Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Northwest Open Automated Demand Response Technology Demonstration Project

Lawrence Berkeley National Laboratory (LBNL) and the Demand Response Research Center (DRRC) performed a technology demonstration and evaluation for Bonneville Power Administration (BPA) in Seattle City Light's (SCL) service territory. This report summarizes the process and results of deploying open automated demand response (OpenADR) in Seattle area with winter morning peaking commercial buildings. The field tests were designed to evaluate the feasibility of deploying fully automated demand response (DR) in four to six sites in the winter and the savings from various building systems. The project started in November of 2008 and lasted 6 months. The methodology for the study included site recruitment, control strategy development, automation system deployment and enhancements, and evaluation of sites participation in DR test events. LBNL subcontracted McKinstry and Akuacom for this project. McKinstry assisted with recruitment, site survey collection, strategy development and overall participant and control vendor management. Akuacom established a new server and enhanced its operations to allow for scheduling winter morning day-of and day-ahead events. Each site signed a Memorandum of Agreement with SCL. SCL offered each site $3,000 for agreeing to participate in the study and an additional $1,000 for each event they participated. Each facility and their control vendor worked with LBNL and McKinstry to select and implement control strategies for DR and developed their automation based on the existing Internet connectivity and building control system. Once the DR strategies were programmed, McKinstry commissioned them before actual test events. McKinstry worked with LBNL to identify control points that can be archived at each facility. For each site LBNL collected meter data and trend logs from the energy management and control system. The communication system allowed the sites to receive day-ahead as well as day-of DR test event signals. Measurement of DR was conducted using three different baseline models for estimation peak load reductions. One was three-in-ten baseline, which is based on the site electricity consumption from 7 am to 10 am for the three days with the highest consumption of the previous ten business days. The second model, the LBNL outside air temperature (OAT) regression baseline model, is based on OAT data and site electricity consumption from the previous ten days, adjusted using weather regressions from the fifteen-minute electric load data during each DR test event for each site. A third baseline that simply averages the available load data was used for sites less with less than 10 days of historical meter data. The evaluation also included surveying sites regarding any problems or issues that arose during the DR test events. Question covered occupant comfort, control issues and other potential problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reliability Assessment of Graphite Specimens under Multiaxial Stresses

An investigation was conducted to predict the failure strength response of IG-100 nuclear grade graphite exposed to multiaxial stresses. As part of this effort, a review of failure criteria accounting for the stochastic strength response is provided. The experimental work was performed in the early 1990s at the Oak Ridge National Laboratory (ORNL) on hollow graphite tubes under the action of axial tensile loading and internal pressurization. As part of the investigation, finite-element analysis (FEA) was performed and compared with results of FEA from the original ORNL report. The new analysis generally compared well with the original analysis, although some discrepancies in the location of peak stresses was noted. The Ceramics Analysis and Reliability Evaluation of Structures Life prediction code (CARES/Life) was used with the FEA results to predict the quadrants I (tensile-tensile) and quadrant IV (compression-tension) strength response of the graphite tubes for the principle of independent action (PIA), the Weibull normal stress averaging (NSA), and the Batdorf multiaxial failure theories. The CARES/Life reliability analysis showed that all three failure theories gave similar results in quadrant I but that in quadrant IV, the PIA and Weibull normal stress-averaging theories were not conservative, whereas the Batdorf theory was able to correlate well with experimental results. The conclusion of the study was that the Batdorf theory should generally be used to predict the reliability response of graphite and brittle materials in multiaxial loading situations.

Sookdeo, Steven↗

German experiences in local fatigue monitoring

The ageing management of nuclear power plants (NPP) has gained an increasing importance in the last years. The reasons are mainly due to the international context of extending period of plants operation. Moreover, new scientific discoveries, such as the corrosive influence of the medium on the fatigue process (environmentally assisted fatigue - EAF) play an important role and influence the code development (ASME, EAF code cases). The fatigue damage process takes a central position in ageing mechanisms of components. It must be ensured through appropriate evidence that facilities are being operated under allowable boundary conditions. In the design phase of NPP, fatigue analyses are still based on theoretical considerations and empirical values, which are summarized in the design transient catalogue, necessary for licensing. These analyses aim at proving the admissibility of the loads in terms of stress and fatigue usage. These analyses will also provide the fatigue-relevant positions in the NPP and give a basis for future design improvements and optimization of operating modes. The design transients are in practice conservatively correlated with the real transients occurring during operation. Uncertainties reveal very conservative assumptions regarding forecast temperatures, temperature gradients and frequencies of events. During operation of the plant, it has to be recurrently proved, that the plant is being operated under designed boundary conditions. Moreover, operating signals are constantly acquired to enable a fatigue evaluation. For example, in Germany fatigue evaluation is based on decades of experience and regulatory requirements. The rule KTA 3201.4 [1] establishes the rules for qualified fatigue monitoring. The rule DIN 25475-3 [2] on fatigue monitoring systems is available in draft version. Experience shows that some significant differences occur between the design transients and the real occurred transients during plant operation. The reasons for it are the various manual control options and also different operating modes. It is clear that showing the covering of real loads by design loads, requires a relatively complex and well-qualified detection process. The difficulty of this task is increased due to the lack of data or incomplete information and the exclusive reliance on existing operation plant data. The strategy of employing local fatigue monitoring is a straightforward solution enabling the direct measurement of loads on the fatigue-sensitive zones. Nowadays a direct derivation of the complete stress tensor at the fatigue-relevant locations is enabled thanks to the recorded local loads and combination with finite element (FE) analyses. So, additionally to the recorded temperature curves, a representation of the time evolution of the six stress components for each monitored component is possible. This allows the application of the simplified elasto-plastic fatigue check according to design codes. The fatigue level can be realistically analyzed with a suitable cycle-counting method. Furthermore, the knowledge of the time evolution of the stresses and strains enables to take into account an environmental factor to include the corrosive fluid influence in the calculations. Without local recording, it is impossible to calculate realistic fatigue usage. AREVA offers the AREVA fatigue concept (AFC) and the new fatigue monitoring system integrated (FAMOSi), necessary tools to monitor local fatigue and to provide realistic assessment. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grey-box modeling and application for building energy simulations - A critical review

Grey-box modeling, as one of the three fundamental modeling techniques for building energy models, has many advantages compared with black-box modeling and white-box modeling. Additionally, it has been widely applied to solve problems of building technologies, such as building load estimation, control and optimization, and building-grid integration. However, a thorough review of grey-box modeling is not available. This review study systematically investigated various aspects of grey-box modeling for buildings. First, the fundamental aspects of grey-box modeling are presented, including the theoretical background, modeling of building elements, modeling order, modeling diagram, and order reduction. Second, the detailed modeling approaches are discussed. Third, multiple applications of grey-box modeling are investigated for building energy domain, which are categorized into the following groups: heat dynamics analysis, thermal load estimation, building control and optimization, district/urban scale energy modeling, and building-grid integration. Finally, the available software packages for grey-box modeling are compared. Overall, the challenges of using grey-box modeling can be summarized as follows: (1) the theoretical limitations and assumptions of grey-box modeling are unclear; (2) grey-box model naming convention and structure are confusing; (3) grey-box model creation is vague; (4) suitable applications of grey-box models are unknown; and (5) grey-box models lack unified software solutions for wider adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EFFECT ON 105KW NORTH WALL DUE TO ADDITION OF FILTRATION SYSTEM

CHPRC D&D Projects is adding three filtration system on two 1-ft concrete pads adjacent to the north side of existing KW Basin building. This analysis is prepared to provide qualitative assessment based on the review of design information available for 105KW basin substructure. In the proposed heating, ventilation and air conditioning (HVAC) filtration pad designs a 2 ft gap will be maintained between the pads and the north end of the existing 1 05KW -Basin building. Filtration Skids No.2 and No.3 share one pad. It is conservative to evaluate the No.2 and No.3 skid pad for the wall assessment. Figure 1 shows the plan layout of the 105KW basin site and the location of the pads for the filtration system or HVAC skids. Figure 2 shows the cross-section elevation view of the pad. The concrete pad Drawing H-1-91482 directs the replacement of the existing 8-inch concrete pad with two new 1-ft think pads. The existing 8-inch pad is separated from the 105KW basin superstructure by an expansion joint of only half an inch. The concrete pad Drawing H-1-91482 shows the gap between the new proposed pads and the north wall and any overflow pits and sumps is 2-ft. Following analysis demonstrates that the newly added filtration units and their pads do not exceed the structural capacity of existing wall. The calculation shows that the total bending moment on the north wall due to newly added filtration units and pads including seismic load is 82.636 ft-kip/ft and is within the capacity of wall which is 139.0ft-kip/ft.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frost Growth CFD Model of an Integrated Active Desiccant Rooftop Unit

A frost growth model is incorporated into a Computational Fluid Dynamics (CFD) simulation of a heat pump by means of a user-defined function in FLUENT, a commercial CFD code. The transient model is applied to the outdoor section of an Integrated Active Desiccant Rooftop (IADR) unit in heating mode. IADR is a hybrid vapor compression and active desiccant unit capable of handling 100% outdoor air (dedicated outdoor air system) or as a total conditioning system, handling both outdoor air and space cooling or heating loads. The predicted increase in flow resistance and loss in heat transfer capacity due to frost build-up are compared to experimental pressure drop readings and thermal imaging. The purpose of this work is to develop a CFD model that is capable of predicting frost growth, an invaluable tool in evaluating the effectiveness of defrost-on-demand cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Modeling Describing the Effects of Heterogeneous Distributions of Asperities on the Quasi-static Evolution of Frictional Slip

A better understanding of how slip accumulates along faults and its relation to the breakdown of shear stress is beneficial to many engineering disciplines, such as, hydraulic fracture and understanding induced seismicity (among others). Asperities forming along a preexisting fault resist the relative motion of the two sides of the interface and occur due to the interaction of the surface topographies. We employ a finite element model to simulate circular partial slip asperities along a nominally flat frictional interface. Shear behavior of our partial slip asperity model closely matched the theory described by Cattaneo. The asperity model was employed to simulate a small section of an experimental fault formed between two bodies of polymethyl methacrylate, which consisted of multiple asperities whose location and sizes were directly measured using a pressure sensitive film. The quasi-static shear behavior of the interface was modeled for cyclical loading conditions, and the frictional dissipation (hysteresis) was normal stress dependent. We further our understanding by synthetically modeling lognormal size distributions of asperities that were randomly distributed in space. Synthetic distributions conserved the real contact area and aspects of the size distributions from the experimental case, allowing us to compare the constitutive behaviors based solely on spacing effects. Traction-slip behavior of the experimental interface appears to be considerably affected by spatial clustering of asperities that was not present in the randomly spaced, synthetic asperity distributions. Finally, estimates of bulk interfacial shear stiffness were determined from the constitutive traction-slip behavior and were comparable to the theoretical estimates of multi-contact interfaces with non-interacting asperities.

58 GEOSCIENCES↗

IEA Wind Task 49: Reference Site Conditions for Floating Wind Arrays

The commercial-scale deployment of floating offshore wind (FOW) projects is expected to take place in a diverse range of sites that may differ significantly from existing fixed-bottom projects. FOW farms are particularly sensitive to the water depth and the meteorological and oceanographic (metocean) and geotechnical conditions at the project site due to the wave-induced system motions and loads as well as the anchoring system constraints imposed by the seafloor conditions. Uncertainty around the site conditions will permeate through all aspects of project design, leading to suboptimal and overly conservative designs, increased costs, and adversely affected performance. As FOW expands into a global industry, metocean and geotechnical conditions will increasingly vary for projects located in different geographic regions or in far-from-shore, deep-water sites. This study represents the outputs of work package 1 of International Energy Agency Wind Task 49, which focuses on the integrated design of floating wind arrays. The primary goal of this study is to establish the type of parameters and constraints required to characterize FOW array reference sites; provide a realistic and publicly available set of reference site conditions to the FOW community as a baseline set of data for individual research projects; identify and categorize any critical gaps in the existing data or methodologies required to define reference site characteristics; and inform and support the design of reference FOW arrays. A building block concept was developed for synthesizing reference sites for the design of FOW arrays. The building blocks include three classes of site conditions focusing on the techno-economic design of FOW projects: metocean conditions, seabed conditions, and coastal infrastructure. All reference site data produced and collected in this study are publicly available.

17 WIND ENERGY↗

A Review of the Mechanical Properties of Materials Used in Nb 3 Sn Magnets for Particle Accelerators

Superconducting magnets experience significant thermo-mechanical loads throughout their life cycle. These are introduced by the electro-magnetic forces during powering, but also by the prestress applied in many magnet designs. Further to this, the large thermal excursion that components of different materials experience can generate significant internal forces. The loads are also experienced by the superconducting coils, whose critical current can decrease as a consequence of the applied strain. It is then crucial to predict the overall mechanical behavior and conservatively design a magnet, avoiding failure of the mechanical components and of the superconducting coils. Finite Element Analysis (FEA) is generally used to perform these tasks, but its results rely heavily on the material properties and models used. This is in particular true for the coil composite, which is simplified to allow reasonable model sizes in full magnet models. Here we present the state-of-art knowledge of the mechanical properties of the materials mostly used in superconducting magnet construction. We review elastic and plastic properties at room and cryogenic temperature, thermal contraction, and summarize the state-of-art failure criteria for these materials. Finally, the paper summarizes the present understanding of the mechanical behavior and limits of Nb3Sn coils. For the first time, an orthotropic failure criteria is proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accelerating Improvements in the Energy Efficiency of Room Air Conditioners (RACs) in India: Potential, Cost-Benefit, and Policies (Interim Assessment)

Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by ratcheting up the 1 star level for fixed and inverter ACs to the level of today’s five star rating for inverter ACs by 2022. Bulk procurement (similar to the Domestic Efficient Lighting Program) and incentive programs can complement the accelerated ratcheting up of star levels. Similar programs can also be implemented for other types of ACs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neptune Aerocapture Systems Analysis

A Neptune Aerocapture Systems Analysis is completed to determine the feasibility, benefit and risk of an aeroshell aerocapture system for Neptune and to identify technology gaps and technology performance goals. The high fidelity systems analysis is completed by a five center NASA team and includes the following disciplines and analyses: science; mission design; aeroshell configuration screening and definition; interplanetary navigation analyses; atmosphere modeling; computational fluid dynamics for aerodynamic performance and database definition; initial stability analyses; guidance development; atmospheric flight simulation; computational fluid dynamics and radiation analyses for aeroheating environment definition; thermal protection system design, concepts and sizing; mass properties; structures; spacecraft design and packaging; and mass sensitivities. Results show that aerocapture can deliver 1.4 times more mass to Neptune orbit than an all-propulsive system for the same launch vehicle. In addition aerocapture results in a 3-4 year reduction in trip time compared to all-propulsive systems. Aerocapture is feasible and performance is adequate for the Neptune aerocapture mission. Monte Carlo simulation results show 100% successful capture for all cases including conservative assumptions on atmosphere and navigation. Enabling technologies for this mission include TPS manufacturing; and aerothermodynamic methods and validation for determining coupled 3-D convection, radiation and ablation aeroheating rates and loads, and the effects on surface recession.

Lockwood, Mary Kae↗

Testing and Analysis Validation of a Metallic Repair Applied to a PRSEUS Tension Panel

A design and analysis of a repair concept applicable to a stiffened composite panel based on the Pultruded Rod Stitched Efficient Unitized Structure was recently completed. The damage scenario considered was a midbay-to-midbay saw-cut with a severed stiffener, flange and skin. Advanced modeling techniques such as mesh-independent definition of compliant fasteners and elastic-plastic material properties for metal parts were utilized in the finite element analysis supporting the design effort. A bolted metallic repair was selected so that it could be easily applied in the operational environment. The present work describes results obtained from a tension panel test conducted to validate both the repair concept and finite element analysis techniques used in the design effort. The test proved that the proposed repair concept is capable of sustaining load levels that are higher than those resulting from the current working stress allowables. This conclusion enables upward revision of the stress allowables that had been kept at an overly-conservative level due to concerns associated with repairability of the panels. Correlation of test data with finite element analysis results is also presented and assessed.

Przekop, Adam↗

Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems, sensors, and communication technologies for demand response and load factor control applications for the residential sector. The purpose is to cover the gaps that exist in the information captured by the sensors for energy management system to be able to provide demand response and load factor control. The vision is the development of an energy management system or other controlling enterprise hardware and software that is not only able to control loads, PHEVs, and renewable generation for demand response and load factor control, but also to do so with consumer comforts in mind and in an optimal fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A fully non-linear multi-species Fokker–Planck–Landau collision operator for simulation of fusion plasma

Fusion edge plasmas can be far from thermal equilibrium and require the use of a non-linear collision operator for accurate numerical simulations. In this article, the non-linear single-species Fokker–Planck–Landau collision operator developed by Yoon and Chang (2014) [9] is generalized to include multiple particle species. The finite volume discretization used in this work naturally yields exact conservation of mass, momentum, and energy. The implementation of this new non-linear Fokker–Planck–Landau operator in the gyrokinetic particle-in-cell codes XGC1 and XGCa is described and results of a verification study are discussed. Finally, the numerical techniques that make our non-linear collision operator viable on high-performance computing systems are described, including specialized load balancing algorithms and nested OpenMP parallelization. The collision operator's good weak and strong scaling behavior are shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Appliance Commitment for Household Load Scheduling

This paper presents a novel appliance commitment algorithm that schedules thermostatically-controlled household loads based on price and consumption forecasts considering users comfort settings to meet an optimization objective such as minimum payment or maximum comfort. The formulation of an appliance commitment problem was described in the paper using an electrical water heater load as an example. The thermal dynamics of heating and coasting of the water heater load was modeled by physical models; random hot water consumption was modeled with statistical methods. The models were used to predict the appliance operation over the scheduling time horizon. User comfort was transformed to a set of linear constraints. Then, a novel linear, sequential, optimization process was used to solve the appliance commitment problem. The simulation results demonstrate that the algorithm is fast, robust, and flexible. The algorithm can be used in home/building energy-management systems to help household owners or building managers to automatically create optimal load operation schedules based on different cost and comfort settings and compare cost/benefits among schedules.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit of a Multifamily Mass Masonry Building in New England

Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Demand Flexibility in Large Office Buildings

Data is associated with Report "Efficiency and Demand Flexibility in Large Office Buildings" by Joyce McLaren, Thomas Bowen, and Chioke Harris ( https://doi.org/10.2172/1989231 ). Results are created from repos GEB_ECM_Impact_Estimator ( https://github.nlr.gov/tbowen/GEB_ECM_Impact_Estimator ). Results outline the changes in building load in large office buildings based on measures from NREL's Scout, and the impacts those changes in load have on grid-induced emissions, grid operating costs, and customer bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗