Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

SSL Pricing and Efficacy Trend Analysis for Utility Program Planning

Report to help utilities and energy efficiency organizations forecast the order in which important SSL applications will become cost-effective and estimate when each "tipping point" will be reached. Includes performance trend analysis from DOE's LED Lighting Facts® and CALiPER programs plus cost analysis from various sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilizing Commercial Real Estate Owner and Investor Data to Analyze the Financial Performance of Energy Efficient, High-Performance Office Buildings

Evidence has shown that owning and operating energy-efficient, high-performance, “green” properties results in multiple benefits including lower utility bills, higher rents, improved occupancy, and greater net operating income. However, it is difficult to isolate and control moderating factors to identify the specific drivers behind improved financial performance and value to investors that results from sustainability in real estate. DOE is interested in facilitating deeper investigation of the correlation between energy efficiency and financial performance, reducing data acquisition and matching challenges, and developing a stronger understanding of how sustainable design and energy efficiency impact value. DOE commissioned this pilot study to test the logistical and empirical procedures required to establish a Commercial Real Estate Data Aggregation & Trends Analysis lab, determine the potential benefits available through the lab, and contribute to the existing body of evidence in this field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Exploring Renewable Energy Opportunities in Select Southeast Asian Countries: A Geospatial Analysis of the Levelized Cost of Energy of Utility-Scale Wind and Solar Photovoltaics

The costs of renewable energy-based electricity generation have fallen precipitously in recent years to levels that are increasingly competitive with traditional generation such as fossil fuel-based generation. As these costs become increasingly competitive, private developers, policymakers, and energy system planners are searching for opportunities to harness high-quality renewable energy resources. Developing economies are setting ambitious targets and exploring how cost-effective, grid-connected renewable energy options can help power economic growth and meet growing electricity demands. This includes the member states of the Association of Southeast Asian Nations (ASEAN) that are determined to reach a target of 23% of renewable energy in the region's total primary energy supply by 2025. A critical gap to identifying opportunities and scaling up renewable energy is the lack of quality data and analyses to support decisions on the investment and deployment of renewables - including wind and solar photovoltaics (PV). This work supports decision making by providing high-quality data and spatial analysis of the cost of utility-scale wind and solar PV generation in select countries of Southeast Asia - specifically, the ASEAN member states. Generation costs are expressed as the levelized cost of energy (LCOE) - a commonly used metric that represents the net present value of the unit cost of electricity during the lifetime of a particular electricity generation technology. This is the first spatial estimate of LCOE for these technologies within the ASEAN member states - providing insights into the roles that renewable energy resource quality and other factors may play in generation costs.

14 SOLAR ENERGY↗

Drivers of the Resource Adequacy Contribution of Solar and Storage for Florida Municipal Utilities

Solar’s variable generation limits its contribution to reliably meeting peak demand, or its resource adequacy contribution. Energy storage is a leading option to increase solar’s resource adequacy contribution, yet the contribution from different configurations of solar and storage is not widely understood. We develop methods for exploring the primary drivers of an estimate of the resource adequacy contribution of solar and storage, and we apply the methods to a case study in Florida, where demand peaks in winter and summer. We find that the portion of solar nameplate capacity that contributes to resource adequacy—its capacity credit—is less than 50% and that it declines with increasing solar penetration. The capacity credit of storage, even though it is fully controllable by the system operator, strongly depends on the duration of storage. The capacity credit of 1 hour of storage can be less than the capacity credit of solar. Achieving a 90% capacity credit requires at least 4–5 hours of storage when storage capacity is small relative to the system peak. As storage deployment increases to 20% of the peak demand, 9 hours—and sometimes more than 10 hours—of storage are needed to achieve a 90% capacity credit. Increased solar deployment at the system level can increase storage’s capacity credit. Directly pairing solar and storage can also impact the capacity credit. Storage with a power rating similar to the solar inverter rating loses capacity credit when coupled with solar if its duration is more than 1–2 hours, because storage competes with solar for use of the inverter. On the other hand, there is no reduction in capacity credit when the storage is small relative to the solar inverter. The approach and tools developed here for exploratory analysis can be useful for many other utilities and regions grappling with similar preliminary questions, prior to evaluation of specific cases using more detailed and resource-intensive modeling.

14 SOLAR ENERGY↗

Beyond Benchmarking : Unlocking the Value for Utilities

This document provides guidance to help utilities identify new, untapped datasets related to the energy performance of buildings, and how this information can be applied to expand market intelligence and create business value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmentally Safe, Large Volume Utilization Applications for Gasification Byproducts

Samples of gasification by-products produced at Polk Station and Eastman Chemical were obtained and characterized. Bulk samples were prepared for utilization studies by screening at the appropriate size fractions where char and vitreous frit distinctly partitioned. Vitreous frit was concentrated in the +20 mesh fraction while char predominated in the -20+100 mesh fraction. The vitreous frit component derived from each gasifier slag source was evaluated for use as a pozzolan and as aggregate. Pozzolan testing required grinding the frit to very fine sizes which required a minimum of 60 kwhr/ton. Grinding studies showed that the energy requirement for grinding the Polk slag were slightly higher than for the Eastman slag. Fine-ground slag from both gasifiers showed pozzoalnic activity in mortar cube testing and met the ASTM C618 strength requirements after only 3 days. Pozzolanic activity was further examined using British Standard 196-5, and results suggest that the Polk slag was more reactive than the Eastman slag. Neither aggregate showed significant potential for undergoing alkali-silica reactions when used as concrete aggregate with ASTM test method 1260. Testing was conducted to evaluate the use of the frit product as a component of cement kiln feed. The clinker produced was comprised primarily of the desirable components Ca{sub 3}SiO{sub 5} and Ca{sub 2}SiO{sub 4} after raw ingredient proportions were adjusted to reduce the amount of free lime present in the clinker. A mobile processing plant was designed to produce 100 tons of carbon from the Eastman slag to conduct evaluations for use as recycle fuel. The processing plant was mounted on a trailer and hauled to the site for use. Two product stockpiles were generated; the frit stockpile contained 5% LOI while the carbon stockpile contained 62% LOI. The products were used to conduct recycle fuel tests. A processing plant was designed to separate the slag produced at Eastman into 3 usable products. The coarse frit has been shown to be suitable for use as clinker feed for producing Portland cement. The intermediate-size product is enriched in carbon (58-62% C) and may be used as recycle fuel either in the gasifier or in a PC boiler. The fines product contains 30-40% C and may also be used as a recycle gasifier fuel, as is presently done at TECO's Polk Station, however, due to gasifier operating requirements for the production of syngas, this is not feasible at Eastman.

01 COAL, LIGNITE, AND PEAT↗

Utility-Scale Solar, 2021 Edition

Berkeley Labs "Utility-Scale Solar", 2021 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2020, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, and interconnection queue data.

2021↗

United States Utility-Scale PV Supply Curves 2023

This data packet contains supply curves, hourly generation profiles, and a composite siting exclusion TIFF for utility-scale PV across the contiguous United States. The supply curves offer comprehensive metrics such as capacity (MW), generation (MWh), levelized cost of energy (LCOE), levelized cost of transmission (LCOT), and more for each reV site (~60,000 sites). Hourly generation profiles are available for each reV site and can be matched to the available capacity in the supply curve (refer to the Jupyter Notebook). The composite exclusion TIFF is a single file that delineates areas where PV installations are permissible based on various siting assumptions. This data packet contains information for the Reference and Limited siting scenarios. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

2023↗

Utility-Scale Solar, 2024 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2024 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2023, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, net value, and interconnection queue data.

analysis↗

The Urban Energy-Water Nexus: Utility-Level Water Flows and Embedded Energy

There are limited open source data available for determining water production/treatment and required energy for cities across the United States. This database represents the culmination of a two-year effort to obtain data from cities across the United States via open records requests in order to determine the state of the U.S. urban energy-water nexus. Data were requested at the daily or monthly scale when available for 127 cities across the United States, represented by 253 distinct water and sewer districts. Data were requested from cities larger than 100,000 people and from each state. In the case of states that did not have cities that met these criteria, the largest cities in those states were selected. The resulting database represents a drinking water service population of 81.4 million and a wastewater service population of 86.2 million people. Average daily demands for the United States were calculated to be 560 liters per capita for drinking water and 500 liters per capita of wastewater. The embedded energy within each of these resources is 340 kWh/1000 m3 and 430 kWh/1000 m3, respectively. Drinking water data at the annual scale are available for production volume (89 cities) and for embedded energy (73 cities). Annual wastewater data are available for treated volume (104 cities) and embedded energy (90 cities). Monthly data are available for drinking water volume and embedded energy (73 and 56 cities) and wastewater volume and embedded energy (88 and 70 cities). Please see the two related papers for this metadata are included with this submission. Each folder name is a city that contributed data to the collection effort (City+State Abbreviation). Within each folder is a .csv file with drinking water and wastewater volume and energy data. A READ-ME file within each folder details the contents of the folder within any relevant information pertaining to data collection. Data are on the order of a monthly timescale when available, and yearly if not. Please cite the following papers when using the database: Chini, C.M. and Stillwell, A.S. (2017). The State of U.S. Urban Water: Data and the Energy-Water Nexus. Water Resources Research. 54(3). DOI: https://doi.org/10.1002/2017WR022265 Chini, C.M., and Stillwell, A. (2016). Where are all the data? The case for a comprehensive water and wastewater utility database. Journal of Water Resources Planning and Management. 143(3). DOI: 10.1061/(ASCE)WR.1943-5452.0000739

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Resources for Utility Regulators

Provides a summary of State and Local Energy Efficiency Action Network (SEE Action) information resources available to utility regulators, organized by topic.

regulators↗

Exploring New Models for Utility Distributed Energy Resource Planning and Integration: SMUD and Con Edison

As a result of the rapid growth of renewable energy in the United States, the U.S. electric grid is undergoing a monumental shift away from its historical status quo. These changes are occurring at both the centralized and local levels and have been driven by a number of different factors, including large declines in renewable energy costs, federal and state incentives and mandates, and advances in the underlying technology. Higher levels of variable-generation renewable energy, however, may require new and increasingly complex methods for utilities to operate and maintain the grid while also attempting to limit the costly build-out of supporting grid infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic and Emissions Analysis of the Hybrid Redox Process for the Production of Acetic Acid with CO 2 Utilization

The production of oxygenated hydrocarbons, such as acetic acid, using captured CO 2 is a promising pathway to reduce greenhouse gas emissions in the chemical industry. The use of a chemical looping‐based hybrid redox process (HRP) is proposed to convert CO 2 and natural gas into separate CO and syngas streams that can be used to produce various commodity oxygenates, while allowing the beneficial utilization of captured CO 2 . Here, a detailed technoeconomic analysis of HRP applied to the production of acetic acid is presented. Emissions and energy analyses show the ability of HRP to lower the CO 2 emissions for acetic acid synthesis by 74% compared to a conventional steam and autothermal reforming route. HRP also offers a potential 34% reduction in capital costs. Compared to a dry reforming based acetic acid production route, HRP has the potential for significantly lower costs. If integrated with a low carbon energy source, HRP has the potential to achieve a negative emission of greenhouse gas (‐0.50 kg CO 2 per kg acetic acid).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Need for and Path to Harmonized Life Cycle Assessment and Techno-Economic Assessment for Carbon Dioxide Capture and Utilization

The use of carbon dioxide as a feedstock for a broad range of products can help mitigate the effects of climate change through long-term removal of carbon or as part of a circular carbon economy. Research on capture and conversion technologies has intensified in recent years, and the interest in deploying these technologies is growing fast. However, sound understanding of the environmental and economic impacts of these technologies is required to drive fast deployment and avoid unintended consequences. Life cycle assessments (LCAs) and techno-economic assessments (TEAs) are useful tools to quantify environmental and economic metrics; however, these tools can be very flexible in how they are applied, with the potential to produce significantly different results depending on how the boundaries and assumptions are defined. Built on ISO standards for generic LCAs, several guidance documents have emerged recently from the Global CO 2 Initiative, the National Energy Technology Laboratory, and the National Renewable Energy Laboratory that further define assessment specifications for carbon capture and utilization. Overall agreement in the approaches is noted with differences largely based on the intended use cases. As a results, further guidance is needed for assessments of early-stage technologies, reporting details, and reporting for policymakers and nontechnical decision-makers.

09 BIOMASS FUELS↗

Determination of a version of a unit for synchronous cleaning and utilization of gas exhausts from heat generators

Versions for performing synchronous cleaning and utilization of flue gases, calculation schemes and basic equations for defining them, engineering schemes with an indication of the main equipment for these versions, are considered. The possibility is demonstrated of improving the ecological safety of a boiler unit simultaneously with a reduction in discharge of heat into the environment.

01 COAL, LIGNITE, AND PEAT↗

Enhanced carbon-transfer and -utilization efficiencies achieved using membrane carbonation with gas sources having a range of CO 2 concentrations

The economic viability of microalgal biofuels relies on increasing productivity in a cost-effective manner. As microalgal biomass contains > 50% carbon, a high rate of CO 2 delivery is required for high productivity, and inefficient CO 2 delivery amplifies operating costs. Membrane carbonation using non-porous hollow fiber membranes can ideally deliver CO 2 without bubble formation and high carbon transfer efficiency. Because CO 2 streams from industrial resources are not 100% CO 2 , the buildup of inert gasses can significantly lower the CO 2 delivery rate when the distal end of the membrane is closed. To overcome the buildup of inert gases, we managed the distal end of the membranes with three different approaches: fully open end, restricted bleed valve, and restricted bleed valve with pH-actuated venting. For all approaches, CO 2 was delivered to membranes ondemand based on a pH set point. Evaluating a wide range of CO 2 concentrations (10% to 100%), we found that all approaches eliminated the buildup of inert gases, could maintain target pH values and gave the same biomass productivities and carbon distributions. However, carbon transfer efficiency depended on the operation of the distal end. Fully open-end operation gave a poor carbon transfer efficiency because of excessive loss of CO 2 from the distal end. However, restricting the exit flow rate to ≤4 cm 3 /min mitigated the problems of excessive CO 2 loss, but without incurring a large loss of CO 2 -delivery flux. For the continuous cultivation, combining a restricted bleed valve with pH-actuated venting improved the carbon-transfer efficiency and -utilization efficiencies up to 85% and 67%, respectively, with a sufficient CO 2 delivery flux.

42 ENGINEERING↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗