At least 901 records · Page 50

Pressure instrumentation for gas turbine engines - A review of measurement technology

Many types and designs of pressure measuring instrumentation are used during the development and testing of gas turbine engines. This paper provides an overview of more commonly available pressure transducers and their characteristics. Probe designs for use in both steady-state and dynamic pressure measurement systems are reviewed. Techniques used to qualify instrument probes and the methods used to calibrate pressure transducers during engine testing are described.

Armentrout, E. C.↗

Ultrasonic analysis of bolt preloads

This paper covers an investigation into the feasibility of analyzing bolt preloads by ultrasonic techniques. Various techniques were evaluated and a pulse echo inteferometric method was selected for experimental testing. In agreement with theoretical predictions, the interferometer response was found to be linearly related to tensile stresses oriented parallel to the bolt axis. Under rather idealized conditions, bolt loads can be determined with errors of less than 1%. The ultimate operational accuracy depends on a number of variables, such as bolt dimensions and geometry, bolt temperature, uniformity of stresses, and bolt materials, but load analyses to within + or - 3% are readily achievable. Best results are obtained with the ultrasonic transducer contact coupled to a small flat area near the center of the bolt head. The transducer can be applied and measurements made without interfering with normal wrenching operations. Prototype instrumentation is described and calibration results are tabulated for numerous bolt sizes and materials.

Rollins, F. R., Jr.↗

Acoustic emission testing of composite vessels under sustained loading

Acoustic emission (AE) tests have been conducted on small-diameter Kevlar 49/epoxy pressure vessels subjected to long-term sustained load-to-failure tests. Single-cycle burst tests were used as a basis for determining the test pressure in the sustained-loading tests. AE data from two vessel locations were compared. The data suggest that AE from vessel wall-mounted transducers is quite different for identical vessels subjected to the same pressure loading. AE from boss-mounted transducers yielded relatively consistent values. These values were not a function of time for vessel failure. The development of an AE test procedure for predicting the residual service life or integrity of composite vessels is discussed.

Lark, R. F.↗

A monolithic SAW-charge transfer device

Surface acoustic waves excited in a Si-SiO2-ZnO layered structure can produce a traveling electric field in the silicon substrate. Charges stored in the traveling potential wells can be transferred at high speed and density and with less complexity. The monolithic structure under investigation for the SAW-charge transfer device consists of a silicon substrate, a thin silicon dioxide insulating layer on top of which a ZnO piezoelectric film is deposited by sputtering. The surface acoustic waves are excited by interdigital transducers. The signal charge is injected into traveling potential wells that travel with the velocity of sound. Conditions for the transfer of the charges by the traveling wells are analyzed. A surface acoustic wave program was used to determine the optimum structure dimensions and transducer configuration which will produce the highest coupling in the excitation of the piezoelectric waves.

Papanicolaou, N. A.↗

Fiber optic sensors for military, industrial and commercial applications

Four examples of specific fiber optic sensor system designs, each of which demonstrates a different optical modulation format, are described. The birefrigent temperature transducer illustrates direct digital signal modulation. The temperature/pressure dependent semiconductor filter illustrates high-pass optical wavelength signal encoding. The coupled polarized-mode transducer shows how a solid-state sensor can produce narrow-bandpass optical wavelength signal encoding. The luminescent temperature sensor illustrates a way to construct a solid state sensor in order to produce pulse width modulation of an optical signal.

James, K. A.↗

Thrust oscillations of the Space Shuttle solid rocket Booster motor during static tests

Thrust oscillations have occurred during static tests of Space Shuttle Booster solid rocket motors. These oscillations in measured axial thrust occurred primarily near 15 Hz; these oscillations late in the motor burn reach magnitudes up to approximately + or - 3% of motor thrust. The phenomenon has consistently occurred on the four demonstration motors which have been static tested and appears to be associated with small amplitude, 15 Hz pressure oscillations inside the motor. The source of the pressure oscillations is thought to be associated with the fundamental longitudinal acoustic resonance of the motor at 15 Hz. These thrust oscillations potentially can impact the design of the Space Shuttle vehicle structure. The demonstration motors have been instrumented with an array of transducers to aid in understanding the phenomenon. In addition to measuring axial and lateral thrust of the motor, pressure transducers were located to measure chamber pressure oscillations at the forward dome. Accelerometers and extensometers have measured motions of the structure. A modal survey was conducted on a fired motor to identify its structural dynamic characteristics, and these data were used to validate mathematical models of the motor in the static test facility.

Mason, D. R.↗

Telemetry of intracranial pressure

A completely implantable epidural pressure telemetry system designed for accurate measurement of intracranial pressure (ICP) is described. The implant device is batteryless, providing unlimited operating life. The described system uses a capacitive pressure transducer with excellent long-term stability. Once detected with the transducer and converted to a frequency with the oscillator electronics, the pressure signal is digitized. It is then telemetered without the possibility of further degradation. After detection with the small external module, the data can be retransmitted by a radio link for complete patient mobility or the energizer signal pickup module can be wired to a bedside readout unit. Continuous data are available from the system so that the dynamic ICP changes reflecting arterial blood pressure can be observed and used for diagnosis.

Fryer, T. B.↗

Influence of phase cancellation and pulse shape artifacts on ultrasonic spectrum analysis

Both continuous wave and Fourier transformed pulse ultrasonic spectroscopy are being applied to material and flow characterization. Ideal samples and flaws (flat, parallel, and homogeneous) and ideal ultrasonic apparatus (producing delta function stress waves) provide acoustic spectra which can be partially inverted. However, in the presence of material inhomogeneity, lack of sample flatness or parallelism, or finite risetime pulses, the spectra become quite complex and produce phase cancellations at the transducer as well as pulse shape spectral artifacts. In this paper, we examine the nature of these artifacts for both simple and practical samples. Sample spectra are contrasted for several different transducer/electronic systems. Spectra obtained with a phase insensitive acousto-electric transducer (AET) combined with a frequency tracked tone-burst spectroscopy (TBS) method are presented. Analysis of the test configuration is shown to produce spectra consistent with that obtained with the AET-TBS combination.

Heyman, J. S.↗

Eddy-current sensor measures bolt loading

Thin wire welded to bottom of hole down center of bolt permits measurement of tension in bolt. Bolt lengthens under strain, but wire is not loaded, so gap between wire and eddy-current gap transducer mounted on bolt head indicates bolt loading. Eddy-current transducer could measure gap within 0.05 mm. Method does not require separate "standard" for each bolt type, and is not sensitive to dirt or oil in bolt hole, unlike ultrasonic probes.

Burr, M. E.↗

Ultrasonic attenuation and velocity in AS/3501-6 graphite/epoxy fiber composite

The ultrasonic group velocity and attenuation were measured as a function of frequency for longitudinal and shear waves in the epoxy matrix (3501-6) and in the principal directions of the unidirectional graphite/epoxy composite (AS/3501-6). Tests were conducted in the frequency ranges 0.25 Mz to 14 MHz and 0.5 Mz to 3 MHz for longitudinal and shear wave modes, respectively. The attenuation increased with frequency for all wave modes, but the group velocity was independent of frequency for all wave modes. The effects of pressure and couplant at the transducer-specimen interface were studied and it was found that for each transducer type there exists a frequency dependent 'saturation pressure' corresponding to the maximum output signal amplitude.

Williams, J. H., Jr.↗

Digital system for dynamic turbine engine blade displacement measurements

An instrumentation concept for measuring blade tip displacements which employs optical probes and an array of micro-computers is presented. The system represents a hitherto unknown instrumentation capability for the acquisition and direct digitization of deflection data concurrently from all of the blade tips of an operational engine rotor undergoing flutter or forced vibration. System measurements are made using optical transducers which are fixed to the case. Measurements made in this way are the equivalent of those obtained by placing three surface-normal displacement transducers at three positions on each blade of an operational rotor.

Kiraly, L. J.↗

Stress wave attenuation in thin structures by ultrasonic through-transmission

The steady state amplitude of the output of an ultrasonic through transmission measurement is analyzed and the result is given in closed form. Provided that the product of the input and output transduction ratios; the specimen-transducer reflection coefficient; the specimen-transducer phase shift parameter; and the material phase velocity are known, this analysis gives a means for determining the through-thickness attenuation of an individual thin sample. Multiple stress wave reflections are taken into account and so signal echoes do not represent a difficulty. An example is presented for a graphite fiber epoxy composite (Hercules AS/3501-6). A direct method for continuous or intermittent monitoring of through thickness attenuation of plate structures which may be subject to service structural degradation is provided.

Lee, S. S.↗

Air speed and attitude probe

An air speed and attitude probe characterized by a pivot shaft normally projected from a data boom and supported thereby for rotation about an axis of rotation coincident with the longitudinal axis of the shaft is described. The probe is a tubular body supported for angular displacement about the axis of rotation and has a fin mounted on the body for maintaining one end of the body in facing relation with relative wind and has a pair of transducers mounted in the body for providing intelligence indicative of total pressure and static pressure for use in determining air speed. A stack of potentiometers coupled with the shaft to provide intelligence indicative of aircraft attitude, and circuitry connecting the transducers and potentiometers to suitable telemetry circuits are described.

Baker, G. J.↗

Distributed-switch Dicke radiometers

A radiometer on an orbiting spacecraft is described which derives high spatial resolution information from terrestrial and atmospheric regions. The N elements or subapertures on the spacecraft transduce electromagnetic energy into electric signals. Many or all of the elements are simultaneously illuminated by electromagnetic energy radiated from the same region. Identical, parallel processing channels are responsive to the N elements. Each of the channels includes a variable gain amplifier responsive to the signal transduced by its corresponding array elements. The gain of each amplifier is controlled as a function of the output difference when the channel is connected periodically to each of a pair of Dicke noise sources, such as resistors maintained at predetermined temperatures.

Levis, C. A.↗

Detection of the transitional layer between laminar and turbulent flow areas on a wing surface

A system is disclosed for detecting the laminar to turbulent boundary layer transition on a surface while simultaneously taking pressure measurements. The system uses an accelerometer for producing electrical signals proportional to the noise levels along the surface and a transducer for producing electrical signals proportional to pressure along the surface. The signals generated by the accelerometer and transducer are sent to a data reduction system for interpretation and storage.

Hood, W. R.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere-hour nickel-cadmium spacecraft cells for the tracking data relay satellite system

Five cells provided by NASA's Goddard Space Flight Center were evaluated at room temperature and pressure (25 C plus or minus 2 C) with discharges at the 2 hour rate. Measurements of the cell containers following test, indicated an average increase of .006 inches at the plate thickness. Average end of charge voltages and pressures, and capacity output in ampere hours were determined. Three cells exceeded the voltage requirements of 1.52 volts during both c/10 charges at 20 C. All cells exceeded the voltage requirement of 1.52 volts during the 0 C overcharge test, although their end charges were below 1.50 volts. The pressure requirement of 65 psia was exceeded by both pressure transducer cells during c/10 charges at 25 C and 20 C and also during the 0 C overcharge test. The cells with pressure transducers reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test, and exhibited a pressure decay of 2 psia during the last 30 minutes of the 1 hour open circuit stand. Average capacity was 51.3 ampere hours.

Harkness, J. D.↗

Apparatus and method for determining the position of a radiant energy source

The position of a terrestrial RF source is determined from a geostationary, synchronous satellite by scanning the beam of a narrow beam width antenna in first and second orthogonal directions over a region including the source. The peak level of energy transduced by the antenna in each of the scanning directions is detected and correlated with the scanning position of the beam by feeding the output of a detector responsive to the transduced signal to an indicator of an X-Y recorder. The X and Y axes of the recorder are scanned in synchronism with the beam being respectively scanned in the first and second directions to form X and Y traces on which are indicated the detected peak position in each of the scanning directions. The source position is determined from an intersection of lines drawn parallel to the X and Y axes and including the detected peak position of each trace.

Schaefer, G. J.↗

Helmet weight simulator

A device for providing acceleration cues to the helmet of a simulator pilot is described. Pulleys are attached to both shoulders of the pilot. A cable is attached to both sides of the helmet and extends through the pulleys to a takeup reel that is controlled by a torque motor. Control signals are applied to a servo system including the torque motor, the takeup reel and a force transducer which supplies the feedback signal. In one embodiment of the invention the force transducer is in the cable and in another it is in the takeup reel.

Ashworth, B. R.↗