Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Development and Validation of a Two-Phase Thermal-Hydraulic CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance Computational Fluid Dynamics (CFD) code NEK5000. The goal of this work is to verify and validate the two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) previously developed at Argonne but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2020. This report focuses on verification and validation of the water-steam boiling model NEK-2P Two-Phase, CFD code. The NEK-2P was validated with Nuclear Power Engineering Corporation (NUPEC) Pressurized Water Reactor (PWR) Sub-channel and Bundle Test (PSBT) void distribution benchmark. Three different simulations were performed and analyzed for various operating conditions such as wall-heat flux and sub-cooled inlet temperatures. Reasonably good agreement with measured data was obtained in predicting the measured void distributions. Simulations were performed for Virginia Tech. (VT) 3x3 rod bundle geometry with and without spacers. The preliminary results were presented for Simplified Spacer Grid (SSG). In addition, the implementation of interface reconstruction model was tested with one of the Becker benchmark Critical Heat Flux (CHF) experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Formation and Growth of Micro and Macro Bubbles on Copper-Graphite Composite Surfaces

Micro scale boiling behavior in the vicinity of graphite micro-fiber tips on the coppergraphite composite boiling surfaces is investigated. It is discovered that a large number of micro bubbles are formed first at the micro scratches and cavities on the copper matrix in pool boiling. In virtue of the non-wetting property of graphite, once the growing micro bubbles touch the graphite tips, the micro bubbles are sucked by the tips and merged into larger micro bubbles sitting on the tips. The micro bubbles grow rapidly and coalesce to form macro bubbles, each of which sitting on several tips. The growth processes of the micro and macro bubbles are analyzed and formulated followed by an analysis of bubble departure on the composite surfaces. Based on these analyses, the enhancement mechanism of the pool boiling heat transfer on the composite surfaces is clearly revealed. Experimental results of pool boiling heat transfer both for water and Freon-113 on the composite surfaces convincingly demonstrate the enhancement effects of the unique structure of Cu-Gr composite surfaces on boiling heat transfer.

Chao, David F.↗

Universal Two-Phase Convection Heat Transfer Correlations for Cryogenic Pipe Chilldown

This paper presents a set of universal two-phase convection heat transfer correlations for modeling boiling heat transfer during pipe chilldown fit over the widest available range of cryogenic fluids and thermodynamic conditions. The correlations improve upon prior correlations that were developed separately for liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching datasets. The new correlations include equations to calculate the single-phase vapor heat transfer, film boiling heat transfer, transition boiling heat transfer, nucleate boiling heat transfer, single-phase liquid heat transfer, bulk vapor temperature during high quality film boiling, Leidenfrost temperature, critical heat flux, critical heat flux temperature, and the onset of nucleate boiling temperature. The correlations were validated against LH2, LN2, liquid methane, liquid oxygen, and liquid argon pipe quenching datasets. The eight datasets cover the following parameter ranges: pipe lengths of 0.1 to 6.5m; outer pipe diameters of 12.7 to 25.4 mm; pipe wall thicknesses from 0.51 to 1.64 mm; flow directions of upward, downward, and horizontal; gravity levels of 1g and 0g±0.01g. A numerical model assumes homogeneous mixing between the vapor and liquid and implicitly integrates the coupled energy equations for the pipe and fluid, as well as continuity for the fluid. The model was used to estimate the equilibrium quality and fluid mass accumulation along the pipes during chilldown from estimates of the fluid-pipe heat transfer extracted from temperature measurements. The correlations can be implemented in lumped parameter codes such as SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP) to improve the accuracy of chilldown time and chilldown boiloff mass predictions. Such predictions are useful for designing ground or in-space cryogenic liquid transfer systems.

Universal Correlations↗

Vertical Gradients in Fluidized Sand Columns

This study evaluated the influence of diameter and grain size on the initiation and continuation phase of piping erosion. Twelve tests were performed in a laboratory setting in which sand was fluidized in a controlled setting and hydraulic gradients within the sand, flow rates through the sand, and expansion of the sand columns were measured as the sand was fluidized. This study was conducted to improve the understanding of the resistance a vertical column of sand offers to piping erosion. From the fluidization tests conducted in two permeameters with different diameters, it cannot be concluded that permeameter diameter has a significant influence on a specimen’s resistance to piping erosion. Although one test conducted in the smaller diameter permeameter did record hydraulic gradients lower than those recorded in tests conducted in the larger diameter permeameter, this was not a consistent observation for all tests run in the smaller diameter permeameter. Further analysis ought to involve more tests run in each permeameter as well as incorporating additional permeameters with both larger and smaller diameters than those used in this study. From the fluidization tests conducted using the well-graded, coarse-, medium-, and fine-grained sands, it appears that resistance to piping is dependent on grain size and grain size distribution. The coarse-grained sand offered the most resistance to piping, the fine-grained sand offered the least, and the medium-grained and well-graded sands offered similar resistances between those of the coarse-grained and fine-grained sands. Gradients at which sand boils were observed, maximum gradients reached before the sand fluidized, and the minimum gradients reached at the conclusion of each test also appear to be influenced by grain size and grain size distribution. Tests conducted on the coarse-grained sand recorded the highest and most closely spaced sand boil, maximum, and minimum gradients, indicating that it offered the highest and most constant resistance to piping, while the fine-grained sand tests recorded the lowest sand boil, maximum, and minimum gradients, indicating that it offered the least resistance to piping and that resistance decreased as the tests progressed. The medium-grained sand tests recorded sand boil, maximum, and minimum gradients between those of the coarse-grained and fine-grained sands. The well-graded sand tests recorded the lowest sand boil gradient, which could be indicative of the occurrence of suffusion erosion occurring in conjunction with piping erosion, whereby the finer particles were washed out of the sand matrix at relatively low gradients, forming sand boils while the relatively coarser matrix remained resistant to piping. All tests recorded maximum gradients that were lower than the theoretical critical gradients calculated using Equation 4. This is likely due to the changes in the internal configuration of the sand as the piping process 33 initiates. In order to better understand the influence of gradation on resistance to piping, more sand gradations should be tested in future work. Measured hydraulic gradients in the lower portion of the fluidized sands were higher than those measured in higher portions. This could be explained if the density of the fluidized sand was not uniform, with more material near the base of the column than near the top, which is contrary to the findings of Sellmeijer. Furthermore, the tests were terminated when the maximum height of the upstream reservoir was reached but did not give any evidence that gradients had leveled off to a uniform “final gradient”. It is likely that gradients would have continued to dissipate had more hydraulic head been applied to the upstream reservoir. In order to better understand this, additional testing should be conducted using an upstream reservoir capable of simulating higher hydraulic heads.

13 HYDRO ENERGY↗

Two-phase computational fluid dynamics analysis of a hypervapotron heatsink for ITER first wall applications.

Enhanced radial transport in the plasma and the effect of ELMS may increase the ITER first wall heat loads to as much as 4 to 5 MW/m{sup 2} over localized areas. One proposed heatsink that can handle these higher loads is a CuCrZr hypervapotron. One concept for a first wall panel consists of 20 hypervapotron channels, 1400 mm long and 48.5 mm wide. The nominal cooling conditions anticipated for each channel are 400 g/s of water at 3 MPa and 100degC. This will result in boiling over a portion of the total length, and two-phase thermalhydraulic analysis is required to predict accurately the thermal performance. Existing heat transfer correlations used for nucleate boiling are not appropriate here, because the flow does not reach fully developed conditions in the multi-segmented channels. Our design-by-analysis approach used two commercial codes, CFdesign and Fluent, to perform computational fluid dynamics analyses with conjugate heat transfer. The Fluent simulations use the Rensselaer (RPI) model for wall heat flux partitioning to model nucleate boiling as implemented in user defined functions. A more computationally expensive volume-of-fluid (VOF) multiphase model encompassing only several hypervapotron teeth provided a check on the results. We present a comparison between the two codes for this Eulerian multi-phase problem that relies on the steam tables for the fluid properties. The analyses optimized the hypervapotron geometry including teeth height and pitch and the depth of the back channel to permit highly effective boiling heat transfer in the grooves between teeth while ensuring that no boiling could occur at the back channel exit. The analysis used a representative heat flux profile with the peak heat flux of 5 MW/m{sup 2} limited to a 50-mm-length. The surface temperature of the heatsink is kept well below 350degC. The baseline design uses 2 mm for the teeth height, a 3 mm width and 6 mm pitch, and a back channel depth of 8 mm. The teeth are detac- hed from the sidewall by a 2-mm-wide slot on both sides that aids in sweep-out and quenching of the vapor bubbles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparison of two-phase computational fluid dynamics codes applied to the ITER first wall hypervapotron.

Enhanced radial transport in the plasma and the effect of ELMS may increase the ITER first wall heat loads to as much as 4 to 5 MW/m{sup 2} over localized areas. One proposed heatsink that can handle these higher loads is a CuCrZr hypervapotron. One concept for a first wall panel consists of 20 hypervapotron channels, each measuring 1400 mm long and 48.5 mm wide. The nominal cooling conditions anticipated for each channel are 400 g/s of water at 3 MPa and 100 C. This will result in boiling over a portion of the total length. A two-phase thermalhydraulic analysis is required to predict accurately the thermal performance. Existing heat transfer correlations used for nucleate boiling are not appropriate here because the flow does not reach fully developed conditions in the multi-segmented channels. Our design-by-analysis approach used two commercial codes, Fluent and Star-CCM+, to perform computational fluid dynamics analyses with conjugate heat transfer. Both codes use the Rensselear (RPI) model for wall heat flux partitioning to model nucleate boiling as implemented in user-defined functions. We present a comparison between the two codes for this Eulerian multiphase problem that relies on temperature dependent materials properties. The analyses optimized the hypervapotron geometry, including teeth height and pitch, as well as the depth of the back channel to permit highly effective boiling heat transfer in the grooves between the teeth while ensuring that no boiling could occur at the back channel exit. The analysis used a representative heat flux profile with the peak heat flux of 5 MW/m{sup 2} limited to a 50 mm length. The maximum surface temperature of the heatsink is 415 C. The baseline design uses 2 mm for the teeth height, a 3 mm width and 6 mm pitch, and a back channel depth of 8 mm. The teeth are detached from the sidewall by a 2-mm-wide slot on both sides that aids in sweep-out and quenching of the vapor bubbles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of SiC-SiC accident tolerant fuel cladding after stress application

In this work, SiC-SiC tubes with representative LWR (water cooled reactor) cladding dimensions were subjected to cycles of out-of-pile thermal stress followed by quenching. Samples were held at elevated temperatures and dropped into a water bath to replicate the high thermal stresses generated during reflooding. The samples were then characterized to measure changes in strength, permeability, and structure. Results were evaluated both for quenching into room temperature and boiling water. The results show that SiC-SiC composite tubes quenched from 1000 Celsius degrees in air into a boiling water bath exhibited no increase in He leak rate through the cylinder wall up to a pressure difference of 34.5 kPa compared to the as-fabricated state. SiC-SiC composite tubes quenched from 300-400 C. degrees into room temperature water showed an increase in He leak rate compared to the as-fabricated state. We attribute this to the more severe thermal gradient generated through the wall thickness due to higher heat flux characteristic of nucleate boiling compared to film boiling. A persistent vapor film forms around the samples quenched into boiling water, whereas no vapor film forms for the samples quenched into room temperature water. Another important result is that not loss in strength was noted compared to unquenched samples and that the stresses generated by the quenching were not enough to cause fiber fracture.

36 MATERIALS SCIENCE↗

A novel probe design to study wetting front kinematics during forced convective quenching

The kinematics of the wetting front, i.e., the loci of the boundary between stable vapor film and the presence of bubbles, during quenching operations largely determines the evolution of the microstructural and displacement fields which, in turn, control the properties of the quenched product. Thus, it is important to develop techniques that allow its precise characterization. To this end, a novel probe design (conical-end cylinder) was coupled with an experimental set-up that guarantees fully developed flow to study wetting front kinematics during forced convective quenching of AISI 304 stainless steel probes in water at 60 C, flowing at 0.20 and 0.60 m/s. Conventional probes (flat-end cylinder) were also quenched for comparison. The wetting front was not symmetric when flat-end cylindrical probes were quenched, even for fully developed flow and relatively low values of quenchant velocity. Computer simulation of the vorticity field near the probe base (considering an isothermal system at ambient temperature) showed that there is a significant vorticity gradient in that region which may favour the chaotic collapse of the vapor film. In contrast, a similar calculation did not show any noticeable vorticity gradient for the conical-end cylindrical probe even at high quenchant velocities. The conical-end cylindrical probe and a fully developed flow ensured that the vapor film collapsed uniformly around the probe due to the fact that the formation of the wetting front was concentrated, initially, at the probe tip. This condition permits a constant advance of the wetting front and a stable transition between boiling regimes, facilitating the study of the kinematics of the wetting front. For the experimental conditions studied the following parameters were derived: (1) wetting front velocity, (2) nucleate boiling length, (3) duration of the nucleate boiling stage and (4) width of the vapor film. The duration of the nucleate boiling stage could be estimated using existing equations, obtaining results that are comparable to the experimentally determined values. For the experimental conditions studied the different boiling regimes and its transitions could be precisely defined along the surface heat flux history curve during quenching, resulting in six different zones. (author)

42 ENGINEERING↗

Predicting critical heat flux using localized sensing at invisible vapor-liquid interfaces

Predicting critical heat flux (CHF) in two-phase electronics cooling systems remains a significant challenge due to the sudden onset of boiling crisis and the difficulty in directly visualizing vapor-liquid interfaces. Existing sensing methods rely on lagging temperature measurements, optically accessible systems, or spatially averaged signals that cannot pinpoint CHF initiation at localized high-heat-flux regions. Here, we report a planar capacitive sensing approach that enables real-time, localized detection of vapor-liquid interface dynamics for CHF prediction in boiling heat transfer. The capacitive sensor exploits the dielectric constant difference between liquid and vapor phases to capture bubble nucleation, growth, and departure dynamics with a temporal resolution down to 2 ms. The capacitive sensing reveals distinct signals across boiling regimes: from high-frequency fluctuations during strong nucleate boiling to low-frequency fluctuations with increased amplitudes when approaching CHF. The multi-sensor array experiments demonstrate real-time localized sensing, where each sensor responds exclusively to boiling in its immediate vicinity without crosstalk from neighboring regions. This non-intrusive sensing approach provides predictive rather than lagging sensing signals of CHF occurrence, offering predictive diagnosis of two-phase liquid cooling for the thermal management of high-power-density electronics.

CHF↗

A knowledge gap analysis for transient CHF prediction within RELAP5-3D

Here we compare several experimental pool and flow boiling critical heat flux experiments with corresponding computational models developed with RELAP5-3D. Encompassed within this paper are several sensitivity analyses for the boiling heat transfer correlations, critical heat flux (CHF) prediction within RELAP5-3D and the thermal properties of the cladding for experiments in the Transient Reactor Test Loop (TRTL) and Transient Reactor Test (TREAT) facilities. The sensitivity analyses were consistent in determining that there is a large contribution from the critical heat flux multiplier which in this application, accounts for the effects of power transient critical heat flux. Comparison to experimental results of both the TREAT CHF-SERTTA experimental campaign and a University of New Mexico (UNM) pool boiling experimental campaign demonstrate both the under-prediction of transient CHF and nucleate boiling heat transfer. To address the gaps in knowledge regarding the transient heating effect for both boiling heat transfer and CHF prediction, we present an experimental test matrix for the TRTL facility that will isolate the power transient effect under PWR relevant operational conditions. The test matrix will incorporate 6 power pulses with a constant energy deposition and a timescale that spans over several orders of magnitude, including a steady state test with an exponential period of 10 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The influence of intake flow and coolant temperature on gasoline spray morphology during early-injection DISI engine operation

Multi-hole gasoline injectors operating at conditions spanning throttled early-intake stroke operation produce spray plumes that either remained separated or merge and collapse due to flash boiling. Flash boiling occurs due to the sudden expansion of gas bubbles in the liquid fuel at high fuel temperature and low ambient pressure. This study records high-speed images of spray-morphology changes due to in-cylinder flow, thereby revealing operating conditions that do and do not affect the self-induced morphology observed in quiescent vessels. Specifically, in a central-injection, four-valve, high-tumble engine, where the thermodynamic state and in-cylinder cross flow are dynamic. Motivated by cold start and hot restart operation, the fuel pressure, coolant temperature, in-cylinder air pressure, and engine rpm were systematically varied over relevant operating conditions, which bracketed the range from non- to flash-boiling sprays. The results reveal the operating conditions at which the in-cylinder cross flow disrupts the spray morphology as well as the extent of the disruption. At 650 rpm, the spray morphology was similar to that observed in quiescent vessels at nominally equivalent fuel temperature and in-cylinder pressure, indicating that the spray’s self-induced entrainment flow dominated the in-cylinder flow. However, for fuel temperature and ambient pressure near the transition between non- and flash-boiling, the intake cross flow at higher engine speed (1950 rpm) significantly disrupted the spray morphology. The high cross-flow velocity appears to induce plume merging and collapse, whereas none was evident at low rpm (650 rpm). This study led to the postulate that the spray merging and collapse are governed by the rate of atomization near the nozzle exit, presumed to be controlled by either or both aerodynamic atomization and flash-boiling intensity. It would then follow that spray modeling in CFD requires atomization models that blend the effects of both physical processes.

42 ENGINEERING↗

ASSESSMENT OF RESIDUAL STRESSES IN SRS AND HANFORD 3013 INNER AND CONVENIENCE CANS

Chloride stress corrosion cracking (SCC) is a plausible corrosion mechanism for the stainless steel 3013 containers during their lifetime for plutonium material storage if sufficient electrolyte is present within the container. Contributing factors for SCC, such as fabrication and welding residual stresses, are present in the 3013 cans. Convenience and inner cans from both Hanford and SRS are made by a flow form process, which cold works the stainless steel during fabrication. Additionally, the inner cans also are sealed at the can top with a closure weld to the sealing plug. Only SRS and Hanford were tested since moisture levels were significant for SCC. As part of the 3013 corrosion plan for FY09, testing in a boiling magnesium chloride solution was performed on actual 3013 convenience and inner cans to determine if the residual stresses were sufficient for the initiation and propagation of SCC. Additional testing in a 40% calcium chloride solution was also performed on 304L stainless steel SCC coupons, i.e. stressed teardrop-shaped samples (teardrops), and an inner can welded top to provide comparative results and to assess the effect of residual stresses in a less aggressive environment. The testing performed under this task consisted of 3013 inner and convenience cans and 304L teardrops exposed to a boiling magnesium chloride solutions per ASTM G36 and a 40% calcium chloride solution at 100 C following the guidance of ASTM G123. Cracking occurred in all can types including the inner can bottom and welded top and the bottoms of the SRS and Hanford convenience cans when exposed to the boiling magnesium chloride solution at 155 C. Cracking occurred at different times indicative of the residual stress levels in the cans. 304L teardrops cracked in the shortest time interval and therefore provide a conservative estimate for can performance. Testing in a 40% calcium chloride solution at 100 C demonstrated that cracking occurs in a less aggressive environment but at significantly longer times than in the boiling magnesium chloride. Vapor space cracking was also found to occur in the inner can welded top exposed over the boiling magnesium chloride solution and on 304L teardrops exposed over a hot calcium chloride solution.

36 MATERIALS SCIENCE↗

Optimizing the Heisenberg Vortex Tube for Hydrogen Cooling (Final Technical Report)

Hydrogen utilization at Plug Power sites ranges between 70-93% with the remainder vented and lost to the atmosphere. The goal of this project was to improve hydrogen utilization at Plug Power fulfillment centers via the patented Heisenberg vortex tube (HVT). The HVT combines conventional counterflow vortex tubes with para-orthohydrogen conversion catalyst to allow the cooling of hydrogen flows with no moving parts or external energy inputs. In year 1 of this project the HVT was evaluated to improve hydrogen utilization via the following concepts: 1) increasing liquid hydrogen pump volumetric efficiency by 20% through vapor separation and subcooling of the liquid, 2) reducing liquid hydrogen storage tank boil-off losses by 20% through thermal vapor shielding (TVS), and 3) increase isentropic efficiency of supercritical hydrogen expansion at 40-50 K, from 31% to over 40%. The TVS concept was selected as the most favorable application for further development. While the conceptual analysis was underway, the cryocatalysis hydrogen experiment facility (CHEF) was retrofitted with a new cryocooler, higher pressure condenser tanks, and in-situ fiber-optic Raman probes for ortho-parahydrogen composition analysis at the inlets and outlets of the HVT. To our knowledge this is the first in-situ implementation of cryogenic Raman probes for ortho-parahydrogen analysis. Subsequent testing of catalyzed and non-catalyzed HVT identified a low flow rate, high-conversion efficacy regime well suited for TVS development. Computational fluid dynamics (CFD), Reduced order modeling (ROM), and quantum Monte Carlo atomistic simulations were applied to optimize the design of the HVT implemented for TVS. The simulations and analysis identified a ruthenium-based catalyst as the most optimal for high conversion with little pressure losses and was matched to experimental measurements. These results indicated the design could achieve the 20% boil-off reduction target. An HVT field-trial was designed and constructed by Plug Power and implemented at a customer site. However, budget limitations reduced the amount of catalyst that could be applied to the HVT. With the reduced amount of catalyst, CFD analysis estimated about 3% reduction in boil-off. A similar amount of boil-off reduction was observed during preliminary measurements during tank commissioning. However, the results have a large margin for error and were operated at relatively low tank temperatures when the HVT has the lowest potential for improvement. This project demonstrated the use of para-orthohydrogen catalysis for reducing liquid hydrogen tank boil-off losses. The field trial system is anticipated to provide long-term experimental measurements on tank operational performance that will allow Plug Power to instrument additional tanks in the future. Recommendations for future work include the development of higher activity, lower cost para-orthohydrogen conversion catalyst for use in the HVT. Tank process optimizations could maximize the efficacy of the HVT and further improve hydrogen utilization.

08 HYDROGEN↗

A New Mechanistic Model of Nucleation Site Density

The two-fluid model, which is a macroscopic formulation of nucleate boiling systems, still makes use of experimental data or empirical correlations for closure models. The use of empirical correlations outside the range of conditions where they have been developed is questionable, which limits the application of the two-fluid model in the design of new boiling systems. This paper proposes a mechanistic model of nucleation site density, which, along with bubble departure frequency and bubble departure diameter, are key factors in the accurate prediction of evaporation heat flux and vapor generation rate on the heated surface in the two-fluid model formulation. Nucleation originates from cavities on boiling surface. Griffith and Wallis proposed that a nucleation site becomes active when vapor is entrapped inside the cavity and the mouth radius is larger than the minimum cavity size corresponding to the wall superheat. Yang and Kim obtained the probability density function of the cavity mouth radius and the half cone angle through a statistical treatment based on the measured cavities by a scanning electron microscope and a differential interference contrast microscope. Hibiki and Ishii modified the distribution profiles of the size and cone angle of cavities present on the heater surface and proposed a new model which is valid over rather wide range of flow conditions. The existing nucleation site density models are not physically consistent at onset of nucleation, where no boiling occurs even though the models predict a high nucleation site density. The new model developed in this paper took into account the non-uniform temperature in liquid near the wall, which allows one to physically impart the onset of nucleation into the nucleation site density model. The new model was parametrically tested and showed physical consistency at the region near onset of nucleate boiling. The new model was also validated against selected experimental data and good agreement was reached.

42 ENGINEERING↗

A thermally-limited bubble growth model for the relaxation time of superheated fuels

Here, we propose a novel approach to evaluate the relaxation time of vapor bubble growth in the context of the flash boiling of a superheated liquid. In alternative to the empirical correlation derived from superheated water experiments almost fifty years ago, the new model describes the thermally-dominated growth of vapor bubbles in terms that are dependent on the local Jakob number (the ratio of sensible heat to latent heat during phase change) and the number density of vapor bubbles. The model is tested by plugging the resulting relaxation time into the Homogenous Relaxation Model (HRM). Flash-boiling simulations carried out with HRM are compared with n-pentane (C 5 H 12 ) injection and boil-off experiments conducted with a real-size, axial-hole, transparent gasoline injector discharging into a constant-pressure vessel. The long-distance microscopy images from the experiments, processed to derive the projected liquid volume (PLV) of the spray, provide a unique set of time-resolved validation data for direct fuel injection simulations. At conditions ranging from flaring to mild and minimal flash boiling, we show that switching to the new relaxation time improves the agreement with the measured PLV profiles with respect to the standard empirical model. Particularly at flaring conditions, the predicted increase in gas cooling caused by rapid vapor production is shown to be more consistent with the observed boil-off.

42 ENGINEERING↗

Probes for investigating the effect of magnetic field, field orientation, temperature and strain on the critical current density of anisotropic high-temperature superconducting tapes in a split-pair 15 T horizontal magnet

We present the designs of probes for making critical current density (J{sub c}) measurements on anisotropic high-temperature superconducting tapes as a function of field, field orientation, temperature and strain in our 40 mm bore, split-pair 15 T horizontal magnet. Emphasis is placed on the design of three components: the vapour-cooled current leads, the variable temperature enclosure, and the springboard-shaped bending beam sample holder. The vapour-cooled brass critical-current leads used superconducting tapes and in operation ran hot with a duty cycle (D) of ∼0.2. This work provides formulae for optimising cryogenic consumption and calculating cryogenic boil-off, associated with current leads used to make J{sub c} measurements, made by uniformly ramping the current up to a maximum current (I{sub max}) and then reducing the current very quickly to zero. They include consideration of the effects of duty cycle, static helium boil-off from the magnet and Dewar (b{sup ′}), and the maximum safe temperature for the critical-current leads (T{sub max}). Our optimized critical-current leads have a boil-off that is about 30% less than leads optimized for magnet operation at the same maximum current. Numerical calculations show that the optimum cross-sectional area (A) for each current lead can be parameterized by LI{sub max}/A=[1.46D{sup −0.18}L{sup 0.4}(T{sub max}−300){sup 0.25D{sup −{sup 0{sup .{sup 0{sup 9}}}}}}+750(b{sup ′}/I{sub max})D{sup 10{sup −{sup 3I{sub m}{sub a}{sub x}−2.87b{sup ′}}}}]× 10{sup 6}A m{sup −1} where L is the current lead's length and the current lead is operated in liquid helium. An optimum A of 132 mm{sup 2} is obtained when I{sub max} = 1000 A, T{sub max} = 400 K, D = 0.2, b{sup ′} = 0.3 l h{sup −1} and L = 1.0 m. The optimized helium consumption was found to be 0.7 l h{sup −1}. When the static boil-off is small, optimized leads have a boil-off that can be roughly parameterized by: b/I{sub max } ≈ (1.35 × 10{sup −3})D{sup 0.41} l h{sup ‑1} A{sup −1}. A split-current-lead design is employed to minimize the rotation of the probes during the high current measurements in our high-field horizontal magnet. The variable-temperature system is based on the use of an inverted insulating cup that operates above 4.2 K in liquid helium and above 77.4 K in liquid nitrogen, with a stability of ±80 mK to ±150 mK. Uniaxial strains of −1.4% to 1.0% can be applied to the sample, with a total uncertainty of better than ±0.02%, using a modified bending beam apparatus which includes a copper beryllium springboard-shaped sample holder.

43 PARTICLE ACCELERATORS↗

Detection of vapor nanobubbles by small angle neutron scattering (SANS)

Experiments using boiling water on untreated (roughness 100–300 nm) metal surfaces using small-angle neutron scattering (SANS) show the appearance of structures that are 50–70 nm in size when boiling is present. The scattering signal disappears when the boiling ceases, and no change in the signal is detected at any surface temperature condition below saturation. This confirms that the signal is caused by vapor nanobubbles. Two boiling regimes are evaluated herein that differ by the degree of subcooling (3–10 °C). A polydisperse spherical model with a log-normal distribution fits the SANS data well. In conclusion, the size distribution indicates that a large number of nanobubbles exist on the surface during boiling, and some of them grow into large bubbles.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessment of an E10 gasoline surrogate: Qualitative and quantitative comparisons of in-cylinder spray morphology

A minimum-component gasoline fuel surrogate that captures both chemical and physical behaviors of a full-distillate fuel is needed for high-fidelity CFD simulations. This study evaluates gasoline spray characteristics in a direct-injection spark-ignition engine under motored operation. Two fuels are compared; PACE-20, which is a 9-component surrogate formulation of RD5-87, is compared with its target fuel RD5-87, which is a full-boiling range research grade E10 gasoline. The spray morphologies of both fuels are recorded for a centrally-located direct-injection 8-hole spray subject to intake air cross-flow during the early part of the intake stroke. High-speed imaging recorded scattered light of the side and axial projections of the liquid spray. Quantitative metrics were developed and employed to facilitate comparison of spray morphologies as well as to identify the transition in spray morphology due to flash boiling. This paper builds on a previous study of RD5-87 where coolant temperature (20°C–100°C), in-cylinder pressure (40–110 kPa), engine speed (650–1950 rpm), and injection pressure (60–180 bar) were systematically changed to span operating conditions with and without flash boiling. Images of the PACE-20 morphology are selected for a sub-set of operating conditions from the previous study where distinctive morphology changes occurred. Visual inspection of the images and quantitative metrics demonstrate that the PACE-20 spray morphology is equivalent to that of the RD5-87 in most cases. The exception was for changes in the ambient-gas pressure where the flash-boiling transition occurred at ∼5 kPa higher in-cylinder pressure for PACE-20. Three empirical metrics, Merging Index, Asymmetry, and Flash Index are proposed here and they were found to be useful both as quantitative comparisons of the fuel morphologies, and for identifying the transition in spray morphology due to flash boiling.

Kim, Namho↗