Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Filament extension atomizers: A study of integration potential into spray dryers for high-viscosity and non-Newtonian fluids

Filament extension atomizers (FEAs) are an emerging class of spray nozzles designed to atomize high-viscosity and non-Newtonian fluids that are challenging for conventional pressure or two-fluid nozzles. In this study, we investigate the influence of roller geometry, surface velocity, roller material, and fluid rheology on the atomization performance of FEA systems using concentrated whey protein suspensions (50–70 wt. %). Extensional and shear rheology experiments, along with high-speed imaging and particle image velocimetry, reveal that filament breakup dynamics are governed by competition between inertial, capillary, and viscoelastic stresses. High roller rotational velocity leads to narrower spray cones, contradicting rheology experiments and suggests a significant inertial contribution to filament breakup. Smaller rollers operating at the same rotational velocity led to broader spray cones consistent with expectations. An FEA nozzle was integrated into a conventional dryer producing particles in the 100 μm range. Results suggest that FEA technology enables atomization of highly viscous fluids at industrially relevant spray cone angles similar to those generated by pressure nozzles, offering a pathway to improve energy efficiency in spray drying by enabling higher solids loading feedstocks. Furthermore, these insights provide critical guidance for optimizing FEA nozzle designs and process parameters across a range of applications.

Energy efficiency↗

Laser speckle contrast imaging of blood microcirculation in pancreatic tissues during laparoscopic interventions

Laser speckle contrast imaging of the microcirculatory bed of the pancreas is performed, which allows its condition to be assessed and thereby is an additional valuable tool for making a diagnostic decision and dynamically monitoring the effectiveness of the treatment for pathology of the abdominal organs. Laparoscopic operations on the pancreas are low-traumatic and in most cases avoid open surgical interventions. For the first time an experimental system for recording speckle images, combined with a commercially available five-millimetre rigid laparoscope, is presented. The sensitivity of the system to the fluid motion in a capillary at different velocities is determined, and the possibility of finding areas of blood microcirculation disturbance in modelling pancreatic ischemia in an experiment on laboratory animals is revealed. The laparoscope illumination channel is verified by comparison with speckle dynamics under external illumination of the studied object. (paper)

60 APPLIED LIFE SCIENCES↗

Hanging droplets from liquid surfaces

Natural and man-made robotic systems use the interfacial tension between two fluids to support dense objects on liquid surfaces. Here, we show that coacervate-encased droplets of an aqueous polymer solution can be hung from the surface of a less dense aqueous polymer solution using surface tension. The forces acting on and the shapes of the hanging droplets can be controlled. Sacs with homogeneous and heterogeneous surfaces are hung from the surface and, by capillary forces, form well-ordered arrays. Locomotion and rotation can be achieved by embedding magnetic microparticles within the assemblies. Direct contact of the droplet with air enables in situ manipulation and compartmentalized cascading chemical reactions with selective transport. Applications including functional microreactors, motors, and biomimetic robots are evident.

36 MATERIALS SCIENCE↗

Ultrafast two-photon fluorescence imaging of cerebral blood circulation in the mouse brain in vivo

Characterizing blood flow dynamics in vivo is critical to understanding the function of the vascular network under physiological and pathological conditions. Existing methods for hemodynamic imaging have insufficient spatial and temporal resolution to monitor blood flow at the cellular level in large blood vessels. By using an ultrafast line-scanning module based on free-space angular chirped enhanced delay, we achieved two-photon fluorescence imaging of cortical blood flow at 1,000 two-dimensional (2D) frames and 1,000,000 one-dimensional line scans per second in the awake mouse. This orders-of-magnitude increase in temporal resolution allowed us to measure cerebral blood flow at up to 49 mm/s and observe pulsatile blood flow at harmonics of heart rate. Directly visualizing red blood cell (RBC) flow through vessels down to >800 µm in depth, we characterized cortical layer–dependent flow velocity distributions of capillaries, obtained radial velocity profiles and kilohertz 2D velocity mapping of multifile blood flow, and performed RBC flux measurements from penetrating blood vessels.

59 BASIC BIOLOGICAL SCIENCES↗

Reconfiguration of an Electrothermal-Arc Plasma Source for In Situ PMI Studies

An electrothermal-arc plasma source (ET-Arc) has been developed to produce transient plasma heat and particle fluxes similar to those produced by edge localized modes onto divertor plasma-facing components in tokamaks. The ET-Arc utilizes a capacitive discharge to send current through a 4-mm-diameter, 9-cm-long capillary source liner. The liner material is ablated to form a high-velocity plasma jet that impacts the target downstream. With the current discharge circuit configuration, pulse lengths are 1 to 2 ms in duration and deliver heat fluxes of 0.25 to 2.1 GW m-2. The plasma was previously characterized with optical emission spectroscopy (OES) on helium emission lines. The He I line ratios were interpreted with collisional radiative analysis to calculate ne and Te. The electron temperature and electron density ranged from Te = 1 to 5 eV and ne = 1022 to 1028 electrons/m3, respectively.

Lindquist, Elizabeth G.↗

Quantification of Changes in Fill Tube Curvature During Target Assembly

National Ignition Facility (NIF) targets used for inertial confinement fusion (ICF) experiments are precision-engineered assemblies composed of more than 100 components carefully and precisely assembled with accuracies no larger than a few micrometers in most cases. When individual components deviate from these strict specifications during the assembly process, they can induce target failure. An integral component essential to ICF targets is the capsule-fill-tube assembly. This assembly involves bonding the capsule to a fused silica tube less than 5 μm in thickness, through which the tritium and deuterium (T 2 + D 2 ) fuel mixture is injected into the capsule prior to the NIF shot. The filling tube is bonded to a larger fused silica capillary, about 130 μm in outer diameter, which is coated with a polymeric layer on the order of a 10-μm thickness or less. Only tubes exhibiting a deflection equivalent to less than 1% of their total length from a perfectly straight line are suitable for assembly. Slight curvatures on the order of 1 mm over 10 cm can induce unwanted stresses, potentially causing capsule misalignment and resulting in clogging or leaks during the filling process. Despite manually qualitatively sorting each tube for straightness prior assembly, it has been found that the treatments the tubes undergo once attached to the capsule can alter their curvature. Filling tubes that initially satisfy straightness tolerances can undergo geometric deformation, resulting in curvature deviations exceeding 1% of their total length and thus failing to meet target assembly requirements. Here, in this study, we propose a metric to assess the degree of curvature of the filling tubes and to gauge their changes in curvature caused by the standard thermal processing methods employed in target assembly. In addition, we suggest alternatives to mitigate tube curvature, ensuring they conform to specifications following assembly in the final targets.

Materials science↗

Initial Assessment of 3D-Printed Molybdenum Lattices as a Substrate for Liquid Metal Plasma-Facing Components

Many liquid metal plasma-facing component concepts for fusion reactors require a capillary porous material to wick the liquid metal to the surface of the component. In this work, samples of 3D-printed molybdenum lattices designed to have pore sizes ranging from 100 to 1000 µm were fabricated by two different suppliers. The dimensions of the lattice structures were characterized using an optical microscope, revealing that the lattice walls were almost systematically thicker than they were designed to be and in turn the pores are all smaller than they were designed to be. In many cases the pores were completely clogged. Several spectroscopic techniques were used to characterize the chemical composition of the materials, collectively indicating the presence of a thick layer of oxygen-rich material extending more than 1 µm below the surface. Compression testing revealed significant asymmetry in the mechanical behavior depending on which direction the force was applied relative to the print direction. Lastly, lithium wetting tests of several lattice samples were performed, and a sample with ~250-µm pores was found to soak up lithium quickly after initial wetting of the surface occurred. The implications of these results for future liquid metal plasma-facing component design are discussed.

Parsons, Matthew S. [Princeton Plasma Physics Labo↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

Surface deformation coupled with self-organized pattern on a liquid anode of 1 atm DC glow discharge

Intricate, self-organized plasma structures observed above the surface of a liquid anode of atmospheric DC glow discharge were found to give rise to coherent, organized surface deformation and mechanical wave formation at the plasma–liquid interface. This new phenomenon indicates that the liquid is closely coupled to the plasma by the anode sheath’s electrohydrodynamic (EHD) force. A scientific question then arises: Do surface perturbations, coupled with the nonuniform surface charge distribution, enhance the electric field and induce self-organization? Using the reflective background-oriented schlieren technique, the liquid surface profile under the plasma pattern was measured for the first time. The results show that surface distortions are driven by the repulsive Coulomb force of nonuniform net-negative surface charge acted by the anode sheath field. The impacts of various operating parameters on the patterns and surface waves were examined, revealing the significance of gas heating and liquid charge relaxation time in the pattern formation mechanism. Time-resolved dynamics of a pulsed DC discharge indicated that the surface deformation only appeared after the establishment of plasma patterns. Statistically, the surface wave under the plasma has high wave numbers (8000–16000 m −1 ) and small amplitudes ($<$ 10 µm), generally found in the capillary wave regime. Yet the motion of surface deformations is in tandem with the plasma pattern and exhibits a nondispersive nature of constant phase velocity (0.1–0.4 m s −1 ), suggesting the dominant role of EHD force over the surface tension in the observed surface wave. These results indicate that the deformed liquid surface is driven by the EHD force of the plasma sheath. Although they share a similar geometry, the deformation and wave dynamics of the liquid surface do not stimulate a plasma pattern. Importantly, the complex EHD coupling in the plasma–liquid system raises awareness and new challenges for plasma control engineering, and the quantitative characteristics of the nondispersive surface wave are informative for advancing relevant theory and modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the TJ-II stellarator research programme towards model validation in fusion plasmas

TJ-II stellarator results on modelling and validation of plasma flow asymmetries due to on-surface potential variations, plasma fuelling physics, Alfvén eigenmodes (AEs) control and stability, the interplay between turbulence and neoclassical (NC) mechanisms and liquid metals are reported. Regarding the validation of the neoclassically predicted potential asymmetries, its impact on the radial electric field along the flux surface has been successfully validated against Doppler reflectometry measurements. Research on the physics and modelling of plasma core fuelling with pellets and tracer encapsulated solid pellet injection has shown that, although post-injection particle radial redistributions can be understood qualitatively from NC mechanisms, turbulence and fluctuations are strongly affected during the ablation process. Advanced analysis tools based on transfer entropy have shown that radial electric fields do not only affect the radial turbulence correlation length but are also capable of reducing the propagation of turbulence from the edge into the scrape-off layer. Direct experimental observation of long range correlated structures show that zonal flow structures are ubiquitous in the whole plasma cross-section in the TJ-II stellarator. Alfvénic activity control strategies using ECRH and ECCD as well as the relation between zonal structures and AEs are reported. Finally, the behaviour of liquid metals exposed to hot and cold plasmas in a capillary porous system container was investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of lithium vapor box divertor evaporator location on NSTX-U using SOLPS-ITER

Commercial fusion reactors will be faced with extremely high divertor target heat fluxes that will require mitigation. Simulations of detachment in an NSTX-U scenario projected to have 92 MW/m 2 unmitigated peak target heat flux are presented, which reaches sub-10 MW/m 2 target heat flux using a highly dissipating lithium vapor box divertor design. The lithium vapor box is a detached divertor design which employs lithium vapor evaporation and condensation to contain lithium below the X-point. Previous SOLPS modeling has indicated a lithium vapor box can reduce the heat flux down to 10 MW/m 2 via simultaneous evaporation from the Private Flux Region (PFR) and the Common Flux Region (CFR) sides of the vapor box. It is found here that PFR evaporation has improved access to the separatrix leading to significantly more efficient power dissipation than CFR evaporation. Simulations of target evaporation with an evaporation distribution that is self-consistent with the temperature of a Capillary Porous System with Fast flowing liquid lithium (CPSF) could reach n Li / n e ~ 0.025-0.030 at the Last Closed Flux Surface (LCFS) depending on the liquid metal flow speeds and lithium sputtering yield, while PFR-side evaporation can reach acceptable heat fluxes with n Li / n e ~ 0.038 at the LCFS. However, PFR evaporator performance can be improved if the target is allowed to be hot enough such that it reflects lithium, reaching n Li / n e ~ 0.028 and reducing required lithium evaporation. Ultimately PFR evaporation and target evaporation are found to have similar ability to produce acceptable heat flux solutions with minimal upstream concentration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

An alternative electrode design for accurate spectral induced polarization measurements in variably saturated porous media

SUMMARY Applications of spectral induced polarization (SIP) require electrodes that maintain hydrologic contact with surrounding soils to capture small electrical responses, often observed as phase shifts in milliradians. For unsaturated soils, electrodes must overcome increased electrical contact impedance due to reduced pore fluid. Traditional designs use a ceramic membrane electrode (CME) with a water reservoir and metal conductor, requiring periodic maintenance to retain electrolytic solution. For field applications where maintenance is impractical, alternative designs are needed. This study evaluated a new electrode design (silica flour electrode, SFE) alongside a CME. SFEs use packed silica flour to store water via capillary forces against a metal conductor. This study examined both designs in three variably saturated soils at soil suctions up to 700 mbar and soil water contents below 1 percent, with SIP measurements across 0.01 to 10 000 Hz frequencies. SFEs match CMEs at high frequencies and perform better at lower frequencies, without requiring ongoing maintenance, making them ideal for field use. In water-only experiments, CMEs produced errors and high noise below 1.5 Hz, whereas SFEs were more accurate. However, CMEs performed better above 300 Hz. In fine sand, SFEs performed better due to the relatively lower contact impedance as compared to CMEs. Both electrode types performed comparably in silty sand and silt loam soils, although CMEs required ongoing maintenance, suggesting potential for long-term reliability issues.

58 GEOSCIENCES↗

Involvement of the Streptococcus mutans PgfE and GalE 4-epimerases in protein glycosylation, carbon metabolism, and cell division

Streptococcus mutans is a key pathogen associated with dental caries and is often implicated in infective endocarditis. This organism forms robust biofilms on tooth surfaces and can use collagen-binding proteins (CBPs) to efficiently colonize collagenous substrates, including dentin and heart valves. One of the best characterized CBPs of S. mutans is Cnm, which contributes to adhesion and invasion of oral epithelial and heart endothelial cells. These virulence properties were subsequently linked to post-translational modification (PTM) of the Cnm threonine-rich repeat region by the Pgf glycosylation machinery, which consists of 4 enzymes: PgfS, PgfM1, PgfE, and PgfM2. Inactivation of the S. mutans pgf genes leads to decreased collagen binding, reduced invasion of human coronary artery endothelial cells, and attenuated virulence in the Galleria mellonella invertebrate model. The present study aimed to better understand Cnm glycosylation and characterize the predicted 4-epimerase, PgfE. Using a truncated Cnm variant containing only 2 threonine-rich repeats, mass spectrometric analysis revealed extensive glycosylation with HexNAc2. Compositional analysis, complemented with lectin blotting, identified the HexNAc2 moieties as GlcNAc and GalNAc. Comparison of PgfE with the other S. mutans 4-epimerase GalE through structural modeling, nuclear magnetic resonance, and capillary electrophoresis demonstrated that GalE is a UDP-Glc-4-epimerase, while PgfE is a GlcNAc-4-epimerase. While PgfE exclusively participates in protein O-glycosylation, we found that GalE affects galactose metabolism and cell division. Furthermore, this study further emphasizes the importance of O-linked protein glycosylation and carbohydrate metabolism in S. mutans and identifies the PTM modifications of the key CBP, Cnm.

4-epimerases↗

1000 Wh L−1 lithium-ion batteries enabled by crosslink-shrunk tough carbon encapsulated silicon microparticle anodes

Abstract Microparticulate silicon (Si), normally shelled with carbons, features higher tap density and less interfacial side reactions compared to its nanosized counterpart, showing great potential to be applied as high-energy lithium-ion battery anodes. However, localized high stress generated during fabrication and particularly, under operating, could induce cracking of carbon shells and release pulverized nanoparticles, significantly deteriorating its electrochemical performance. Here we design a strong yet ductile carbon cage from an easily processing capillary shrinkage of graphene hydrogel followed by precise tailoring of inner voids. Such a structure, analog to the stable structure of plant cells, presents ‘imperfection-tolerance’ to volume variation of irregular Si microparticles, maintaining the electrode integrity over 1000 cycles with Coulombic efficiency over 99.5%. This design enables the use of a dense and thick (3 mAh cm–2) microparticulate Si anode with an ultra-high volumetric energy density of 1048 Wh L–1 achieved at pouch full-cell level coupled with a LiNi0.8Co0.1Mn0.1O2 cathode.

25 ENERGY STORAGE↗

Spatially quasi-periodic water waves of finite depth

We present a numerical study of spatially quasi-periodic gravity-capillary waves of finite depth in both the initial value problem and travelling wave settings. We adopt a quasi-periodic conformal mapping formulation of the Euler equations, where one-dimensional quasi-periodic functions are represented by periodic functions on a higher-dimensional torus. We compute the time evolution of free surface waves in the presence of a background flow and a quasi-periodic bottom boundary and observe the formation of quasi-periodic patterns on the free surface. Two types of quasi-periodic travelling waves are computed: small-amplitude waves bifurcating from the zero-amplitude solution and larger-amplitude waves bifurcating from finite-amplitude periodic travelling waves. We derive weakly nonlinear approximations of the first type and investigate the associated small-divisor problem. We find that waves of the second type exhibit striking nonlinear behaviour, e.g. the peaks and troughs are shifted non-periodically from the corresponding periodic waves due to the activation of quasi-periodic modes.

Science & Technology - Other Topics↗

Geometrical-Based Generative Adversarial Network to Enhance Digital Rock Image Quality

X-ray microcomputed tomography (micro-CT) is a common tool for the study of porous media structures and properties. High-quality micro-CT data are required to accurately capture pore structures. Acquiring high-quality micro-CT data, however, is not always possible, owing to application limitations and experimental constraints. Therefore, we propose a geometrical-based generative adversarial network (GAN) to rapidly restore noisy micro-CT images to their clean counterparts. The training data and related ground-truth (GT) data are scanned for 7 min and 9.5 h, respectively. To evaluate the performance of the geometrical-based GAN, a 6003 voxel image that has never been used for training is reconstructed and compared with the corresponding GT image. Histogram matching and linear normalization are implemented to adjust the histogram of the reconstructed image to that of the GT image. A watershed-based segmentation method is then applied to delineate pore and solid phases. Lastly, we measure the Minkowski functionals and petrophysical properties, including absolute permeability, pore size distribution, drainage capillary pressure-saturation curve, and imbibition relative permeability, to estimate the physical accuracy of the denoised image. The results show that the proposed geometrical-based GAN can accurately restore noisy micro-CT data. By reducing the scanning time from 9.5 h to 7 min, the expenditure of collecting micro-CT can be decreased significantly. This is particularly important for applications where time-lapse images of a dynamic process are required, high-throughput imaging is necessary for real-time data analysis, or where the quantification of large sample volumes is required.