Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

The Scientific Importance of Returning Airfall Dust as a Part of Mars Sample Return (MSR)

Dust transported in the martian atmosphere is of intrinsic scientific interest and has relevance for the planning of human missions in the future. The MSR Campaign, as currently designed, presents an important opportunity to return serendipitous, airfall dust. The tubes containing samples collected by the Perseverance rover would be placed in cache depots on the martian surface perhaps as early as 2023–24 for recovery by a subsequent mission no earlier than 2028–29, and possibly as late as 2030–31. Thus, the sample tube surfaces could passively collect dust for multiple years. This dust is deemed to be exceptionally valuable as it would inform our knowledge and understanding of Mars' global mineralogy, surface processes, surface-atmosphere interactions, and atmospheric circulation. Preliminary calculations suggest that the total mass of such dust on a full set of tubes could be as much as 100 mg and, therefore, sufficient for many types of laboratory analyses. Two planning steps would optimize our ability to take advantage of this opportunity: (1) the dust-covered sample tubes should be loaded into the Orbiting Sample container (OS) with minimal cleaning and (2) the capability to recover this dust early in the workflow within an MSR Sample Receiving Facility (SRF) would need to be established. A further opportunity to advance dust/atmospheric science using MSR, depending upon the design of the MSR Campaign elements, may lie with direct sampling and the return of airborne dust.

Monica M. Grady↗

Requesting Antarctic Meteorite Samples for Research

The U.S. Antarctic meteorite program began in the 1970’s and has provided more than 24,000 samples. The program is based on a three agency agreement between NASA, the National Science Foundation, and the Smithsonian Institution. The collection, stored at the Johnson Space Center and the Smithsonian, is one of the largest collections of meteorites in the world and features samples from the moon, Mars, asteroids, and material from the early solar system. A brief overview of the collection shows it contains 92.2% ordinary chondrites (7205 H, 9126 L, 3890 LL, 146 enstatite, 30 R chondrites, 3.2% (973) carbonaceous chondrites, 3.7% (560) achondrites (1.7% HED), 118 irons, 27 pallasites, 41 mesosiderites, as well as many puzzling, ungrouped meteorites. JSC has sent splits of over 20,000 meteorite samples to more than 500 scientists around the world since 1977. After the meteorites are collected in Antarctica, they are shipped frozen to JSC in Houston, TX, arriving in April following the field season. The Astromaterials Curation Office at JSC is responsible for: - providing supplies and tools for the field team. - receiving the frozen meteorites. - staging: repackaging and changing the samples’ field identification numbers with official names. - submitting the names to the Nomenclature Committee of the Meteoritical Society for approval as new meteorites. - providing storage and handling of the meteorites in a class 10,000 clean room. - initial processing: weighing, measuring, describing, and photographing the sample and providing a chip for classification to the Smithsonian Institution staff. - the issuing of two newsletters per year, announcing hundreds of new meteorites. - the handling of requests from the scientific community and the allocation of those requests that are approved. - making petrographic thin and thick sections for the JSC library and scientific investigators. - maintaining the meteorite database with more than 76,000 sample splits.

C.E. Satterwhite↗

Investigating Amino Acid Heterogeneity in Milligram-Scale Samples of the Murchison CM2 Carbonaceous Chondrite

Analyses of different aliquots of the Tagish Lake meteorite have resulted in amino acid abundance variations of an order of magnitude or more, even when performed using the same techniques, by the same personnel, in the same laboratories (e.g., Simkus et al. 2019). Up to ~five-fold variations have been observed for specific amino acids in different samples of the same meteorite, such as α aminoisobutryic acid (AIB) in Murchison. These variations are often attributed differing sample composition or differing alteration history, neither of which is mutually exclusive. Distinguishing between these two explanations is challenging and time consuming, requiring detailed mineralogical analyses to be performed in conjunction with high precision organics analysis. The potential for innate sample-level heterogeneity presents a significant complication when parsing the effects of different processes or conditions during preparation of meteorite samples for analysis, as differences in organic yields or abundances could be due to differences in laboratory processing or differences among the samples themselves. In this work, we investigated the degree of innate organic heterogeneity present in a single ~250 mg chip of divided into 21 samples.

A. S. Burton↗

Improved Aerothermal Reliability Analysis Enabled by the Mars Sample Return Earth Entry System Aerothermal Database

The Mars Sample Return (MSR) campaign is a series of missions designed to retrieve Martian rock and soil samples for detailed study on Earth. The campaign is split into three primary phases: sample collection with the Mars2020 rover, retrieval with the Sample Return Lander (SRL) and Mars Ascent Vehicle (MAV), and then return to Earth with the Earth Return Orbiter (ERO) and Capture, Containment, and Return System (CCRS) [1]. The final sequence in the Earth return phase is the delivery and entry of the Earth Entry System (EES) sample return capsule. Due to unprecedented planetary protection concerns, the sample return capsule is subject to strict reliability requirements. To this end, the MSR-EES aerothermal team has implemented a flexible aerothermal database architecture capable of integration with state-of-the-art trajectory codes to provide a more rigorous aerothermal reliability analysis. The EES database enables the generation of environments at any location on the heatshield and can incorporate trajectory uncertainties to both statistically quantify aerothermal environments for arcjet testing and produce material response boundary conditions to rigorously select thermal protection system (TPS) sizing environments. This poster will not discuss the fundamental modeling assumptions included in the database, and will instead focus on the downstream reliability analyses that can be performed with a database of this architecture.

MSR-EES↗

Nanoscale Mineralogy of Bennu Samples Returned by OSIRIS-REx

The OSIRIS-REx spacecraft returned regolith samples from asteroid Bennu and an initial sample was allocated for quick-look (QL) analyses. These QL particles were recovered from the avionics deck of the sample canister and were used to test the hypothesis that this dust is broadly representative of the bulk sample. The QL sample analyses showed that the materials are dominated by hydrated silicates, sulfides, magnetite, phosphates, and abundant organic matter, in addition to other minor/trace phases. Here we report our preliminary transmission electron microscope (TEM) observations for the nanoscale mineralogy of Bennu samples.

L P Keller↗

Analyses of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4) Contamination Samples

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of environmental effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center developed a series of experiments that were flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). Recently, four Glenn experiments with 365 flight samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Each of these experiments included passive contamination witness samples in each flight direction for post-flight molecular contamination analyses. A total of 13 contamination flight samples were flown. The post-flight analyses of the PCE 1-4 contamination samples include X-ray Photoelectron Spectroscopy (XPS) analyses (surface and ion sputter depth analyses) and optical properties (total reflectance, total transmittance and solar absorptance). This paper provides results of post-flight analyses of the PCE 1-4 contamination samples and their corresponding control samples. Knowledge of on-orbit contamination is important for the PCE 1-4 flight data interpretation.

Atomic Oxygen↗

Preliminary Design of Robotic Control Software for Mars Sample Return - Capture, Containment, and Return System

The Mars Sample Return (MSR) campaign aims to acquire and return to Earth a set of Mars samples for investigation in terrestrial laboratories. Mars 2020 has collected an adequate number of samples and deposited them in sealed sample tubes at a designated Martian depot. Sample tubes will be placed in cylindrical containers called Orbiting Samples (OS) by the Perseverance Rover, and later brought to Earth by the Earth Return Orbiter (ERO) and the MSR - Capture, Containment, and Return System (CCRS). Robot Software (RSW) is a set of software processes for commanding and monitoring the avionics that controls robotic mechanisms designed to sterilize and install OS into Earth Entry System (EES) for return to Earth. This paper describes a preliminary design of RSW including motion modes, architecture, and finite state machine. Additionally, software engineering procedures and testing of RSW is provided. A preliminary performance analysis is presented and the paper concludes with future work and a discussion of design decisions.

MSR↗

The Nature of Space Weathering in Samples From Asteroid (162173) Ryugu Revealed By Coordinated Analysis

Space weathering, driven primarily by micrometeorite bombardment and solar wind ion irradiation, alters the morphology, microstructure, and chemistry of the surface regolith on airless bodies. The accumulation of microstructural and chemical space weathering features, including melt deposits, amorphous rims, and nanophase iron-bearing particles (npFe), are associated with alterations of the spectral properties of the regolith. In particular, space weathering changes the spectral slope and reflectance of surface materials, and causes the attenuation of characteristic absorption bands in the visible to near-infrared wave-lengths, as well as a shift towards longer wavelengths of the Christiansen feature (CF)in thermal infrared spectra. Previous studies of space weathering characteristics have focused on siliceous bodies like the Moon and S-type asteroid Itokawa. However, observations of asteroid Ryugu by the JAXA Hayabusa2 spacecraft and subsequent analyses of returned samples revealed carbonaceous and hydrated materials. These samples provided our first opportunity to constrain the effects of space weathering processes on primitive, C-type asteroids. Analyses of returned samples to understand the space weathering of carbonaceous materials are important for accurately interpreting remote sensing observations of carbonaceous asteroids. In addition, the analysis of Hayabusa2 samples from Ryugu paved the way for the analysis of samples from the asteroid Bennu, re-turned by the NASA OSIRIS-REx mission. As space weathering impacts the microstructure, chemistry, and spectral characteristics of asteroidal surfaces, here we report the results of a coordinated analytical study of the micro-and nano-scale signatures of space weathering in samples returned from Ryugu.

L E Melendez↗

Preservation of Previously Unsampled Primordial Isotopic Components in Ryugu and Bennu Samples

Ivuna-type (CI) carbonaceous chondrites are primitive meteorites whose relative elemental abundances closely match the solar photosphere 1 , making them critical benchmarks for the bulk chemical and isotopic composition of the planet-forming disk. Recent sample-return missions to Ryugu 2 and Bennu 3 have enabled direct laboratory analysis of these rubble-pile CI-like asteroids 4 , formed from the reaccumulated fragments of once-larger parent bodies. As such, they may retain a broader spectrum of primordial nucleosynthetic components than is preserved in known meteorites. Here, we report the nucleosynthetic compositions of silicon (μ 30 Si), magnesium (μ 26 Mg*), and iron (μ 54 Fe), three of the four most abundant planet-building elements, in samples from Ryugu and Bennu, along with the newly discovered Oued Chebeika 002 CI chondrite 5 . In contrast to the isotopic homogeneity of CI chondrites, Ryugu and Bennu preserve resolvable μ 26 Mg* and μ 30 Si heterogeneity, revealing μ 26 Mg*- and μ 30 Si-rich nucleosynthetic components not sampled in meteorites. These components may reflect the preservation of previously unsampled primordial isotopic signals, prior to thermal processing 6,7 and late infall of primordial molecular cloud material to the outer disk 8,9 . Additionally, Ryugu particle C0002 exhibits a μ 26 Mg*-poor and μ 54 Cr-rich signature, consistent with incorporation of presolar material from massive supernovae 10,11 . Ryugu and Bennu samples define one end of a μ 54 Fe–μ 30 Si array among carbonaceous asteroid materials 9 , suggesting that the isotopic compositions of these asteroidal materials reflect mixing between early disk isotopic components identified in this study and material derived from the outermost disk 9 . This observation demonstrates that materials with solar chemical abundances can nonetheless exhibit markedly distinct nucleosynthetic signatures. Thus, Ryugu and Bennu samples are critical records of nucleosynthetic diversity among carbonaceous asteroids and underscore the value of sample-return missions in accessing primitive isotopic signatures absent from meteorite collections.

Martin Bizzarro↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

High efficiency environmental sampling with rapidly cured peelable coatings

A rapidly curable liquid gel for collecting an analyte from a sampling surface includes a polymer precursor mixture including a monomer and/or an oligomer; and an additive to enhance extraction of the analyte from the sampling surface. A kit for collecting an analyte from a sampling surface may include the rapidly curable liquid gel and a portable device for rapidly curing the gel. The rapidly curable liquid gel is cured to thereby form a peelable sampling film, and the sampling film is removed from the sampling surface, thereby collecting the analyte. In one embodiment, the rapidly curable liquid gel is UV-curable, the polymer precursor mixture further includes a photoinitiator compound, and the portable device includes a UV light source configured to emit UV light of a wavelength range absorbed by the photoinitiator compound.

Henzl, Vladimir↗

C-SAW: a framework for graph sampling and random walk on GPUs

Many applications require to learn, mine, analyze and visualize large-scale graphs. These graphs are often too large to be addressed efficiently using conventional graph processing technologies. Fortunately, recent research efforts find out graph sampling and random walk, which significantly reduce the size of original graphs, can benefit the tasks of learning, mining, analyzing and visualizing large graphs by capturing the desirable graph properties. This paper introduces C-SAW, the first framework that accelerates Sampling and Random Walk framework on GPUs. Particularly, C-SAW makes three contributions: First, our framework provides a generic API which allows users to implement a wide range of sampling and random walk algorithms with ease. Second, offloading this framework on GPU, we introduce warp-centric parallel selection, and two novel optimizations for collision migration. Third, towards supporting graphs that exceed the GPU memory capacity, we introduce efficient data transfer optimizations for out-of-memory and multi-GPU sampling, such as workload-aware scheduling and batched multi-instance sampling. Taken together, our framework constantly outperforms the state of the art projects in addition to the capability of supporting a wide range of sampling and random walk algorithms.

97 MATHEMATICS AND COMPUTING↗

Humidified sample preparation station for serial crystallography

Humidified sample preparation station for serial crystallography according to one embodiment is a humidified enclosure that delivers relative humidities above 95% and preferably above 97% in standard operation, and that can allow microscope observation of samples within. Humidified sample preparation station for serial crystallography can be used for preparation of protein crystal samples for examination using X-rays and for protein structure determination by X-ray crystallography, involving addition of liquid to the sample and removal of liquid from the sample using vacuum or suction.

Jayne, Richard↗

High efficiency active environmental sampling of chemical traces

A method of sample collection includes collecting an analyte from a sampling surface using a rapidly curable liquid gel comprising one or more metal particles; co-aggregating the one or more metal particles from the rapidly curable liquid gel and the analyte from the sampling surface; and rapidly curing the rapidly curable liquid gel. The composition and sample preparation conditions may facilitate improved collection efficiency of analytes during environmental and forensic evidence sampling. In addition, the composition and sample preparation conditions may facilitate enhanced detection and identification of the analyte using e.g., Surface Enhanced Raman Spectrometry (SERS).

Junghans, Ann↗

Apparatus and methods for sample analysis with multi-gradient microfluidics

A device for analyzing biological samples comprises first, second, third, and fourth layers. The first layer comprises a sample chamber in which a sample is positioned. The second layer comprises first, second, and third channels. A third, porous layer is positioned between the first layer and the second layer. A fourth layer composed of a substantially liquid-impermeable material is positioned between the second layer and the third layer. The fourth layer includes first and second pass-through channels that are aligned with the first and second channel, respectively. Fluids that flow in the first and second channels pass through the pass-through channels and diffuse into the sample chamber, establishing a chemical concentration gradient therein. A gas in the sample chamber can diffuse through the third and fourth layers and interact with a fluid flowing in the third channel, establishing a gas concentration gradient in the sample chamber.

Kim, Peter Wonhee↗

Analysis Of Fracture Location on Tensile Graphite Samples

The main standard for testing the ultimate tensile strength of graphite is ASTM C749. Commercial entities have raised concerns about samples breaking outside of the gauge section, particularly in the radius or head of the sample. When this occurs, the data gathered from the samples is unusable and increases the cost of testing as more samples will need to be machined. This study investigates the locations and frequency of sample breakage for four different grades of graphite using a custom-made measurement scale. The four grades include two fine-grain (2114 and IG-110) and two medium/coarse-grain (NBG-17 and PCEA). Our results show that fine-grain grades are more susceptible to breaking outside the gauge section, with almost 30% of the samples from grade 2114 breaking outside this region. Additionally, the radius being too small causes stress concentrations near the ends of the gauge section resulting in a bimodal distribution of the fracture locations.

36 - MATERIALS SCIENCE↗

An interoperable implementation of collective‐variable based enhanced sampling methods in extended phase space within the OpenMM package

Collective variable (CV)-based enhanced sampling techniques are widely used today for accelerating barrier-crossing events in molecular simulations. A class of these methods, which includes temperature accelerated molecular dynamics (TAMD)/driven-adiabatic free energy dynamics (d-AFED), unified free energy dynamics (UFED), and temperature accelerated sliced sampling (TASS), uses an extended variable formalism to achieve quick exploration of conformational space. These techniques are powerful, as they enhance the sampling of a large number of CVs simultaneously compared to other techniques. Extended variables are kept at a much higher temperature than the physical temperature by ensuring adiabatic separation between the extended and physical subsystems and employing rigorous thermostatting. Here, in this work, we present a computational platform to perform extended phase space enhanced sampling simulations using the open-source molecular dynamics engine OpenMM. The implementation allows users to have interoperability of sampling techniques, as well as employ state-of-the-art thermostats and multiple time-stepping. This work also presents protocols for determining the critical parameters and procedures for reconstructing high-dimensional free energy surfaces. As a demonstration, we present simulation results on the high dimensional conformational landscapes of the alanine tripeptide in vacuo, tetra-N-methylglycine (tetra-sarcosine) peptoid in implicit solvent, and the Trp-cage mini protein in explicit water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗