Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Trace metal analysis by laser ablation-inductively coupled plasmamass spectrometry and x-ray K-edge densitometry of forensic samples

This dissertation describes a variety of studies on the determination of trace elements in samples with forensic importance. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the trace element composition of numerous lipstick samples. Lipstick samples were determined to be homogeneous. Most lipstick samples of similar colors were readily distinguishable at a 95% confidence interval based on trace element composition. Numerous strands of a multi-strand speaker cable were analyzed by LA-ICP-MS. The strands in this study are spatially heterogeneous in trace element composition. In actual forensic applications, the possibility of spatial heterogeneity must be considered, especially in cases where only small samples (e.g., copper wire fragments after an explosion) are available. The effects of many unpredictable variables, such as weather, temperature, and human activity, on the retention of gunshot residue (GSR) around projectile wounds were assessed with LAICP- MS. Skin samples around gunshot and stab wounds and larvae feeding in and around the wounds on decomposing pig carcasses were analyzed for elements consistent with GSR (Sb, Pb, Ba, and Cu). These elements were detected at higher levels in skin and larvae samples around the gunshot wounds compared to the stab wounds for an extended period of time throughout decomposition in both a winter and summer study. After decomposition, radiographic images of the pig bones containing possible damage from bullets revealed metallic particles embedded within a number of bones. Metallic particles within the bones were analyzed with x-ray, K-edge densitometry and determined to contain lead, indicating that bullet residue can be retained throughout decomposition and detected within bones containing projectile trauma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data Validation Package - July 2016 Groundwater Sampling at the Gunnison, Colorado, Disposal Site

Groundwater sampling at the Gunnison, Colorado, Disposal Site is conducted every 5 years to monitor disposal cell performance. During this event, samples were collected from eight monitoring wells as specified in the 1997 Long-Term Surveillance Plan for the Gunnison, Colorado, Disposal Site. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and­ analysis-plan-us-department-energy-office-legacy-management-sites). Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0723. Water levels were measured at all monitoring wells that were sampled and seven additional wells. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that require additional action or follow-up.

54 ENVIRONMENTAL SCIENCES↗

Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Generation Flask Sampling Technology Final Report

Scientists are turning their focus to the Arctic, site of one of the strongest climate change signals. A new generation of technologies is required to function within that harsh environment, chart evolution of its trace gases and provide new kinds of information for models of the atmosphere. Our response to the solicitation tracks how global atmospheric monitoring was launched more than a half century ago; namely, acquisition of discrete samples of air by flask and subsequent analysis in the laboratory. AOS is proposing to develop a new generation of flask sampling technology. It will enable the new Arctic programs to begin with objective high density sampling of the atmosphere by UAS. The Phase I program will build the prototype flask technology and show that it can acquire and store mol fractions of CH4 and CO2 and value of δ13C with good fidelity. A CAD model will be produced for the entire platform including a package with 100 flasks and the airframe with auto-pilot, electronic propulsion and ground-to-air communications. A mobile flask analysis station will be prototyped in Phase I and designed to final form in Phase II. It expends very small sample per analysis and will interface directly to the flask package integrated permanently into the UAS fuselage. Commercial Applications and Other Benefits: • The New Generation Flask Sampling Technology able to provide a hundred or more samples of air per UAS mission. • A mobile analysis station expending far less sample than the existing ones and small enough to be stationed at the remote sites of Arctic operations. • A new form of validation for continuous trace gas observations from all platforms including the small UAS. • Further demonstration to potential customers of the AOS capabilities to invent, build, deploy and exploit entire platforms for observations of Earth’s atmosphere and ocean. Key Words: Flask Sampler, Mobile Analysis Station, Trace Gas, CO2, CH4, δC13, UAS, Baseline Airborne Observatory, Arctic, Climate Change. Summary for Members of Congress: The air, land and sea of the Arctic combine to produce a large climate change signal. AOS is proposing to develop unmanned airborne technologies able to begin prompt, objective observations of the signal’s atmospheric component.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a Class of Simple and Effective Uncertainty Methods for Sparse Samples of Random Variables and Functions

When very few samples of a random quantity are available from a source distribution of unknown shape, it is usually not possible to accurately infer the exact distribution from which the data samples come. Under-estimation of important quantities such as response variance and failure probabilities can result. For many engineering purposes, including design and risk analysis, we attempt to avoid under-estimation with a strategy to conservatively estimate (bound) these types of quantities -- without being overly conservative -- when only a few samples of a random quantity are available from model predictions or replicate experiments. This report examines a class of related sparse-data uncertainty representation and inference approaches that are relatively simple, inexpensive, and effective. Tradeoffs between the methods' conservatism, reliability, and risk versus number of data samples (cost) are quantified with multi-attribute metrics use d to assess method performance for conservative estimation of two representative quantities: central 95% of response; and 10 -4 probability of exceeding a response threshold in a tail of the distribution. Each method's performance is characterized with 10,000 random trials on a large number of diverse and challenging distributions. The best method and number of samples to use in a given circumstance depends on the uncertainty quantity to be estimated, the PDF character, and the desired reliability of bounding the true value. On the basis of this large data base and study, a strategy is proposed for selecting the method and number of samples for attaining reasonable credibility levels in bounding these types of quantities when sparse samples of random variables or functions are available from experiments or simulations.

97 MATHEMATICS AND COMPUTING↗

Verifying mixing in dilution tunnels How to ensure cookstove emissions samples are unbiased

A well-mixed diluted sample is essential for unbiased measurement of cookstove emissions. Most cookstove testing labs employ a dilution tunnel, also referred to as a “duct,” to mix clean dilution air with cookstove emissions before sampling. It is important that the emissions be well-mixed and unbiased at the sampling port so that instruments can take representative samples of the emission plume. Some groups have employed mixing baffles to ensure the gaseous and aerosol emissions from cookstoves are well-mixed before reaching the sampling location [2, 4]. The goal of these baffles is to to dilute and mix the emissions stream with the room air entering the fume hood by creating a local zone of high turbulence. However, potential drawbacks of mixing baffles include increased flow resistance (larger blowers needed for the same exhaust flow), nuisance cleaning of baffles as soot collects, and, importantly, the potential for loss of PM2.5 particles on the baffles themselves, thus biasing results. A cookstove emission monitoring system with baffles will collect particles faster than the duct’s walls alone. This is mostly driven by the available surface area for deposition by processes of Brownian diffusion (through the boundary layer) and turbophoresis (i.e. impaction). The greater the surface area available for diffusive and advection-driven deposition to occur, the greater the particle loss will be at the sampling port. As a layer of larger particle “fuzz” builds on the mixing baffles, even greater PM2.5 loss could occur. The micro structure of the deposited aerosol will lead to increased rates of particle loss by interception and a tendency for smaller particles to deposit due to impaction on small features of the micro structure. If the flow stream could be well-mixed without the need for baffles, these drawbacks could be avoided and the cookstove emissions sampling system would be more robust.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analytical Results from final Salt Batch 9 Routine DSSHT and SEHT Monthly Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and in some cases anions (Ion Chromatography Anions - IC-A). These three samples are from Salt Batch 9 material in the Modular Caustic-Side Solvent Extraction Unit (MCU) system, and prior to actual Salt Batch 10 processing. These samples are known to contain contactor cleaning material and should not be considered typical for samples under operating conditions. While the DSSHT sample is typical of this type of sample, the SEHT samples indicate a gross inclusion of nitric acid, likely from contactor cleaning solutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of 2H-Evaporator Acid Cleaning Samples

The 2H-Evaporator acid cleaning solution samples were analyzed by SRNL to determine a composition for the scale present in the evaporator before recent acid cleaning. Composite samples were formed from the solution samples from the two acid cleaning cycles. The solution composition was converted to a weight percent scale solids basis under an assumed chemical composition. The scale composition produced from the acid cleaning solution samples indicates a concentration of 6.85 wt% uranium. An upper bound, onesided 95% confidence interval on the weight percent uranium value may be given as 6.9 wt% + 1.645 × 0.596 wt% = 7.9 wt%. The comparison of the composition from the current acid cleaning solutions with the composition of recent scale samples along with the thermodynamic modeling results provides reasonable assurance that the sample results provide a good representation of the overall scale composition in the evaporator prior to acid cleaning. The small amount of scale solids dissolved in the 1.5 M nitric acid during the evaporator cleaning process likely produced only a small amount of precipitation based on modeling results and the visual appearance of the samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Tank 30H (HTF-30-18-54, -55), Tank 32H (HTF-32-18-56, -57), and Tank 37H (HTF-37-18-58, -59) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solution s with sodium concentrations ranging from 7.89 M to 15.0 M. The samples from Tank 30H show small differences in the concentrations of the major cations and anions between the surface sample and VDS. The two Tank 32H samples show significant differences in the concentrations of the major anions and cations with the VDS being nearly twice as concentrated as the surface sample. The surface sample and VDS from Tank 37H contain very similar compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Results from the Salt Batch 10 Routine DSSHT and SEHT Monthly Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 10 have been analyzed for 238Pu, 90Sr, 137Cs, elemental constituents (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and in some cases anions (Ion Chromatography Anions - IC-A). The included tables contain the data. These samples are from Salt Batch 10 material recently introduced into the Modular Caustic-Side Solvent Extraction Unit (MCU) system. The DSSHT results are typical for this type of sample, although the dilution due to processing is lower than expected. The August sample is known to have incorporated large amounts of rain water and cannot be compared to other DSSHT samples. The SEHT sample results are typical except for the May sample which is known to have rain water and Contactor Drain Tank (CDT) material in it.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preparation of Four Large-format Hot Isostatically Pressed I-AgZ Waste Form Samples for Performance Testing

Hot isostatic pressing (HIP) is being considered as a process to directly convert 129 I-bearing materials to a durable radiological waste form. Zeolites, specifically silver-exchanged mordenite (AgZ), have been studied extensively as potential radioactive iodine sorbents and will contain 129 I as chemisorbed AgI, a relatively insoluble compound with a high melting point. Oak Ridge National Laboratory has conducted several recent studies on the HIP of both I–AgZ and other iodine-bearing zeolites, resulting in an inventory of samples prepared with a suite of zeolites with varied iodine incorporation methods, pressing conditions, and sizes. These samples have been made available to researchers at other national laboratories in support of test method development to assess the stability of heterogenous iodine-bearing waste forms. The work described here generated four large-format HIPed I–AgZ samples. These samples are 1.5 in. diameter and 2 in. length and contain 49 g of I–AgZ. Two samples were prepared at an iodine loading of 64 mg I/g I– AgZ, and two samples were prepared at an iodine loading of 135 mg I/g I–AgZ. These two sets of duplicate samples will be made available upon request in support of iodine waste form durability method development efforts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results of SRS Tank 26 Samples FTF-26-19-12 and -13

Savannah River Remediation (SRR) has requested that the Savannah River National Laboratory (SRNL) characterize several samples from the Savannah River Site (SRS) Tank Farm in preparation for Sludge Batch (SB) 10. This report documents the characterization of Tank 26 material received by SRNL in May of 2019. SRR pulled 2 x 200 mL samples (FTF-26-19-12 and FTF-26-19-13) with Tank 26 slurry pumps at 60 inches. Two samples were taken to ensure SRNL has adequate material for the requested analyses. Because both samples were taken at the same time and at the same tank level, SRNL combined the two Tank Farm samples into one sample prior to analyses. Results presented in this report include: weight percent solids, density, elemental composition of supernate and slurry, Cs-137 in supernate and slurry, and slurry total alpha and beta. The sample contained higher than expected total sulfur with a significant insoluble fraction, prompting SRR-E to request a washing study to predict how sulfur will be removed during Tank Farm washing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-20-7, -8) and tank 43H (HTF-43-20-9, -10) samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample decreased significantly from the previous surface sample. The Tank 38H sub-surface sample shows only small changes in concentration for most major species in the solution from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank. The Tank 38H sub-surface sample contained a small amount of sludge solids (<1 wt%).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Activation Study of Isotopically Enriched Samples During Neutron Time-of-Flight Measurements

Over the course of a time-of-flight neutron cross section measurement, the sample isotope(s) of interest are irradiated by neutrons and photons. Ideally, the enriched sample will not have any additional radioactivity after the measurement as compared to the baseline detectable radioactivity (0.6 Bq/g) established prior to acquisition of the sample. This document presents the process for estimating the activation of a stable enriched isotope exposed to a mixed photon and neutron source using tools from the SCALE code system developed at Oak Ridge National Laboratory. The report also presents the activation analysis for the isotopes of current interest: 90;91;92;94 Zr. This information is provided for two sets of Zr samples: one set of ZrO 2 samples, and one set of metal Zr samples. It was determined that, following measurements at the GELINA linear accelerator facility, all of the enriched Zr samples would contain less than 0.6 Bq/g of radioactivity within 183 days after irradiation.

07 ISOTOPE AND RADIATION SOURCES↗

Results of the Analyses of SMECT Mercury Sample Collected During Mercury Pump (MB1) Functional Check

A pump added to remove mercury from the sump of the Slurry Mix Evaporator Condensate Tank (SMECT) in DWPF was successfully tested in 2020, resulting in a sample of contaminated mercury obtained from the Mercury Purification Process (MPP) cell. The mercury in the sump of the SMECT was present as a result of steam stripping of sludge slurry in the Sludge Receipt and Adjustment Tank (SRAT) at DWPF. A schematic of the MPP system provided by DWPF personnel is shown in Appendix A. DWPF personnel supplied the following detailed description of the Hg sampling: “The sample provided is the result of DWPF extraction of mercury by means of the Mercury Pump-Water Cart. The Mercury Pump extracted the sample from the SMECT mercury sump. The pump uses pressurized water to transfer a small amount of mercury to a leachate bucket located at the Lab Mercury cell. The mercury and water were allowed to be self separated, and mercury was gravity decanted from the leachate bucket.” DWPF personnel indicate that the leachate bucket is equipped with both a top stopcock/drain and a lower/bottom stopcock/drain from which the mercury was decanted or drained out, while the separated water layer remained above the mercury during draining. The DWPF customer requested SRNL to analyze the sample for the following: gross alpha/nonvolatile beta analysis and perform a Toxicity Characteristic Leaching Procedure (TCLP) per the Environmental Protection Agency's Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, SW-846. While the TCLP was preferred, a Total Metals analysis of the eight Resource Conservation and Recovery Act (RCRA) metals was deemed acceptable.2 The analytical data collected on this mercury sample will be used in planning for sample disposition as well to start a profile for future Hg disposition of Hg collected from steam stripping.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-21-95, -96) and Tank 43H (HTF-43-21-97, -98) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows only minor changes in concentration for soluble species in the solution (e.g., Na, Al, Cs-137) relative to the previous sample, but a small decrease in concentrations for species typically associated with sludge solids (e.g., U, Pu, Fe, Si) likely because of a decrease in sludge solids from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intelligent Sampling for Surrogate Modeling, Hyperparameter Optimization, and Data Analysis

Sampling techniques are used in many fields, including design of experiments, image processing, and graphics. The techniques in each field are designed to meet the constraints specific to that field such as uniform coverage of the range of each dimension or random samples that are at least a certain distance apart from each other. When an application imposes new constraints, for example, by requiring samples in a non-rectangular domain or the addition of new samples to an existing set, a common solution is to modify the algorithm currently in use, often with less than satisfactory results. As an alternative, we propose the concept of intelligent sampling, where we devise algorithms specifically tailored to meet our sampling needs, either by creating new algorithms or by modifying suitable algorithms from other fields. Surprisingly, both qualitative and quantitative comparisons indicate that some relatively simple algorithms can be easily modified to meet the many sampling requirements of surrogate modeling, hyperparameter optimization, and data analysis; these algorithms outperform their more sophisticated counterparts currently in use, resulting in better use of time and computer resources.

97 MATHEMATICS AND COMPUTING↗

IDP Analysis of Tank 9H Mined Well Samples

The Savannah River Site (SRS) Tank Farm Transfer Control Program Description Document (PDD) requires Inhalation Dose Potential (IDP) testing to determine whether a transfer qualifies as a “HIGH-REM” (> 2.08E+08 rem/gal) or a “LOW-REM” (≤ 2.08E+08 rem/gal) waste transfer. Due to the unexpected presence of solids in a variable depth sample taken from Tank 9H, transfers from salt tanks potentially containing insoluble solids are currently being assessed as sludge slurry transfers. The insoluble solids concentration of such samples were requested to be adjusted to 16.7 wt% for the results to be used to bound future transfers from that tank. Two samples, HTF-09-21-100 and -101, were received from Tank 9H for analysis to determine IDP. The initial percent insoluble solids concentrations of HTF-09-21-100 and -101 were measured at 4.04 wt% and 6.23 wt%, respectively. Sample HTF-09-21-101 was adjusted to a target of at least 16.7 wt% insoluble solids by removing supernate. Analysis measured the adjusted insoluble solids concentration at 19.0 wt%. A representative sample was obtained for analysis. Then, based on calculations, supernate was added back to HTF-09-21-101 to achieve a percent insoluble solids concentration of 17.1 wt%, and a representative sample was collected for analysis. Based on duplicate analyses at 17.1 wt% and 19.0 wt% insoluble solids, the samples contain less than 0.0012 Ci/L of gross alpha activity. Therefore, the Tank 9H material can be transferred as a “LOW REM” transfer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗