Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Particle composition measurements for ultrafine particles collected at the EPCAPE Mount Soledad site from 04-27-2023 to 06-13-2023 using a Thermal Desorption Chemical Ionization Mass Spectrometer

The dataset contains particle composition data for both the positive and negative reagent ion modes of the Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS). The dataset is split into two directories: one for particles with diameters of 30 nm and the other for particles with diameters of less than 100 nm. The positive reagent ion mode uses H3O+ as the reagent ion, and ionization usually occurs through hydrogen addition. The negative mode uses O2- as the reagent ion. Negative mode ionization generally occurs through hydrogen abstraction, but O2- addition is also possible. Ion concentrations were normalized to total ion counts, and unknown ions were then removed from the data. The name of each ion fraction time series includes the mass to charge ratio and the chemical formula for the ion. Time is recorded in seconds since 1/1/1904. The time zone is UTC.

54 ENVIRONMENTAL SCIENCES↗

SCILLA Scanning Electrical Mobility Spectrometer (SEMS) airborne data

The Scanning Electrical Mobility Spectrometer (SEMS) provides measurements of bulk aerosol size distributions, which are crucial for studying aerosol-cloud interactions. The instrument sampled through two different inlets: an isokinetic inlet and a counter-flow virtual impactor (CVI) inlet. Data were collected to help improve climate and earth systems models, characterize atmospheric conditions, and validate satellite observations and climate simulations.

Scanning Electrical Mobility Spectrometer↗

SEQUOIA: A Newly Operating Chopper Spectrometer at the SNS

A fine resolution chopper spectrometer (SEQUOIA) recently received first neutronsat the SNS. The commissioning phase of the instrument is underway. SEQUOIA is designedto utilize neutrons of an incident energy (Ei) between 10-2000 meV. A monochromatic beamis provided on a sample, 20 m from the decoupled ambient temperature H2O moderator, byfiltering the white beam with a Fermi chopper located 18 m from the source. After interactingwith the sample, neutrons are detected by an array of 3He linear position sensitive tubes locatedon a vertical cylinder with a radius of 5.5 m. This contribution presents current results from thecommissioning experiments and compares SEQUOIA’s actual and predicted performance. Thesecommissioning experiments include characterization of the beam by monitors, determination ofthe chopper phase offsets, and runs with V and C4H2I2S. The predicted performance is providedby analytical calculations and Monte Carlo simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polarization Measurements in Photoproduction with CEBAF Large Acceptance Spectrometer

A significant part of the experimental program in Hall-B of the Jefferson Lab is dedicated to the studies of the structure of baryons. CEBAF Large Acceptance Spectrometer (CLAS), availability of circularly and linearly polarized photon beams and recent addition of polarized targets provides remarkable opportunity for single, double and in some cases triple polarization measurements in photoproduction. An overview of the experiments will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fission Physics and Cross Section Measurements with a Lead Slowing down Spectrometer

A Lead Slowing Down Spectrometer (LSDS) provides a high neutron flux environment that enables measurements of small samples ({approx}{mu}g) or samples with small cross sections (tens of {mu}b). The LSDS at Rensselaer Polytechnic Institute (RPI) was previously used for fission cross section measurements and for studies of methods for assay of used nuclear fuel. The effective energy range for the LSDS is 0.1 eV to 10 keV with energy resolution of about 35%. Two new LSDS applications were recently developed at RPI; the first enables simultaneous measurements of the fission cross section and fission fragment mass and energy distributions as a function of the incident neutron energy. The second enables measurements of the (n,{alpha}) and (n; p) cross sections for materials with a positive Q value for these reactions. Fission measurements of {sup 252}Cf, {sup 235}U, and {sup 239}Pu were completed and provide information on fission fragment and energy distributions in resonance clusters. Measurements of the (n,{alpha}) cross section for {sup 147,149}Sm were completed and compared to previously measured data. The new data indicate that the existing evaluations need to be adjusted.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Current Status and Future Plans for the General Antiparticle Spectrometer (GAPS)

We discuss current progress and future plans for the general antiparticle spectrometer experiment (GAPS). GAPS detects antideuterons through the X-rays and pions emitted during the deexcitation of exotic atoms formed when the antideuterons are slowed down and stopped in targets. GAPS provides an exceptionally sensitive means to detect cosmic-ray antideuterons. Cosmic-ray antideuterons can provide indirect evidence for the existence of dark matter in such form as neutralinos or Kaluza-Klein particles. We describe results of accelerator testing of GAPS prototypes, tentative design concepts for a flight GAPS detector, and near-term plans for flying a GAPS prototype on a balloon.

43 PARTICLE ACCELERATORS↗

Analysis of Spent Fuel Assay with a Lead Slowing Down Spectrometer

Assay of fissile materials in spent fuel that are produced or depleted during the operation of a reactor, is of paramount importance to nuclear materials accounting, verification of the reactor operation history, as well as for criticality considerations for storage. In order to prevent future proliferation following the spread of nuclear energy, we must develop accurate methods to assay large quantities of nuclear fuels. We analyze the potential of using a Lead Slowing Down Spectrometer for assaying spent fuel. We conclude that it is possible to design a system that will provide around 1% statistical precision in the determination of the 239 Pu, 241 Pu and 235 U concentrations in a PWR spent-fuel assembly, for intermediate-to-high burnup levels, using commercial neutron sources, and a system of 238 U threshold fission detectors. Pending further analysis of systematic errors, it is possible that missing pins can be detected, as can asymmetry in the fuel bundle.

07 ISOTOPE AND RADIATION SOURCES↗

Light Baryon Spectroscopy using the CLAS Spectrometer at Jefferson Laboratory

Baryons are complex systems of confined quarks and gluons and exhibit the characteristic spectra of excited states. The systematics of the baryon excitation spectrum is important to our understanding of the effective degrees of freedom underlying nucleon matter. High-energy electrons and photons are a remarkably clean probe of hadronic matter, providing a microscope for examining the nucleon and the strong nuclear force. Current experimental efforts with the CLAS spectrometer at Jefferson Laboratory utilize highly-polarized frozen-spin targets in combination with polarized photon beams. The status of the recent double-polarization experiments and some preliminary results are discussed in this contribution.

43 PARTICLE ACCELERATORS↗

ASIC for SDD-Based X-Ray Spectrometers

We present an application-specific integrated circuit (ASIC) for high-resolution x-ray spectrometers (XRS). The ASIC reads out signals from pixelated silicon drift detectors (SDDs). The pixel does not have an integrated field effect transistor (FET); rather, readout is accomplished by wire-bonding the anodes to the inputs of the ASIC. The ASIC dissipates 32 mW, and offers 16 channels of low-noise charge amplification, high-order shaping with baseline stabilization, discrimination, a novel pile-up rejector, and peak detection with an analog memory. The readout is sparse and based on custom low-power tristatable low-voltage differential signaling (LPT-LVDS). A unit of 64 SDD pixels, read out by four ASICs, covers an area of 12.8 cm{sup 2} and dissipates with the sensor biased about 15 mW/cm{sup 2}. As a tile-based system, the 64-pixel units cover a large detection area. Our preliminary measurements at -44 C show a FWHM of 145 eV at the 5.9 keV peak of a {sup 55}Fe source, and less than 80 eV on a test-pulse line at 200 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact proton spectrometers for measurements of shock

The compact Wedge Range Filter (WRF) proton spectrometer was developed for OMEGA and transferred to the National Ignition Facility (NIF) as a National Ignition Campaign (NIC) diagnostic. The WRF measures the spectrum of protons from D-{sup 3}He reactions in tuning-campaign implosions containing D and {sup 3}He gas; in this work we report on the first proton spectroscopy measurement on the NIF using WRFs. The energy downshift of the 14.7-MeV proton is directly related to the total {rho}R through the plasma stopping power. Additionally, the shock proton yield is measured, which is a metric of the final merged shock strength.

42 ENGINEERING↗

Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

42 ENGINEERING↗

Electro-optic Phase Grating Streak Spectrometer

The electro-optic phase grating streak spectrometer (EOPGSS) generates a time-resolved spectra equivalent to that obtained with a conventional spectrometer/streak camera combination, but without using a streak camera (by far the more expensive and problematic component of the conventional system). The EOPGSS is based on a phase, rather than an amplitude grating. Further, this grating is fabricated of electro-optic material such as, for example, KD*P, by either etching grooves into an E-O slab, or by depositing lines of the E-O material onto an optical flat. An electric field normal to the grating alters the material’s index of refraction and thus affects a shift (in angle) of the output spectrum. Ramping the voltage streaks the spectrum correspondingly. The streak and dispersion directions are the same, so a second (static, conventional) grating disperses the spectrum in the orthogonal direction to prevent different wavelengths from “overwriting” each other. Because the streaking is done by the grating, the streaked output spectrum is recorded with a time-integrating device, such as a CCD. System model, typical design, and performance expectations will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning Mobility Particle Sizer-Portable Optical Particle Spectrometer Intercomparison Field Campaign Report

A portable optical particle spectrometer (POPS) has recently been acquired by the United Kingdom Meteorological (UK Met) Office with the intention of mounting it on an unmanned aerial vehicle (UAV) for atmospheric aerosol research. Before conducting research with the new instrument, an intercomparison has been conducted to test the performance of the POPS against a scanning mobility particle sizer (SMPS) — a veteran and well-characterized particle sizer. As part of the Cloud-Aerosol-Radiation Interactions and Forcing (CLARIFY) campaign, the POPS was installed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility mobile site on Ascension Island in the South Atlantic Ocean, alongside an ARM-operated SMPS. Both instruments sampled continuously from 20 August to 9 September, 2017. The SMPS and the POPS were connected to a common aerosol inlet; however, in the case of the SMPS, the sample air was dried before it entered the instrument. The POPS is a miniaturized optical particle counter designed specifically for use in balloon and UAV applications. The instrument is fully described in Goa et al. (2016) and so is only briefly described here. The POPS samples particles by drawing air through an inlet tube into an optical chamber, where it is illuminated by a 405nm laser. A sheath air flow is used to focus the sample air into the center of the laser beam, and the sample flow is maintained at a near-constant rate by an onboard pump. Side-scattered laser light is reflected into a photomultiplier tube by a hemispherical mirror, and the signal amplitude recorded by a data logger. Individual particle sizes are then inferred by comparing the recorded signal amplitudes to scattering amplitudes calculated using Mie theory. In common with other optical particle counters, the POPS size distributions are influenced by the refractive index used in the Mie calculations. The POPS is calibrated by the manufacturers (Handix Scientific) using latex spheres, with a refractive index (RI) of 1.615+0.001i. Sampling aerosols with a different refractive index, particularly if they are strongly absorbing, will result in significant uncertainties/errors in the particle size distributions (PSDs). We have therefore used scattering amplitude curves (calculated by Handix) for more absorbing aerosols, with an RI of 1.54+0.027i, which is expected to be more representative of the biomass-burning aerosol particles sampled at the ARM site during the CLARIFY campaign. In contrast to the POPS, the SMPS measures particle size using the differential mobility technique after applying an electrical charge to aerosol particles. The method is independent of the refractive index (Ruzer 2013).

CLARIFY, portable optical particle spectrometer, s↗

Design of the Opacity Spectrometer for opacity measurements at the National Ignition Facility

calculating opacity, of importance for modeling stellar interiors. An effort is being made to reproduce these results at the National Ignition Facility (NIF). These experiments require a new X-ray opacity spectrometer (OpSpec) spanning 540 eV – 2100 eV with a resolving power E/ΔE > 700. The design of the OpSpec is presented. Photometric calculations based on expected opacity data are also presented. First use on NIF is expected in September 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative Gamma Ray Spectrometer Detection Systems for Conducting Scanning Surveys on Challenging Terrain - 13583

The Santa Susana Field Laboratory located near Simi Valley, California was investigated to determine the nature and extent of gamma radiation anomalies. The primary objective was to conduct gamma scanning surveys over 100 percent of the approximately 1,906,000 square meters (471 acre) project site with the most sensitive detection system possible. The site had challenging topography that was not conducive to traditional gamma scanning detection systems. Terrain slope varied from horizontal to 48 degrees and the ground surface ranged from flat, grassy meadows to steep, rocky hillsides. In addition, the site was home to many protected endangered plant and animal species, and archaeologically significant sites that required minimal to no disturbance of the ground surface. Therefore, four innovative and unique gamma ray spectrometer detection systems were designed and constructed to successfully conduct gamma scanning surveys of approximately 1,076,000 square meters (266 acres) of the site. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗