Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Technology data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Fusion-Fission Research Facility (FFRF) as a Practical Step Toward Hybrids

The project of ASIPP (with PPPL participation), called FFRF, (R/a=4/1 m/m, Ipl=5 MA, Btor=4-6 T, PDT=50-100 MW, Pfission=80-4000 MW, 1 m thick blanket) is outlined. FFRF stands for the Fusion-Fission Research Facility with a unique fusion mission and a pioneering mission of merging fusion and fission for accumulation of design, experimental, and operational data for future hybrid applications. The design of FFRF will use as much as possible the EAST and ITER design experience. On the other hand, FFRF strongly relies on new, Lithium Wall Fusion plasma regimes, the development of which has already started in the US and China.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Activities of the OECD/NEA Expert Group on Assay Data for Spent Nuclear Fuel

Management of spent nuclear fuel is a key issue for many NEA member countries. In nuclear criticality safety, the decision of many countries to advance burnup credit as part of their licensing strategy has heightened recent interest in experimental data needed to validate computer codes used in burnup credit calculations. This paper discusses recent activities of an Expert Group on assay data, formed under the OECD/NEA/NSC/WPNCS (Working Party on Nuclear Criticality Safety) to help coordinate isotopic assay data activities and facilitate international collaboration between NEA member countries developing or implementing burnup credit methodologies. Recent activities of the Expert Group are described, focusing on the planned expansion of the Spent Fuel Isotopic Composition Database (SFCOMPO), and preparation of a state-of-the-art report on assay data that includes sections on recommended radiochemical analysis methods, techniques, and lessons learned from previous experiments.

07 ISOTOPE AND RADIATION SOURCES↗

The calculation of light element impurity (α, n) yield curves in a PuO 2 matrix and associated specific yield coefficients: Influence of the reaction cross sections

Most of the Pu separated from irradiated commercial nuclear fuel is stored as PuO 2 . The primary quantitative nondestructive measurement technique used to verify the amount of Pu in storage containers is passive neutron correlation counting. An important physical property of the oxide material is the ratio, α, of the rate of (α, n) neutrons produced inside the item to the rate of neutrons produced by spontaneous fission. This ratio influences the precision of the correlated counting method and affects the interpretation of the data because of how it changes both the primary total neutron production rate and the rate of induced fission events taking place inside the item. In addition to the main O(α, n) contribution, additional contributions come from α-particle interactions with light element impurities that are inevitably present. In this work, we calculate specific (α, n) yield coefficients, expressed in units of neutrons per second per gram of α-emitting nuclide per part per million by mass of the specified impurity element distributed in a pure PuO 2 matrix, for some key α-emitting actinides commonly present in reprocessed Pu ( 238–242 Pu+ 241 Am). These coefficients are directly applicable to nuclear safeguards verification work in which the α ratio is often calculated from the Pu-isotopic composition and chemical information obtained by other means. Further, they also provide a convenient up-to-date reference set against which values generated by other methods can be compared. Results are presented for impurities with atomic number from 3 to 17 inclusive, plus K and Fe. In most cases, these coefficients are not expected to change by more than 5%–10% at any time in the future. However, as new data become available, changes as large as 20% may be needed for some targets (e.g., F). The present yield calculations are limited by the general shortage of quality experimental total (α, n) reaction cross section data, which, together with unexplained variation between determinations, means that an objective and coherent evaluation is not possible. The situation is even less satisfactory for the partial differential cross section needed to calculate neutron spectra.

(𝛼, n) reactions↗

China’s Booming Plug-in Electric Vehicle Market—How Will It Continue?

The plug-in electric vehicle (PEV) is recognized as a pivotal component in transportation energy security and technology innovation in China. With government incentives and substantial capital investments, the Chinese PEV market has become one of the largest in the world. However, is this market boom ephemeral or will it be continuing? This chapter provides a general review of the Chinese PEV market mainly from the consumer per-spective, by summarizing the characteristics of the vehicle policies and consumer concerns in the PEV market in recent years. Moreover, it intro-duces detailed examples on how the policies, technologies, and infrastruc-ture shape the market. In addition to employing large amounts of reliable data from the China Automotive Technology and Research Center for the review, the authors also adopted a quantitative analysis tool—the New Energy and Oil Consumption Credits model—to project the potential in-dustrial impacts of the government policies in multiple scenarios. Based on the findings, it seems that the prosperity of the PEV market, incentivized by the government, will continue in the short run. The direct subsidies to PEV from the government will gradually phase out, and the supply-side push policies such as the dual-credit policy and other charging infrastruc-ture incentives will work as the invisible hand to force the automakers to invest more in the PEV segment. However, in the long run, innovation in PEV technology and business models, together with consumer acceptance will be the major factors that can sustain further market growth.

Ou, Shawn↗

Python and HPC for High Energy Physics Data Analyses

High level abstractions in Python that can utilize computing hardware well seem to be an attractive option for writing data reduction and analysis tasks. In this paper, we explore the features available in Python which are useful and efficient for end user analysis in High Energy Physics (HEP). A typical vertical slice of an HEP data analysis is somewhat fragmented: the state of the reduction/analysis process must be saved at certain stages to allow for selective reprocessing of only parts of a generally time-consuming workflow. Also, algorithms tend to to be modular because of the heterogeneous nature of most detectors and the need to analyze different parts of the detector separately before combining the information. This fragmentation causes difficulties for interactive data analysis, and as data sets increase in size and complexity (O10 TiB for a “small” neutrino experiment to the O10 PiB currently held by the CMS experiment at the LHC), data analysis methods traditional to the field must evolve to make optimum use of emerging HPC technologies and platforms. Mainstream big data tools, while suggesting a direction in terms of what can be done if an entire data set can be available across a system and analysed with high-level programming abstractions, are not designed with either scientific computing generally, or modern HPC platform features in particular, such as data caching levels, in mind. Our example HPC use case is a search for a new elementary particle which might explain the phenomenon known as “Dark Matter”. Here, using data from the CMS detector, we will use HDF5 as our input data format, and MPI with Python to implement our use case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2016 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

Environmental monitoring data are collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) within the Nevada National Security Site (NNSS). These data include direct radiation exposure, as well as radiation from the air, groundwater, meteorology, and vadose zone. This report summarizes the 2016 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports, developed by National Security Technologies, LLC Direct radiation monitoring data indicate exposure levels at the RWMSs are within the range of background levels measured at the NNSS. Slightly elevated exposure levels outside the Area 3 RWMS are attributed to nearby historical aboveground nuclear weapons tests. Air monitoring data show that tritium concentrations in water vapor and americium and plutonium concentrations in air particles are below Derived Concentration Standards for these radionuclides. Groundwater monitoring data indicate the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by RWMS operations. Results of groundwater analysis from wells around the Area 5 RWMS were all below established investigation levels. Leachate samples collected from the leachate collection system at the mixed low-level waste cell were below established contaminant regulatory limits. During 2016, precipitation at the Area 3 RWMS was 8% below average, and precipitation at the Area 5 RWMS was 8% above average. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward percolation of precipitation more effectively than evaporation as measured from the bare-soil weighing lysimeter. Vadose zone monitoring on Area 5 and Area 3 RWMS cell covers shows no evidence of precipitation percolating through the covers to the waste. Moisture from precipitation did not percolate below 150 centimeters (cm) (5 feet [ft]) in the vegetated final cover on the U-3ax/bl disposal unit at the Area 3 RWMS. During 2016, there was no drainage through 2.4 meters (8 ft) of soil as indicated from the Area 3 drainage lysimeters that received only natural precipitation. Forty-four percent of the applied precipitation and irrigation drained from the bare-soil drainage lysimeter, which received 3 times the natural precipitation. All 2016 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facilities’ PAs

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nevada National Security Site 2015 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

Environmental monitoring data are collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) within the Nevada National Security Site (NNSS). These data include direct radiation exposure, as well as radiation from the air, groundwater, meteorology, and vadose zone. This report summarizes the 2015 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports developed by National Security Technologies, LLC. Direct radiation monitoring data indicate exposure levels at the RWMSs are within the range of background levels measured at the NNSS. Slightly elevated exposure levels outside the Area 3 RWMS are attributed to nearby historical aboveground nuclear weapons tests. Air monitoring data show that tritium concentrations in water vapor and americium and plutonium concentrations in air particles are below Derived Concentration Standards for these radionuclides. Groundwater monitoring data indicate the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by RWMS operations. Results of groundwater analysis from wells around the Area 5 RWMS were all below established investigation levels. Leachate samples collected from the leachate collection system at the mixed low-level waste cell were below established contaminant regulatory limits. During 2015, precipitation at the Area 3 RWMS was 0.9% above average, and precipitation at the Area 5 RWMS was 25% above average. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward percolation of precipitation more effectively than evaporation as measured from the bare-soil weighing lysimeter. The 1.8 inches of precipitation in September reached the lowest sensors at 180 cm on the Cell 5S and 5N covers, however the sensors on the floor do not indicate any signs of the precipitation percolating thru the waste to the floor. Moisture from precipitation did not percolate below 150 centimeters (cm) (5 feet [ft]) in the vegetated final cover on the U-3ax/bl disposal unit at the Area 3 RWMS. A second remedial revegetation trial was done on the southern portion of the North Cover. In March 2015 it was determined that germination occurred on both the mulched and non-mulched treatments that were irrigated, but that no germination occurred on the non-irrigated treatments. By June the seedlings observed in March were gone, possibly grazed by rabbits which were observed inside the rabbit-proof fence. In August the entire area was sprayed with the herbicide glyphosate in an attempt to minimize weed seed production. During 2015, there was no drainage through 2.4 meters (8 ft) of soil as indicated from the Area 3 drainage lysimeters that received only natural precipitation. Thirty-one percent of the applied precipitation and irrigation drained from the bare-soil drainage lysimeter, which received 3 times the natural precipitation. All 2015 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facilities’ PAs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life-cycle Analysis of Conversion of Post-Use Plastic via Pyrolysis with the GREET Model

In this report, we present an updated LCA of the PTF pathway developed at Argonne. Benavides et al. (2017) analyzed the environmental impact of producing ultra-low sulfur (ULS) diesel fuel from PUP via pyrolysis (the most common PTF technology). We used the Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET®) model and collected data from eight PTF companies to assess the potential energy and environmental benefits associated with this technology (Argonne, 2020). We conducted a survey and aggregated the dataset based on the different responses, which included plant capacity, process yields, feedstock composition, material and energy inputs, and outputs, and other parameters. We calculated the energy, greenhouse gas (GHG) emissions, and water consumption of its intermediate product pyrolysis oil and final product PUP-derived ULS diesel and compared the results to those metrics for their conventional counterparts (crude naphtha and petroleum ULS diesel fuel).

10 SYNTHETIC FUELS↗

FY22 Grid Modernization & Energy Storage Program: Accomplishments & Impacts

Sandia’s Grid Modernization and Energy Storage program works to advance a national vision of a secure, resilient, and sustainable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY22 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Much of the material in this report comes from the separate 2022 Accomplishments Report compiled by our Energy Storage subprogram team, a cornerstone of our grid research and achievements. The Grid Energy Storage Program at Sandia is focused on making energy storage cost-effective through research and development (R&D) in new battery technologies, advanced power electronics and power conversion systems, improved safety and reliability for energy storage systems, analytical tools for the valuation of energy storage, and the validation of new energy storage technologies through demonstration projects. During the 2022 fiscal year, Sandia executed R&D work supported by the U.S. Department of Energy’s (DOE) Office of Electricity – Energy Storage Program under the leadership of Dr. Imre Gyuk. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by the DOE Office of Electricity and key programs within the DOE Office of Energy Efficiency and Renewable Energy. As we indicated in our report from last year, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Grid Security (EGS) FY24 Annual Report

Sandia’s Electric Grid Security program advances a national vision of a secure, resilient, and affordable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY24 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Key accomplishments in this report that support our strategy span our technical program areas and include: • The advancement of energy storage technologies, including creation of a national Long Duration Energy Storage Consortium; • Applications of artificial intelligence and machine learning to enhanced grid operations and planning; • Development of solid-state power conversion technologies and a new medium-voltage research lab; • New technologies to assess wildfire vulnerabilities and mitigate potential impacts; • Advanced applications of new cybersecurity technologies with industry partners; • Contributions to understanding the impacts of electromagnetic pulses and geomagnetic disturbances on grid components; and • Digital twin development for hybrid microgrids with multiple generators, storage, and loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY25 Electric Grid Security Annual Report

Sandia’s Electric Grid Security program advances a national vision of energy dominance and accessibility, while applying our national security -emphasis on ensuring of a secure, resilient, and affordable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY25 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Key accomplishments in this report that support our strategy span our technical program areas and include: • New open-source analytical tools for systems -level planning and optimization, including significant advances to the QuESt analytical environment; • Further advancement of artificial intelligence and machine learning to enhanced grid operations and planning as we rise to the challenge of new large loads; • Development of solid-state power conversion technologies and a new medium-voltage research lab; • New technologies to assess wildfire vulnerabilities and mitigate potential impacts; • Advanced applications of new cybersecurity technologies with industry partners; • Contributions to understanding the impacts of electromagnetic pulses and geomagnetic disturbances on grid components; and • Digital twin development for hybrid microgrids with multiple generators, storage, and loads. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by several offices within the U.S. Department of Energy (USDOE), including the Office of Electricity (OE); Cybersecurity, Energy Security, and Emergency Response (CESER); former offices such as the Office of Energy Efficiency and Renewable Energy (EERE), the Grid Deployment Office (GDO), the Office of Clean Energy Demonstrations (OCED), and other key programs at USDOE. As we continue to state in these annual reports, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent Leak Detection System

apability of underground carbon dioxide storage to confine and sustain injected CO2 for a very long time is the main concern for geologic CO2 sequestration. If a leakage from a geological CO2 sequestration site occurs, it is crucial to find the approximate amount and the location of the leak in order to implement proper remediation activity. An overwhelming majority of research and development for storage site monitoring has been concentrated on atmospheric, surface or near surface monitoring of the sequestered CO2. This study aims to monitor the integrity of CO2 storage at the reservoir level. This work proposes developing in-situ CO2 Monitoring and Verification technology based on the implementation of Permanent Down-hole Gauges (PDG) or “Smart Wells” along with Artificial Intelligence and Data Mining (AI&DM). The technology attempts to identify the characteristics of the CO2 leakage by de-convolving the pressure signals collected from Permanent Down-hole Gauges (PDG). Citronelle field, a saline aquifer reservoir, located in the U.S. was considered for this study. A reservoir simulation model for CO2 sequestration in the Citronelle field was developed and history matched. The presence of the PDGs were considered in the reservoir model at the injection well and an observation well. High frequency pressure data from sensors were collected based on different synthetic CO2 leakage scenarios in the model. Due to complexity of the pressure signal behaviors, a Machine Learning-based technology was introduced to build an Intelligent Leakage Detection System (ILDS). The ILDS was able to detect leakage characteristics in a short period of time (less than a day) demonstrating the capability of the system in quantifying leakage characteristics subject to complex rate behaviors. The performance of ILDS was examined under different conditions such as multiple well leakages, cap rock leakage, availability of an additional monitoring well, presence of pressure drift and noise in the pressure sensor and uncertainty in the reservoir model.

Mohaghegh, Shahab D.↗

Integration of transcriptomic and proteomic data identifies biological functions in cell populations from human infant lung

Systems biology uses computational approaches to integrate diverse data types to understand cell and organ behavior. Data derived from complementary technologies, for example transcriptomic and proteomic analyses, are providing new insights into development and disease. We compared mRNA and protein profiles from purified endothelial, epithelial, immune, and mesenchymal cells from normal human lung tissue. Signatures for each cell type were identified and compared at both mRNA and protein levels. Cell specific biological processes and pathways were predicted by analysis of concordant and discordant RNA-protein pairs. Cell clustering and gene set enrichment comparisons identified shared versus unique processes associated with transcriptomic and/or proteomic data. Clear cell-cell correlations between mRNA and protein data were obtained from each cell type. Approximately 40% of RNA-protein pairs were coherently expressed. While the correlation between RNA and their protein products was relatively low (approximately 0.4), cell specific signature genes involved in functional processes characteristic of each cell type, were more highly correlated with their protein products. Consistency of cell specific RNA-protein signatures indicated an essential framework for the function of each cell type. Visualization and reutilization of the protein and RNA profiles are supported by a new web application, "LungProteomics," which is incorporated into the LGEA web portal and freely accessible at (https://research.cchmc.org/pbge/lunggens/lungProteomics/human_sorted_profiles.html).

human lung, sorted cells, integrated omics, Transc↗

A Vision for Coupling Operation of US Fusion Facilities with HPC Systems and the Implications for Workflows and Data Management

The operation of large US Department of Energy (DOE) research facilities, like the DIII-D National Fusion Facility, results in the collection of complex multi-dimensional scientific datasets, both experimental and model-generated. In the future, it is envisioned that integrated data analysis coupled with large-scale high performance computing (HPC) simulations will be used to improve experimental planning and operation. Practically, massive data sets from these simulations provide the physics basis for generation of both reduced semi-analytic and machine-learning-based models. Storage of both HPC simulation datasets (generated from US DOE leadership computing facilities) and experimental datasets presents significant challenges. In this paper, we present a vision for a DOE-wide data management workflow that integrates US DOE fusion facilities with leadership computing facilities. Data persistence and long-term availability beyond the length of allocated projects is essential, particularly for verification and recalibration of artificial intelligence and machine learning (AI/ML) models. Because these data sets are often generated and shared among hundreds of users across multiple leadership computing facility centers, they would benefit from cross-platform accessibility, persistent identifiers (e.g. DOI, or digital object identifier), and provenance tracking. Here, the ability to handle different data access patterns suggests that a combination of low cost, high latency (e.g. for storing ML training sets) and high cost, low latency systems (e.g. for real-time, integrated machine control feedback) may be needed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying requisite changes to support modern maintenance practices - 294

Modern data science and processing require the use of modern maintenance records. With traditional record-keeping practices, the isolated nature of the data, as well as the presence of handwritten maintenance work orders and incomplete service logs, severely limit the amount of progress that can be made towards advanced condition-based maintenance. These condition-based methods of diagnostics, prognostics, and maintenance planning are a primary goal of next-generation plant operations and maintenance strategies, and are all dependent on the availability of quality plant data including maintenance data. By implementing changes to maintenance record-keeping practices, such as the use of a computerized maintenance management system, key data will become available to allow for implementation of state-of-the-art data analysis methods. This paper covers the benefits of utilizing digital record systems to increase maintenance data availability in terms of condition-based maintenance and asset management. The ability of these methods to enable state-of-the-art practices within industrial organizations is discussed to offer insight into ways that these improvements to operating strategy will contribute to improvements in world-class maintenance excellence. A discussion of the future of asset management in terms of data analytics, maintenance decision support, and data integration is provided to illustrate the changing landscape of plant management. The result is an examination of innovative maintenance strategies and discussion of challenges related to the future of asset management and implementing modern maintenance practices. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identification and Prioritization of Analysis Cases for Marine and Hydrokinetic Energy Risk Screening

In this report we describe the development of the Environmental Risk Evaluation System (ERES), a risk-informed analytical process for estimating the environmental risks associated with the construction and operation of marine and hydrokinetic energy generation projects. The development process consists of two main phases of analysis. In the first phase, preliminary risk analyses will take the form of screening studies in which key environmental impacts and the uncertainties that create risk are identified, leading to a better-focused characterization of the relevant environmental effects. Existence of critical data gaps will suggest areas in which specific modeling and/or data collection activities should take place. In the second phase, more detailed quantitative risk analyses will be conducted, with residual uncertainties providing the basis for recommending risk mitigation and monitoring activities. We also describe the process used for selecting three cases for fiscal year 2010 risk screening analysis using the ERES. A case is defined as a specific technology deployed in a particular location involving certain environmental receptors specific to that location. The three cases selected satisfy a number of desirable criteria: 1) they correspond to real projects whose deployment is likely to take place in the foreseeable future; 2) the technology developers are willing to share technology and project-related data; 3) the projects represent a diversity of technology-site-receptor characteristics; 4) the projects are of national interest, and 5) environmental effects data may be available for the projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗