Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Atom Probe Tomography Analysis of Precipitation during Tempering of a Nanostructured Bainitic Steel

Carbon distribution during tempering of a nanostructured bainitic steel was analyzed by atom probe tomography (APT). Three different types of particles are detected on samples tempered at 673 K (400 C) for 30 minutes: lower bainite cementite with a carbon content of {approx}25 at. pct, {var_epsilon}-carbides with a carbon content close to 30 at. pct, and carbon clusters, small features with a carbon content of {approx}14 at. pct indicative of a stage of tempering prior to precipitation of {var_epsilon}-carbide. After tempering at 773 K (500 C) for 30 minutes, the {var_epsilon}-carbide-to-cementite transition was observed. Solute concentration profiles across carbide/ferrite interfaces showed the distribution of substitutional elements in {var_epsilon}-carbide and cementite for all the tempering conditions.

36 MATERIALS SCIENCE↗

Quantifying Pore Morphology in Spray-Formed Tantalum Using X-ray Micro-computed Tomography

In order to establish quantitative process–structure–property relationships in thermal spray coatings, a robust framework for defining (micro)structural characteristics is needed. Here, we present a quantitative characterization of the three-dimensional morphology of porosity in spray-formed tantalum samples based on high-resolution X-ray micro-computed tomography. Using synchrotron facilities, we acquired dozens of high-resolution scans, enabling a statistically meaningful comparison across multiple samples, different regions within samples, and spray processes. We quantify the spatial distribution, size, and topology of porous inclusions, with a significant focus on variability across samples and different spray processes (plasma and cold sprayed), as well as sensitivity to image segmentation and resolution. Based on a typical segmentation, we report porosities ranging from 0.9 to 1.7 pct for all samples tested, with significant sensitivity due to image segmentation resulting in estimates as low as 0.6 pct and as high as 4.8 pct. For the complex pore space morphology observed in these materials, we argue that a conventional analysis based on identifying individual pores is not well suited, and propose an alternative approach based on morphological metrics with a rich history in porous media literature, such as spatial correlations, local pore thickness, and scale-dependent sub-sampling. Spatial correlations indicate anisotropic splat structures, but only mildly anisotropic pores. Various measures of pore size show a wide distribution of sizes, ranging from sub-micron to 10-micron length scales. Scale-dependent variations in porosity suggest that representative volumes of several hundred microns are required for convergence of morphological metrics, with larger volumes for cold-spray materials. This work provides a robust quantitative basis for describing three-dimensional pore structure in thermal spray coatings.

36 MATERIALS SCIENCE↗

Emerging Role of Coronary Computed Tomography Angiography in Lipid-Lowering Therapy: a Bridge to Image-Guided Personalized Medicine

Purpose of Review: To summarize the current status of coronary computed tomography angiography (CTA) in the assessment of coronary plaques and discuss the ability of serial coronary CTA to quantitatively measure changes in the plaque burden in response to lipid-lowering therapy. Recent Findings: Recent advances in coronary CTA have allowed identification of high-risk coronary features in acute coronary syndrome and measurement of changes in the coronary plaque burden with good reproducibility. Statin therapy may delay plaque progression and change some plaque features. However, the clinical relevance of quantitative changes in coronary plaques and the optimal methods to reduce the plaque burden remain unclear. Summary: Despite guideline-directed lipid-lowering therapy, adverse events still occur in substantial numbers of patients receiving statins. Coronary CTA is noninvasive and has high diagnostic performance in patients with coronary artery disease, making change in the plaque burden an applicable biomarker for individualized assessment of future risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The high matrix acquisition technique for imaging of atherosclerotic plaque inflammation in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography with time-of-flight: Phantom study

Background: Motion artifact and partial volume effect caused underestimation of coronary plaque inflammation. This study evaluated the high matrix acquisition technique using time-of-flight (TOF) positron emission tomography/computed tomography for imaging of atherosclerotic plaque inflammation with fluorine-18 fluorodeoxyglucose in small and moving phantoms. Methods and Results: All images were reconstructed using a conventional algorithm without TOF (4 × 4 × 4 mm{sup 3} voxel size) and a high matrix algorithm with TOF (2 × 2 × 2 mm{sup 3} voxel size). Microsphere phantoms of 10, 7.9, 6.2, 5.0, and 4.0 mm diameters were acquired in 3-dimensional list-mode for 30 minutes. A heart phantom mimicking cardiac motion consisted of a hot spot simulating a plaque (φ 4 mm, φ 2 mm) on the outside of the left ventricle. In the microsphere and heart phantom study, visual discrimination, maximum activity, and target-to-background ratio using the high matrix algorithm with TOF were better than those using the conventional algorithm without TOF. Conclusion: The high matrix algorithm with TOF improves detection of small targets in phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography

Background: We compared two reconstruction algorisms and two cardiac functional evaluation software programs in terms of their accuracy for estimating ejection fraction (EF) of small hearts (SH). Methods: The study group consisted of 66 pediatric patients. Data were reconstructed using a filtered back projection (FBP) method without the resolution correction (RC) and an iterative method based on an ordered subset expectation maximization (OSEM) algorithm with the RC. EF was evaluated using two software programs of quantitative gated single-photon emission computed tomography (SPECT) (QGS) and cardioREPO. We compared the EF of gated myocardial perfusion SPECT to echocardiographic measurement (Echo). Results: Forty-eight of 66 patients had an end-systolic volume < 20 mL which was used as the criterion for being included in the SH group, and the SH effect led to an overestimation of EF. While significant differences were observed between Echo (66.9 ± 5.0%) and QGS-FBP without RC (76.9 ± 8.4%, P < .0001), QGS-OSEM with RC (76.6 ± 8.6%, P < .0001), and cardioREPO-FBP without RC (72.1 ± 10.0%, P = .0011), no significant difference was observed between Echo and cardioREPO-OSEM with RC (67.4 ± 6.1%) in SH group. Conclusions: In pediatric gated myocardial perfusion SPECT, the SH effect can be significantly reduced when an OSEM algorithm is used with RC in combination with the specific cardioREPO algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of renin–angiotensin–aldosterone system polymorphisms on myocardial perfusion: Correlations with myocardial single photon emission computed tomography-derived parameters

Background: Renin–angiotensin–aldosterone system (RAAS) has an important role in atherosclerosis. We investigated the effects of six RAAS gene polymorphisms on myocardial perfusion. Methods and Results: We examined 810 patients with known or suspected coronary artery disease (CAD) using stress–rest myocardial single-photon emission computed tomography. Summed stress score (SSS), summed rest score (SRS), summed difference score (SDS), transient ischemic dilation (TID), and lung/heart ratio (LHR) were recorded. The following gene polymorphisms were investigated: angiotensin-converting enzyme (ACE) insertion/deletion (I/D), angiotensinogen (AGT) M235T and T174M, angiotensin II type 1 receptor (AT1R) A1166C, renin (REN) C5312T, and angiotensin II type 2 receptor (AT2R) C3123A. The heterozygotes or homozygotes on ACE D allele were 7.54 times more likely to have abnormal SSS, while the AGT (T174M) heterozygotes were 5.19 times more likely to have abnormal SSS. The homozygotes of ACE D had significantly higher values on TID and LHR, while the AGT (T174M) heterozygotes had higher values on TID. The AT1R heterozygotes had greater odds for having SSS ≥ 3. The patients carried AT1R homozygosity of C allele had significantly higher values on TID, while heterozygotes of AT1R had significantly higher values on LHR. Conclusions: Among the polymorphisms investigated, ACE D allele had the strongest association with abnormal myocardial perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction

Background: The benefits of attenuation correction (AC) in technetium-99m myocardial perfusion imaging (MPI) have been well established. However, the value of thallium (Tl-201) AC and routine computed tomography AC (CTAC) were less well established. The aims of this study were to evaluate the diagnostic performance of thallium (Tl-201) MPI with additional CTAC and to determine which participants would benefit most. Methods and Results: A total of 108 consecutive patients who underwent Tl-201 MPI and received coronary angiography within 3 months were enrolled. Diagnostic performance was determined by sensitivity, specificity, and receiver operating characteristic curve analysis. Subgroup analyses were performed using gender and obesity. CTAC improved the area under the curve (0.84 vs. 0.77, P = 0.037 at patient level), primarily due to a significant improvement in specificity (0.78 vs. 0.57, P = 0.013) and no significant difference in sensitivity (0.79 vs. 0.82, P = 0.75). In subgroup analysis, CTAC was most helpful in obese subjects, men, and especially right coronary artery lesions. Conclusions: CTAC significantly improved diagnostic performance primarily by increasing the specificity, and the improvements were significantly greater in obese patients and male patients. These findings suggest that CTAC should be applied to Tl-201 MPI as routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is there a role for cardiac positron emission tomography in hypertrophic cardiomyopathy?

Coronary microvascular dysfunction and, its functional consequence, myocardial ischemia are common pathologic features in patients with hypertrophic cardiomyopathy (HCM). Both have been commonly invoked as potential triggers of and/or contributors to the underlying pathophysiological processes leading to heart failure, and malignant ventricular arrhythmias. Positron emission tomography (PET) with myocardial blood flow quantification provides a unique opportunity to evaluate the integrity and function of the coronary microcirculation in HCM. The purpose of the present review is to summarize all the pertinent literature and future perspectives of the role of PET in the evaluation and risk stratification of patients with HCM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pitfalls in the Diagnosis of Acute Pulmonary Embolism on Computed Tomography: Common Pathologic and Imaging Mimics

Purpose of Review: Acute pulmonary embolism (PE) is the third most-common acute cardiovascular disease in the United States. Nearly 900,000 new diagnoses are made each year, with 250,000 associated hospitalizations and up to 100,000 deaths (Palacio et al. in Semin Roentgenol 50(3):217–225, 2015; Metter et al. in Am J Roentgenol 208(3):489–494, 2017; Jaff et al. in Circulation 123(16):1788–830, 2011). Timely and accurate diagnosis of acute PE is crucial for the prevention of most deaths associated with PE, even more so than optimal medical therapy (Palacio et al. in Semin Roentgenol 50(3):217–225, 2015; Jaff et al. in Circulation 123(16):1788–830, 2011; Raja et al. in Ann Intern Med 163(9):701, 2015). Recent Findings: Computed tomography (CT) has emerged as the primary imaging modality used in the diagnosis of acute PE. Thus, radiologists play a key role in the correct diagnosis of acute PE, and must differentiate this diagnosis from other conditions that mimic the imaging findings of acute PE, as well as from artifacts associated with imaging techniques (Palacio et al. in Semin Roentgenol 50(3):217–225, 2015; Jaff et al. in Circulation 123(16):1788–830, 2011; Raja et al. in Ann Intern Med 163(9):701, 2015). Understanding how these diagnoses present on CT is necessary for improved patient care. Summary: This article will discuss the diagnosis of acute PE with CT, the diagnosis of diseases that may be mistaken for acute PE, and how to identify imaging artifacts that may be mistaken for an acute PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlations Between Spall Damage Mode Preference and Microstructure in Shocked Polycrystalline Copper: A 3-D X-Ray Tomography Study

Nondestructive characterization techniques are essential for maximizing the amount of high fidelity data obtained from post mortem mechanically tested materials, particularly for the complex experimental techniques used for shock loading. Polycrystalline copper samples of varying thermomechanical histories were shock loaded to induce incipient spall damage conditions via plate impacts at low pressures. Electron backscattering diffraction (EBSD) and 3-D X-ray tomography (XRT) were utilized to obtain microstructural and void volume data, respectively. Voids were fit to ellipsoids using their inertia tensors obtained from the 3-D XRT data, and the results compared to EBSD data. This, in turn, enabled establishing quantitative correlations between void shapes and preferential damage mode, either inter- or trans-granular, for each thermomechanical history. Greater than 60 % of voids present in heat-treated samples were spherical, indicative of transgranular damage preference. Greater than 90 % of voids present in as-received rolled samples were flat sheetlike voids or unsymmetrical oblate ellipsoids, indicative of intergranular and coalesced damage modes. Analyzing grain boundary damage statistics in conjunction with global damage mode distributions indicate that boundaries become less dominant as preferential void nucleation sites within the spall plane as the bulk strength of the material decreases from heat treatments.

Microstructure↗

Atom Probe Tomography Analysis of the Distribution of Rhenium in Nickel Alloys

Atom probe tomography (APT) is used to characterise the distributions of rhenium in a binary Ni-Re alloy and the nickel-based single-crystal CMSX-4 superalloy. A purpose-built algorithm is developed to quantify the size distribution of solute clusters, and applied to the APT datasets to critique the hypothesis that rhenium is prone to the formation of clusters in these systems. No evidence is found to indicate that rhenium forms solute clusters above the level expected from random fluctuations. In CMSX-4, enrichment of Re is detected in the matrix phase close to the matrix/precipitate ({gamma}/{gamma}{prime}) phase boundaries. Phase field modelling indicates that this is due to the migration of the {gamma}/{gamma}{prime} interface during cooling from the temperature of operation. Thus, neither clustering of rhenium nor interface enrichments can be the cause of the enhancement in high temperature mechanical properties conferred by rhenium alloying.

36 MATERIALS SCIENCE↗

Carbon concentration measurements by atom probe tomography in the ferritic phase of high-silicon steels

Current studies using atom probe tomography (APT) show that bainitic ferrite formed at low temperature contains more carbon than what is consistent with the paraequilibrium phase diagram. However, nanocrystalline bainitic ferrite exhibits a non-homogeneous distribution of carbon atoms in arrangements with specific compositions, i.e. Cottrell atmospheres, carbon clusters, and carbides, in most cases with a size of a few nanometers. The ferrite volume within a single platelet that is free of these carbon-enriched regions is extremely small. Proximity histograms can be compromised on the ferrite side, and a great deal of care should be taken to estimate the carbon content in regions of bainitic ferrite free from carbon agglomeration. For this purpose, APT measurements were first validated for the ferritic phase in a pearlitic sample and further performed for the bainitic ferrite matrix in high-silicon steels isothermally transformed between 200 °C and 350 °C. Additionally, results were compared with the carbon concentration values derived from X-ray diffraction (XRD) analyses considering a tetragonal lattice and previous APT studies. In conclusion, the present results reveal a strong disagreement between the carbon content values in the bainitic ferrite matrix as obtained by APT and those derived from XRD measurements. Those differences have been attributed to the development of carbon-clustered regions with an increased tetragonality in a carbon-depleted matrix.

36 MATERIALS SCIENCE↗

Atom probe tomography study of Fe-Ni-Al-Cr-Ti ferritic steels with hierarchically-structured precipitates

The ferritic Fe-Ni-Al-Cr-Mo steel (FBB8) has good creep properties up to 700 °C due to B2-NiAl nanoscale precipitates and its creep resistance can be further improved by additions of 2 or 4 wt.% Ti, as a result of sub-precipitates within the main precipitates. We report the hierarchical structure of the precipitates is studied in the light of phase separation via transmission electron microscopy (TEM) and atom probe tomography (APT). For FBB8-2Ti (with 2% Ti added) exhibiting B2-NiAl precipitates with L2 1 -Ni 2 AlTi sub-precipitates, APT analysis shows strong partitioning of Ni, Al and Ti from the ferritic matrix into the B2/L2 1 precipitates and, within the precipitates, partitioning of Ti and Fe within the L2 1 sub-precipitates. Based on the published pseudo-binary phase-diagram between (Ni,Fe)Al and (Ni,Fe)Ti, this hierarchical precipitate microstructure is discussed based on the known miscibility gap between the B2 and L2 1 phases, due to partitioning of Ti into the L2 1 phase and ordering of Al and Ti on the Al sub-lattice of the B2 structure. For FBB8-4Ti (with 4% Ti added), by contrast, the L2 1 precipitates exhibit bcc sub-precipitates rich in Fe and Cr, with a composition close to that of the matrix; the absence of the B2 structure is consistent with an increase of Ti and Fe concentrations, to 18.2 and 19.3 at.% respectively, as measured via APT, in the L2 1 precipitates.

36 MATERIALS SCIENCE↗

On spinodal decomposition in alnico - A transmission electron microscopy and atom probe tomography study

Here, alnico is a prime example of a finely tuned nanostructure whose magnetic properties are intimately connected to magnetic annealing (MA) during spinodal transformation and subsequent lower temperature annealing (draw) cycles. Using a combination of transmission electron microscopy and atom probe tomography, we show how these critical processing steps affect the local composition and nanostructure evolution with impact on magnetic properties. The nearly 2-fold increase of intrinsic coercivity (H ci ) during the draw cycle is not adequately explained by chemical refinement of the spinodal phases. Instead, increased Fe-Co phase (α 1 ) isolation, development of Cu-rich spheres/rods/blades and additional α 1 rod precipitation that occurs during the MA and draw, likely play a key role in Hci enhancement. Chemical ordering of the Al-Ni-phase (α 2 ) and formation of Ni-rich (α 3 ) may also contribute. Unraveling of the subtle effect of these nano-scaled features is crucial to understanding on how to improve shape anisotropy in alnico magnets.

36 MATERIALS SCIENCE↗

High throughput automated characterization of enamel microstructure using synchrotron tomography and optical flow imaging

The remarkable damage-tolerance of enamel has been attributed to its hierarchical microstructure and the organized bands of decussated rods. A thorough characterization of the microscale rod evolution within the enamel is needed to elucidate this complex structure. While prior efforts in this area have made use of single particle tracking to track a single rod evolution to various degrees of success, such a process can be both computationally and labor intensive, limited to the evolution path of a single rod, and is therefore prone to error from potentially tracking outliers. Particle image velocimetry (PIV) is a well-established algorithm to derive field information from image sequences for processes that are time-dependent, such as fluid flows and structural deformation. In this work, we demonstrate the use of PIV in extracting the full-field microstructural distribution of rods within the enamel. Further, enamel samples from a wild African lion were analyzed using high-energy synchrotron X-ray micro-tomography. Results from the PIV analysis provide sufficient full-field information to reconstruct the growth of individual rods that can potentially enable rapid analysis of complex microstructures from high resolution synchrotron datasets. Such information can serve as a template for designing damage-tolerant bioinspired structures for advanced manufacturing.

36 MATERIALS SCIENCE↗

In-situ x-ray computed tomography analysis of fracture mechanisms in ultrasonic additively manufactured Al-6061 alloy

The deformation and failure mechanisms in an ultrasonic additively manufactured Al-6061 alloy are studied using in-situ x-ray computed tomography during tensile deformation as well as ex-situ characterization with scanning electron microscopy. The role of pre-existing voids between the build layers on the failure mechanism is discussed with a focus on individual foil failures and void coalescence.

36 MATERIALS SCIENCE↗

Multiscale porosity characterization in additively manufactured polymer nanocomposites using micro-computed tomography

Extrusion-based additive manufacturing (AM) of polymer composites exhibits complex thermally driven phenomena that introduce severe discontinuities in the internal structure across length scales, especially voids or porosity. This study utilizes a high-throughput porosity characterization technique to analyze large datasets from numerous micro-computed tomography (mu CT) scans to capture the influence of AM print parameters on the size, shape, and location of porosity across multiple print layers (up to a few cm) on fused granular fabrication (FGF) printers. The materials investigated include nanocomposite formulations based on commercially relevant nylon-12 and polyether ketone ketone (PEKK) materials comprising nano- or micro- sized fillers. The estimated global porosity follows an inverse linear correlation against the bulk density of the printed samples. Increasing the extrusion multiplier (EM) and the nozzle temperature while decreasing the print speeds reduces the global porosity. Outlier analyses (local porosity morphology) show that faster print speeds and higher extrusion rates result in long, slender inter-layer voids, while lower nozzle temperatures lead to large, symmetrical, inter-bead voids (at the bead junction). Lack of active chamber temperature increases inter-layer and intra-bead voids with a two-fold increase in global porosity. Overall, the micro filler-reinforced composites exhibit higher global porosity than nanofiller-reinforced composites, which is attributed to the increased mismatch in the thermal expansion coefficient between the filler and the polymers used in the study.

36 MATERIALS SCIENCE↗

Quantum state tomography and fidelity estimation via Phaselift

Experiments of multi-photon entanglement have been performed by several groups. Obviously, an increase on the photon number for fidelity estimation and quantum state tomography causes a dramatic increase in the elements of the positive operator valued measures (POVMs), which results in a great consumption of time in measurements. In practice, we wish to obtain a good estimation of fidelity and quantum states through as few measurements as possible for multi-photon entanglement. Phaselift provides such a chance to estimate fidelity for entangling states based on less data. In this paper, we would like to show how the Phaselift works for six qubits in comparison to the data given by Pan’s group, i.e., we use a fraction of the data as input to estimate the rest of the data through the obtained density matrix, and thus goes beyond the simple fidelity analysis. The fidelity bound is also provided for general Schrödinger Cat state. Based on the fidelity bound, we propose an optimal measurement approach which could both reduce the copies and keep the fidelity bound gap small. The results demonstrate that the Phaselift can help decrease the measured elements of POVMs for six qubits. Our conclusion is based on the prior knowledge that a pure state is the target state prepared by experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗