Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “code review”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Sandia National Laboratories Facilities Management and Operations Center Design Standards Manual

At Sandia National Laboratories in New Mexico (SNL/NM), the design, construction, operation, and maintenance of facilities is guided by industry standards, a graded approach, and the systematic analysis of life cycle benefits received for costs incurred. The design of the physical plant must ensure that the facilities are "fit for use," and provide conditions that effectively, efficiently, and safely support current and future mission needs. In addition, SNL/NM applies sustainable design principles, using an integrated whole-building design approach, from site planning to facility design, construction, and operation to ensure building resource efficiency and the health and productivity of occupants. The safety and health of the workforce and the public, any possible effects on the environment, and compliance with building codes take precedence over project issues, such as performance, cost, and schedule. These design standards generally apply to all disciplines on all SNL/NM projects. Architectural and engineering design must be both functional and cost-effective. Facility design must be tailored to fit its intended function, while emphasizing low-maintenance, energy-efficient, and energy-conscious design. Design facilities that can be maintained easily, with readily accessible equipment areas, low maintenance, and quality systems. To promote an orderly and efficient appearance, architectural features of new facilities must complement and enhance the existing architecture at the site. As an Architectural and Engineering (A/E) professional, you must advise the Project Manager when this approach is prohibitively expensive. You are encouraged to use professional judgment and ingenuity to produce a coordinated interdisciplinary design that is cost-effective, easily contractible or buildable, high-performing, aesthetically pleasing, and compliant with applicable building codes. Close coordination and development of civil, landscape, structural, architectural, fire protection, mechanical, electrical, telecommunications, and security features is expected to ensure compatibility with planned functional equipment and to facilitate constructability. If portions of the design are subcontracted to specialists, delivery of the finished design documents must not be considered complete until the subcontracted portions are also submitted for review. You must, along with support consultants, perform functional analyses and programming in developing design solutions. These solutions must reflect coordination of the competing functional, budgetary, and physical requirements for the project. During design phases, meetings between you and the SNL/NM Project Team to discuss and resolve design issues are required. These meetings are a normal part of the design process. For specific design-review requirements, see the project-specific Design Criteria. In addition to the design requirements described in this manual, instructive information is provided to explain the sustainable building practice goals for design, construction, operation, and maintenance of SNL/NM facilities. Please notify SNL/NM personnel of design best practices not included in this manual, so they can be incorporated in future updates. You must convey all documents describing work to the SNL/NM Project Manager in both hard copy and in an electronic format compatible with the SNL/NM-prescribed CADD and other software packages, and in accordance with a SNL/NM approved standard format. Print all hard copy versions of submitted documents (excluding drawings and renderings) double-sided when practical.

42 ENGINEERING↗

Regulatory perspective of boiling water reactor peak reactivity credit in spent fuel storage and transportation - 14592

The U.S. Nuclear Regulatory Commission (NRC) performs reviews of applications for spent nuclear fuel transportation packages and storage casks to ensure pertinent safety regulations are met. Among other acceptance criteria, these regulations require that the package be subcritical under a variety of normal, off-normal and accident conditions. Currently, all spent nuclear fuel transportation packages and storage casks assume fresh fuel (i.e., the fuel is unirradiated) in their criticality safety analyses for boiling water reactor (BWR) fuels. Reviews using this conservative assumption are less complex. The fresh fuel assumption for BWR fuel does not allow the presence of gadolinium (often called the 'fresh fuel no-Gad' assumption), an integral burnable absorber present in nearly all BWR fuel assemblies. More recently, applicants began requesting credit for the reactivity reduction due to depletion. This credit is commonly referred to as 'burnup credit' (BUC). As of today, NRC recommends that only analyses for Pressurized Water Reactor (PWR) spent fuel implement BUC. This is due to the fact there is limited directly applicable data available to benchmark codes for depletion and reactivity calculations for BWR BUC analyses, and determining the most reactive irradiation conditions is much less straightforward than for PWR BUC analyses. Similar to what was done for PWR BUC, the NRC staff and its contractors have begun identifying and prioritizing significant technical issues so that a technical basis for the allowance of BWR BUC can be developed. BWR fuel exhibits a peak in reactivity where initial gadolinium is depleted. Crediting burnup at this point is generally referred to as using a 'peak reactivity method'. This is a conservative approach and a method routinely used in BWR spent fuel pool criticality analyses. NRC is implementing a two-phased approach in investigating BWR BUC. Phase 1 investigates peak reactivity credit and Phase 2 evaluates BUC at a typical discharge exposure. This paper discusses peak reactivity credit and its history in regulatory analyses, challenges the NRC expects in reviewing an application requesting peak BWR reactivity credit for a spent fuel transportation package or storage cask, the work that is being performed by NRC contractors to address these challenges, and future work on peak reactivity credit and full BWR BUC. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Intergalactic magnetic fields and gamma-ray observations of extreme TeV blazars

The intergalactic magnetic field (IGMF) in cosmic voids can be indirectly probed through its effect on electromagnetic cascades initiated by a source of teraelectronvolt (TeV) gamma-rays, such as active galactic nuclei (AGNs). AGNs that are sufficiently luminous at TeV energies, 'extreme TeV blazars', can produce detectable levels of secondary radiation from inverse Compton scattering of the electrons in the cascade, provided that the IGMF is not too large. We review recent work in the literature that utilizes this idea to derive constraints on the IGMF for three TeV-detected blazars, 1ES 0229+200, 1ES 1218+304, and RGB J0710+591, and we also investigate four other hard-spectrum TeV blazars in the same framework. Through a recently developed, detailed, three-dimensional particle-tracking Monte Carlo code, incorporating all major effects of QED and cosmological expansion, we research the effects of major uncertainties, such as the spectral properties of the source, uncertainty in the ultraviolet and far-infrared extragalactic background light, undersampled very high energy (energy ≥100 GeV) coverage, past history of gamma-ray emission, source versus observer geometry, and the jet AGN Doppler factor. The implications of these effects on the recently reported lower limits of the IGMF are thoroughly examined to conclude that the presently available data are compatible with a zero-IGMF hypothesis.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-462: Lessons Learned From a Machine Incident Reporting System

Purpose: Linear accelerators must operate with minimal downtime. Machine incident logs are a crucial tool to meet this requirement. They providing a history of service and demonstrate whether a fix is working. This study investigates the information content of a large department linear accelerator incident log. Methods: Our department uses an electronic reporting system to provide immediate information to both key department staff and the field service department. This study examines reports for five linac logs during 2015. The report attributes for analysis include frequency, level of documentation, who solved the problem, and type of fix used. Results: Of the reports, 36% were documented as resolved. In another 25% the resolution allowed treatment to proceed although the reported problem recurred within days. In 5% only intermediate troubleshooting was documented. The remainder lacked documentation. In 60% of the reports, radiation therapists resolved the problem, often by clearing the appropriate faults or reinitializing a software or hardware service. 22% were resolved by physics and 10% by field service engineers. The remaining 8% were resolved by IT, Facilities, or resolved spontaneously. Typical fixes, in order of scope, included clearing the fault and moving on, closing and re-opening the patient session or software, cycling power to a sub-unit, recalibrating a device (e.g., optical surface imaging), and calling in Field Service (usually resolving the problem through maintenance or component replacement). Conclusion: The reports with undocumented resolution represent a missed opportunity for learning. Frequency of who resolves a problem scales with the proximity of the person’s role (therapist, physicist, or service engineer), which is inversely related to the permanence of the resolution. Review of lessons learned from machine incident logs can form the basis for guidance to radiation therapists and medical physicists to minimize equipment downtime and ensure safe operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Coreii - Scout

COREII Scout employs React, Vite, TypeScript, Tailwind, and Daisy UI for its graphical user interface (GUI), offering both dark and light modes. The code is modular, with components and reusable wrappers to enhance efficiency. The primary goal of COREII Scout is to aid analysts in collecting and analyzing various sources related to cyber attacks, utilizing models to automate the report writing process. It uses Named Entity Recognition (NER), a type of Natural Language Processing (NLP), to extract key entities from each source. Analysts review and classify these entities using the COREII Attack Chain Estimator (ACE), adding their comments. Ultimately, a Large Language Model (LLM) generates a detailed report with user guidance. This setup ensures a streamlined and effective approach to cyber attack analysis and reporting.

Pluth, Adam [Idaho National Laboratory (INL), Idah↗

The Argonne Leadership Computing Facility 2010 annual report.

Researchers found more ways than ever to conduct transformative science at the Argonne Leadership Computing Facility (ALCF) in 2010. Both familiar initiatives and innovative new programs at the ALCF are now serving a growing, global user community with a wide range of computing needs. The Department of Energy's (DOE) INCITE Program remained vital in providing scientists with major allocations of leadership-class computing resources at the ALCF. For calendar year 2011, 35 projects were awarded 732 million supercomputer processor-hours for computationally intensive, large-scale research projects with the potential to significantly advance key areas in science and engineering. Argonne also continued to provide Director's Discretionary allocations - 'start up' awards - for potential future INCITE projects. And DOE's new ASCR Leadership Computing (ALCC) Program allocated resources to 10 ALCF projects, with an emphasis on high-risk, high-payoff simulations directly related to the Department's energy mission, national emergencies, or for broadening the research community capable of using leadership computing resources. While delivering more science today, we've also been laying a solid foundation for high performance computing in the future. After a successful DOE Lehman review, a contract was signed to deliver Mira, the next-generation Blue Gene/Q system, to the ALCF in 2012. The ALCF is working with the 16 projects that were selected for the Early Science Program (ESP) to enable them to be productive as soon as Mira is operational. Preproduction access to Mira will enable ESP projects to adapt their codes to its architecture and collaborate with ALCF staff in shaking down the new system. We expect the 10-petaflops system to stoke economic growth and improve U.S. competitiveness in key areas such as advancing clean energy and addressing global climate change. Ultimately, we envision Mira as a stepping-stone to exascale-class computers that will be faster than petascale-class computers by a factor of a thousand. Pete Beckman, who served as the ALCF's Director for the past few years, has been named director of the newly created Exascale Technology and Computing Institute (ETCi). The institute will focus on developing exascale computing to extend scientific discovery and solve critical science and engineering problems. Just as Pete's leadership propelled the ALCF to great success, we know that that ETCi will benefit immensely from his expertise and experience. Without question, the future of supercomputing is certainly in good hands. I would like to thank Pete for all his effort over the past two years, during which he oversaw the establishing of ALCF2, the deployment of the Magellan project, increases in utilization, availability, and number of projects using ALCF1. He managed the rapid growth of ALCF staff and made the facility what it is today. All the staff and users are better for Pete's efforts.

54 ENVIRONMENTAL SCIENCES↗

Qualification of Digitized Legacy Fast Reactor Data

The Integral Fast Reactor (IFR) fuel compatibility test program (1984-1994) included a variety of fuel pin examinations conducted at the Hot Fuel Examination Facility (HFEF) and the Alpha-Gamma Hot Cell Facility (AGHCF). Hard copy data records of these examinations have been recovered, scanned, and preserved in PDF format. Many hard copy records are now qualified in accordance with an NRC-approved Quality Assurance Program Plan (QAPP), and there is an ongoing effort to qualify additional legacy records. This legacy fuel performance data is vital to support design and licensing of fast reactors with validation of state-of-the-art codes and advanced methods for design and analysis. Stakeholders can most easily utilize this data when the PDF scans have been converted into digital data tables. However, qualification of the scanned hard copy data does not qualify the digital data file resulting from the digitization of the data contained in the record; the subject matter expert (SME) must make a review of the digitized data table as well before it can be designated as qualified. This report outlines a peer review process to qualify the digital data file(s), typically in CSV format, corresponding to hard copy records in accordance with the existing QAPP.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Independent Analyses of Antares R1 Core Design

This report summarizes the reactor analysis work performed by Oak Ridge National Laboratory (ORNL) for Antares Nuclear Incorporated's R1 Mark-1 heat pipe reactor design. The work was performed under a collaboration through the Department of Energy GAIN Nuclear Energy Voucher program. The purpose of this work is to perform an independent reactor analysis of the Antares reactor design and, where possible, compare ORNL's results with the results obtained by Antares. The overarching goal is to provide Antares with an independent review and calculation of their design, thereby contributing to Antares' mission to further their reactor design concept. A report with all ORNL technical results and proprietary details was provided to Antares Nuclear Incorporated separately; the present report provides a summary of the work completed, and all proprietary information is omitted. The independent reactor analysis was performed using both the SCALE code system for neutronics analysis and Flownex for thermal hydraulics analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Creep-Fatigue Damage Based on Simplified Model Test Approach

Current methods used in the ASME Code, Subsection NH for the evaluation of creep-fatigue damage are based on the separation of elevated temperature cyclic damage into two parts, creep damage and fatigue damage. This presents difficulties in both evaluation of test data and determination of cyclic damage in design. To avoid these difficulties, an alternative approach was identified, called the Simplified Model Test or SMT approach based on the use of creep-fatigue hold time test data from test specimens with elastic follow-up conservatively designed to bound the response of general structural components of interest. A key feature of the methodology is the use of the results of elastic analysis directly in design evaluation similar to current methods in the ASME Code, Subsection NB. Although originally developed for current material included in Subsection NH, recent interest in the application of Alloy 617 for components operating at very high temperatures has caused renewed interest in the SMT approach because it provides an alternative to the proposed restriction on the use of current Subsection NH simplified methods at very high temperatures. A comprehensive review and assessment of five representative simplified methods for creep-fatigue damage evaluation is presented in Asayama [1]. In this review the SMT methodology was identified as the best long term approach but the need for test data precluded its near term implementation. Asayama and Jetter [2] is a summary of the more comprehensive report by Asayama [1] with a summary of the SMT approach presented by Jetter [3].

Wang, Yanli↗

Perfect and imperfect views of ultraconserved sequences

Across the human genome, there are nearly 500 'ultraconserved' elements: regions of at least 200 contiguous nucleotides that are perfectly conserved in both the mouse and rat genomes. Remarkably, the majority of these sequences are non-coding, and many can function as enhancers that activate tissue-specific gene expression during embryonic development. From their first description more than 15 years ago, their extreme conservation has both fascinated and perplexed researchers in genomics and evolutionary biology. The intrigue around ultraconserved elements only grew with the observation that they are dispensable for viability. Here, in this paper, we review recent progress towards understanding the general importance and the specific functions of ultraconserved sequences in mammalian development and human disease and discuss possible explanations for their extreme conservation.

59 BASIC BIOLOGICAL SCIENCES↗

ALLOY SELECTION AND C-276 CODE DESIGN VALUE EXTENSION FOR ADVANCED MOLTEN SALT TECHNOLOGY TEST FACILITIES EXPERIMENTATION

Molten halide salts are being considered as working fluids for nuclear and concentrated solar power applications. High temperature molten fluoride and chloride salts are known to preferentially attack and deplete Cr in alloys, which leads to the use of high-Ni lower-Cr alloys in test facilities for advanced Molten Salt Technology. Alloys 600 and C-276 are two commercially available Ni alloys that have moderate Cr contents and are qualified to the maximum temperature of 649°C and 677°C (1,200°F and 1,251°F), respectively, in the Boiler and Pressure Vessel Code. Both alloys have good corrosion resistance to acids, are resistant to stress-corrosion cracking, and have long track records of use in the chemical industry. Comparatively, Alloy C-276 has a similar Cr content but much higher allowable stresses for temperatures greater than 600°C (1,112°F). Therefore, it has been considered as a structural material for test facilities that require operations at 700°C (1,292°F) or greater to develop high-temperature Molten Salt Technology. To meet the requirements, the current code design values were extended based on some experimental data. Analysis showed that above current Codified maximum temperature, strength of the alloy is mainly controlled by creep rupture life under the average stress, although the Sc creep rate criterion is close to the Favg.Savg rupture criterion. This paper presents the intended test facilities and the design requirements, alloy selection considerations, literature review, data analysis, and proposed allowable stress extension based on some creep test data for C-276 at temperatures greater than 677°C (1,251°F). Further research activities are also briefly mentioned.

Ren, Weiju↗

FLOP for FLAG Output Plotting

The Los Alamos hydrodynamics code, FLAG, is capable of dumping many types of output for many different variables in an array of formats. While some outputs are best viewed in a multidimensional engineering analysis visualization software, others are best viewed as 1-D “this versus that” curves. During development of a FLAG model, it is frequently required to quickly assess a model’s performance by reviewing such curves, and doing so may involve writing scripts repeatedly, adapting them each time to a specific model’s parameters. This report describes an application developed specifically to improve user efficiency in reviewing 1-D curve dumps from FLAG.

42 ENGINEERING↗

Prediction of number of breached rods following a LBLOCA of Candu plants using a BEPU approach

Radioactive doses following design basis accidents (DBA) have been important safety criteria of Candu nuclear power plant and they have been predicted in terms of the number of breached fuel rods. To support the licensing review on this concern, an analysis of LBLOCA has been conducted by using the BEPU method of KINS, KINS-REM. Number of Breached Rods (NBR) following a LBLOCA was predicted at 95 percentile probabilistic upper level in 95 percentile confidence level. Peak Cladding Temperatures (PCT) of the 84 bundles in the core pass 4 were calculated from the 124 MARS code runs in which the uncertainties of 10 major parameters including fuel thermal conductivity and break flow model were implemented. The fuel rod breaching criteria, PCT>1477 K, was used to determine the NBR 95/95. From the calculation, the predicted NBR 95/95 was 1591 rods and the calculated maximum NBR was lower than 2000 rods. Through the further improvements in feedback of the channel power behavior to thermalhydraulic calculation and in channel group modeling, NBR in more reliable level can be expected. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Occupational Radiation Exposure Report for Calendar Year 2023

The U.S. Department of Energy Occupational Radiation Exposure Report for Calendar 2023 presents the results of analyses of occupational radiation exposures at the U.S. Department of Energy (DOE), including the National Nuclear Security Administration (NNSA) operations, during calendar year 2023. This report includes occupational radiation exposure data for over 80,000 DOE Federal employees, contractors, and subcontractors as well as members of the public who have worked in or entered controlled areas monitored for exposure to radiation. DOE publishes this annual report to provide DOE Management, Program Offices, workers, health physicists, and other stakeholders an evaluation of DOE-wide performance regarding compliance with Title 10 of the Code of Federal Regulations (CFR) Part 835, Occupational Radiation Protection (10 CFR 835) radiation exposure limits and adherence to as low as reasonably achievable principles. This report provides a discussion regarding radiation protection and exposure reporting requirements. It also includes calendar year (CY) 2023 information and analyses regarding aggregate, individual, site, DOE Program, transient individuals’ dose, as well as a historical review of DOE exposure data. DOE continues to be diligent in protecting its workers and the public from exposure to radiation from DOE operations as illustrated by the results contained in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

Agent review phase one report.

This report summarizes the findings for phase one of the agent review and discusses the review methods and results. The phase one review identified a short list of agent systems that would prove most useful in the service architecture of an information management, analysis, and retrieval system. Reviewers evaluated open-source and commercial multi-agent systems and scored them based upon viability, uniqueness, ease of development, ease of deployment, and ease of integration with other products. Based on these criteria, reviewers identified the ten most appropriate systems. The report also mentions several systems that reviewers deemed noteworthy for the ideas they implement, even if those systems are not the best choices for information management purposes.

99 GENERAL AND MISCELLANEOUS↗