Preliminary Observations from Corehole Drilling in an Active Fault Zone in Rock Valley, Nevada
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Civil infrastructure such as culverts and bridges are commonly designed using precipitation-based intensity-duration-frequency (PREC-IDF) curves, which assume that the occurrence of precipitation is in the form of rainfall and immediately available for the rainfall-runoff process. In snow-dominated regions, where most winter precipitation occurs as snow that melts during spring to early summer, the use of standard PREC-IDF curves may lead to substantial underestimation of design floods and high failure risk of infrastructure. In this context, we developed next-generation IDF (NG-IDF) curves that characterize the actual water reaching the land surface (i.e., rainfall plus snowmelt) to enhance standard infrastructure design in snow-dominated regions. This study evaluates the performance of NG-IDF curves coupled with U.S. Department of Agriculture Technical Release 55 hydrologic model in estimating design floods for 246 snowy locations in different hydroclimate regimes of the western United States. Design flood estimates from a well-validated continuous simulation using a physics-based hydrologic model, the Distributed Hydrology Soil Vegetation Model (DHSVM), were used as the performance benchmark. Compared with the benchmark estimates, the standard PREC-IDF curves led to substantial errors in design flood estimates while the NG-IDF curves significantly reduced these errors. For example, the averaged error in the 50-year design flood estimates over the 246 locations was reduced from 31% with the use of PREC-IDF curves to 12% with the use of NG-IDF curves. Despite the different model structures, the single-event NG-IDF approach versus the continuous simulation DHSVM did not exhibit statistically significant differences in 91% of the 246 locations for the 50-year design flood estimates. We find this indicates a satisfactory performance of NG-IDF curves to estimate design flow under the conditions tested in the snow-dominated western United States. This article also presents technical suggestions and the limitations of infrastructure design using NG-IDF curves for regulatory agencies and practicing engineers.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The sooting tendencies of 20 bio-derived fuels indicated as potential blendstocks for spark-ignition engines by the Co-Optimization of Fuels & Engines (Co-Optima) Initiative are studied. The Yield Sooting Index (YSI) is used to quantify the sooting tendencies. The Co-Optima Chemical Model is used to predict the numerical YSIs for all test fuels, and these results are compared with measurements. Experimental YSIs are newly measured for 2 furans and are taken from our previous work for the other compounds. Overall, the predicted YSIs agree well with measurements, within the experimental uncertainties, except for 2,5-dimethylfuran (2,5-DMF). It is found that Polycyclic Aromatic Hydrocarbons (PAH) growth reactions have little influence on the relative soot production from each fuel and therefore on YSI predictions. A modified sensitivity coefficient formulation is proposed to evaluate reaction sensitivities specifically for YSI. This formulation is applied to the 2,5-DMF-doped flame, and six 2,5-DMF initial decomposition reactions, which lead to different major soot precursors, are identified as the most sensitive reactions. The impact of the chemical kinetic uncertainties embedded in these reactions is quantified by randomly perturbing their reaction rates within a factor of two. The resulting prediction uncertainty in the 2,5-DMF-doped flame is found to be ± 8 YSI units (±11%), which demonstrates that the test-fuel-specific decomposition reactions indeed have considerable influence on its YSI prediction. Our research suggests that more accurate kinetic parameters for fuel initial decomposition reactions can potentially improve YSI predictions effectively, without altering the YSI predictions of other fuels with significantly different molecular structures.
The lab sorbent testing finalized the sorbent composition and operating conditions for the integrated unit. The bench unit design included COMSOL simulation to finalize the coil design and select initial operating conditions of the power supply system. Fluidized bed testing with the induction heating verified that a heating efficiency of up to 90% can be achieved. The integrated bench unit operations provided valuable data confirming the feasibility of using induction heating for the desorption of CO2. Major challenge observed was the limited working capacity of the sorbent, requiring additional development in future projects. In addition, a large-scale reactor demonstration is required to mitigate the risk of uniform temperature distribution and heating efficiency over a large cross-sectional area when using induction heating.
The Savannah River National Laboratory (SRNL) has supported the Saltstone Production Facility (SPF) since its conception. However, bench scaled tests have not always provided process or performance data related to the mixing, transfer, and other operations utilized in the SPF. A need was identified to better understand the SPF processes and to have the capabilities at SRNL to simulate the SPF unit operations to support an active low-level radioactive waste (LLW) processing facility. At the SPF, the dry premix is weighed, mixed and transferred to the Readco '10-inch' continuous mixer where it is mixed with the LLW salt solution from the Salt Feed Tank (SFT) to produce fresh Saltstone slurry. The slurry is discharged from the mixer into a hopper. The hopper feeds the grout pump that transfers the slurry through at least 457.2 meters of piping and discharges it into the Saltstone Disposal Units (SDU) for permanent disposal. In conjunction with testing individual SPF processes over several years, SRNL has designed and fabricated a scaled Saltstone Facility. Scaling of the system is primarily based on the volume capacity of the mixer and maintaining the same shear rate and total shear at the wall of the transfer line. At present, SRNL is utilizing the modular capabilities of the scaled Saltstone Facility to investigate the erosion issues related to the augers and paddles inside the SPF mixer. Full implementation of the scaled Saltstone Facility is still ongoing, but it is proving to be a valuable resource for testing alternate Saltstone formulations, cleaning sequences, the effect of pumping Saltstone to farther SDU's, optimization of the SPF mixer, and other operational variables before they are implemented in the SPF. (authors)
The neutron power of the reactor of the Yenisei space nuclear power plant is measured in absolute units using the modernized method of correlation analysis during the ground-based tests of the Yenisei prototypes. Results of the experiments are given. The desired result is obtained in a series of experiments carried out at the stage of the plant preparation for tests. The acceptability of experimental data is confirmed by the results of measuring the reactor neutron power in absolute units at the nominal level by the thermal balance during the life cycle tests of the ground prototypes.
The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this “solo” test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. In an attempt to create a simplified tool for predicting leakage to the outside, Building America team Consortium for Advanced Residential Buildings (CARB) performed a preliminary statistical analysis on blower door test results from 112 attached dwelling units in four apartment complexes. Although the subject data set is limited in size and variety, the preliminary analyses suggest significant predictors are present and support the development of a predictive model. Further data collection is underway to create a more robust prediction tool for use across different construction types, climate zones, and unit configurations.
Power restoration is an urgent task after a black-out, and recovery efficiency is critical when quantifying system resilience. Multiple elements should be considered to restore the power system quickly and safely. This paper proposes a recovery model to solve a direct-current optimal power flow (DCOPF) based on mixed-integer linear programming (MILP). Since most of the generators cannot start independently, the interaction between black-start (BS) and non-black-start (NBS) generators must be modeled appropriately. The energization status of the NBS is coordinated with the recovery status of transmission lines, and both of them are modeled as binary variables. Also, only after an NBS unit receives the cranking power through connected transmission lines, will it be allowed to participate in the following system dispatch. The amount of cranking power is estimated as a fixed proportion to the maximum generation capacity. The proposed model is validated on several test systems, as well as a 1393-bus representation system of the Puerto Rican electric power grid. Test results demonstrate how the recovery of NBS units and damaged transmission lines can be optimized, resulting in an efficient and well-coordinated recovery procedure.
Sandia is participating in the third phase of a United States (US)-German Joint Project that compares constitutive models and simulation procedures on the basis of model calculations of the thermomechanical behavior and healing of rock salt (Salzer et al. 2015). The first goal of the project is to evaluate the ability of numerical modeling tools to correctly describe the relevant deformation phenomena in rock salt under various influences. Among the numerical modeling tools required to address this are constitutive models that are used in computer simulations for the description of the thermal, mechanical, and hydraulic behavior of the host rock under various influences and for the long-term prediction of this behavior. Achieving this goal will lead to increased confidence in the results of numerical simulations related to the secure disposal of radioactive wastes in rock salt. Results of the Joint Project may ultimately be used to make various assertions regarding stability analysis of an underground repository in salt during the operating phase as well as long-term integrity of the geological barrier in the post-operating phase A primary evaluation of constitutive model capabilities comes by way of predicting large-scale field tests. The Joint Project partners decided to model Waste Isolation Pilot Plant (WIPP) Rooms B & D which are full-scale rooms having the same dimensions. Room D deformed under natural, ambient conditions while Room B was thermally driven by an array of waste-simulating heaters (Munson et al. 1988; 1990). Existing laboratory test data for WIPP salt were carefully scrutinized and the partners decided that additional testing would be needed to help evaluate advanced features of the constitutive models. The German partners performed over 140 laboratory tests on WIPP salt at no charge to the US Department of Energy (DOE).
Explore the source record for details and available documents.
This paper developed an algorithm that controls the supply air temperature in the variable refrigerant flow (VRF), outdoor air processing unit (OAP) system, according to indoor and outdoor temperature and humidity, and verified the effects after applying the algorithm to real buildings. The VRF-OAP system refers to a heating, ventilation, and air conditioning (HVAC) system to complement a ventilation function, which is not provided in the VRF system. It is a system that supplies air indoors by heat treatment of outdoor air through the OAP, as a number of indoor units and OAPs are connected to the outdoor unit in the VRF system simultaneously. This paper conducted experiments with regard to changes in efficiency and the cooling capabilities of each unit and system according to supply air temperature in the OAP using a multicalorimeter. Based on these results, an algorithm that controlled the temperature of the supply air in the OAP was developed considering indoor and outdoor temperatures and humidity. The algorithm was applied in the test building to verify the effects of energy reduction and the effects on indoor temperature and humidity. Loads were then changed by adjusting the number of conditioned rooms to verify the effect of the algorithm according to various load conditions. In the field test results, the energy reduction effect was approximately 15–17% at a 100% load, and 4–20% at a 75% load. However, no significant effects were shown at a 50% load. The indoor temperature and humidity reached a comfortable level.
The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek{sup R} Rotary Micro-filter units to determine the behavior of a multiple filter system and develop a multi-filter automated control scheme. Developing and testing the control of multiple filters was the next step in the development of the rotary filter for deployment. The test stand was assembled using as much of the hardware planned for use in the field including instrumentation and valving. The control scheme developed will serve as the basis for the scheme used in deployment. The multi filter setup was controlled via an Emerson DeltaV control system running version 10.3 software. Emerson model MD controllers were installed to run the control algorithms developed during this test. Savannah River Remediation (SRR) Process Control Engineering personnel developed the software used to operate the process test model. While a variety of control schemes were tested, two primary algorithms provided extremely stable control as well as significant resistance to process upsets that could lead to equipment interlock conditions. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The equipment selected for deployment, including the concentrate discharge control valve, the pressure transmitters, and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual rotary filter system. Experience acquired on a multi-filter system behavior and with the system layout during this test helped to identify areas where the current deployment rotary filter installation design could be improved. Completion of this testing provides the necessary information on the control and system behavior that will be used in deployment on actual waste. (authors)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This paper argues that Governments have sought to streamline impact assessment in recent years (defined as the last five years) to counter concerns over the costs and potential for delays to economic development. We hypothesise that this has had some adverse consequences on the benefits that subsequently accrue from the assessments. This hypothesis is tested using a framework developed from arguments for the benefits brought by Environmental Impact Assessment made in 1982 in the face of the UK Government opposition to its implementation in a time of economic recession. The particular benefits investigated are ‘consistency and fairness’, ‘early warning’, ‘environment and development’, and ‘public involvement’. Canada, South Africa, the United Kingdom and Western Australia are the jurisdictions tested using this framework. The conclusions indicate that significant streamlining has been undertaken which has had direct adverse effects on some of the benefits that impact assessment should deliver, particularly in Canada and the UK. The research has not examined whether streamlining has had implications for the effectiveness of impact assessment, but the causal link between streamlining and benefits does sound warning bells that merit further investigation. -- Highlights: • Investigation of the extent to which government has streamlined IA. • Evaluation framework was developed based on benefits of impact assessment. • Canada, South Africa, the United Kingdom, and Western Australia were examined. • Trajectory in last five years is attrition of benefits of impact assessment.