customer demonstrations will be used to develop case studies and showcase the benefits of the technology to drive market adoption.

08 HYDROGEN↗

The SURE House (Solar Decathlon 2015)

Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable architecture for New Jersey and beyond. This is what informed the architectural design of the house. Configured about a compact form, thickly insulated and air-sealed walls eliminate thermal bridging and minimize energy losses while advanced glazing brings in free solar heat during the winter months. As a result of these passive design strategies, the SURE HOUSE has a greatly reduced carbon footprint requiring 91% less energy than a typical New Jersey home. Photovoltaic (PV) arrays on both the rooftop and operable shutters easily provide energy in excess of the home’s modest demands. The Stevens team considers a truly sustainable home in the era of climate change, one that prioritizes low energy use, and integrates right-sized renewable generation to supply the home’s needs. Low consumption, low production. RESILIENT In October of 2012, Hurricane Sandy wreaked havoc along the east coast of the US. In New Jersey alone there was an estimated 29.4 billion dollars in damages, 346,000 homes affected, and almost two and a half million people left without power, in some cases for over 10 days. Recovery from this storm and associated flooding is ongoing to this day, as many New Jersey homeowners grapple with the large costs of rebuilding and struggle to adapt to complicated new home building regulations. Damage from this storm to Hoboken, the home of the Stevens Institute of Technology’s campus, and to the New Jersey shore was extensive and many students on the SURE HOUSE team were directly affected by this historic event. The Stevens design team recognizes that in a world of more frequent and stronger storms, the ability to absorb and adapt to change is more important than ever. Successfully weathering the next storm and its aftermath is one of the primary goals in the design of the SURE HOUSE prototype. The SURE HOUSE introduces unique ‘dry flood-proofing’ methods to residential construction. Innovative wall and floor flood-proofing, utilizing durable composite sheathing materials adapted from the boating industry, were developed by the student team to render the SURE House’s building envelope flood proof up to the FEMA AE 6/7 Zone (+ 6/7 feet of water above sea-level). Designed and fabricated utilizing glass-fiber composite materials, the custom storm shutter system serves to protect the large glazed openings of the home from both air-borne debris impact and water infiltration during a storm event while also providing deterrence from the vandalism that often occurs in the aftermath of a calamitous event. During extended power outages, a ‘resilient’ solar array is capable of supplying critical amounts of energy and hot water to the home, without the use of battery storage or grid infrastructure. PV Description AC GRID-TIED PV SYSTEM The SURE HOUSE solar system consists of two distinct arrays, the grid-tied rooftop array which produces AC Powerand the shutter-mounted array which converts DC power generated by the modules directly into usable heat for the domestic hot water (DHW). The roof-mounted AC grid-tied array is comprised of three strings, two 11 module strings connected to an SMA SB 5000TL-US-223 inverter and a single 10 module string equipped and an SMA SB 3000TL-US-22 central inverter. All modules for the rooftop AC array are LG MonoX 2804 watt solar panels, chosen for their durability and efficiency. Inverter sizing and string size are optimized to the electrical characteristics of the chosen PV modules and the desired energy production, see Appendix 5B. The SURE HOUSE is projected to produce 12,353 kWh per year to meet 6,157 kWh per year of estimated consumption. Solar modules for the two AC grid-tied sub arrays are mounted on the main roof surface of the SURE HOUSE with a 10 degree tilt angle using a partially-ballasted polyethylene roof mounting system made by Renusol, which is particularly suited to the corrosive salt air of a coastal environment. This method was chosen for its installation simplicity and to limit detrimental roof penetrations. The 10 degree tilt optimizes the energy generated per roof area at a lower price, see Appendix 5A, and ensures that there is minimal wind uplift. DC SOLAR ELECTRIC DOMESTIC HOT WATER The SURE HOUSE’s approach to sustainable and resilient domestic hot water (DHW) consists of a unique, custom engineered DC solar electric hot water system. Employing the use of Advanced Energy’s DC electric PV heater (DCPVH)5 to heat domestic water well beyond the draw temperature, the SURE HOUSE is able to obtain a remarkably high solar fraction of 75% or more. The custom modified 80 gallon Vaughn DHW tank acts as a large solar ‘battery’ that stores heat energy in the form of hot water at almost 150 degrees, harvesting energy when the sun is out for use later in the day or overnight. The system, which uses electricity rather than heated fluid, is distinct from traditional ‘solar thermal’ systems by eliminating the dangers and associated maintenance issues of fluid based systems. By forgoing the use of external fluid loops, overheated solar collectors and pipes are not an issue for the SURE HOUSE system which never needs any yearly or seasonal flushing. In weather conditions where the integrated DCPVH unit cannot produce enough hot water via solar energy alone, the Vaughn hot water tank comes factory made with an AC powered 2.6 COP heat pump and a AC heating coil that serve as back-up heating elements. The DCPVH is powered by a DC array consisting of 10 custom-made Solbian by PVilion 180 watt, monocrystalline, flexible solar modules6. The Solbian modules are directly mounted to the top half of the operable storm shutters on the south façade of the SURE HOUSE. The SURE HOUSE team worked closely with PVillion, a PV system designer specializing in flexible architectural photovoltaics, to design an adhesive system that works with the glass-fiber storm shutter surface in a reliable manner over an extended period. Because this system operates in DC-only mode and never connects to the municipal power grid, the system can continue to create hot water safely and effectively even during grid disruption events. This hot water, and the energy stored within it, could be used for a range of activities including washing and cooking to more elaborate hydronic heating systems as desired. See Appendix 6 for system engineering, sizing and modeling.

14 SOLAR ENERGY↗

Riding the Electricity Market as an Energy Management Strategy: Savings from Real-Time Pricing

Dynamic pricing of electricity, in which retail prices facing customers are responsive to changes in the underlying wholesale markets, represents a step towards economic efficiency in that customers get exposed to some or all of the costs facing wholesale market players. But what do customers who opt for this greater exposure – available in the roughly 15 “de-regulated” states, as well as, to some extent, from some regulated utilities – get in return for their risks? The U.S. General Services Administration (GSA) took a retrospective eight-year look at what the savings would have been had they let the loads for which they purchase electricity in the Washington, DC area buy electricity on the real-time pricing (RTP) market – the dynamic pricing option with the highest risk – as opposed to the strategy they chose in actuality, which was fixing flat prices with 3rd-party providers. We found that opting for RTP for the eight years of the study (2005 through 2012) would have resulted in 17% savings, or almost a quarter of a billion dollars, relative to GSA’s actual prices from the 3rd-party suppliers. This is particularly astonishing given that GSA appeared to have timed the market well during the study period, consistently beating the standard offer products provided by the distribution utilities. The issue of budgetary predictability poses an obstacle for customers (especially government ones) considering RTP and, to a lesser extent, other dynamic pricing options. Indeed, GSA would have lost money with RTP in two of the eight years, one of them substantially. But the magnitude of the savings is indisputably compelling and, even if it may be somewhat aberrational due to high congestion in the DC market, begs consideration by large electricity users currently paying to “lock in” fixed flat prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transactive System Program Communication System Cost Model

Transactive energy is an economics and controls technique that aims to dynamically manage the generation and consumption of electricity within the power system. Much research has been done in the area of demonstrating the capability and performance of transactive systems, as well as valuing the benefits a transactive system can provide. Significantly less research has been done in the area of estimating the costs of a transactive system. This work aimed to build a model that would estimate the costs of the communications system that would be necessary to support a transactive system and be realized by a local utility. Dynamic pricing, and a customer’s response to this pricing, is a key aspect of a transactive system; this would require a two-way communication system between utilities and customers. Since the system will vary based on many factors, the cost model was consequently designed for use in a wide variety of applications. The cost model requires some basic user inputs regarding the system being analyzed, such as location and size. The user also identifies one or more generic circuit models that best represent the system. Additionally, a user can, but is not required to, change assumed equipment and installation costs and equipment lifetime within the model. These inputs will result in 20 year cost estimates for three different communication technologies that are capable of supporting the bandwidth needs of a transactive energy system. The three communication systems included in the model are cellular, fiber optic and wireless mesh. Each vary significantly from one another and offer unique advantages and barriers. A cellular network avoids high upfront costs, but is limited to areas where there is coverage by the service provider and subject to the ongoing rate established with the service provider. A fiber optic system requires a large up-front cost, but it will provide a reliable system to areas where cellular and mesh may be unable to do so. Additionally, fiber provides more bandwidth than necessary for transactive systems and can offer additional business opportunities. A mesh system can be installed for less upfront costs than fiber and offers enough bandwidth to support a transactive system, but the ability to model this technology is done with less certainty than the other two options. The estimated costs include the communication system that connects the customers to their nearest substation, in addition to the smart meter and radio that would be required for each customer. The communications from the substation to the utility are not included in estimates, as the need for upgrading that system would be assessed on a case-by-case basis. Although the cost of the smart meter and radio is included, no other appliance specific cost is included in the estimate provided by the model. The communication system is a key aspect of the development of a transactive system. This work resulted in easily being able to estimate the costs of a communication system specific to the system being studied. This cost model will aid ongoing valuation and simulation work in the field of transactive energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Light-Duty Fuel Cell Electric Vehicle Validation Data (Final Report)

Since 2005, Mercedes-Benz Research & Development North America (MBRDNA) participated in the DOE’s Technology Validation Programs to help accelerate the market introduction of fuel cell vehicles. Under the U.S. Department of Energy (DOE) contract DE-EE0005971, which ran from 2013 - 2019, MBRDNA collaborated with the DOE to evaluate overall vehicle degradation effects of fuel cell vehicles, as well as evaluate the generational improvements from one vehicle generation to another. The goal was to achieve a mileage target of 10,000-12,000 miles per vehicle per year and 750 to 1,000 operating hour accumulation per fuel cell stack. The MBRDNA Project Team (Project Team) leased a total of 69 fuel cell vehicles to regular Mercedes-Benz customers through select dealerships in Northern and Southern California. Of these 69 vehicles, a minimum of 20 active vehicles were chosen to participate in this project based on customer driving habits, average daily miles, and geographic conditions. These vehicles were equipped with a data acquisition system that automatically collected statistically relevant data for submission to the National Renewable Energy Laboratory, which monitors the progress of fuel cell vehicle technology for the DOE. As customer operation of GEN II vehicles ended in Q4 2017, a decision was made to focus GEN III vehicle operation in Europe and Japan only, and not to deploy the vehicle in the United States. Despite the intention to include three GEN III vehicles in durability runs in Southern California for purposes of data collection for this project, the plan could not be realized given the decision not to deploy GEN III vehicles in the U.S. market at this time. In total, over 1.3 million miles and 60,000 operational hours of fuel cell system and powertrain operation were submitted to DOE under this project. The data provided revealed insights into real-world customer operation and system durability of fuel cell vehicles, enabling the DOE to observe the technology maturity and readiness of fuel cell vehicles outside of the controlled corporate research and development environment. Mercedes-Benz Research and Development North America (MBRDNA) has been promoting fuel cell technology in the U.S. since 2000. Over this time, it has been a pleasure to work in conjunction with the Department of Energy (DOE) on two separate projects surrounding fuel cell vehicle and market readiness. MBRDNA looks forward to future opportunities to collaborate in the interest of helping to further a sustainable transportation future.

08 HYDROGEN↗

Current Developments in Retail Rate Design: Implications for Solar and Other Distributed Energy Resources

Retail electricity pricing is evolving in the context of broader shifts in how electricity customers pay for grid services and how they are compensated for customer-sited generation. This evolution has been prompted by a broad set of factors, chief among them being: widespread adoption of advanced metering infrastructure (AMI), increased customer investment in solar and other distributed energy resources (DERs), concerns about utilities’ fixed cost recovery and revenue sufficiency in an era of flat or declining load growth, and significant changes to utilities’ hourly net load profiles and operational needs as greater amounts of variable renewable energy (VRE) resources connect to the grid. This report discusses five current retail rate design trends among residential and commercial customer classes that have emerged, at least in part, in response to those drivers, and uses case studies to illustrate key motivations, variations in rate design, and aspects of implementation experience.

14 SOLAR ENERGY↗

Cost Recovery for Standby and Ancillary Services for Distributed Generation: Considerations for New Mexico

A New Mexico statute allows investor-owned utilities to recover costs of “standby and ancillary services” resulting from distributed generation (DG). In attempting to do so, it is important to recognize both the physical and economic impacts, positive and negative, that distributed generation creates. Distributed generation has different impacts on ancillary and standby services depending on the location, capacity, and production patterns of the systems. Low penetrations of small distributed generation systems will not create significant contingencies for utilities. System impact of fluctuations in DG production may be no larger than normal fluctuations caused by customer demand, such as an air conditioner cycling. Higher penetrations and large DG system may produce noticeable impacts; so magnitude is critical when determining potential additional recoverable utility costs. Understanding DG impact on ancillary services is a relatively new and emerging area of study and as such there are not well-established formulas or protocols. Discretion is required. A hosting capacity analysis can help determine how much DG can be implemented before the impacts become substantive. Standby rates are traditionally used for large industrial generators or combined heat and power systems and threshold system size levels are often used in determining applicability of standby rates. System size thresholds may also be appropriate for standby rates and DG. Relatively small, geographically diverse DG systems are unlikely to create a noticeable coincident outage, so developing a standby charge based on assumed coincidence may not be appropriate. Individual lines and feeders may have considerable excess capacity during coincident outages, or they may be fully utilized and facing upgrades in the near future, which could vary over time. Understanding specific events that create concern for utilities is critical to developing an appropriate rate mechanism (e.g., single residential or community system outage, cascading event, clouds, eclipse). Any modeling or studies of the grid should also recognize the unique situation created when DG is coupled with a smart inverter or storage. These devices change the value proposition and can help mitigate some of the voltage and ramping issues DG can pose for a utility. Utilities can recover their fixed costs in a variety of ways, and some are better suited for DG than others. Beyond charging for standby and ancillary services, other options include fixed customer charges, demand charges, minimum bills, time-of-use rates and updated net energy-metering policies. Studies and analyses of the specific impacts that DG has on the grid should inform utilities’ decision-making process because distributed generation creates both costs and benefits for the grid. Any charge specific to DG customers should be backed up with analysis. At the heart of this conversation is utilities attempting to recover fixed costs. Allowing utilities to indiscriminately recover all stranded fixed costs can negatively affect long-term market efficiency by blunting utility incentives to lower costs and acting as a barrier to entry and exit. The current status of New Mexico’s grid, impending infrastructure updates, and likely customer adoption patterns for DG (backed up by transparent analysis) should remain at the forefront when considering charges for standby and ancillary services. Recognizing that utility regulation is largely a reactive process, it is recommended that applications for DG related standby or ancillary services cost recovery mechanisms be thoroughly reviewed by an experienced economist. If the commission has no such skill set on staff, one might be hired.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voluntary Renewable Energy Procurement Programs in Regulated Utility Markets

Multinational corporations are increasingly purchasing renewable energy (RE) to fulfill international commitments, reduce supply chain emissions, limit environmental impact, and secure stable and affordable electricity. The potential scale of global corporate RE purchasing has been estimated to be nearly 100 GW and growing; however, many markets still lack supportive enabling environments for corporations to access RE through on-site project development or private sector transactions. Even where allowed by law, on-site generation may be insufficient due to space and technical constraints, introducing additional challenges. Utility green pricing and utility green tariff programs backed by renewable energy certificates (RECs), referred to as utility green procurement programs (GPPs) in this report, offer powerful market-based solutions to utilities, regulators, and policymakers to provide corporate and other consumers with RE product options while generating revenue to support RE development. As RE markets expand around the globe, GPPs have proven to be effective mechanisms in market regimes, ranging from fully integrated state-owned utilities to broadly liberalized power markets. GPPs utilize RECs, which are a type of energy attribute certificate and closely resemble guarantees of origin, to track and ultimately monetize RE attributes that corporations and other buyers must procure to demonstrate progress against their RE commitments and make public claims of RE use. Time-tested and transparent REC accounting mechanisms provide market confidence, while at the same time offering flexibility to utilities, regulators, and customers for a range of applications. RECs are used in all types of electricity market structures, as indicated in Figure 1, but REC-based program designs and supporting components differ depending on the type of market. Liberalized markets allow for customers to contract directly with generators for electricity and RECs, while traditionally regulated markets with vertically integrated utility structures may have greater restrictions on generation asset ownership and electricity sales. RE markets can be further defined as being either mandatory or voluntary. Mandatory markets require suppliers to deliver specified amounts of RE to grid customers, such as under a renewable portfolio standard (RPS), while voluntary markets involve no legal mandates, but demand is driven by self-imposed customer goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

Wyandotte Integrated Renewable Energy Strategy (WIRES 2) (Final Technical Report)

Wyandotte Municipal Services (WMS), a Michigan Municipal Utility offering electric generation, transmission & distribution, water filtration & distribution and Broadband/Video sought to deploy a set of renewable energy projects for their Electric Utility that contributed to reducing the City’s environmental and energy impact, provided examples that would encourage businesses and citizens to adopt cleaner energy practices and help WMS meet the required renewable energy standards of the State of Michigan (10% in 2015, 15% in 2021). WMS generates and delivers roughly 280,000 megawatt hours (MWh) of electricity annually to more than 10,000 homes and 1,000 businesses within the City of Wyandotte. The Wyandotte Integrated Renewable Energy Strategy – WIRES 2 resulted in deployment of a set of community-scale micro-wind turbines, evaluation and installation of energy-efficient and low-maintenance light-emitting diode (LED) street lights and park lights in highly visible locations in the City and expansion of the geothermal heating and cooling district that already included residential geothermal systems, to include larger scale business/institutional systems at the Utility’s largest electric customer and at the City Library. Finally, WMS identified the need for job training in energy efficiency and renewable energy technologies to further develop a local skilled workforce in these areas. Partially funded by the grant, the wind turbine project provides a benchmark for WMS, local businesses and residents in the evaluation of utility-scale wind v. micro-wind in an urban environment as a renewable energy strategy. Also partially funded by the grant, the LED project benefited the City of Wyandotte by reducing load on the electric system for the public utility but also reduced City costs for streetlighting, parking lot lighting and park lighting without a compromise in security. The project also resulted in a visual success that has led to additional approvals for non-Grant related LED lighting installations resulting in further reduction in the electric load in the City. Commercial Geothermal installations resulted in the Utility being able to eliminate steam customers who formerly utilized the byproduct of steam from WMS electric production. Due to the reduction in natural gas prices and the overall reduction in market purchased power, it was no longer feasible for WMS to operate its Power Plant as a base load plant and to only operate on a market dispatch philosophy when market prices dictated that WMS could produce electricity cheaper than the market purchase price. This has resulted in fewer operating days for the WMS Power Plant, resulting in less environmental impact. WMS has now completely exited the steam business and the ability to offer a geothermal option to two (2) former steam customers (BASF-Wyandotte and the Bacon Memorial Library) allowed for that. In addition, peak loads have been shaved for these two (2) large customers due to the consistent temperature offered by geothermal heating and cooling, reducing the swings associated with thermostat changes caused by outside temperature changes during extreme high and low temperatures. Finally, energy efficiency and renewable energy college-level classes at Wayne County Community College allowed a group of interested students to pursue studies in those technologies through grant provided tuition, books and course materials. This effort provided a foundation of potential future employees not only for WMS but other energy efficiency/renewable energy employers such as Franklin Energy, a partner with WMS in energy optimization efforts with Wyandotte businesses.

17 WIND ENERGY↗

Processing Meteorological Data for the CAP-88 PC Model at Los Alamos National Laboratory

The Environmental Protection and Compliance-Compliance Programs (EPC-CP) group at Los Alamos National Laboratory (LANL) uses the Clean Air Act Assessment Package 1988 (CAP-88, Littleton 2020) PC model (Version 4.1) to estimate radiological doses for a set of areal sectors surrounding a release location, in order to satisfy the Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAP) dose calculation requirement in 40 CFR 61 Subpart H. Among several types of data that must be prepared for CAP-88 input is a text file of meteorological data (“WIND” file), consisting of the joint frequency of wind direction, wind speed, and atmospheric stability categories. EPC-CP produces customized WIND files by running a CAP-88 utility program on a user generated text file of wind data in a different format, known as a STability ARray (STAR) file (Turner, 1964). At LANL, EPC-CP meteorologists prepare customized STAR files with data over desired time periods at selected meteorological towers. A custom program written in Precision Visuals -Workstation Analysis and Visualization Environment (PV-WAVE), a commercial Fortran-like language, is used to read LANL meteorological data and write a STAR file; the executable filename is “Star.out”. However, the outdated PV-WAVE utility program is being phased out by EPC-CP, due to the inefficient process to run it and an inability to modify the code. To preserve the ability to create customized meteorological data for CAP-88 in a way that will be easy to use and maintain, a new replacement utility program, written in the Python programming language, has been developed. The new, improved program reads a data file from any LANL meteorological tower, and at each desired observation time, determines the wind direction, wind speed, and stability categories defined in the CAP-88 documentation. The frequencies of all combinations of the three sets of categories are calculated and written to a file in the STAR format, which can later be converted to a WIND file for input into CAP-88.

54 ENVIRONMENTAL SCIENCES↗